Rockwell Automation TC800 User Manual

TrustedTM
PD-TC800
Trusted
TM
Special I/O Cables
This document provides detailed information for the TC-800 series of TrustedTM I/O Cables. These types of cable provide connection facilities between the Trusted modules and field terminations, for cases which do not fit into the other I/O cable series.
TM
The types of TC-800 Trusted
Cable Type Description
TC-801-02-xmx I/O Companion Slot, Speed Monitor Module to Speed FTAs
The cables are manufactured to user’s requirements, therefore length and type of cable insulation must be specified. Length must be specified to the nearest 0.5m in the format xmx, e.g. 2m0 for a cable length of 2.0m. This detail must be added to the end of the part number. The type of cable insulation forms part of the cable part number and is denoted by 02 for Low Smoke Low Halogen (LSLH), flame retardant to IEC 60332-3 Cat A. PVC covered cables are not available. When ordering cables, it is recommended that the user supplies the details as shown in Table 1.
The maximum recommended I/O cable length is 15m. Cables longer than this may be specified if necessary but may suffer from voltage drop, offset, crosstalk and noise and will present materials handling problems.
Internal cables are designed for cables where they are terminated in adjacent enclosures. If the cable needs to leave the enclosure environment, the External cable has more protection. Note that the ‘External’ cables are not armoured and are not suitable for truly external use and must still be treated with care. These cables will need protection when drawn through a cable route, and should also not be pulled by the connector(s). They should enter cabinets through transit/compression blocks and can not be glanded.
Cables currently available are listed in Table 1 below.
Table 1 TrustedTM I/O Companion Slot Cables
M
T
analogue and digital input/output
Issue 01 Feb 08 PD-TC800 1
Trusted
Issue Record
ssue
I
Number Date Revised by Technical CheckAuthorised by Modification
1 Feb 08 N Owens A Holgate P Stock First Release
TM
Special I/O Cables TC-800
Issue 01 Feb 08 PD-TC800 2
Trusted
TM
Special I/O Cables TC-800
Table of Contents
1. I/O Companion Slot Cable Type TC-801 .....................................................................................6
Figures
Figure 1 I/O Companion Slot Cable Type TC-801-02 ..............................................................................6
Tab le s
M
Table 1 Trusted
T
I/O Companion Slot Cables ........................................................................................1
Issue 01 Feb 08 PD-TC800 3
Loading...