Rockford Fosgate R150X2, R250X1, R250X4, R300X4, R400-4D Installation & Operation Manual

...
Installation & Operation
AMPLIFIERS
R150X2 R250X1
R250X4 R300X4 R400-4D
R750-1D R1200-1D
R500X1D R600-4D R600X5
Installation assistance availible at:
www.rockfordfosgate.com/rftech
Direct: (480) 967-3565 • Toll Free: (800) 669-9899
600 South Rockford Drive • Tempe, Arizona 85281 United States
AMPLIFIERS
R150X2 R250X1
R250X4 R300X4 R400-4D
R500X1D R600-4D R600X5
R750-1D R1200-1D
Installation & Operation
Installation assistance availible at:
If, after reading your manual, you still have questions regarding this prod­uct, we recommend that you see your Rockford Fosgate dealer. If you need further assistance, you can call us direct at 1-800-669-9899. Be sure to have your serial number, model number and date of purchase available when you call.
Safety
This symbol with “WARNING” is intended to alert the user to the presence of important in­structions. Failure to heed the instructions will result in severe injury or death.
This symbol with “CAUTION” is intended to alert the user to the presence of important in­structions. Failure to heed the instructions can result in injury or unit damage.
•To prevent injury and damage to the unit, please read and follow the instructions in this manual. We want you to enjoy this system, not get a headache.
•If you feel unsure about installing this system yourself, have it installed by a qualified Rockford Fosgate technician.
•Before installation, disconnect the battery negative (-) terminal to prevent damage to the unit, fire and/or possible injury.
Introduction
Specications
PRACTICE SAFE SOUND
Continuous exposure to sound pressure levels over 100dB may cause
permanent hearing loss. High powered auto sound systems may
produce sound pressure levels well over 130dB. Use common sense
and practice safe sound.
PRATIQUEZ UNE ÉCOUTE SANS RISQUES
Une exposition continue à des niveaux de pression acoustique upérieurs à 100 dB peut causer une perte d’acuité auditive permanente. Les systèmes
audio de forte puissance pour auto peuvent produire des niveaux de
pression acoustique bien au-delà de 130 dB. Faites preuve de bon sens et
pratiquez une écoute sans risques
PRACTIQUE EL SONIDO SEGURO
El contacto continuo con niveles de presión de sonido superiores a 100 dB puede causar la pérdida permanente de la audición. Los sistemas de
sonido de alta potencia para automóviles pueden producir niveles de
presión de sonido superiores a los 130 dB. Aplique el sentido común y
practique el sonido seguro.
PRAKTIZIEREN SIE SICHEREN SOUND
Fortgesetzte Geräuschdruckpegel von über 100 dB können beim
Menschen zu permanentem Hörverlust führen. Leistungsstarke
Autosoundsysteme können Geräuschdruckpegel erzeugen, die weit über
130 dB liegen. Bitte wenden Sie gesunden Menschenverstand an und
praktizieren Sie sicheren Sound.
OSSERVATE LE REGOLE DEL SUONO SENZA PERICOLI
La costante esposizione a livelli di pressione acustica al di sopra dei
100dB possono causare la perdita permanente dell’udito. I sistemi
audio ad alta potenza possono produrre livelli di pressione acustica ben
superiori ai 130dB. Si consiglia il buon senso e l’osservanza delle regole
del suono senza pericoli
CEA 2006
Power ratings on Rockford Fosgate amplifiers conform to CEA-2006 industry standards. These guidelines
mean your amplifier’s output power ratings are REAL POWER numbers, not inflated marketing ratings.
Mode R150X2 R250X4 R300X4 R400-4D R600-4D R600X5 R250X1 R500X1D R750-1D R1200-1D
Rated Power -
Continuous
Power Rating
(RMS) Measured
@ 14.4V
50x2 @ 4 ohms
75x2 @ 2 ohms
150x1 @ 4 ohms*
40x4 @ 4 ohms
60x4 @ 2 ohms
125x2 @ 4 ohms*
50x4 @ 4 ohms
75x4 @ 2 ohms
150x2 @ 4 ohms*
75x4 @ 4 ohms
100x4 @ 2 ohms
200x2 @ 4 ohms*
100x4 @ 4 ohms
150x4 @ 2 ohms
300x2 @ 4 ohms*
50x4 @ 4 ohms
75x4 @ 2 ohms
150x2 @ 4 ohms*
Sub: 200x1 @ 4 ohms
Sub: 300x1 @ 2 ohms
150x1 @ 4 ohms
250x1 @ 2 ohms
300x1 @ 4 ohms
500x1 @ 2 ohms
250x1 @ 4 ohms
500x1 @ 2 ohms
750x1 @ 1 ohm
400x1 @ 4 ohms
800x1 @ 2 ohms
1200x1 @ 1 ohm
Crossover
Slope
12 dB/Oct 12 dB/Oct 12 dB/Oct 12 dB/Oct 12 dB/Oct 12 dB/Oct 12 dB/Oct 12 dB/Oct 12 dB/Oct 12 dB/Oct
Crossover
Frequency
Variable 50Hz-250Hz Variable 50Hz-250Hz Variable 50Hz-250Hz Variable 50Hz-250Hz Variable 50Hz-250Hz Variable 50Hz-250Hz Variable 50Hz-250Hz Variable 50Hz-250Hz Variable 50Hz-250Hz
SS: 15Hz-40Hz
Variable 50Hz-250Hz
SS: 15Hz-40Hz
Punch EQ
Variable 0 -
+
12dB @
45Hz
Selectable 0/
+
6dB/
+
12dB
@ 45Hz
Selectable 0/
+
6dB/
+
12dB
@ 45Hz
Variable 0 -
+
18dB @
45Hz
Variable 0 -
+
18dB @
45Hz
Selectable 0/
+
6dB/
+
12dB
@ 45Hz
Sub: Variable 0 -
+
12dB
@ 45Hz
Variable 0 -
+
12dB @
45Hz
Variable 0 -
+
12dB @
45Hz
Variable 0 -
+
18dB @
45Hz
Variable 0 -
+
18dB @
45Hz
Operating
Voltage
9-16VDC 9-16VDC 9-16VDC 9-16VDC 9-16VDC 9-16VDC 9-16VDC 9-16VDC 9-16VDC 9-16VDC
Frequency
Response
20Hz-20kHz 20Hz-20kHz 20Hz-20kHz 20Hz-20kHz 20Hz-20kHz 20Hz-20kHz 20Hz-250Hz 20Hz-250Hz 20Hz-250Hz 20Hz-250Hz
Battery Fuse
Rating (not
supplied)
20A 50A 50A 50A 100A 80A 30A 50A 100A 150A
THD+N @
Rated Power
<1.0% @ 4 ohms
<1.0% @ 2 ohms
<1.0% @ 4 ohms
<1.0% @ 2 ohms
<1.0% @ 4 ohms
<1.0% @ 2 ohms
<1.0% @ 4 ohms
<1.0% @ 2 ohms
<1.0% @ 4 ohms
<1.0% @ 2 ohms
F/R:
<1.0% @ 4 ohms
<1.0% @ 2 ohms
Sub:
<1.0% @ 4 ohms
<1.0% @ 2 ohms
<1.0% @ 4 ohms
<1.0% @ 2 ohms
<1.0% @ 4 ohms
<1.0% @ 2 ohms
<1.0% @ 4 ohms
<1.0% @ 2 ohms
<1.0% @ 1 ohm
<1.0% @ 4 ohms
<1.0% @ 2 ohms
<1.0% @ 1 ohm
Input Sensitivity
150mV-4V Low Level
450mV-12V High Level
150mV-4V Low Level
450mV-12V High Level
150mV-4V Low Level
450mV-12V High Level
150mV-4V 150mV-4V 150mV-4V Low Level
450mV-12V High Level
150mV-4V Low Level
450mV-12V High Level
150mV-4V Low Level
450mV-12V High Level
150mV-4V 150mV-4V
Input Imped-
ance
20k 20k 20k 20k 20k 20k 20k 20k 20k 20k
S/N Ratio CEA
2006
>80dB >80dB >80dB >70dB >70dB F/R: > 80dB
Sub: >80dB
>80dB >80dB >75dB >75dB
S/N Ratio @
Rated Power
>100dB >100dB >100dB >90dB >90dB F/R: >100dB
Sub: >100dB
>100dB >100dB >100dB >100dB
Channel
Separation
>50dB >50dB >50dB >50dB >50dB >50dB N/A N/A N/A N/A
Common Mode
Rejection Ratio
>40dB >55dB >40dB >55dB >55dB >55dB >40dB >55dB >55dB >55dB
Damping Factor
>200dB >200dB >200dB >200dB >200dB F/R: >200dB
Sub: >200dB
>200dB >200dB >200dB >200dB
Dimensions
(LxWxH)
11.2”
x
6.8”
x
2”
(28.5cm x 17.2cm x 5.1 cm)
11.2”
x
6.8”
x
2”
(28.5cm x 17.2cm x 5.1 cm)
13.2”
x
6.8”
x
2”
(33.5cm x 17.2cm x 5.1 cm)
9.1”
x
6.8”
x
2”
(23.1cm x 17.2cm x 5.1 cm)
11.1”
x
6.8”
x
2”
(28.2cm x 17.2cm x 5.1 cm)
13.2”
x
6.8”
x
2”
(33.5cm x 17.2cm x 5.1 cm)
11.2”
x
6.8”
x
2”
(28.5cm x 17.2cm x 5.1 cm)
8.5”
x
6.8”
x
2”
(21.6cm x 17.2cm x 5.1 cm)
9.1”
x
6.8”
x
2”
(23.1cm x 17.2cm x 5.1 cm)
11.1”
x
6.8”
x
2”
(28.2cm x 17.2cm x 5.1 cm)
* Rated power when amplifier is wired in a bridged configuration.
Loading...