FREQUENCY .............................................................................................................................................................................................. 3
INPUTS AND OUTPUTS (FRONT PANEL)....................................................................................................................................................... 10
INPUTS AND OUTPUTS (REAR PANEL)......................................................................................................................................................... 11
GENERAL SPECIFICATIONS ....................................................................................................................................................................... 12
TRACKING GENERATOR R&S®FSU-B9,ATTENUATOR R&S®FSU-B12 FOR TRACKING GENERATOR ........................................................... 13
LO/IFPORTS FOR EXTERNAL MIXERS R&S®FSU-B21(FOR R&S®FSQ26 AND R&S®FSQ40 ONLY) ......................................................... 15
Inputs and outputs (front panel)......................................................................................................................................................... 15
Dynamic range .................................................................................................................................................................................. 19
General data...................................................................................................................................................................................... 22
Specifications are valid under the following conditions:
30 minutes warm-up time at ambient temperature, specified environmental conditions met, calibration cycle adhered to, and total
calibration performed. Data without tolerances: typical values only. Data designated 'nominal' applies to design parameters and is
not tested.
Frequency
Frequency range
R&S®FSQ3: DC coupled 20 Hz to 3.6 GHz
AC coupled 1 MHz to 3.6 GHz
R&S®FSQ8: DC coupled 20 Hz to 8 GHz
AC coupled 1 MHz to 8 GHz
R&S®FSQ26: DC coupled 20 Hz to 26.5 GHz
AC coupled 10 MHz to 26.5 GHz
®
R&S
FSQ40: DC coupled 20 Hz to 40 GHz
Frequency resolution
0.01 Hz
Reference frequency, internal, nominal standard OCXO
Aging per day after 30 days of continuous operation 1 × 10
Aging per year after 30 days of continuous operation 1 × 10
–9
–7
Temperature drift +5 °C to +45 °C 8 × 10–8
Total error per year 1.8 × 10–7
4 GHz ≤ f < 8 GHz <–70 dBc
8 GHz ≤ f < 16 GHz <–64 dBc
16 GHz ≤ f < 26 GHz <–58 dBc
26.5 GHz ≤ f < 40 GHz <–52 dBc
6 Signal Analyzer R&S®FSQ Version 08.00, February 2007
Level display
Screen 625 × 500 pixel (one diagram), max. 2
Logarithmic level axis 1 dB to 200 dB, in steps of 1/2/5
Linear level axis 10 % of reference level per level division,
1 measurement diagram 3 Number of traces
2 measurement diagrams 6
Trace detector Max Peak, Min Peak, Auto Peak (Normal),
default value 625 Number of measurement points
range 155 to 30001 in steps of about a
Trace functions clear/write, Max Hold, Min Hold, average
local measurement, display update rate,
625 points, zero span
remote measurement, display off:
zero span/sweep time 1 ms
span = 10 MHz, sweep time 2.5 ms 50/s
Setting range of reference level logarithmic level display –130 dBm to (+5 dBm + RF attenuation),
linear level display 7.0 nV to 7.07 V in steps of 1 %
Units of level axis logarithmic level display dBm, dBµV, dBmV, dBµA, dBpW
linear level display µV, mV, µA, mA, pW, nW
Uncertainty of reference level setting RF attenuation 10 dB, referenced
Display non linearity
Logarithmic level display
Linear level display 5 % of reference level
Bandwidth switching error
reference level –30 dBm,
RF attenuation 10 dB
DC coupling, RF attenuation ≥ 10 dB, +20 °C to +30 °C
10 MHz ≤ f < 3.6 GHz <0.3 dB (σ = 0.1 dB)
3.6 GHz ≤ f < 8 GHz, span < 1 GHz <1.5 dB (σ = 0.5 dB)
8 GHz ≤ f < 22 GHz, span < 1 GHz <2 dB (σ = 0.7 dB)
22 GHz ≤ f < 26.5 GHz, span < 1 GHz <2.5 dB (σ = 0.8 dB)
26.5 GHz ≤ f < 40 GHz, span < 1 GHz <2.5 dB (σ = 0.8 dB)
f ≥ 3.6 GHz, span ≥ 1 GHz add 0.5 dB to above values
+5 °C to +45 °C
10 MHz ≤ f < 3.6 GHz <0.6 dB (σ = 0.2 dB)
3.6 GHz ≤ f < 26.5 GHz add 0.5 dB to above values
f ≥ 26.5 GHz add 1.0 dB to above values
0 dB to 70 dB, referenced to 10 dB
attenuation
to –10 dBm reference level setting
+20 °C to +30 °C, mixer level ≤–10 dBm
RBW ≤ 100 kHz or channel filters, S/N > 20 dB
0 dB to –70 dB <0.1 dB (σ = 0.03 dB)
–70 dB to –90 dB <0.3 dB (σ = 0.1 dB)
200 kHz ≤ RBW ≤10 MHz, S/N >16 dB
0 dB to –50 dB <0.2 dB (σ = 0.07 dB)
–50 dB to –70 dB <0.5 dB (σ = 0.17 dB)
RBW >10 MHz, S/N >16 dB
0 dB to –50 dB <0.5 dB (σ = 0.17 dB)
referenced to RBW = 10 kHz
1 Hz to 100 kHz <0.1 dB (σ = 0.03 dB)
200 kHz to 3 MHz <0.2 dB (σ = 0.07 dB)
5 MHz to 50 MHz <0.5 dB (σ = 0.15 dB)
FFT filter 1 Hz to 3 kHz <0.2 dB (σ = 0.07 dB)
diagrams with independent settings
10 divisions or logarithmic scaling
Sample, RMS, Average, Quasi Peak
factor of 2
80/s Trace update rate
70/s
max. 30 dBm, in steps of 0.1 dB
<0.2 dB (σ = 0.07 dB)
<0.2 dB (σ = 0.07 dB)
<0.15 dB (σ = 0.05 dB)
Version 08.00, February 2007 Signal Analyzer R&S®FSQ 7
Total measurement uncertainty
0 dB to –70 dB, S/N >20 dB, span/RBW < 100, 95 % confidence level,
+20 °C to +30 °C, mixer level ≤–10 dBm
f < 3.6 GHz, RBW ≤ 100 kHz 0.3 dB
f < 3.6 GHz, RBW > 100 kHz 0.5 dB
3.6 GHz ≤ f < 8 GHz 2.0 dB
8 GHz ≤ f < 18 GHz 2.5 dB
18 GHz ≤ f < 26.5 GHz 3.0 dB
26.5 GHz ≤ f < 40 GHz 3.0 dB
I/Q data
General
Interface GPIB or LAN interface
Sampling rate programmable: 10 kHz to 81.6 MHz
ADC resolution 14 bit
I/Q memory
RF path
Max. information bandwidth 28 MHz
Spurious full-scale input signal typ.<–70 dBc
Third order distortion two tones -6 dBfs each typ.<–80 dBc
LO feedthrough f
Aliased DC offset f
Frequency response
Equalized bandwidth
Amlitude flatness
Deviation from linear phase
standard 16 Msample each for I and Q data
option R&S®FSQ-B100 235 Msample
option R&S
R&S
= 81.6 MHz – f
I/Q
mixer level = –10 dBm
= 20.4 MHz; within ±10 K temperature
I/Q
change after I/Q or total calibration
RBW setting equalized bandwidth
3 MHz 2 MHz
5 MHz 3 MHz
10 MHz 7 MHz
20 MHz 17 MHz
50 MHz 28 MHz
within equalized bandwidth
f ≤ 3.6 GHz typ.0.3 dB
f > 3.6 GHz, YIG filter off typ.0.5 dB
within equalized bandwidth
f ≤ 3.6 GHz typ. 1°
f > 3.6 GHz, YIG filter off typ. 2°
®
FSQ-B100 and
®
FSQ-B102
center
in 0.1 Hz steps
705 Msample
typ.<–65 dBfs
typ.<–65 dBfs
Audio demodulation
AF demodulation types AM and FM
Audio output loudspeaker and phone jack
Marker stop time in spectrum mode 100 ms to 60 s
8 Signal Analyzer R&S®FSQ Version 08.00, February 2007
Loading...
+ 18 hidden pages