Rockwell PanelView Plus 7 Standard Technical Data

Technical Data
PanelView Plus 7 Standard Terminals
Catalog Numbers 2711P-T4W21D8S, 2711P-T4W22D8S, 2711P-T4W21D8S-B, 2711P-T4W22D8S-B, 2711P-T6C21D8S,
2711P-T6C22D8S, 2711P-T6C21D8S-B, 2711P-T6C22D8S-B, 2711P-T7C21D8S, 2711P-T7C22D8S, 2711P-T7C21D8S-B, 2711P-T7C22D8S-B, 2711P-T9W21D8S, 2711P-T9W22D8S, 2711P-T9W21D8S-B, 2711P-T9W22D8S-B, 2711P-T10C21D8S, 2711P-T10C22D8S, 2711P-T10C21D8S-B, 2711P-T10C22D8S-B, 2711P-T12W21D8S, 2711P-T12W22D8S, 2711P-T12W21D8S-B, 2711P-T12W22D8S-B, 2711P-T15C21D8S, 2711P-T15C22D8S, 2711P-T15C21D8S-B, 2711P-T15C22D8S-B
Top ic Pa ge
Summary of Changes 1
Environmental Specifications 2
Certifications 3
Technical Specifications 4
Product Dimensions 7
HMI Software 8
Additional Resources 8

Summary of Changes

Top ic Pa ges
Corrected the dimensions of the 12-inch terminal. 6, 7
The PanelView Plus 7 Standard terminals include these features:
Terminal functionality permits connection to 1 controller, up to 100 screens, and up to 500 alarms.
FactoryTalk® View Machine Edition software provides a familiar environment for creating HMI applications.
Windows CE operating system with desktop access for configuration and third-party applications.
Ethernet communication that supports linear and star network topology.
PDF viewer to access PDF files that are stored on the terminal.
More screen options including 4-in., 6-in., 7-in., 9-in., 10-in., 12-in., and 15-in. terminals.
PanelView Plus 7 Standard Terminals
Widescreen on three sizes, 4-in., 9-in., and 12-in. terminals.
Greater screen resolution.
Terminals are available with an Allen-Bradley brand marking, or with no marking for customers who want to put
their own brand label on the terminal.
Certifications including Class I, Div. 2; Class II, Div. 2; Class III; and ATEX, IECEx, and INMETRO Zones 2 and 22.

Environmental Specifications

Table 1 - Environmental Specifications - 2711P-T4W21D8S, 2711P-T4W22D8S, 2711P-T4W21D8S-B, 2711P-T4W22D8S-B, 2711P-T6C21D8S, 2711P-T6C22D8S, 2711P-T6C21D8S-B, 2711P-T6C22D8S-B, 2711P-T7C21D8S, 2711P-T7C22D8S, 2711P-T7C21D8S-B, 2711P-T7C22D8S-B, 2711P-T9W21D8S, 2711P-T9W22D8S, 2711P-T9W21D8S-B, 2711P-T9W22D8S-B, 2711P-T10C21D8S, 2711P-T10C22D8S, 2711P-T10C21D8S-B, 2711P-T10C22D8S-B, 2711P-T12W21D8S, 2711P-T12W22D8S, 2711P-T12W21D8S-B, 2711P-T12W22D8S-B, 2711P-T15C21D8S, 2711P-T15C22D8S,
2711P-T15C21D8S-B, 2711P-T15C22D8S-B
Attribute Value
Temperature, operating 0…55 °C (32…131 °F)
Temperature, nonoperating -25…+70 °C (-13…+158 °F)
Relative humidity 5…95% without condensation
Heat dissipation 4 in., 15 W = 51 BTU
Altitude, operating 2000 M
Vibration
4.3-in., 5.7-in., 6.5-in., 9.0-in., 10.4-in., 12.1-in., and 15-in.
Shock, operating 15 g at 11 ms
Shock, nonoperating 30 g at 11 ms
Enclosure ratings NEMA and UL Type 12, 13, 4X (indoor use only), also rated IP54 or IP66 as Classified by
(1)
6 in., 15 W = 51 BTU 7 in., 15 W = 51 BTU 9 in., 20 W = 68 BTU 10 in., 20 W= 68 BTU 12 in., 30 W= 102 BTU 15 in., 30 W= 102 BTU
0.012 pk-pk, 10…57 Hz 2g peak at 57…500 Hz
UL
(1) Catalog numbers with a -B extension denote terminals that do not include the Allen-Bradley brand marking. Customers can put their own brand labels on these
terminals.
2 Rockwell Automation Publication 2711P-TD008I-EN-P - March 2021
PanelView Plus 7 Standard Terminals

Certifications

Table 2 Certifications - 2711P-T4W21D8S, 2711P-T4W22D8S, 2711P-T4W21D8S-B, 2711P-T4W22D8S-B, 2711P-T6C21D8S, 2711P-T6C22D8S, 2711P-T6C21D8S-B, 2711P-T6C22D8S-B, 2711P-T7C21D8S, 2711P-T7C22D8S, 2711P-T7C21D8S-B, 2711P-T7C22D8S-B, 2711P-T9W21D8S, 2711P-T9W22D8S, 2711P-T9W21D8S-B, 2711P-T9W22D8S-B, 2711P-T10C21D8S, 2711P-T10C22D8S, 2711P-T10C21D8S-B, 2711P-T10C22D8S-B, 2711P-T12W21D8S, 2711P-T12W22D8S, 2711P-T12W21D8S-B, 2711P-T12W22D8S-B, 2711P-T15C21D8S, 2711P-T15C22D8S, 2711P-T15C21D8S-B,
2711P-T15C22D8S-B
(1)
Certification
IECEx IEC 60079-0; IEC 60079-7; IEC 60079-11; and IEC 60079-31
CCC Ex GB 3836.1-2010; GB 3836.3-2010; GB 3836.4-2010; GB 12476.1-2013;
cULus cULus Listed Industrial Control Equipment for use in Hazardous Locations (E10314)
ATEX European Union 94/9/EC ATEX Directive, compliant with:
INMETRO ABNT NBR IEC 60079-0
CE (EMC) European Union 2004/108/EC EMC Directive, compliant with:
CE (LVD) European Union 2006/95/EC Low Voltage Directive,
RCM Australian Radio Communications Act, compliant with:
EAC Certificate of compliance
RoHS China RoHS, Turkey RoHS, European RoHS
KCC Ce rtificate of complia nce
(2)
Value
II 3 GD Ex ec ic IIC T4 Gc Ex tc IIIC T135 °C (275 °F) Dc IP66 Tamb = 0 °C… +55 °C (32 °F…131 °F) IECEx UL 20.0046X
GB 12476.5-2013 Ex ec ic IIC T4 Gc Ex tc IIIC T135 °C (275 °F) Dc IP66 Tamb = 0 °C…+55 °C (32 °F…131 °F)
per standards ANSI / ISA 12.12.01 and CSA C22.2 No. 213. rated:
Class I, Division 2, Groups A, B, C and D
Class II, Division 2, Groups F and G
Class III
Enclosure type ratings per UL50 and CSA C22.2 No. 94.2-07. Enclosure ingress protection classified by UL per IEC 60529
EN 60079-0; EN 60079-7; EN 60079-11; and EN 60079-31
II 3 GD
Ex ec ic IIC T4 Gc
Ex tc IIIC T135 °C (275 °F) Dc IP66
Tamb = 0 °C …+55 °C (32 °F …+131 °F)
DEMKO 14 ATEX 1302X
ABNT NBR IEC 60079-8 ABNT NBR IEC 60079-11 ABNT NBR IEC 60079-31 Ex ec ic IIC T4 Gc Ex tc IIIC T135 °C (275 °F) Dc IP66 Tamb = 0 °C …+55 °C (32 °F …+131 °F) UL-BR 14.0716X
EN 61000-6-2; Industrial Immunity
EN 61000-6-4; Industrial Emissions
EN 61131-2; Programmable Controllers
compliant with:
EN 61131-2; Programmable Controllers
AS/NZS CISPR 11; Industrial Emissions
(1) Catalog numbers with a -B extension denote terminals that do not include the Allen-Bradley brand marking. Customers can put their own brand labels on these
terminals.
(2) When marked. See the Product Certification link on http://www.ab.com for declarations of conformity, certificates, an d other certific ation details.
Rockwell Automation Publication 2711P-TD008I-EN-P - March 2021 3
Loading...
+ 7 hidden pages