Rockwell Collins 8222577 User Manual

MICROWAVE COMPONENTS AND SUBSYSTEMS
Concord, Ontario, CANADA L4K 3Y8
ITS ELECTRONICS INC.
0DU48
200 Edgeley Blvd., Unit #24-27
Tel: (905) 660-0405
Fax: (905) 660-0406
Linear High Power Amplifier
COMPONENT MAINTENANCE MANUAL
WITH
ILLUSTRATED PARTS LIST
ITS Electronics Part Number Rockwell Collins Part Number
PA-1A6-6048-8M 822−2577−XXX
Page 1 of 42
The information contained herein is proprietary to ITS Electronics Inc. and is to be used by the recipient for the sole purpose for which it has been supplied.
XX-XX-XX
It shall not be disclosed, in whole or in part to any other party without the prior written permission of ITS Electronics Inc.
MICROWAVE COMPONENTS AND SUBSYSTEMS
COMPONENT MAINTENANCE MANUAL
PART NUMBER PA-1A6-6048-8M
Revision
Number
Revision
Date
Date
Filed
ITS ELECTRONICS INC.
RECORD OF REVISIONS
By
Page 2 of 42
The information contained herein is proprietary to ITS Electronics Inc. and is to be used by the recipient for the sole purpose for which it has been supplied.
It shall not be disclosed, in whole or in part to any other party without the prior written permission of ITS Electronics Inc.
MICROWAVE COMPONENTS AND SUBSYSTEMS
ITS ELECTRONICS INC.
COMPONENT MAINTENANCE MANUAL
PART NUMBER PA-1A6-6048-8M
RECORD OF TEMPORARY REVISIONS
Temporary
Revision
Number
Issue
Date
Date
Inserted/
Inserted By
Date
Removed/
Removed By
Date
Incorporated
Page 3 of 42
The information contained herein is proprietary to ITS Electronics Inc. and is to be used by the recipient for the sole purpose for which it has been supplied.
It shall not be disclosed, in whole or in part to any other party without the prior written permission of ITS Electronics Inc.
MICROWAVE COMPONENTS AND SUBSYSTEMS
ITS ELECTRONICS INC.
COMPONENT MAINTENANCE MANUAL
PART NUMBER PA-1A6-6048-8M
SERVICE BULLETIN LIST
Service Bulletin /
Revision Number
Issue Date Date
Incorporated
Title
Page 4 of 42
The information contained herein is proprietary to ITS Electronics Inc. and is to be used by the recipient for the sole purpose for which it has been supplied.
It shall not be disclosed, in whole or in part to any other party without the prior written permission of ITS Electronics Inc.
MICROWAVE COMPONENTS AND SUBSYSTEMS
ITS ELECTRONICS INC.
COMPONENT MAINTENANCE MANUAL
PART NUMBER PA-1A6-6048-8M
TABLE OF CONTENTS
SUBJECT TITLE PAGE
Description and Operation 6 Testing and Fault Isolation 12 Automatic Test Requirements Not Applicable Disassembly 24 Cleaning 32 Check 32 Repair 32 Assembly 33 Fits and Clearances Not Applicable Special Tools, Fixtures, and Equipment Not Applicable Illustrated Parts List 39
Page 5 of 42
The information contained herein is proprietary to ITS Electronics Inc. and is to be used by the recipient for the sole purpose for which it has been supplied.
It shall not be disclosed, in whole or in part to any other party without the prior written permission of ITS Electronics Inc.
MICROWAVE COMPONENTS AND SUBSYSTEMS
1 Introduction
ITS ELECTRONICS INC.
This manual provides instructions to perform fault isolation, test and maintenance on the HPA−901B, ITS product P/N: PA-1A6-6048-8M, Rockwell Collins Part Number (RCPN) 822−2577−XXX, linear High Power Amplifier (HPA).
1.1 Abbreviations AMSS Aeronautical Mobile Satellite Services
ARINC Aeronautical Radio, Inc. ATP Acceptance Test Procedures BIT Built-in Test DUT Device under Test HPA High Power Amplifier Hz Hertz ITS ITS Electronics, Inc. LED Light Emitting Diode LRU Line Replaceable Unit MCU Modular Concept Unit MHz Megahertz PC Personal Computer PSMCPT Power Supply, Monitoring, Control and Pilot Tone RAM Random-access Memory RF Radio Frequency RMS Root Mean Square ROM Read-Only Memory SDI Source Destination Identifier SRU Shop Replaceable Unit VA Volt-Ampere VAC Volt Alternating Current VSWR Voltage Standing Wave Ratio W Watt
2 Description and Operation
2.1 General The HPA is an 8-MCU 60 watt (W) L-Band linear high power amplifier. It is
intended for use as part of a system that provides the Aeronautical Mobile Satellite Services (AMSS).
2.2 Electrical Description The HPA will operate from an aircraft supplied power of 115 volt alternating
current (VAC) root mean square (RMS), single phase, 400 hertz (Hz) nominal,
Page 6 of 42
The information contained herein is proprietary to ITS Electronics Inc. and is to be used by the recipient for the sole purpose for which it has been supplied.
It shall not be disclosed, in whole or in part to any other party without the prior written permission of ITS Electronics Inc.
MICROWAVE COMPONENTS AND SUBSYSTEMS
ITS ELECTRONICS INC.
600 volts−amperes (VA) maximum, 500 VA nominal. Its operation frequency range is 1626.5 to 1660.5 megahertz (MHz).
The HPA is a forced-air cooled in accordance with ARINC 600. The architecture, internal layout, front and rear views are shown in Figure 2.1, Figure 2.2 and Figure 2.3. Its front and rear panel connector details are shown in Figure 2.4 and Figure 2.5.
Upon application of power, and at other times when the test mode is commanded via the ARINC 429 serial input bus, the HPA will perform microprocessor RAM and ROM tests. Continuous monitoring of the following functions is performed:
Power Supply
Control Bus Input
RF Power Input
VSWR
Temperature
Four front−panel LED indicators are identified as follows:
OVER TEMP: Illuminated when an overtemperature condition exists (thermal limiting)
POWER SUPPLY FAULT: Illuminated when an internal power supply fault is detected
RF FAULT: Illuminated when an internal RF fault is detected
CONTROLLER FAULT: Illuminated when an internal control function
fault is detected.
The HPA has two external electrical connectors:
Front Panel Connector
Rear Panel Connector
The Front Panel Connector is MS3102 type circular connector. It is not wired or used on the aircraft. This connector is for the HPA testing at the manufacturer or another shop facility. This connector pin-out is indicated as in Figure 2.4.
The Rear Panel Connector is of the “low insertion force, shell size 2” type, as defined in ARINC Specification 600. This connector is wired on the aircraft. It provides main interface with ARINC 429 buses, discrete Mute control and SDI. This connector pin-out is indicated as in Figure 2.5.
Page 7 of 42
The information contained herein is proprietary to ITS Electronics Inc. and is to be used by the recipient for the sole purpose for which it has been supplied.
It shall not be disclosed, in whole or in part to any other party without the prior written permission of ITS Electronics Inc.
MICROWAVE COMPONENTS AND SUBSYSTEMS
ITS ELECTRONICS INC.
Figure 2.1 HPA Architecture and Internal Layout
Page 8 of 42
The information contained herein is proprietary to ITS Electronics Inc. and is to be used by the recipient for the sole purpose for which it has been supplied.
It shall not be disclosed, in whole or in part to any other party without the prior written permission of ITS Electronics Inc.
MICROWAVE COMPONENTS AND SUBSYSTEMS
ITS ELECTRONICS INC.
Figure 2.2 HPA Front View
Figure 2.3 HPA Rear View
Page 9 of 42
The information contained herein is proprietary to ITS Electronics Inc. and is to be used by the recipient for the sole purpose for which it has been supplied.
It shall not be disclosed, in whole or in part to any other party without the prior written permission of ITS Electronics Inc.
MICROWAVE COMPONENTS AND SUBSYSTEMS
Pin Function Internal
A RS-232
Transmit B RS-232 Receive To Controller C RS-232 Ground To Controller
ITS ELECTRONICS INC.
Connection To Controller
Figure 2.4 HPA Front Panel and Test Connector Details
Pin Function
ARINC 429
TP1A
Input A ARINC 429
TP1B
Input B ARINC 429
TP1C
Output A ARINC 429
TP1D
Output B HPA Mute
TP3A
Top/Port A HPA Mute
TP3B
Top/Port B HPA Mute
TP3C
Starboard A HPA Mute
TP3D
Starboard B
TP5A SDI #1 TP5B SDI #2 TP5D SDI Common
Internal Connection
To Controller To Controller
To Controller
To Controller
To Controller
To Controller
To Controller
To Controller
To Controller To Controller To Controller
Figure 2.5 HPA Rear Connector Details
Page 10 of 42
The information contained herein is proprietary to ITS Electronics Inc. and is to be used by the recipient for the sole purpose for which it has been supplied.
TPC1 RF Input To RF Module MPC1 RF Output To RF Module
115 VAC Input
BP1
(Hot) 115 VAC Input
BP7
(Cold)
BP8 Chassis Ground
It shall not be disclosed, in whole or in part to any other party without the prior written permission of ITS Electronics Inc.
To Power Supply
To Power Supply
To Power Supply
MICROWAVE COMPONENTS AND SUBSYSTEMS
ITS ELECTRONICS INC.
2.3 Mechanical Description
The HPA mechanical outline details are described in Figure 2.6 (Drawing Number is ODH4800000).
Figure 2.6 HPA Mechanical Outline The HPA mechanical construction is illustrated in Figure 2.1. The HPA is intended for installations on the aircraft in the Equipment Racks
that are compliant to the requirements of ARINC Specification 600. Therefore, the HPA Enclosure is designed to conform to the ARINC Specification 600. The Enclosure size is 8 Modular Concept Units (8-MCU).
The Enclosure assembly is comprised of:
bottom, left and right side panel/chassis
front panel
rear panel
top panel
two handles
two hold-down hooks
associated hardware
Page 11 of 42
The information contained herein is proprietary to ITS Electronics Inc. and is to be used by the recipient for the sole purpose for which it has been supplied.
It shall not be disclosed, in whole or in part to any other party without the prior written permission of ITS Electronics Inc.
MICROWAVE COMPONENTS AND SUBSYSTEMS
ITS ELECTRONICS INC.
All Enclosure parts are metallic. The panels’ material is aluminum alloy. Interior and bottom surface finish is chemical conversion coating. Exterior (except bottom) surface finish is paint.
The HPA cooling medium is forced air moving through the HPA in the upward or downward direction. To provide the interface between the HPA and the aircraft cooling system, the Enclosure top and bottom panels have air inlet/outlet apertures (sets of multiple individual openings).
The two Shop Replaceable Units are mounted to the sides of the Enclosure. A low insertion force, shell size 2 Connector, as defined in ARINC Specification
600, is mounted to the rear panel. An MS3201 type Connector is mounted to the front panel. The four LEDs are mounted to the front panel. The two handles and two hold-down hooks are mounted to the front panel. The forced air enters either from the inlet of the top lid or from the bottom lid
and goes through the heat sinks of the two SRUs to cool the internal components. The hot air exits from the outlet of the opposite lid.
2.4 The HPA Family Tree and Block Diagram The HPA consists of the following SRUs:
Power Supply, Monitoring, Control and Pilot Tone (PSMCPT) Module (Part No. H4800200)
RF Module (Part No. H4800900)
3 LRU on-line Fault Diagnosis
HPA has BIT to provide seven-byte information for fault diagnosis purpose. The details of the BIT information are in Table 3.1. Each state has its own hex-value “mask” when turned on. The masks of the turned on states aggregate to the hex value of a byte. For example, if “Low Input Power” (mask “02”) and “Input Power Overdrive” (mask “04”) are turned on, the hex value of the first byte will be “06” (i.e. “02”+”04”).
In Table 3.1, only the states marked in the “Fault” column turned on will represent LRU failure.
Page 12 of 42
The information contained herein is proprietary to ITS Electronics Inc. and is to be used by the recipient for the sole purpose for which it has been supplied.
It shall not be disclosed, in whole or in part to any other party without the prior written permission of ITS Electronics Inc.
MICROWAVE COMPONENTS AND SUBSYSTEMS
ITS ELECTRONICS INC.
Flag
Pwr 1
t1 2
t2 3
Ov 4
Uv 5
Byte
No.
Mask
01 Return Loss 02 Low Input Power 04 Input Power Overdrive 08 Output Power Too High X 10 N/A 20 N/A 40 N/A 80 N/A 01 HPA 1 Over-Temp Warning 02 HPA 1 Over-Temp Mute X
HPA 1 Over-Temp
04 08 HPA 1 Under-Temp 10 HPA 2 Over-Temp Warning 20 HPA 2 Over-Temp Mute X
40 80 HPA 2 Under-Temp 01 MCU Over-Temp Warning 02 MCU Over-Temp Mute X
04 08 MCU Under-Temp 10 N/A 20 N/A 40 N/A 80 N/A 01 9V Over-Voltage 02 32V Over-Voltage 04 Spare Over-Voltage 08 N/A
10 20 40
80 N/A 01 9V Under-Voltage 02 32V Under-Voltage 04 Spare Under-Voltage 08 N/A
10 20 N/A
Shutdown X X
HPA 2 Over-Temp Shutdown X X
MCU Over-Temp Shutdown X X
32V Over-Current Measured X X 32V Over-Current Low Cutoff X 32V Over-Current High Cutoff X X
32V Under-Current Measured
Description
Mute +32V Shutdown Fault
Effect
x x
x x x
x x
x
Page 13 of 42