Roger PR612, PR622, PR312EM-BK, PR312MF, PR312MF-BK Installation Manual

...
Page 1
Roger Access Control System
Installation guide for PR612, PR622, PR312EM,
PR312EM-BK, PR312MF and PR312MF-BK access
controllers
Firmware version: 1.18.6 or newer
Document version: Rev. G
© 2016 ROGER sp. z o.o. sp.k. All rights reserved. This document is subject to the Terms of Use in their current version published at the www.roger.pl website of the Roger sp. z o.o. sp.k. company (hereinafter referred to as ROGER).
Page 2
PR612 PR622 PR312EM PR312MF Installation guide Rev.G.doc
2017-09-18
2/16
Contents
1. Introduction .................................................................................................................. 3
2. Description and specification ........................................................................................ 3
3. Installation .................................................................................................................... 4
3.1 Terminals/wires and connection diagram ............................................................................. 4
3.2 LED indicators .................................................................................................................... 5
3.3 Power supply ..................................................................................................................... 6
3.4 Connection of door lock ...................................................................................................... 6
3.5 Communication with controller ............................................................................................ 6
3.6 Communication of controller with peripheral devices ............................................................ 7
3.7 Input and output lines ........................................................................................................ 7
3.7.1 Inputs ........................................................................................................................... 7
3.7.2 Relay outputs ................................................................................................................ 7
3.7.3 General purpose outputs ................................................................................................ 7
3.8 Wall mounting.................................................................................................................... 8
3.9 Installation guidelines ....................................................................................................... 12
4. Configuration............................................................................................................... 12
4.1 Controller address ............................................................................................................ 12
4.1.1 Addressing during firmware update (Fixed ID) .............................................................. 12
4.1.2 Addressing during Memory Reset procedure .................................................................. 13
4.1.3 Addressing by means of PR Master software ................................................................. 13
4.1.4 Addressing by means of command entered with keypad ................................................ 13
4.2 Memory Reset procedure .................................................................................................. 13
4.2.1 Simplified Memory Reset Procedure .............................................................................. 13
4.2.2 Full Memory Reset procedure (controller with keypad) ................................................... 13
4.2.3 Full Memory Reset procedure (controller without keypad) .............................................. 14
4.3 Controller programming .................................................................................................... 14
4.4 Firmware update .............................................................................................................. 14
5. Ordering information................................................................................................... 15
6. Product history ............................................................................................................ 16
Page 3
PR612 PR622 PR312EM PR312MF Installation guide Rev.G.doc
2017-09-18
3/16
1. INTRODUCTION
This manual contains minimum information that is necessary to properly install devices and to perform initial tests. Following documents which are available at www.roger.pl supplement this manual:
Functional description of PRxx2 series controllers PR Master User Manual
2. DESCRIPTION AND SPECIFICATION
PR612, PR622, PR312EM, PR312EM-BK, PR312MF and PR312MF-BK are single door access controllers used in RACS 4 access control system. All devices are functionally identical but PR612, PR312EM and PR312MF are equipped with keypad while PR622, PR312EM-BK and PR312MF-BK are not. Additionally PR312MF and PR312MF-BK controllers are equipped with built-in MIFARE® proximity card reader while the remaining controllers are equipped with built-in EM125kHz proximity card reader. This MIFARE reader enables serial number (CSN) reading for such cards as MIFARE Ultralight/Classic/Plus/Desfire. The new, factory-made controller has the address ID=00 and MASTER proximity card is included. The card can be used for initial tests after installation. Additional external reader operating in RACS CLK/DTA (PRT series terminal) format can be connected if it is required to provide read in and read out control. Controllers can be configured with PR Master software and they can be connected to PC by means of communication interface e.g. UT-2USB, UT-4DR, RUD-1 or by means of CPR32-NET network controller.
Note: PR612/PR622 controllers require PR Master 4.4.12 or newer, PR312EM/PR312EM-BK controllers require PR Master 4.5.6 or newer while PR312MF/PR312MF-BK controllers require PR Master 4.5.14 or newer.
Table 1. Specification
Supply voltage
Nominal 12VDC, min./max. range 10-15VDC
Proximity cards
EM 125 kHz (UNIQUE) according to EM4100/4102 or
13.56 MHz according to ISO/IEC 14443A and MIFARE
Reading distance
Up to 15 cm for ISO cards (depends on card type and quality)
Average current consumption
PR612/PR312EM/PR312MF: 70mA PR622/PR312EM-BK/PR312MF/BK: 50mA
Tamper
Isolated contact, NC type, 24V/50 mA rated
Inputs
Three (IN1..IN3) NO/NC inputs, electrically biased to +12V via 15kΩ resistor, triggering level approx. 3.5V
Relay output
One (REL1) relay output with single NO/NC contact, 30V/1.5A
Transistor outputs
Two (IO1,IO2) open collector outputs, 15VDC/1A
Distances
Between controller and communication interface (RS485): max. 1200m Between reader and controller: max. 150 m Between controller and I/O expanders: max. 150 m
Environmental class (according to EN 50131-1)
Class IV, outdoor general conditions, temperature: -25°C to +60°C, relative humidity: 10 to 95% (no condensation) IP code
IP65
Dimensions HxWxD
PR612: 115 x 80 x 35 mm
Page 4
PR612 PR622 PR312EM PR312MF Installation guide Rev.G.doc
2017-09-18
4/16
PR622: 85 x 85 x 27 mm PR312EM/PR312MF: 152,5 x 46 x 23(35)mm PR312EM-BK/PR312MF-BK: 152,5 x 46 x 23(35)mm
Weight
PR612/PR622: approx. 120g PR312EM/PR312EM-BK: approx. 150g PR312MF/PR312MF-BK: approx. 150g
Certificates
CE
3. INSTALLATION
3.1 Terminals/wires and connection diagram
Table 2. Terminals and wires
Screw terminal (PR612/PR622)
Wire colour (PR312EM/
PR312MF)
Description
+12V
Red
12VDC power supply
GND
Black
Ground
IN1
Pink
IN1 input line
IN2
Blue
IN2 input line
IN3
White-yellow
IN3 input line
RS485 A
Brown
RS485 communication bus
RS485 B
Green-white
RS485 communication bus
CLK
White
RACS CLK/DTA comm. bus
DTA
Green
RACS CLK/DTA comm. bus
TMP A
Grey
Tamper switch
TMP B
Yellow
Tamper switch
IO1
Yellow-brown
IO1 output line
IO2
Green-brown
IO2 output line
REL1-NC
Grey-pink
REL1 relay output (NC)
REL1-COM
Red-blue
REL1 relay common terminal
REL1-NO
Violet
REL1 relay output (NO)
Page 5
PR612 PR622 PR312EM PR312MF Installation guide Rev.G.doc
2017-09-18
5/16
Fig. 1 Connection diagram
3.2 LED indicators
Controllers are equipped with 3 LED indicators. Their functions and colours are specified in table 3 below. Functioning of LEDs can be verified by means of included MASTER card after connection of power supply to the controller.
Page 6
PR612 PR622 PR312EM PR312MF Installation guide Rev.G.doc
2017-09-18
6/16
Table 3. LED indicators
Symbol
Name
Colour
Description
STATUS
Red/Green
Armed/Disarmed Mode respectively
OPEN
Green
Door unlocking
SYSTEM
Orange
Various system functions and programming
3.3 Power supply
Controllers require 12VDC nominal power supply. The power should be connected to the +12V line and -12V line. Additionally, the -12V line can be used as reference potential for the RS485 bus, IN1­IN3 input lines and RACS LCK/DTA bus. The power supply can be provided by means of power supply unit (e.g. PS-15DR, PS20) which can be equipped with backup battery in order to ensure operation of access control in case of power failure.
Note: All devices connected to RS485 bus (including controllers) should have the same supply minus (GND). In order to ensure this, all the GND terminals from various power supply units within the system should be connected with each other using separate wire. Alternatively, the common supply minus of the entire system can be earthed however only in one point.
3.4 Connection of door lock
In majority of cases, door locking devices are inductive type. It means that overvoltage (voltage surge) can occur when current flow is interrupted and it can interfere with the controller electronic components. In extreme cases it may result in improper operation of the controller or even freeze. Moreover, overvoltage condition causes quicker wear of relay contacts. In order to limit this adverse effect, it is necessary to use a general type semiconductor diode e.g. 1N4007 (one piece of such diode is included with the controller). The diode should be connected as close as possible to the inductive element (electric strike or magnetic lock).
Fig. 2 Connection of door lock
3.5 Communication with controller
RS485 bus and UT communication interface (e.g. UT-2USB) are used for communication with controller. Single RS485 bus creates network (subsystem) and up to 32 controllers with unique addresses in range of 00.99 can be connected to the bus. For the communication with distant subsystems it is required to use UT-4DR or UT-4 v2.0 communication interface or CPR32-NET network controller as all of them enable communication through computer network (LAN or WAN).
Page 7
PR612 PR622 PR312EM PR312MF Installation guide Rev.G.doc
2017-09-18
7/16
The RS485 bus consists of two signal lines A and B. In the RACS 4 system any topology can be used (star, tree or any combination of them, except for loop) in order to connect controllers in network (subsystem). The matching resistors (terminators) connected at the ends of transmitting lines are not required. In most cases communication works with any cable type (standard telephone cable, shielded or unshielded twisted pair etc.) but the recommended cable is unshielded twisted pair (U/UTP cat.5). Shielded cables should be limited to installations subject to strong electromagnetic interferences. The RS485 communication standard used in the RACS 4 system guarantees proper communication in a distance of up to 1200 meters as well as high resistance to interferences.
3.6 Communication of controller with peripheral devices
The communication of controller and peripheral devices can be established by means of RACS CLK/DTA. RACS CLK/DTA is the addressable bidirectional communication standard developed by Roger company. Addresses of all devices connected to CLK and DTA lines must be properly configured in range of 0..15. Factory default address of peripheral devices can be changed according to procedures specified in their manuals but in majority of cases it is not necessary to modify the addresses at all. Standard unshielded signal cables (e.g. U/UTP cat. 5) with maximal length of 150m can be used for RACS CLK/DTA communication. Practically, devices communicating on RACS CLK/DTA bus can be connected to the controller in distance up to 500m, but such conditions are not guaranteed by the manufacturer. The controller is equipped with built-in reader and can operate with external PRT series reader, XM­2 I/O expander, up to four XM-8 expanders dedicated to access control in elevators and HRT82FK function key panel. The address of PRT reader must be ID=0 (i.e. default address), the address of XM-2 expander must be ID=5, addresses of XM-8 expanders must be in range of ID=8..11 and the address of HRT82FK must be ID=12. All mentioned devices must be connected to CLK and DTA lines of the controller.
3.7 Input and output lines
The functions are assigned to inputs and outputs by means of PR Master software. Default function for REL1 relay output is door unlocking.
3.7.1 Inputs
All inputs (IN1..IN3) of controllers have identical electric structure and can be configured as NO or NC lines using PR Master software. The NO input is triggered by shorting it to supply minus (GND) while the NC input must be normally shorted to supply minus (GND) and it becomes triggered when connection with GND is interrupted. Every input is internally connected (pulled up) to the power supply plus (+12V) through a 15kΩ resistor.
3.7.2 Relay outputs
Controllers offer one relay output (REL1) with single switching contact. Maximum load for REL1 equals to 30V/1.5A. In the normal state (relay is off) the NC-COM contacts are shorted. In the triggering state (relay is on) the NO-COM contacts are shorted. In case of power outage both relays remain in the off state.
3.7.3 General purpose outputs
Controllers offer two transistor outputs (IO1, IO2). Both outputs are open collector type i.e. in normal (off) state are pulled to supply plus via 15kΩ resistor and when in trigger (on) state they short to supply minus. Maximum load for each output equals to 15VDC/1A. In case of overcurrent outputs are automatically switched off and controller automatically restarts.
Page 8
PR612 PR622 PR312EM PR312MF Installation guide Rev.G.doc
2017-09-18
8/16
3.8 Wall mounting
Fig. 3 Installation of PR612 controller
Page 9
PR612 PR622 PR312EM PR312MF Installation guide Rev.G.doc
2017-09-18
9/16
Fig. 4 Installation of PR622 controller
Page 10
PR612 PR622 PR312EM PR312MF Installation guide Rev.G.doc
2017-09-18
10/16
Fig. 5 Installation of PR312EM/PR312MF controllers (standard enclosure base)
Page 11
PR612 PR622 PR312EM PR312MF Installation guide Rev.G.doc
2017-09-18
11/16
Fig. 6 Installation of PR312EM/PR312MF controllers (additional enclosure base)
Page 12
PR612 PR622 PR312EM PR312MF Installation guide Rev.G.doc
2017-09-18
12/16
3.9 Installation guidelines
Install devices in such way as to ensure easy access to screw terminals and jumpers (RST, FDM)
located inside the controller – see fig. 7.
Prior to controller installation it is recommended to configure its address (ID number) – see 4.1
Controller address. Factory default address is ID=00.
The controller is delivered with MASTER proximity card, however any proximity card in EM
125kHz (UNIQUE) or MIFARE format (depending on controller type) can be programmed as MASTER card.
The controller should be installed at wall in vicinity of controlled door. All electric connections must be made with power supply switched off. All devices connected to the same communication bus (RS485 and RACS CLK/DTA) should be
connected to the same negative potential (GND). Therefore all GND terminals from various power supply units used in the system should be connected with each other.
General purpose diode e.g. 1N4007 should be always connected in parallel and as close as
possible to the door locking device (magnetic lock, electric strike, relay, contactor).
It is required to install readers in minimal distance of 0.5m from each other. If two readers have
to be installed on opposite sides of the same wall, it is recommended not to place them directly opposite (in the same axis). If this condition cannot be fulfilled then place metal plate between reader and wall as well as non-metal spacer with 10mm minimal thickness between reader and metal plate.
Because of relatively low magnetic field readers should not interfere with other devices,
however its operation can be disrupted by devices generating strong electromagnetic field.
If the range of card reading is significantly lower than specified in technical documentation then
consider relocation of the reader.
Readers can be installed on metal surfaces but in such case reduction of reading distance
should be expected. The reading distance reduction effect can be minimized by installing readers on non-metal spacer with minimal thickness of 10 mm (e.g. PVC).
4. CONFIGURATION
4.1 Controller address
If controller works autonomously (standalone mode), then address setting can be skipped and default address ID =00 can be used but if the controller is to be connected with other controllers by means of RS485 bus and operate in network system, then it is necessary to assign unique addres s to such controller (ID number from range 00..99). Two or more devices with the same address result in communication conflict and make a proper communication with these devices impossible. Following addressing methods are available:
During update of controller firmware by means of RogerISP software (so called Fixed ID) Manually during Memory Reset procedure By means of PR Master software Manually with command entered from keypad
The first method enables configuration of hardware address while the remaining ones enable configuration of software addresses. The main difference between these two addressing methods is such that software address contrary to hardware address can be modified using any of mentioned methods. Therefore Fixed ID has the highest priority and the other methods have lower priority.
Note: A new controller can be connected to the existing system without the necessity to change its address but only if no other controller operates with default address ID=00. Once the controller is connected to the RS485 communication bus, it should be detected by means of PR Master software and new address should be configured.
4.1.1 Addressing during firmware update (Fixed ID)
FixedID can be set during update of the controller firmware by means of RogerISP software. Prior to firmware upload, RogerISP software offers the possibility to set Fixed ID address in range of
00..99 or disable it (FixedID=None). Once the FixedID is selected and uploaded to the controller
Page 13
PR612 PR622 PR312EM PR312MF Installation guide Rev.G.doc
2017-09-18
13/16
software addressing is ignored. In order to disable or modify FixedID it is necessary to start firmware upload procedure.
Note: When FixedID is configured then controller address cannot be modified based on software addressing method. FixedID address is maintained even in case of controller configuration error. Therefore controller can be always detected on the communication bus with the same address by means of PR Master software.
4.1.2 Addressing during Memory Reset procedure
Software address can be configured during Memory Reset procedure – see 4.2 Memory Reset procedure.
Note: Software address is effective only if FixedID is None.
4.1.3 Addressing by means of PR Master software
Software address can be configured by means of PR Master software. In such case connect the controller to PC via communication interface (e.g. UT-2USB, UT-4DR) or via CPR32-NET network controller, detect the controller and configure the address.
Note: Software address is effective only if FixedID is None.
4.1.4 Addressing by means of command entered with keypad
All commands for manual programming of controller by means of keypad are specified in the document Functional description of PRxx2 series controllers, which is available at www.roger.pl. PR622 and PR312EM-BK controllers which are not equipped with keypad can also be programmed manually. In such case it is necessary to connect PRT series reader with keypad (e.g. PRT12LT) to such controller. Following Keypad Command can be used for addressing:
[*][0][0][#][Login][new ID address][#]
Note: Keypad Command requires previous configuration by means of PR Master software in regard of its schedule and authorization By default the command is disabled.
4.2 Memory Reset procedure
Memory Reset procedure erases current settings and restores default factory settings. Additionally Full Memory Reset enables to program new MASTER card/PIN as well as new address of the controller. After Memory Reset procedure the controller automatically enters normal working mode.
Note: If current address of the controller is hardware type (see 4.1 Controller address) i.e. FixedID then address selected during Memory Reset procedure is ignored.
4.2.1 Simplified Memory Reset Procedure
Simplified Memory Reset restores default settings with controller address ID=00.
Remove connections to CLK and IN1 terminals/wires Connect CLK with IN1 Restart the controller (place and remove jumper on RST contacts – see fig. 7 or switch power
supply off/on) – LED OPEN (green) shall start to pulsate
Disconnect CLK and IN1 After a few seconds the controller shall restart automatically and switch to normal mode
4.2.2 Full Memory Reset procedure (controller with keypad)
Full Memory Reset restores default settings and enables programming of new MASTER card, MASTER PIN and controller ID address.
Page 14
PR612 PR622 PR312EM PR312MF Installation guide Rev.G.doc
2017-09-18
14/16
Remove connections to CLK and DTA terminals/wires Connect CLK with DTA Restart the controller (place and remove jumper on RST contacts – see fig. 7 or switch power
supply off/on) – LED OPEN (green) shall start to pulsate
Disconnect CLK and DTA Enter new MASTER PIN (3 to 6 digits) followed with the [#] key or skip this step and press only
the [#] key
Read any card at the reader, this will be a new MASTER card or skip this step and press only
the [#] key
Enter two digits (in range of 00 to 99) by means of keypad, this will be new ID address or skip
this step and press only the [#] key so the default ID=00 could be assigned
After a few seconds the controller shall restart automatically and switch to normal mode
4.2.3 Full Memory Reset procedure (controller without keypad)
Full Memory Reset restores default settings and enables programming of new MASTER card and controller ID address using card readings.
Remove connections to CLK and IN3 terminals/wires Connect CLK with IN3 Restart the controller (place and remove jumper on RST contacts – see fig. 7 or switch power
supply off/on) – the controller shall switch all LED indicators on and shall generate continuous acoustic signal
Disconnect CLK and IN3 – the controller shall switch all LED indicators off and then LED OPEN
and LED STATUS indicators shall pulsate till the end of reset procedure
Read any card at the controller, this will be the new MASTER card. Then the controller shall
generate two short acoustic signals
Read MASTER card X times where X corresponds to the first digit of the required controller ID
address. Each card reading shall temporarily switch LED SYSTEM on. Then wait until the controller generates two short acoustic signals
Read MASTER card Y times where Y corresponds to the second digit of the required controller
ID address. Each card reading shall temporarily switch LED SYSTEM on. Then wait until the controller generates three short acoustic signals
After a few seconds the controller shall restart automatically and switch to normal mode
After Memory Reset controller resumes its work with default factory settings and configured address. You can then test its operation using MASTER card or PIN (if available). Using the MASTER card/PIN once activates the REL1 output for 4 seconds (LED OPEN ). Using the MASTER card/PIN twice switches the IO1 output to the opposite state and switches Arm/Disarm Mode (LED STATUS
changes its colour).
4.3 Controller programming
Controllers can be configured by means of:
PR Master software installed on computer connected to the controller via communication
interface (e.g. UT-2USB, UT-4DR) or via CPR32-NET network controller
Commands entered with keypad (limited settings only)
More information on controllers programming can be found in the document Functional description of PRxx2 series controllers as well as in PR Master User Manual, which are available at
www.roger.pl.
4.4 Firmware update
The latest versions of firmware and Roger ISP software are available at www.roger.pl. In order to update firmware it is necessary to connect the device by means of RS485 bus to communication interface (UT-2USB or RUD-1) and then connect the interface to PC with installed Roger ISP software. It is not necessary to disconnect the controller from access control system, it is only required to place FDM jumper in order to put the device in firmware download mode. Therefore firmware update can be performed by means of RS485 bus of access control system.
Page 15
PR612 PR622 PR312EM PR312MF Installation guide Rev.G.doc
2017-09-18
15/16
Firmware update procedure
Place jumper on FDM pins (see fig. 7)
Fig. 7 Location of FDM and RST contacts inside the enclosure of controller
Reset device (place and remove jumper on RST pins or switch power off/on) Start RogerISP software and select communication port (in case of RUD-1 select USB-RS485
Converter).
Press the button Erase Once more reset device (place and remove jumper on RST pins or switch power off/on) In Firmware window select firmware *.hex file (can be downloaded from www.roger.pl) and
then select the button Program
After firmware upload remove jumper from FDM pins and reset device (place and remove
jumper on RST contacts or switch power off/on)
Note: If the controller is not responding and LED SYSTEM (orange) is on after firmware update procedure then it is necessary to perform reset – see 4.2 Memory Reset procedure or update the firmware once more.
Note: In case of network system, it is required to restart controller within PR Master software by right clicking particular controller and selecting the option Restart controller and verify version.
5. ORDERING INFORMATION
Table 4. Ordering information
PR612
Access controller with built-in EM 125 kHz (UNIQUE) card reader and keypad.
PR622
Access controller with built-in EM 125 kHz (UNIQUE) card reader.
PR312EM
Access controller with built-in EM 125 kHz (UNIQUE) card reader and keypad.
PR312EM-BK
Access controller with built-in EM 125 kHz (UNIQUE) card reader
PR312MF
Access controller with built-in MIFARE card reader and keypad.
PR312MF-BK
Access controller with built-in MIFARE card reader
PS-15DR
13.8VDC/1.5A power supply unit adapted to installation on DIN 35mm rail
PS-20
13.8VDC/2A power supply unit in metal enclosure and space for 12V/7Ah backup battery
Page 16
PR612 PR622 PR312EM PR312MF Installation guide Rev.G.doc
2017-09-18
16/16
CPR32-NET­BRD
Electronic module of network controller UT-4DR
Ethernet-RS485 communication interface:
UT-2USB
USB-RS485 communication interface:
RUD-1
Portable USB-RS485 communication interface with 12VDC/0.12A output
XM-2DR
I/O expander
XM-8DR
I/O expander (elevator access control)
6. PRODUCT HISTORY
Table 5. Product history
Product version
Released
Description
PR612/PR622 v.1.0
11/2012
The first commercial version of the product
PR312EM v.1.0
03/2014
The first commercial version of the product
PR312MF v.1.0
01/2015
The first commercial version of the product
This symbol placed on a product or packaging indicates that the product should not be disposed of with other wastes as this may have a negative impact on the environment and health. The user is obliged to deliver equipment to the designated collection points of electric and electronic waste. For detailed information on recycling, contact your local authorities, waste disposal company or point of purchase. Separate collection and recycling of this type of waste contributes to the protection of the natural resources and is safe to health and the environment. Weight of the equipment is specified in the document.
Contact:
Roger sp. z o.o. sp.k.
82-400 Sztum
Gościszewo 59
Tel.: +48 55 272 0132 Fax: +48 55 272 0133
Tech. support: +48 55 267 0126
E-mail: support@roger.pl
Web: www.roger.pl
Loading...