Rogue Engineering 1950-241 User Manual

Dimensions
(LVD)
Part No. 1950-241
+0.490 For Switch
Rogue Engineering Inc. 3860 S. Jason Street Englewood Colorado 80110
Document Rev. 140302
1-800-364-0659 (Toll Free) 1-303-734-0706 (Phone) 1-303-734-0517 (Fax) www.rogue-engr.com info@rogue-engr.com or sales@rogue-engr.com
Charging Ahead
Why Choose Rogue’s 12V/30Amp LVD?
Bene ts
Easy to install
Control up to 360 Watt load directly or add a separate relay to control
even larger Loads
7 position selector switch makes it easy to choose the shut-o voltage or “always on” LVD override
Disconnect voltage selections range from 9.5V to 11.5V
Low voltage LV Alert output
Uses a 30 Amp automotive style fuse for protection and easy
replacement
Applications
Idle reduction for work vehicles
O -grid solar installations
Recreational vehicles
And many other battery-powered installations
Battery +
Load +
GND
LV
Ale
rt
Battery -
Load -
Features
Supports all 12V lead acid batteries
Conformal coated and potted for humid conditions
Disconnect voltages are every 0.5V from 9.5V to 11.5V
Approximate 10 second delay before disconnect
Self-consumption (Typical): LVD unit “ON” or set an LVD threshold: 8
milliamps (mA) and LVD unit set to “OFF”: 800 microamps (uA)
Testing and Reliability
Each LVD is fully tested and inspected, ensuring reliability.
Be sure to visit our website for additional products including our
1950-222, 12V 15Amp LVD, Solar Charge Controllers and much more.
Products o ered are designed and manufactured by Rogue Engineering Inc. in
Englewood, Colorado, U.S.A.
Rogue Engineering Inc. 3860 S. Jason Street Englewood Colorado 80110
1-800-364-0659 (Toll Free) 1-303-734-0706 (Phone) 1-303-734-0517 (Fax) www.rogue-engr.com info@rogue-engr.com or sales@rogue-engr.com
Installation Instructions
Connect 12V Battery and 12V Load as shown in the illustration above.
Connect black ground wire to system’s common ground.
Turn knob to selected disconnect voltage or to “ON” for continuous
operation or “OFF”.
Power to the load will be disconnected when battery voltage reaches selected voltage and
will reconnect when the battery is charged
1 Volt higher than selected voltage.
If Load does not receive power when connected to a good battery, check the fuse.
If used, connect the orange LV Alert wire to relay or other control equipment. When battery is low, LV Alert outputs battery voltage at 300mA max.
Note: Under no circumstances should a fuse over 30 Amps be used with this device.