Rogue Engineering 1950-222 User Manual

Dimensions
12V /15Amp Low Voltage Disconnect
(LVD)
Part No. 1950-222
+0.560 For Fuse
Rogue Engineering Inc. 3860 S. Jason Street Englewood Colorado 80110
Document Rev. 140303
1-800-364-0659 (Toll Free) 1-303-734-0706 (Phone) 1-303-734-0517 (Fax) www.rogue-engr.com info@rogue-engr.com or sales@rogue-engr.com
Charging Ahead
Why Choose Rogue’s 12V/15Amp LVD?
Bene ts
Easy to Install
Control up to 180 Watt load directly or add a separate relay to control
even larger Loads
7 position selector switch makes it easy to choose the shut-o voltage or “always on” LVD override
Disconnect voltage selections range from 9.0V to 11.5V
Uses a 15 Amp automotive style fuse for protection and easy
replacement
Applications
Idle reduction for work vehicles
O -grid solar installations
Recreational vehicles
And many other battery-powered installations
Features
Supports all 12V lead acid batteries
Conformal coated and potted for humid conditions
Disconnect voltages are every 0.5V from 9.0V to 11.5V
Self-Consumption: Battery (supply) voltage above disconnect
threshold: 2 milliamps (mA) and battery (supply) voltage below disconnect threshold: 550 microamps (uA)
Testing and Reliability
Each LVD is fully tested and inspected, ensuring reliability.
Load+ Load-
Battery+ Battery-
Installation Instructions
Connect 12V Battery and 12V Load as shown in the illustration above.
Turn knob to selected disconnect voltage or to “ON” for continous operation.
Power to the Load will be disconnected when battery voltage reaches selected voltage and
charged 1 Volt higher than selected voltage.
If Load does not receive power when connected to a good battery, check the fuse.
will reconnect when the battery is
Be sure to visit our website for additional products
including our 1950-241, 12V 30Amp LVD, Solar Battery
Charge Controllers and much more.
Rogue Engineering Inc. 3860 S. Jason Street Englewood Colorado 80110
1-800-364-0659 (Toll Free) 1-303-734-0706 (Phone) 1-303-734-0517 (Fax) www.rogue-engr.com info@rogue-engr.com or sales@rogue-engr.com
Note: Under no circumstances should a fuse rated over 15 Amps be used with this device.