Rohde and Schwarz ENV216 Specifications Sheet

Two-Line V-Network R&S ENV216
for RFI voltage measurements on single-phase EUTs
Frequency range 9 kHz to 30 MHz
Power-handling capacity 16 A,
constant current
150 kHz highpass filter, switch-
selectable
Built-in 10 dB attenuator and pulse
limiter
V-network to CISPR, EN, VDE, ANSI
Calibrated to CISPR 16-1:1999 and
ANSI C63.4
Air-core design
Artificial hand
Remote control with TTL
levels via optocoupler
Characteristics, use
Certified Quality System
ISO 9001
Certified Environmental System
ISO 14001
DQS REG. NO 1954 QM
DQS REG. NO 1954 UM
The Two-Line V-Network R&S ENV 216 (50 µH + 5 )//50 satisfies the requirements of VDE 0876 and CISPR Publ. 16-1 for V-networks (incl. the requirements of the planned extension for CISPR/A/413/CD regarding the isola­tion between EUT and power port and the impedance with respect to magnitude and phase) in the frequency range 9 kHz to 30 MHz. It is based on air-core induc­tances and contains an artificial hand.
A 16 A female connector with earthing contact is provided for connecting the EUT. Various models with country-specific connector systems are available.
2 Two-Line V-Network R&S ENV 216
To prevent the test receiver from being overdriven by low-frequency spectra of high level, a 150 kHz highpass filter can be cut in. To ensure standard impedance irrespective of the receiver input attenua­tion, the R&S ENV 216 is equipped with a 10 dB attenuator. A built-in pulse limiter protects the receiver input.
TTL control inputs that can be driven by controllers and R&S test receivers are pro­vided for remote control in automatic test systems (phase selection and activation of highpass filter). Optocouplers prevent pick-up of external RFI. In the case of AC supply operation, the operating voltage for the built-in logic circuit is obtained in a range from 90 V to 250 V and 47 Hz to 63 Hz. This covers all standard applica­tions. If the EUT is operated with low AC voltages or DC voltages up to 50 V, the logic circuit is powered via an external
plug-in power supply. Owing to its com­pact design and low weight, the R&S ENV216 is ideal for frequently varying applications and especially for on-site RFI voltage measurements on single-phase EUTs. Note that high leakage currents are produced because of the standard design of these V-networks. The networks should therefore be connected to a low-imped­ance protective earth system. In ques­tionable cases, an isolating transformer should be used.
Specifications
Frequency range 9 kHz to 30 MHz
Impedance characteristic of V-network to CISPR 16-1:1999 (50 µH + 5 )//50
Error limits (to CISPR 16-1)
Impedance magnitude Phase
Max. permissible constant current for plug and socket (dependent on country)
Vers ion 02 Vers ion 03 Vers ion 04 Vers ion 05 Vers ion 06
Max. permissible AC supply voltage against reference ground V
Max. permissible DC voltage against reference ground VDC = 50 V
Max. permissible RFI (from EUT) 1 W
Highpass filter (integrated, switch-selectable) 150 kHz
Attenuator (built-in) 10 dB
Response threshold of built-in pulse limiter (output level) 140 dB(µV)
AC supply frequency 0 to 63 Hz
Connectors
AC supply voltage input plug with earthing contact and 1.8 m cable
AC supply voltage input for EUT socket with earthing contact (country-specific models)
RF output N connector, female, 50
Remote control input 25-contact Sub-D connector, female
Input for artificial hand 4 mm connector, female, with knurled clamp
Reference ground connection ground bar with 3 M4 threads
Protective earth connection threaded bolt with wing nut
Connector for external power supply DC hollow connector, 5.5/2.1 mm dia., 10 V to 18 V DC, 250 mA
General data
Operating temperature range 0°C to +45°C
Storage temperature range −25°C to +70°C
Dimensions (W x H x D) 219 mm x 147 mm x 350 mm
Weig ht 5.5 kg
Order designation
Two-Lin e V-Net wo rk R&S ENV 216 3560.6550.yy
Model for Germany (earthing-type connector) yy = 02
United Kingdom yy = 03
France yy = 04
China, Australia yy = 05
USA yy = 06
Accessories supplied
Manual, calibration record
Plug-in power supply (country-specific)
Recommended extras
Remote control cable, 25-contact
Control by receiver of R&S ESxS, R&S ESIBx, R&S ESPIx series
(connector/connector, 1:1 wiring; two cables required for shielded rooms) Control Cable, 3 m Control Cable, 10 m
±20% ±11.5 °
16 A 13 A 16 A 15 A 15 A
= 255 V
rms
(country-specific models)
(met by supplied plug-in power supply)
R&S EZ-21 1107.2087.03 R&S EZ-21 1107.2087.10
Two-Line V-Network R&S ENV 216 3
Country-specific connector models
Germany as well as Austria, Finland, the Nether­lands, Norway, Russia, Sweden; occasionally: Portugal, Spain
UK as well as Ireland, Hong Kong, Malaysia, Singapore
France as well as Belgium and Czech Republic
China as well as Australia and New Zealand
USA as well as Canada, Japan, Korea, Taiwan, Mexico, Central America
Printed in Germany 0403 (Pe we)
ROHDE&SCHWARZ GmbH & Co. KG Mühldorfstraße 15 81671 München Germany P.O.B. 8014 69 81614 München Germany Telephone +49 89 4129-0
www.rohde-schwarz.com Customer Support: Telephone +49 180512 4242, Fax +49 89 4129-13777, E-mail: CustomerSupport@rohde-schwarz.com
PD 0757.8265.21Two-Line V-Network R&S ENV 216Trade names are trademarks of the ownersSubject to changeData without tolerances: typical values
Loading...