12V /30Amp Low Voltage Disconnect
(LVD)
Part No. 1950-241
+0.490 For Switch
Rogue Engineering Inc.
3860 S. Jason Street
Englewood Colorado 80110
Document Rev. 140302
1-800-364-0659 (Toll Free) 1-303-734-0706 (Phone)
1-303-734-0517 (Fax) www.rogue-engr.com
info@rogue-engr.com or sales@rogue-engr.com
Charging Ahead
Why Choose Rogue’s 12V/30Amp LVD?
Bene ts
• Easy to install
• Control up to 360 Watt load directly or add a separate relay to control
even larger Loads
• 7 position selector switch makes it easy to choose the shut-o
voltage or “always on” LVD override
• Disconnect voltage selections range from 9.5V to 11.5V
• Low voltage LV Alert output
• Uses a 30 Amp automotive style fuse for protection and easy
replacement
Applications
• Idle reduction for work vehicles
• O -grid solar installations
• Recreational vehicles
• And many other battery-powered installations
Battery +
Load +
GND
LV
Ale
rt
Battery -
Load -
Features
• Supports all 12V lead acid batteries
• Conformal coated and potted for humid conditions
• Disconnect voltages are every 0.5V from 9.5V to 11.5V
• Approximate 10 second delay before disconnect
• Self-consumption (Typical): LVD unit “ON” or set an LVD threshold: 8
milliamps (mA) and LVD unit set to “OFF”: 800 microamps (uA)
Testing and Reliability
Each LVD is fully tested and inspected, ensuring reliability.
Be sure to visit our website for additional products including our
1950-222, 12V 15Amp LVD, Solar Charge Controllers and much more.
Products o ered are designed and manufactured by Rogue Engineering Inc. in
Englewood, Colorado, U.S.A.
Rogue Engineering Inc.
3860 S. Jason Street
Englewood Colorado 80110
1-800-364-0659 (Toll Free) 1-303-734-0706 (Phone)
1-303-734-0517 (Fax) www.rogue-engr.com
info@rogue-engr.com or sales@rogue-engr.com
Installation Instructions
• Connect 12V Battery and 12V Load as shown in the illustration above.
• Connect black ground wire to system’s common ground.
• Turn knob to selected disconnect voltage or to “ON” for continuous
operation or “OFF”.
• Power to the load will be disconnected when battery voltage reaches
selected voltage and
will reconnect when the battery is charged
1 Volt higher than selected voltage.
• If Load does not receive power when connected to a good battery, check
the fuse.
• If used, connect the orange LV Alert wire to relay or other control
equipment. When battery is low, LV Alert outputs battery voltage at
300mA max.
Note: Under no circumstances should a fuse over 30 Amps be used with this
device.