Rockwell Automation Allen-Bradley FactoryTalk Historian ME Installation Instructions Manual

Page 1
Installation Instructions
Original Instructions
FactoryTalk Historian Machine Edition Module
Catalog Number 1756-HIST2G Series B
Use this document as a guide to install the FactoryTalk® Historian ME Module. This document describes hardware installation only.
For configuration information, refer to the FactoryTalk Historian ME Configuration Guide available on the FactoryTalk Historian ME
Client Tools DVD.
The following table lists the contents of this document and where to find specific information.
Topic See page
Prevent electrostatic discharge 4
North American hazardous location approval 5
Removal and insertion under power (RIUP) cap ability 5
Equipment with lithium battery connections 5
Ethernet network communications connections 5
Technical specifications 6
Identify the module components 6
Prepare the chassis for the module installat ion 8
Determine the module slot location 8
Install the module in the chassis 10
Remove or replace the module 11
Install or remove the module under power 12
Connect the module to the Ethernet network 12
Switch on the chassis 13
Check the power supply and the module status 14
LED indicator information 14
Status LED lights 15
Four-character LED display messages 15
Application status 16
Ethernet port LED information 16
Replace the battery 17
Page 2
FactoryTalk Historian Machine Edition Module, Installation Instructions
Summary of Changes
Topic See page
Equipment with lithium battery connections updated 5
Technical specifications updated 6
Install the module in the chassis updated 10
Four-character LED display messages updated 15
Ethernet port LED information updated 16
2 Rockwell Automation Publication 1756-IN106C-EN-P-January 2018
Page 3
FactoryTalk Historian Machine Edition Module, Installation Instructions
ATTENTION: Read this document and the documents listed in the Addition al Resources section about installation, configuration and operation of this equipment before you install, configure, operate or maintain this product. Users are required to familiarize themselves with installation and wiring instructions in addition to requirements of all applicable codes, laws, and standards. Activities including installation, adjustments, putting into service, use, assembly, disassembly, and maintenance are required to be carried out by suitably trained personnel in accordance with applicable code of practice. If this equipment is used in a manner not specified by the manufacturer, the protection provided by th e equipment may be impaired.
注意:在安装、配置、操作和维护本产品前,请阅读本文档以及其他资源部分列出的有关设备安装、配置和操作的相应文档。除了所有适用规范、法律和标准 的相关要求之外,用户还必须熟悉安装和接线说明。
安装、调整、投运、使用、组装、拆卸维护等各项操作必须由经过适当训练的专业人员按照适用的操作规范实施。 如果未按照制造商指定的方式使用该设备,则可能会损害设备提供的保护。
ATENCIÓN: Antes de instalar, configurar, poner en funcionamiento o realizar el mantenimiento de este producto, lea este documento y los documentos listados en la sección Recursos adicionales acerca de la instalación, configuración y operación de este equipo. Los usuarios deben familiarizarse con las instrucciones de instal ación y cableado y con los requisitos de todos los códigos, leyes y estándares vigentes. El personal debidamente capacitado debe realizar las ac tividades relacionadas a la instalación, ajustes, puesta en servicio, uso, ensamblaje, desens amblaje y mantenimiento de conformidad con el código de práctica aplicable. Si este equipo se usa de una manera no especificada por el fabricante, la protección pro vista por el equipo puede resultar afectada. ATENÇĂO: Leia este e os demais documentos sobre instalaçăo, conf iguraçăo e operaçăo do equipamento que estăo na seçăo Recursos adicionai s antes de instalar, configurar, operar ou manter este produto. Os usuários devem se familiarizar com as instruçőes de instalaçăo e fiaçăo além d as especificaçőes para todos os códigos, leis e normas aplicáveis. É necessário que as atividades, incluindo instalaçăo, aj ustes, colocaçăo em serviço, utilizaçăo, montagem, desmontagem e manutençăo sejam realizadas por pessoal qualificado e especializado, de acordo com o código de prát ica aplicável. Caso este equipamento seja utilizado de maneira năo estabelecida pelo fabric ante, a proteçăo fornecida pelo equipamento pode ficar prejudicada. ВНИМАНИЕ: Перед тем как устанавливать, настраив ать, эксплуатировать или обслуживать данное оборудование, прочитайте этот документ и документы, перечисленные в разделе «Дополнительные ресурсы». В этих документах изложены сведения об установке, настр ойке и эксплуатации данного оборудования. Пользователи обязаны ознакомиться с инструкциями по установке и пр окладке соединений, а также с требованиями всех применимых норм, законов и стандартов. Все действия, включая установку, наладку, ввод в экспл уатацию, использование, сборку, разборку и техническое обслуживание, должны выполнятьс я обученным персоналом в соответствии с применимыми нормами и правилами. Если оборудование используется не предусм отренным производителем образом, защита оборудования может б ыть нарушена.
注意: 本製品を設置、構成、稼動または保守する前に、本書および本機器の設置、設定、操作についての参考資料の該当箇所に記載されている文書に目を通し てください。ユーザは、すべての該当する条例、法律、規格の要件に加えて、設置および配線の手順に習熟している必要があります。 設置調整、運転の開始、使用、組立て、解体、保守を含む諸作業は、該当する実施規則に従って訓練を受けた適切な作業員が実行する必要があります。 本機器が製造メーカにより指定されていない方法で使用されている場合、機器により提供されている保護が損なわれる恐れがあります。
ACHTUNG: Lesen Sie dieses Dokument und die im Abschnitt „Weitere Informationen“aufgeführten Dokumente, die Informationen zu Installation, Konfiguration und Bedienung dies es Produkts enthalten, bevor Sie dieses Produkt installieren, konfigurieren, bedienen oder warten. Anwender müssen sich neben den Bestimmungen aller anwendbaren Vorschriften, Gesetze und Normen zusätzlich mit den Inst allatio machen. Arbeiten im Rahmen der Installation, Anpassung, Inbetriebnahme, Verwendung, Montage, Demontage od er Instandhaltung dürfen nur durch ausreichend geschulte Mitarbeiter und in Übereinstimmung mit den anwendbaren Ausführungsvorschriften vorgenommen werden. Wenn das Gerät in einer Weise verwendet wird, die vom Hersteller nicht vorgesehen ist, kann die Schutzfunktion beeinträchtigt sein. ATTENTION : Lisez ce document et les documents listés dans la section Ressources complémentaires relatifs ŕ l’installation, la configuration et le fonctionnement de cet équipement avant d’installer, configurer, utiliser ou entretenir ce produit. Les utilisateurs doivent se familiariser avec les instructions d’install ation et de câblage en plus des exigences relatives aux codes, lois et normes en vigueur. Les activités relatives ŕ l’installation, le réglage, la mise en se rvice, l’utilisation, l’assemblage, le démontage et l’entretien doivent ętre réalisées par des personnes formées selon le co de de pratique en vigueur. Si cet équipement est utilisé d’une façon qui n’a pas été définie par le fabricant, la protection fournie par l’équip ement peut ętre compromise.
주의: 본 제품 설치, 설정, 작동 또는 유지 보수하기 전에 본 문서를 포함하여 설치, 설정 및 작동에 관한 참고 자료 섹션의 문서들을 반드시 읽고 숙지하십시오. 사용자는 모든 관련 규정, 법규 및 표준에서 요구하는 사항에 대해 반드시 설치 및 배선 지침을 숙지 설치, 조정, 가동, 사용, 조립, 분해, 유지보수 등 모든 작업은 관련 규정에 따라 적절한 교육을 받은 사용자를 통해서만 수행해야 합니다. 본 장비를 제조사가 명시하지 않은 방법으로 사용하면 장비의 보호 기능이 손상될 수 있습니다.
ATTENZIONE Prima di installare, configurare ed utilizzare il prodotto, o effettuare interventi di manutenzione su di esso, leggere il presente documento ed i documenti elencati nella sezione “Altre risorse”, rigu ardanti l’installazione, la configurazione ed il funzionamento dell’apparecchiatura. Gli utenti devono leggere e comprendere le istruzioni di installazione e cablaggio, oltre ai requisiti previsti dalle leggi, codici e standard applicabili. Le attivitŕ come installazione, regolazioni, utilizzo, assemblaggio, disassemblaggio e manutenzione devono essere svolte da personale adeguatamente addestrato, nel rispetto delle procedure previste. Qualora l’apparecchio venga utilizzato con modalitŕ divers e da quanto previsto dal produttore, la sua funzione di protezione potrebbe venire compromessa. DİKKAT: Bu ürünün kurulumu, yapılandırılması, işletilmesi veya bakımı öncesinde bu dokümanı ve bu ekipmanın kurulumu, yapılandırılması ve işletimi ile ilgili İlave Kaynaklar bölümünde yer listelenmiş dokümanları okuyun. Kulla
nıcılar yürürlükteki tüm yönetmelikler, yasalar ve standartların gereksinimlerine ek olarak kurulum ve kablolama talimatlarını da öğrenmek zorundadır. Kurulum, ayarlama, hizmete alma, kullanma, parçaları birleştirme, parçaları s ökme ve bakım gibi aktiviteler sadece uygun eğitimleri almış kişiler tarafından yürürlükteki uygulama yönetmeliklerine uygun şekilde yapılabilir. Bu ekipman üretici tarafından belirlenmiş amacın dışında kullanılırsa, ekipman t arafından sağlanan koruma bozulabilir.
注意事項:在安裝、設定、操作或維護本產品前,請先閱讀此文件以及列於「其他資源」章節中有關安裝、設定與操作此設備的文件。使用者必須熟悉安裝和配線 指示,並符合所有法規、法律和標準要求。 包括安裝、調整、交付使用、使用、組裝、拆卸和維護等動作都必須交由已經過適當訓練的人員進行,以符合適用的實作法規。 如果將設備用於非製造商指定的用途時,可能會造成設備所提供的保護功能受損。
POZOR: Než začnete instalovat, konfigurovat č i provozovat tento výrobek nebo provádět jeho údržbu, přečtěte si tento dokument a dokumenty uvedené v části Dodatečné zdroje ohledně instalace, konfigurace a pr ovozu tohoto zařízení. Uživatelé se musejí vedle požadavků všech relevantních vyhlášek, zákonů a norem nutně seznámit také s pokyny pro instalaci a elekt rické zapojení. Činnosti zahrnující instalaci, nastavení, uvedení do provozu, užívání, montáž, demontáž a údržbu musí vykonávat vhodně proškolený personál v souladu s příslušnými prováděcími předpisy. Pokud se toto zařízení používá způsobem neodpovídajícím specifikaci výrobce, může být narušena ochrana, kterou toto zařízení poskytuje. UWAGA: Przed instalacją, konfiguracją, użytkowaniem lub k onserwacją tego produktu należy przeczytać niniejszy dokument oraz wszystkie dokumenty wymienione w sekcji Dodatkowe źródła omawi ające instalację, konfigurację i procedury użytkowania tego urządzenia. Użytko wnicy mają obowiązek zapoznać się z instrukcjami dotyczącymi instalacji o raz oprzewodowania, jak również z obowiązującymi kodeksami, prawem i normami. Działania obejmujące instalację, regulację, przekazanie d o użytkowania, użytkowanie, montaż, demontaż oraz konserwację muszą być wykonywane przez odp owiednio przeszkolony personel zgodnie z obowiązującym kod eksem postępowania. Jeśli urządzenie jest użytkowane w sposób inny niż okre ślony przez producenta, zabezpieczenie zapewniane przez urządzenie może zostać ograniczone. OBS! Läs detta dokument samt dokumentet, som stĺr listat i avsnittet Övriga resurser, om installation, konfigurering och drift av denna utrustning innan du installerar, konfigurerar eller börjar använda eller utföra underhĺllsarbete pĺ produkten. Användare mĺste bekanta sig med instruktioner för installation och kabeldragning, förutom krav enligt gällande koder, lagar och standarder. Ĺtgärder som installation, justering, service, användning, montering, demontering och underhĺllsarbete mĺste utföras av personal med lämplig utbildning enligt lämpligt bruk. Om denna utrustning används pĺ ett sätt som inte anges av tillverkaren kan det hända att utrustningens skyddsanordningar försätts ur funktion. LET OP: Lees dit document en de documenten die genoemd worden in de paragraaf Aanvull ende informatie over de installatie, configuratie en bediening van deze apparatuur voordat u dit product installeert, configureert, bediend of onderhoudt. Gebruikers moeten zich vertrouwd maken met de installatie en de bedradingsinstructies, naast de vereisten van alle toepasselijke regels, wetten en normen. Activiteiten zoals het installeren, afstellen, in gebruik stellen, gebruiken, monteren, demonteren en het uitvoeren van onderhoud mogen uitsluitend worden uitgevoerd door hiervoor opgeleid personeel en in overeenstemming met de geldende praktijkregels. Indien de apparatuur wordt gebruikt op een wijze die niet is gespecificeerd d oor de fabrikant, dan bestaat het gevaar dat de beveiliging van de apparatuur niet goed werkt.
해야 합니다.
ns- und Verdrahtungsanweisungen vertraut
Rockwell Automation Publication 1756-IN106C-EN-P-January 2018 3
Page 4
FactoryTalk Historian Machine Edition Module, Installation Instructions
ATTENTION: In case of malfunction or damage, no attempts at repair should be made. The module should be returned to the manufacturer for repair. Do not dismantle the module.
ATTENTION: When installed in a 1756 Series C Chassis, this equipment is certified for use only within the surrounding air temperature range of 0…60 °C (32…140 °F). The equipment must not be used outside of this range. When installed in a 1756 Series B Chassis, this equipment is certified for use only within the surrounding air temperature range of 0…50 °C (32…122 °F). The equipment must not be used outside of this range.
ATTENTION: Use only a soft dry anti-static cloth to wipe down equipment. Do not use any cleaning agents.
WARNING: This product contains a type BR1225A lithium battery which may need to be replaced during the life of the product. For instructions on the removal and
replacement of the battery, see "Replace the battery (page 17)". At the end of its life, the battery contained in this product should be collected separately from any unsorted municipal waste. The collection and recycling of batteries helps protect the environment and contributes to the conservation of natural resources as valuable materials are recovered.
Environment and enclosure
ATTENTION: This equipment is intended for use in a Pollution Degree 2 industrial environment, in overvoltage Category II applications (as defined in EN/IEC 60664-1),
at altitudes up to 2000 m (6562 ft) without derating. This equipment is not intended for use in residential environments and may not provide adequate protection to radio communication services in such environments. This equipment is supplied as open-type equipment for indoor use. It must be mounted within an enclosure that is suitably designed for those specific environmental
conditions that will be present and appropriately designed to prevent personal injury resulting from accessibility to live parts. The enclosure must have suitable flame-retardant properties to prevent or minimize the spread of flame, complying with a flame spread rating of 5VA or be approved for the application if nonmetallic. The interior of the enclosure must be accessible only by the use of a tool. Subsequent sections of this publication may contain more information regarding specific enclosure type ratings that are required to comply with certain product safety certifications.
In addition to this publication, see the following: Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1, for more installation requirements. NEMA Standard 250 and EN/IEC 60529, as applicable, for explanations of the degrees of protection provided by enclosures.
Prevent electrostatic discharge
ATTENTION:This equipment is sensitive to electrostatic discharge, which can cause internal damage and affect normal operation. Follow these guidelines when you
handle this equipment:
Touch a grounded object to discharge potential static. Wear an approved grounding wrist strap. Do not touch connectors or pins on component boards. Do not touch circuit components inside the equipment. Use a static-safe workstation, if available. Store the equipment in appropriate static-safe packaging when not in use.
4 Rockwell Automation Publication 1756-IN106C-EN-P-January 2018
Page 5
North American hazardous location approval
FactoryTalk Historian Machine Edition Module, Installation Instructions
The following information applies when operating this equipment in hazardous locations:
Products marked "CL I, DIV 2, GP A, B, C, D" are suitable for use in Class I Division 2 Groups A, B, C, D, hazardous locations and nonhazardous locations only. Each product is supplied with markings on the rating nameplate indicating the hazardous location temperature code. W hen combining products within a system, the most adverse temperature code (low est "T" number) may be used to help determine the overall temperature code of the syst em. Combinations of equipment in your system are subject to investigation by the local Authority Having Jurisdiction at the ti me of installation.
WAR
NING:
Explosion Hazard –
Do not disconnect equipment unless power has been removed or the area is
known to be nonhazardous.
Do not disconnect connections to this
removed or the area is known to be nonhazardous. Secure any external connections that mate to this equipment by using screws, sliding latches, threaded connectors, or other means provided with this product.
Substitut
ion of components may impair suitability for Class I, Division 2. La substitution de composants peut rendre cet équipement inadapté à une
If this produ
ct contains batteries, they must only be changed in an area known
to be nonhazardous.
equipment unless power has been
Informations sur l’utilisation de cet équipement en environnements dangereux:
Les produits marqués "CL I, DIV 2, GP A, B, C, D" ne conviennent qu'à une utilisation en environnements de Classe I Division 2 Groupes A, B, C, D dangereux et non danger eux. Chaque produit est livré avec des marquages sur sa plaque d'identifi cation qui indiquent le code de température pour les environnements dangereux. Lorsque plusieurs produits sont combinés dans un système, le code de température le plus défavorable (code de température le plus faible) peut être utilisé pour déterminer le code de température global du syst ème. Les combinaisons d'équipements dans le système sont sujettes à inspection par les autorit és locales qualifiées au moment de l'installation.
AVER
TISSEMENT:
Risque d’Explosion –
Couper le courant ou s'assurer que l'environnement est classé non dangereux
avant de débrancher l'équipement.
Couper le courant ou s'assurer que l'environnement est classé non dangereux
avant de débrancher les connecteurs. Fixer tous les connecteurs externes reliés à cet équipement à l'aide de vis, loquets coulissa nts, connecteurs filetés ou autres moyens fournis avec ce produit.
utilisation en environnement de Classe I, Division 2.
S'assurer que l'environnement est classé non dangereux avant de changer les
piles.
Removal and insertion under power (RIUP) capability
WARNING: When you insert or remove the module while backplane power is on, an electrical arc can occur. This could cause an explosion in hazardous location
installations. Be sure that power is removed or the area is nonhazardous before proceeding. Repeated electrical arcing causes excessive wear to contacts on both the module and its
mating connector. Worn contacts may create electrical resistance that can affect module operation.
Equipment with lithium battery connections
WARNING: When you connect or disconnect the battery, an electric arc can occur. This could cause an explosion in hazardous location installations. Be sure that the
area is nonhazardous before proceeding. For safety information on the handling of lithium batteries, including handling and disposal of leaking batteries, see Guidelines for Handling Lithium Batteries,
publication AG 5-4.
Ethernet network communications connections
WARNING: If you connect or disconnect the communications cable with power applied to this module or any device on the network, an electrical arc can occur. This
could cause an explosion in hazardous location installations. Be sure that power is removed or the area is nonhazardous before proceeding.
Rockwell Automation Publication 1756-IN106C-EN-P-January 2018 5
Page 6
FactoryTalk Historian Machine Edition Module, Installation Instructions
Technical specifications
The following table contains detailed specifications for installing the module.
Catalog No. 1756-HIST2G Series B
Environmental conditions
Temperature, operating
Temperature, surrounding air, max.
Enclosure type rating
Voltage and current ratings
Power consumption
Wire size
Replacement battery Panasonic BR1225A
North American temp code T5
IEC 60068-2-1 (Test Ad, Operating Cold) IEC 60068-2-2 (Test Bd, Operating Dry Heat)IEC 60068-2-14 (Test Nb, Operating Thermal Shock):
For series C chassis: -25 °C < Ta < +60 °C (-13 °F < Ta < +140 °F)For series B chassis: -25 °C < Ta < +50 °C (-13 °F < Ta < +122 °F)
60 °C (140 °F)
For series B chassis: 50 °C (122 °F)
None (open-style)
5.1 V DC @ 1.4 A
7 Watts
Ethernet connections:
Ethernet cabling and installation according to IEC 61918 and IEC 61 784-5-2
Identify the module components
Use the following figures to identify the external features of the Historian module.
6 Rockwell Automation Publication 1756-IN106C-EN-P-January 2018
Page 7
FactoryTalk Historian Machine Edition Module, Installation Instructions
The Historian module front view
The Historian module as seen from the front view with the four-character LED display, LED indicators (BAT, STS, OK), and Ethernet port locations identified.
The Historian module side view
The Historian module as seen from the side view with the backplane location identified.
Rockwell Automation Publication 1756-IN106C-EN-P-January 2018 7
Page 8
FactoryTalk Historian Machine Edition Module, Installation Instructions
Prepare the chassis for the module installation
Before installing the module, install and connect a ControlLogix chassis and power supply.
Determine the module slot location
It is possible to install the module in any slot in the ControlLogix chassis. Once the FactoryTalk Historian ME module runs in a particular slot, it is not recommended to move the module to a new slot because this may result in the same tags being considered as different points.
There can be a maximum of two FactoryTalk Historian ME modules in a single chassis.
The figure below shows chassis slot numbering in a 4-slot chassis. Slot 0 is the first slot and is always the leftmost slot in the rack (the first slot to the right of the power supply).
8 Rockwell Automation Publication 1756-IN106C-EN-P-January 2018
Page 9
FactoryTalk Historian Machine Edition Module, Installation Instructions
Remove the battery paper tab
The FactoryTalk Historian ME module uses a battery to maintain the real-time clock when there is no power applied to the module. A battery is installed in the module when it ships.
A red paper tab covers the side of the battery that faces the backplane when the module is installed in a chassis.
Before installing the module, remove the battery paper tab by pulling it off.
Rockwell Automation Publication 1756-IN106C-EN-P-January 2018 9
Page 10
FactoryTalk Historian Machine Edition Module, Installation Instructions
Install the module in the chassis
To install the module in the chassis
1. Align the circuit board with the top and bottom guides in the chassis.
2. Slide the module into the chassis. Make sure the
3. Make sure the mo
dule is aligned with the power supply or other installed modules.
module backplane connector properly connects to the chassis.
10 Rockwell Automation Publication 1756-IN106C-EN-P-January 2018
Page 11
Remove or replace the module
To remove or replace the module
1. Push on the upper and lower module tabs to disengage them.
FactoryTalk Historian Machine Edition Module, Installation Instructions
2. Slide the module
IMPORTANT
If you are replacing an existing module with an identical one, and you want to resume identical system operation, you must install the new module in the same slot.
out of the chassis.
Rockwell Automation Publication 1756-IN106C-EN-P-January 2018 11
Page 12
FactoryTalk Historian Machine Edition Module, Installation Instructions
Install or remove the module under power
This module is designed to be installed or removed while chassis power is applied. It is recommended to stop all data collection services before removing the module.
WARNING: When you insert or remove a module while backplane power is on, an electrical arc may occur. An electrical arc can cause personal injury or property damage by:
Sending an erroneous signal to your system’s field device causing unintended machine motion or loss of process control. Causing an explosion in a hazardous environment.
Repeated electrical arcing causes excessive wear to contacts on both the module and its mating connector. Worn contacts may create electrical resistance that can affect module operation.
Connect the module to the Ethernet network
WARNING: If you connect or disconnect the Ethernet cable with power applied to this module or any device on the network, an electrical arc can occur. This could cause
an explosion in hazardous location installations. Be sure that power is removed or the area is nonhazardous before proceeding.
To connect the module to the Ethernet network, attach the RJ45 connector to the Ethernet port on the front of the module as shown.
IMPORTANT
It is recommended to connect the module to the network via a 100 MB or 1GB Ethernet switch, which reduces collisions and lost packets, and increases network bandwidth. For detailed Ethernet connection information, refer to the ControlLogix Ethernet/IP Bridge Module Installation Instructions.
12 Rockwell Automation Publication 1756-IN106C-EN-P-January 2018
Page 13
Switch on the chassis
To switch on the chassis
1. Locate the power switch inside the power supply.
2. Set the switch to the ON position as shown. Power will be applied to the chassis.
FactoryTalk Historian Machine Edition Module, Installation Instructions
Rockwell Automation Publication 1756-IN106C-EN-P-January 2018 13
Page 14
FactoryTalk Historian Machine Edition Module, Installation Instructions
Check the power supply and the module status
Check the LED indicators and the four-character LED display to determine if the power supply and module are operating properly.
It can take up to four to five minutes for the module to become fully operational once power is applied.
NOTE
LED indicator information
The LED indicators determine if the power supply and module are operating properly.
There are the following LED indicators on the front panel of the Historian ME module:
Status LED lights (page 15).
Four-character LED display messages (page 15).
14 Rockwell Automation Publication 1756-IN106C-EN-P-January 2018
Page 15
FactoryTalk Historian Machine Edition Module, Installation Instructions
Status LED lights
The Status LED lights provide the following information:
LED light On power up Status Description
BAT Actual indication of battery condition. Indicates battery status.
STS Off Indicates application status. See
OK Green Indicates module status. Single bi-color red/green LED.
"Application status (page 16)" for status descriptions.
This LED is currently not operational in the series B module.
Single bi-color red/green LED.
Flashing r ed indicates that data collection is active but data
transfer is inactive.
Solid r ed indicates that data collection is inactive. Check the
interface or scrolling text on the display for more information.
Flashing green indicat es that data collection is active but
data transfer is not configured.
Solid green indicates that both data collection and data
transfer are active.
Red indicate s that a major fault has occurred in th e module. Green in dicates that the module is operating normally.
Four-character LED display messages
The four-character LED display provides system status messages in a static and/or scrolling string on the front panel of the Historian ME module. Once an application is started, it has the responsibility of controlling this display.
The four-character LED display provides the following information:
Process or component Four-character display message Description
Startup or reset Diagnostic codes (hexadecimal values) Displays for several seconds when initializing sta rtup or reset.
Startup or reset INIT Displays for several seconds when initializing sta rtup or reset.
Startup or reset OK Displays for several seconds if the initialization of all major
Shutting down SHUTTING DOWN Displays during the shutdown process.
Shutdown SHUT DOWN Displays when the shutdown is finished.
Ethernet port LAN OK Displays if the Ethernet port is configured and the IP address is
Ethernet port LAN LOST Displays for several seconds if the Ethernet port fails to acquire the
software components was successful.
acquired properly. After the "LAN OK" displays, the IP address displays.
IP address. After “LAN LOST” displays, the MAC address displays.
Rockwell Automation Publication 1756-IN106C-EN-P-January 2018 15
Page 16
FactoryTalk Historian Machine Edition Module, Installation Instructions
Process or component Four-character display message Description
Application subsystems The configuration status:
Not configu red
See "Application status (page 16)" for detailed inform ation about the application subsystems.
No points
The data collection status:
C ollect ok Idl e Collect stopped
The data transfer status:
Upload o k Upload stopped No upload
The data storage status:
Storage crit ical Storage full
Application status
The application status is composed of four application subsystems, as described in the following table.
If more than one of the four statuses exist, they display consecutively with two-second duration between each message.
NOTE
Application subsystem Status Description
The configuration status A. Not configured
B. No points
The "Not conf igured" status displays if neither the data transfer nor the data collection is configured.
Otherwise, the status is empty.
The "No point s" status displays if the data collection is not configured, but the data transfer is configured.
Otherwise, the status is empty.
Notes:
The dat a collection is not configured if the number of subscribed points from the data server is zero (0). The dat a transfer is not configured if the SE Host Server Name or IP address is not entered or is not resolved.
The status is “No upload".
The data collection status A. Collect ok
B. Collect stopped
The data transfer status A. Upload ok
B. Upload stopped
The data storage status A. Storage critical
B. Storage full
The "Collect ok" status displays if the data collection is active and properly configured. The "Collect stopped" status displays if the data collection is configured but not active.
The "Uplo ad ok" status displays if the data transfer is active and configured. The "Uplo ad stopped" status displays if the data transfer is configured but not active, and the data
collection status is not “idle”. Otherwise, the data transfer status is empty.
The "Stora ge critical" status displays if Data Storage reaches 50% capacity (default value for the first
threshold).
The "Stora ge full" status displays if Data Storage reaches 75% capacity (default value for the secon d
threshold). Otherwise, the Data Storage status is empty.
Ethernet port LED information
The Ethernet port LED on the 10/100/1000 BASET connector supports IEEE 802.3.
The following table summarizes the Ethernet port LED functions.
16 Rockwell Automation Publication 1756-IN106C-EN-P-January 2018
Page 17
FactoryTalk Historian Machine Edition Module, Installation Instructions
LED function LED color LED state Description
Link speed Green/Orange Off 10 Mbps link speed
Green 100 Mbps link speed
Orange 1000 Mbps link speed
Link status and activity Yellow Off No link
Steady on Link established, no activity detected
Blinking Link established, activity detected
Replace the battery
The FactoryTalk Historian ME module uses a battery to maintain the real-time clock when there is no power applied to the module. A battery is installed in the module when it ships.
It is possible to replace the battery if necessary. The battery is a Panasonic TYPE BR1225A coin type lithium battery. Replacement batteries are commercially available.
Battery life depends on how much time the module is not powered. When the module is
NOTE
installed in a powered ControlLogix chassis, it does not use the battery, which results in greater battery life.
When replacing the battery, the module's date and time may be restored to the initial values. If this occurs and the module restarts, it starts in safe mode.
To replace the battery
1. Pull the white plastic battery holder from the back of the module.
If necessary, pull the holder out far enough to use a small screwdriver to take out the battery. In this case, insert the screwdriver from the side of the battery that faces the module printed circuit board.
IMPORTANT
There are metal guides that hold the battery holder in place. Do not attempt to remove the metal guides.
2. Remove the old battery from the holder.
Rockwell Automation Publication 1756-IN106C-EN-P-January 2018 17
Page 18
FactoryTalk Historian Machine Edition Module, Installation Instructions
3. Insert a new battery into the holder.
IMPORTANT
Before inserting a new battery, make sure of correct orientation. The battery side with words and numbers needs to face away from the printed circuit board. Incorrect battery orientation may lead to damage to the battery holder.
The following pictures show the correct battery orientation.
Top side view:
Bottom side view:
4. Reinstall the battery holder in the back of the module.
Install first the narrower part of the holder into the metal guides.
TIP
5. Push the battery holder all the way into the back of the module.
18 Rockwell Automation Publication 1756-IN106C-EN-P-January 2018
Page 19
FactoryTalk Historian Machine Edition Module, Installation Instructions
Additional resources
These documents contain additional information concerning related products from Rockwell Automation.
Resource Description
FactoryTalk Historian ME Configuration Guide, publicat ion 1756-UM106 (http://search.rockwellautomation.com/search?q=+1756-UM106&inbound=All&r equiredfields=&
client=literature&filter=0&ie=UTF-8&oe=UTF-8&output =xml_no_dtd&proxystylesheet=literatu re&site=literature&getfields=*&lang=en&hl=e n&sitelang=en&dnavs=+1756-UM106)
Industrial Automation Wiring and Grounding Guidelines, publication 177 0-4.1 (http://literature.rockwellautomation.com/idc/groups/lit erature/documents/in/1770-in041_-en-p.
pdf)
Product Certifications website,
https://www.rockwellautomation.com/global /certification/overview.page
You can view or download publications at https://www.rockwellautomation.com/global/literature-library/overview.page. To order paper copies of technical documentation, contact your local Allen-Bradley distributor or Rockwell Automation sales representative.
Describes how to use the FactoryTalk Historian ME module.
Provides general guidelines for installin g a Rockwell Automation industrial system.
Provides declarations of conformity, certificates, and other c ertification details.
Rockwell Automation Publication 1756-IN106C-EN-P-January 2018 19
Page 20
Rockwell Automation Support
Use the following resources to access support information.
Technical Support Center
Local Technical Support Phone Numbers
Direct Dial Codes
Literature Library
Product Compatibility and Download Center (PCDC)
Knowledgebase Articles, How-to Videos, FAQs, Chat, User Forums, and Product Notification Updates.
Locate the phone number for your country. http://www.rockwellautomation.com/global/support/get-support-now.page
Find the Direct Dial Code for your product. Use the code to route your call directly to a technical support engineer.
Installation Instructions, Manuals, Brochures, and Technical Dat a. http://www.rockwellautomation.com/global/literature-library/ove rview.page
Get help determining how products interact, check features and capabilities, and find associated firmware.
https://rockwellautomation.custhelp.com/
http://www.rockwellautomation.com/global/support/direct-dial.page
http://www.rockwellautomation.com/global/support/pcdc.page
Documentation Feedback
Your comments will help us serve your documentation needs better. If you have any suggestions on how to improve this document, complete the How Are We Doing? form at http://literature.rockwellautomation.com/idc/groups/literature/documents/du/ra-du002_-en-e.pdf.
Rockwell Automation maintains current product environmental information on its website at http://www.rockwellautomation.com/rockwellautomation/about-us/sustainability-ethics/product-environmental-compliance.page.
A
llen-Bradley, FactoryTalk, Rockwell Automation, and Rockwell Software are trademarks of Rockwell Automation, Inc.
Trademarks not belonging to Rockwell Automation are property of their respective companies.
Rockwell Automation Publication 1756-IN106C-EN-P-January 2018 PN-482254
Supersedes Publication 1756-IN106B-EN-P-April 2015 Copyright © 2018 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A.
Loading...