Rockwell Automation T8297 User Manual

SDS-8297
TM
Trusted
Industrial Control System
TrustedTM Output Power Distribution Unit(Diode Protected)-T8297

FEATURES

Supports up to three
Trusted modules
Dual stud power
connection for either single or dual feed
On-board common cathode
diodes for dual dc feeds (AO or low current DO only)
TM
sourcing output

DESCRIPTION

The Trusted 24-120V dc for use with Trusted T8471, 24V dc and 120V dc Digital Output Modules respectively, and T848X Analogue Output Modules obtaining their 0V reference via Trusted Versatile Field Termination Assemblies (VFTAs).
The Unit is designed to be mounted on a DIN rail above the relevant output module I/O connectors.
The Trusted +ve field loop power for the 24-120V dc range of Trusted modules. The output 0V reference and 0V power return is via the Trusted Versatile Field Termination Assemble (VFTA).
Up to three output modules may be supported providing the total load does not exceed the maximum rated capacity of the Unit.
Each supply stud is capable is capable of supplying the maximum rated capacity and can be used in single or dual configuration as required. Dual configuration may be used where the supply is fed via blocking diodes.
Where the total load current for three Trusted Modules is less than 6A, the supply can be fed via the on-board blocking diodes through terminal block TB1. If this method of supply is used, insulating sleeves must be fitted to the redundant power studs.
TM
Output Power Distribution Unit is designed to provide
TM
Output Power Distribution Unit is designed to distribute the
TM
sourcing output modules, e.g. T8451 and
TM
sourcing output
TM
Analogue or Digital Output
TM
TM
Issue 5 Jan 2006
SDS-8297
Trusted
TM
Industrial Control System
TrustedTM Output Power Distribution Unit (Diode Protected)-T8297

BLOCK DIAGRAM

ELECTRICAL SPECIFICATION

Voltage Range Supply Current (via studs) Supply Current (via TB1) Supply Connection +ve (stud) Supply Connection +ve (TB1) Power Output (3-off) Conductor Clamping Range
0 to 140V dc 65A max 6A max 2-off M6 x 25mm studs BLZ 2-part terminal 6-way AMP MATE-N-LOK connector
0.5 to 2.5mm
2
MECHANICAL SPECIFICATION
Dimensions (HxWxD):
70mm x 90mm x 50mm (2.75ins x 3.54ins x
1.97ins)
Weight (fully populated)
100gms (0.22lbs)
ENVIRONMENTAL
Operating Temperature:
-5°C to 60°C (23°F to 140°F)
Operating Humidity:
5 to 95%, non­condensing
Vibration:
10 to 57Hz ±0.075mm 57 to 150Hz 1.0g
Shock:
15g, ½ sine wave, 11ms
EMI (IEC 801):
ESD Air discharge to 15kV. Contact discharge to 8kV
Radiated Fields 10V/m, 27MHz to 500MHz
Transients and Bursts 2kV, 2.5kHz for t=60 seconds
ICS Triplex
Technical data sheets are intended for information and guidance. The Company has a policy of continual product development and improvement. Specifications are subject to change without notice or latest information, visit our Website:- www.icstri plex.c om
Loading...