Robus RVA96302050, RVA96402050 Installation Instructions

VEGAS 9.6W/M, 24V, 120LED/M, LED STRIP LIGHT, 3000K/4000K, IP20, 50M
RVA96302050 RVA96402050
PLEASE READ INSTRUCTION BEFORE COMMENCING INSTALLATION AND RETAIN FOR FUTURE REFERENCES. ! Electrical products can cause death or injury, or damage to property. If in any doubt about the installation or use of this product, consult a competent electrician Note: Product technical information and specification may change over time without prior notification. For the latest technical information please visit our web site www.robus.com.au
-20°C < Ta < +40°C, DC 24V, Class III, IP20 Suitable for mounting on a normally flammable surface.
Installation
1. Ensure mains supply is switched off before commencing work.
2. Cut the LED strip to the required length at the locations marked on the strip (Every 6 LED’s).
3. Connector for this LED strip is the RVA96-CONNP. Please select the most appropriate connector. There are no markings on the connector. With the brown part on the bottom extend the connector. Insert the LED strip. Ensure Red cable is on the “+” side and the Black cable is on the “-“. Retract the brown part of the connector and ensure it is secure. (Note that when the wire connector is used to connect to AMP or extending the strip the connection sequence will be reversed on the opposite side of the connection).
3. Mounting the Strip: Self-adhesive strip: Remove the protective film to reveal adhesive strip. Place the strip onto the desired location and press down firmly. Ensure the strip is secure.
5. Please see installation diagram and choose the most suitable installation method. Note: When connected in series it is not possible to extend the strip to lengths longer than 10m. However, strips may be connected in parallel up to the max rating of the power supply used
6. Connect the strips to the driver (choose the correct 24V driver based on the length of the strip). Please use IP box for the connection.
7. When attaching the connector to the LED strip ensure that wiring sequence is correct and that the strip is secure
8. Care must be taken to ensure the correct wiring sequence.
Note: Please take care not to damage the LEDs, during installation.
The Installation must be carried out by a qualified electrician
Single-CTRL & Single-AMP
Driver
DC+
DC-
V +
Single-CRTL
24V +
_
1 2
RVA96-CONNP
Driver
Single-CRTL
DC+
DC-
3 4
_
_
_
Driver
V +
_
V
_
V
_
V
LED Group Australasia 9/210 Queensport Road North Tel: 07 3890 5444 Murarrie Fax: 07 3890 4777 QLD 4172 Email: purchases@robus.com Australia Website: www.robus.com.au
LED Group Crowe Hogwarth Tel: +64 0508 533 335 72 Trafalgar Square Email: nz_purchases@robus.com NELSON 7010 Website: www.robusled.co.nz New Zealand
Issue 1 110119
DC+ DC-
W/CH1
V+ W/CH1
C/CH2
C/CH2
Single-AMP
V+
5