Robotouch RBT03 User Manual

robotouch.
RBTO3
Foldable
Motorized
Treadmill
illli5
_t16
rj5
.
Rated voltage:
8.3A
.
Motorpower:1500W
.
Scope of operating speed:
1
-
1 4
(km/h)
.
Scopeoftimedisplay:0:00-99:59
(min:
s)
o
Scope
of distance display: 0.00-99.9
(km)
.
Scopeofheartrate:50-200
(bpm)
.
Scopeof
caloriedisplay: 0-999
(calories)
.
Floorarea: 165X74x132cm
.
Effective
usable
floor area: 122x
42
cm
Features
X Oversized blue-backlight
LCD
information
display
window
X
6
running
procedures.
X Fat measuring function. X
Six speed
direct election
function
X Manual
gradient
adjustment
X
Speed
regulating through
handle and StarUStop
functions
X High
power
and
tone
quality
sound, audio
input function
X Hydraulic
pole
folding attached
with newly set
hydraulic
pole
casing
hook
protection
device
X MultiJayeranti-vibrationdevice X
Over current and overload
protection
device
II.
Product introduction
Electronic
meter
Upright
pole-connecting
pipe
Running
belt
Edge
Rear regulatlng box
Under
frame
\lManual
qradlont
adjustment
Ill. Product
explosion diagram
M
@./
w
il
L.@ P
Yq/
lV. Particular
sheet of explosion diagram
S/N Part name
Qtv.
S/N Part name
Qtv.
Electronic meter I 29 Running frame 1
2 Handle-type hear rate meter
2 30 Bulkhead
(30x15)
2
3
Tear-proof
armrest 2 31 Air
spring casing
1
4
Armrest
bulkhead
2
32
Running
belt lower cover
1
5
Edge
2
33
Treadle housing 1
6 Running
belt
1
34 Anti-loosing clip 1
7
Motor cover 1
35
Air
pressure
bar
I
8 Motor
belt
I
36
Rectangular
40
x
80 inner
bulkhead
2
I
Electronic control board
1
37 54 roller 2
10 Fore drum
1
38
MB
(O16 x
1
.2) small flat washer
24
11
MB
x
'1
00
hexagon
socket
pan
head screws
3 39
Foot
pad
4
12
M6X40 cross countersunk head
screws
6 40
M8
X
50 hexagon socket
pan
head screw
2
13
Running board 1 41 Under frame 1
14
Edge spacer buckle 6 42 Black
gasket
2
15 Fuse base 1 43
M'|2X80 hexagon
socket
Pan
head
screw
2
16
Line
clip
1 44
MBX 16 hexagon socket
pan
head screws
4
17 Switch 1 45
M8
(O24x2.0)
curved small
washer
4
18
M8
x
45 hexagon socket head
cap
screw
1
46
Upright
pole
1
19 Rear drum 1 47 Motor base
(Zhongyang)
1
20
M8
x
75 hexagon
socket
head
cap screw
3 48
M8
x
30
hexagon
socket
pan
head screw
1
21 Right rear regulating
box
1 49
MBX30 hexagon
socket
head
cao screw
4
22 G25 bulkhead 2 50 DC motor
1
23
Anti-vibration
pad
6 51
Upright
pole-connecting pipe
I
24 Left rear regulating
box 1 52
Decorative cover of upright
pole
horizontal oioe
4
25
Manual
gradient
adjustment
,|
53
M5
x
20 big flat head cross
tapDinq screw
4
26
Bulkhead of
gradient
adjustment
nine
2 54
M6
(O18
x
1
.0) curved big
washer
4
27 M8
stop nut 7
55
M8
X
55
hexagon
socket
head
cap screw
4
28 M8x45 flat
head cross screw 2
-4-
-5-
V. Assembly
step
All
parts
of elechic treadmill have
been strictly
assembled
and debugged
before
the
exworks. An
elechic treadmill
can
be easily assembled into
if the installation is
carried out
by observing
following
steps.
Step l: Open the
packing
box, take
out the
treadmill,
insert the left
upright
pole
(there
is
no
connector lug
in the
bottom of the
upright
pole)
into the
under
frame,
and use a
pan
hexagon
socket head
cap screw
(M8x16,
with
curved
washer) for
fixation,
and two
pan
hexagon
socket head
cap screws
(M8 x
55,
with
flat
washer) for
locking. Next,
couple
the
line
of the
right
upright
pole
(there
is
connector lug
in the
bottom of the
upright
pole)
with
the line
of
under
frame,
then
insert
the
under
frame.
Use
a
pan
hexagon
socket
head
cap screw
(M8X
16, with
curved
washer)
for fixation,
and two
pan
hexagon
socket head
cap screws
(M8 x
55,
with
flat washer) for
locking.
Step ll:
Apply
the
decorative cover
of
the
upright
pole
horizontal
pipe
to the
upright
pole
horizontal
pipe.
Then,
use two
pan
hexagon
socket head
cap screws
(M8 X
1 00, with
curved
washer) to fix
the upright
pole
horizontal
pipe.
Step
lV:
unscrew
the screws
(M6x10)
which
fixes the
anti-loosing
clip.
Step lll: Couple the
wire in the
left and right
handles
with the wire
in the meter.
Use four
tapping
screws
(M5X20,
with
curved washer)
to
fix the meter, then
insert the wire
end
into
the
holes of the
long slot of the armrest
pipes.
5.3-Under the
standby state,
press
the
"Mode"
Key to
enter
the Time
countdown Mode and the
Time Window
will display
"'15:00"
and flash.
The
exercise time can be set by
pressing
the
"Speed-up
and Speed-down" Key
and
the
setting range is 5:00-99:00. Press the
'Start"
Key
after the setting is
accomplished, and then
the treadmill
will
start to
run
after 3s. The
speed can be adjusted by
pressing
the
"Speed-up
and Speed-down" Key
or Speed shortcut
Key; Pressing
the
"Stop"
Key will
stop the
treadmill. Time
countdown
will
decrease
progressively
from
set
value
to
zero, when
the countdown
turns
to zero, the treadmill will
slow down steadily to
stop, and enters into standby state after it
completely stops.
S.4-Under the
standby state, continuously
press
the Mode Key twice to
enter the Distance
countdown Mode,
the Distance
Window will
display'1.0" and
flash,
pressing
the'Speed-up" and
"Speed-down"
Key
can set the exercise distance, and
the scope of distance setting
is
0.5-99.9.
Press
the
"Start"
Key
again
after the setting is accomplished,
and
then the treadmill will
start to
run
after 3s.
The
speed
can
be
adjusted by
pressing
the
"Speed-up
and Speed-down"
Key
or Speed shortcut Key.
Pressing the
"Stop"
Key
can stop
the treadmill.
Distance countdown will decrease
progressively
from
set value to
zero, when the
countdown
turns to
zero, the treadmill will slow down steadily to
stop, and
enters into
standby state after it completely stops.
S.S-Under
the standby state, continuously
press
the
Mode Key
three times to enter the Calorie
countdown Mode,
the Calorie
Window will
display
"50'
and
flash,
pressing
the
"Speed-up
and
Speed-down" Key can
set
the
calorie, and the setting range
of
calorie is: 10-999. Press the
"Start"
Key again
after
the
setting is accomplished, and then the treadmill will
start
to run
after
3s.
The speed
can be adjusted
by
pressing
the
"Speed-up
and Speed-down" Key or
Speed shortcut
Key. Pressing
the
"Stop"
Key
can stop the treadmill. Calorie countdown will
decrease
progressively
from set value
to zero, when the
countdown
turns to zero,
the treadmill will slow down steadily to
stop, and enters
into
standby state after it completely stops.
6. Display
scope of the
various values:
Parameter
setting lnitial Setting initial value
Setting
range
Display
range
fime
(minute:
second) 0:00 15:00
5:00-99:00
0:00-99:59
ipeed
(KM/H)
1.0 N/A N/A
1.0-14
)istance
(
KM
)
0 1.0 0.5-99.9 0.00-99.9
leart
beat
(times/min)
P N/A
N/A 50-200
lalorie
(kilocalorie)
0 50 10-999 0-999
7.
Programming Mode
The system is
provided
with
a total of 6 buillin
programs
(P1-P6),
under the standby state,
press
the
"Programming"
Key,
the Distance
Window
will
display
'P1-P6',
the
.TIME'
Window
displays the
preset
time
"10:00"
and flashes while the favorite
program
is selected; Press the
"Speed-up
and Speed-down"
Key
to set the required
exercise time
(setting
time is 5-99 minutes),
then
press
the
"Start"
Key to start the built-in
program.
The
built-in
program
is divided
into
10
sections.
The
operating time in each section=setting
time /10.
When
the
program
enters into next
section, the
system
gives
a sound of
'Bi-Bi-
Bi", and the speed of the
system
will
change along with the
program
section.
Meantime,
the speed can be
changed through
pressing
the
"Speed-up",
"Speed-down"
or
Speed shortcut Key. But when the
program
enters into next
section,
it will return to the
speed of that
section.
When
a
program
is
completed, the system
gives
a sound
of
"Bi-Bl-
Bi". The
keadmill
slows down till to stop and enter to
standby state.
Table for
Built-in Program:
\\ntervar
Program
-\-\
Set time/10
=
The
operating time in
each section
I
2
3
4
5
6 7
8
o
10
P1
Speed
3
3 6
5 5
5 4
4 4
3
P2
Speed
3 3
4
4
5
5 5 6 6
4
P3
Speed
3 3
5 6 7
8 6 4
3
3
P4
Speed
3
6 6
6
7
7
7
3 3
3
P5
Speed
3
8 8
I 8 7 6
3
2
2
P6
Speed
2 5 6
7
7
7 7
7 3 3
8.
Fat measuring
Mode:
Under the
standby state, continuously
press "Programming"
Key to
start
the
detection function
for
physical
indexes
(FAT),
or
press
"Mode"
Key to
enter inlo interfaces F-1,F-2
F-3, F-4
and
F-5
(F-1-gender,
F-2-age,
F- 3-body height,
F-4-body weight
and F-5-
physical
detection). The
parameters
for 01-04
are sei up by
pressing
"Speed-up
(+)'and 'Speed-down
O"
Key
(parameters
are shown in the following table).
After the
sefting, the
"Mode"
Key
is
pressed
to enter
into
F-5
Physical
Examination
lnterface. At this time,
you
should hold handle-type
heart rate metering
plate
with
both
hands.
Your
physical
indexes will
be displayed in 4-5s.
Check whether the
displayed
values
are in accordance with
your
body weight
and height. The
physical
indexes
(FAT)
are used
to
display the relation
between the
body weight and body weight
rather than
body
proportion.
The FAT
is applicable to any male
and female
and can
provide
the weight
adjusting basis for
people
along
with other healthy
indexes. ldeal FAT
should be
in
range
of 20-25.|t means too thin
when the value
is lower than 19, the
overweight when the value
is in range
of 25-29 and the obesity when
the
value exceed 30. said
for reference
and cannot
be used as
F-01
Gender
Male
(01)
Female
(02)
F-O2
Age
10-----99
F-03
Body
height
100----220
F-04 Body weight
20-----150
F-05
Physical
index
<19 Slightly thin
Physical
index
=(20---2s\
ldeal
Physical
index
=(25--29)
Overweight
Physical
index >30
Obesity
medical data.).
9.
Functions
of safety switch:
Under any state, removing the
safety switch can
emergently stop the treadmill. At the
emergency
shutdown
of the treadmill, all
window
displays and the
buzzer
gives
an alarming
sound of
"BB'.
At
this time,
any operation
(excluding
shutdown) cannot be carried
out
for
the treadmill.
After
the
safety lock is
correctly
reinstalled,
the treadmill
enters into the standby
state again and waits for
input command.
-8-
-9-
10.
Sleep function
The system
is
provided
with
power
saving function.
Under the standby
state, if no key
commands
are inputted withln 10 minutes,
then the system will
enter
power
save
mode,
and the
display will
be closed automatically. The
system can be restarted
again by
pressing
any button.
11. Functions of Heart-beat
measurement:
The heart-beat
displav is onlv used
as
the reference
value rather than medical
data. During the
measurement, hold the
heart rate sheet firmly with
both hands, and the whole
procedure
will take
few seconds.
Vll. Use method
and safety
protection
for treadmill
1.
Debugging of
treadmill
1 .1 After the
installation is completed,
position
the
safety switch to the
corresponding
position
of
electronic meter.
't.2
Before the
powering,
inspect whether
the
power ground
wire is well
grounded
and
pull
the
running
belt
with hands
to check whether
it can
run
flexibly without any
abnormal sound.
1.3
Plug in the
power
supply and open the
power
supply lock. Then, all windows
on the
electronic meter show the
initial
values
and the running
belt is still.
1.4 Press the
"Start"
Key and the treadmill
starts operating
at a low speed
(the
operating
speed is km/h).
Observe whether the
treadmill and electronic meter
can operate normally.
'1.5
Press
the
"Speed-up"
Key,
"Speed-down',
"Gradient
ascending" and
"Gradient
descending'
Key
to observe whether
the
regulation
is normal.
1.6
Press the
"Stop"
Key or turn
off
the
safety switch, and the treadmill will
stop operating. Turn
off
the
power
switch
and unplug the
power
supply.
2.
Operating instructions
After
being debugged,
the electric treadmill
can be
put
into use:
2.1 Plug
the
power
supply
in
the
household
220V
outlet.
The
outlet
must
be
orovided
with
appropriate
qroundinq
wire.
2.2 Emplace
the safety lock
and
press
"Start"
Key, and then the running
belt will operate
slowly
(the
speed
is about 1 km/h). The speed
per
hour
is displayed on the meter.
2.3 lf the treadmill needs
to be accelerated,
feet, loosen the
air spring casing, and
press
the
"Speed-up'
Key
and the
then slowly set the
ireaimill level in
buzzer's
"tick"
indicates
one level up.
order, as sirown in the following
figure:
The maximum
speed
per
hour
is
14kmlh^
2.4
lf
you
cannot wait for the
deceleration
while running
on the treadmill
at a
high
speed,
you
can
pull
out the safety
switch and the
treadmill will immediately
stop.
2.4. When
the exercise is
ovel
press
the
"Stop"
Key
after the speed is
slowed down, and
the treadmill will
slowly stop.
2.5 Folding
operation:
During
the folding
operation,
restore
and
stop the
treadmill firstly,
and switch
off the
power
supply. Unplug the
power
supply
in
the front
of treadmill,
please
be sure that the
air spring casing is
firmly
stuck, then remove
or leave the
treadmill. When
the
treadmill
is
placed
down, stamp
the air spring casing with
3. Safety
protection
for
treadmill
3.1.
ln
any emergency, as long
as the exerciser
turns off the safety switch,
the treadmill
will
be
power
off.
Therefore,
when
you
are exercising,
please
be sure to clip the
safety switch on
the appropriate
position
the on
your
clothes to
ensure
the
safety.
3.2.
When the treadmill
belt skids or the running
belt
is
stuck,
the motor will
stop in about 5s.
Vlll. Precautions
1. Circuit
1.1 Avoid
using other electric appliances
in the same
power
supply
circuit.
The
power
supply
circuit
must
be able to supply
over 8.3A electricity current.
1.2 lt
is
required
that the
service
voltage
should be in the
range
ol
220v!10o/o. The voltage
beyond this range
may lead to the abnormal operation.
'1.3
After
being used,
the treadmill should be immediately
unplugged.
1.4
ln Winter,
certain
humidity
should
be
kept indoors
to avoid strong static electricity.
1.5 lf the
power
wire
is damaoed after use.
please qo
to
specified
products
distributor
for
replacement
or
purchase.
2. Placing
environment
2.'1
lt is only
proper
for the treadmill to
be
placed
indoors for
protection
against
humidity. lt is
forbidden
to splash water
on the treadmill. lt is
forbidden
to
place
any
foreign materials
on
or inserted them in the
treadmill.
2.2
During
the
operation of the treadmill, the motor will
generate
a small number of sparks, so
the treadmill should be
placed
at a drafty
place
and
kept
away
from
explosives.
2.3 When
the treadmill is used, ensure its fore
and
rear feet reliably
contact the
ground.
lf
the
ground
surface is uneven,
it should be stably
padded
with carpet
or
rubber
plate.
2.4
Pay
attention to the
interior hygiene
usually
to
reduce
indoor
dust because its sensibility
may be influenced by the dust
adhered on the electronic components.
3. Precautions
before or during exercise
3.1
For
your
safety, wear sports
clothes and select suitable sports shoes when using the
treadmill. lt is strictly forbidden
to exercise on the treadmill with bare feet.
3.2 lt is not allowed for two or more
persons
to
do exercises on the treadmill at the same time.
3.3 Prepare a towel before running
to
prevent
sweat from dropping
on the
running
belt and
being thrown into the enclosure to damage the electric
appliance.
3.4
The
beginner can
get
on the treadmill only
after
he
stands on the edge to test several times
with
one
foot
and
feels
capable of keeping
up
with
the speed of the running belt.
3,5
The
treadmill has enough motor
power.
ln
principle,
the zero start can be realized, but to
extend the
service life of
the treadmill,
it is suggested that
you
should stand on both edges
of the treadmill
and
get
on it for exercise after the normal
start.
3.6 lt
is strictly
forbidden
to
get
on and off from the rear end
as it is very easy for
people
to
tumble
in such
way.
3.7 The strength should be equal when
the
hands
are on the armrests and run on it
straightly
to avoid belt deflection.
3.8
When
people
run
in a normal state, the two hands
should be
moved from
the armrests. The
arms can be swung boldly
so
that the
exercise result
will
be better.
3.9
The
stop lock should be
pressed
when
get
off
the treadmill.
Don't
get
off the treadmitl until
the
running
belt
stops
completely.
3.10 Keep the child away from the running treadmill for fear
that the hand or the clothes may
clamped by
the running
belt to cause serious injury.
3.11
It is
strictly
forbidden
to touch the
working
running
belt by
hands.
4. Additional
precautions
4.1 The cardiac should not use the
electric treadmill alone.
4.2
Determine the
running
speed
according to
your physical
conditions; and the
sick should
not
use the treadmill or use it under the instruction
of a doctor.
4.3 The heart rate
sensor is
not
a medical facility and the detection results
are
for reference
only.
-10-
-11-
lX. Daily servicing
and maintenance
of electric treadmill
During the
daily use of the
treadmill, the following
should
be
noted for
the maintenance.
1. Keep
the treadmill
clean
1.1 The
service life
of
the treadmill
can be significantly
extended by keeping
clean. Often wipe
the running
board
and
footboard
exposed
on the two
sides of the
running
belt.
Reduce
long-term
accumulation
of the dust
and dirt under the running
belt.
'1.2
The running
belt
can be wiped with
soft cloth dipped with
soapsuds.
Don't let the water flow to
the
bottom of the running
belt and
into
the
shield.
'1.3
Regularly
check
each bolt and nut. Please
tighten
and
fix them
immediately with
tools if
they
are
loose.
'1.4
Regularly
check whether
the
groove
of the
motor
belt is
clean. lf there
are
residual,
they
must
be cleaned off to avoid
unnecessary vibration when
it is
used.
1.5 Regularly
clean the
electric control system
and the dust
surrounding the motor to
ensure
normal
operation of the treadmill.
2. Lubrication
2.1
A bottle of
special lubricating
oil
for running
board
is attached. Running
board surface
should be evenly lubricated with
special
lubrication regularly to
avoid the damage
of
running
belt
and
running
board caused
by
the
temperature rise
due to the friction
between them,
and
to
reduce
the load
of the
motor.
(Note:
the child should not
play
with
it in fear
of eating by
mistake)
2.2 After
the
treadmill
has
been used
for a while,
the running
belt and running
board
should be
lubricated with the
special lubricant. The
lubricating time
interval is different
according to the
references
are
shown
are
shown below:
Usaoe time of treadmill
Lubricatinq
time
interval
Less
than 3
hours
usaoe time
per
week
Once for
three
months
3-6 hours
usaqe time
oer
week
Once for one month
More than
6 hours usage time
per
week Once for ten davs
:read
)ricating method:
Loosen
the
right
and left
nill with sneciel t6nlc lift thc n rnnind hall
adjustment
bolts at the
rear
special
tools,
right
and left
adjustment
bolts at the
rear
end
of the
running
belt about
10-15cm,
pour
a
good
amount of
special lubricating
oil on the top surface
of the
running
board, and smear it
evenly and
tighten the running
belt.
(For
adjustment method,
see the
"Adjusting
method for
the tightness
of
running
belt")
The
over lubrication
should be avoided. As
for the lubrication,
it is by no
means
"the
more the
bette/'. Please remember:
reasonable
lubrication is
an important
factor
to extend the service
life of the treadmill!
3. Judgment for friction:
The frictional
force
of
the
running board
and
running
belt
can be increased by
uncleanness or
reduction
of lubricant, which may
damage the motor
and control
panel.
The
excessive frictional
force
is characterized with followings:
3.1 Under the
power
off condition, it is
arduous to drive the
belt by
feet,
or even
the belt
cannot
be driven;
3.2 The treadmill runs
at an intermediate
speed. The running
belt completely stops
as soon
as the safety
switch is turned off;
3.3
The
increment of frictional force
may cause
the damage of motor
or control
panel,
short
circuit, tripping, fuse
burn-out,
etc.
4, Adjustment
for the tightness
of running
belt:
4.1
Although all treadmills
have been adjusted
at exworks, the running
belt may become
loose
after the treadmill is
used
for
some time. The maintenance
is mainly
carried out by the user.
lf
the running
belt is too
loose,
the
skidding
phenomenon
of running
belt and drum will
occur
when
you
step on the running
belt. But
excessive
tightness
is not
good
either
because it may
damage
the
motor, running
belt and drum, increase the running
noise
of
the
treadmill,
etc.
ln
general
condition, it is
better
to
lift
the
two sides
of
running
belt 5-6cm
away
from
the
running
board.
4.2 Judgment method for tightness
of running
belti
Adjust the treadmill
speed to
1.5
km/h,grasp
the armrest forcefully with
both hands and
prevent
the
operating of running belt with feet.
At this time, if-the-runnjng-b€ltstgp€-nrming,
z.
thejtonl^drumcontinues"runnin$
but the running
belt continues
running
after being released,
indicating
that the
running
belt is excessively loose. Meanwhile,
the user
may feel
the
halt
at
sometimes, and the long-term
use under the
loose
state may shorten the
service
life
of
running
belt.
Therefore,
adjustment should be done timely.
4.3 Adjusting method for the tightness
of
running
belt: After the treadmill
is used
for
some
time,
the halt may
be
felt while
you
are running
on
it, which
is caused by the excessive loose
running belt. The tightening
adjustable bolt of the right and
left
rear regulating
box is used
to
ad,ust the tightness
and deflection. lt is the core component
of
the
adjustment of
the
complete treadmill.
Adjusting method
(note:
the clockwise means tightening
and the anticlockwise
means
loosening.
All the
tightening and loosening as shown
below stand
for
clockwise and
anticlockwise
respectively.)
After the treadmill is used for
some
time, the
running belt will
get
extended
slightly.
lf
you
feel
the skidding
running
bet, it shows the
running
belt
is too loose.
Thus, tighten the
adjustable bolts of rear cover at both
sides at
the
same
time
by
1/4
circle
until no skidding or halt
is
felt
while
you
are running on the treadmill.
Special
attention: As
for
the running
belt,
it is not the tighter
the better.
The
tightness should
be adjusted as required. The
service life of
the running
belt may be shortened if it is too tight.
5.
Adjustment for
deflection of
running
belt:
As for
all treadmills, although the
running
belt has been adjusted
at exworks, the
running
belt
may
suffer the deflection after the
treadmill
is
used
for
some time.
This
is attributed to
following
reasons:
5.1
The
treadmill body is
placed
unevenly.
5.2
While
exercising on
the treadmill,
the user fails to run
on
the
central
position
of
the running
belt.
5.3
The
strength of user's feet is uneven.
5.4 Adjustment for deflection: lt only takes a few minutes to recover
artificial deflection by
no-load
operation.
As for
the
non-recoverable
deflection, the
running
belt
adjusting
bolts
should be adjusted
with the
auxiliary special tools by half a
circle.
For
example, if
the
deflection is leftward, clockwise
adjust
the
left adjusting bolts or anticlockwise adjust the
right
adjusting bolts,
and
if
the deflection
is rightward,
clockwise adjust the
right
adjusting
bolts or anticlockwise adjust the
left adjusting bolts.
The
defleclions of running belt are
mainly
maintained and repaired by the
user.
As the
deflection
may
seriously damage
the
running
belt, the deflection should
be timely corrected
if
any.
6.
Adjustment for
motor belt:
6,1 As for
all
treadmills,
although the motor belt has been adjusted at exworks, the running belt
may suffer the halt
after
the
treadmill is used
for
some time, because the motor belt
gets
loose.
6.2
Method for
judging
the tightness
of motor belt: Adjust the headmill
speed
to 1.5 km/h,
grasp
the armrest
forcefully with
both
hands
and
prevent
the operating of
running
belt
with feet. At
this time, if-the"funning-hejt"and-frant-drum-sJop-runoing-simuttaneousjy^
but the running belt
continues running after being released, indicating that the motor
belt is excessively loose.
Meanwhile,
the user may feel
the
halt at
sometimes, and the
long-term
use under the
loose
state may shorten the service life
of
motor
belt.
Therefore,
adjustment should be done
timely.
6.3 Solution: Use special
tools
to clockwise adjust the motor belt adjusting
bolts
for several circles
until the user cannot
feel
the
halt.
This
adjustment
is mainly
carried out the by user.
Adjusting method
for motor belt: Clockwise adjust the motor belt
adjusting bolts by
half
a circle
with
auxiliary
tools.
Special attention: As for the motor
belt, it is
not the tighter the
better.
The tightness
should be
adjusted as required. The service
life of
the running
belt may be shortened if it is too tight.
-12- -13-
Phenomena (abnormal
Po6sible reasons
Examlnation m6thod
Fault
elimination
Pryer fallure
The
electronic
meter does not
1. The
plug
or
droPout
1.
lnspecl whether the
plug
and drop-out
line
ln each section
are
firmly
lnsened.
l. Fimly
insert the
plug
and drop{ul
line.
2.
The
power
switch
is
not 2. Inspect whether the
power
switch
is
tumed on.
2. Restart
the
power
supply.
The motor does
not work.
1. lhe
related line
of
control motor
is out of
order.
1.
lnspect
whether
the line
of @ntrol
moto.
is @rectly
and
lirmly
inserted
1. Re-insert the control
line of the
motor,
2 The
START
KEY
b rct 2. lnspect whether
the key is
out ol order
or without stadlho swilch
2 Press
the START
KEY
agaln to test
3.
t he
sarety
switch
is not
3. lnspect whether the
safety switch is
3, Reset
safety swltch.
4. The
plug
ofthe
motor
is
l@se
or the motor is out
4,
lmplement the
exchange test to
inspect the fault
of
motor
4, Repla@
the motor
5, Ihe
power
supply
or
the specification
of the
control
(AC (l'10/230)
V)
5.
lnspect
and confirm lhe specification.
5, Select correct
specifi€tion ahd
crry out the
test again.
No
speed
response
SENSOR induction
is
bad.
1
lnspect the
distance and th€
position
'l
Adiust the distance within sm/m.
2lnsrect whether
the
wire rod
ls short
Replace the wire rod
or SENSOR.
3 lnspect whether
the connectors
oI
the
wire rod are flrmlv connecled
3. Rensert the connectors
of the wiae
Shokes are
imperf@t
and the
shadow exists.
The screre
of PA carcuit boards are not tightened up or the
Connector is
in.dredlv hh.ad
Dismount
the
shell
and
press
PA
circuil
board to check
short circuit or failing.
Replace the connector
and tighten up
the screws.
1 SENSOR induclion is
1. lnspec{ whether
the wire rod is short
circuit or falls off, 1 . Re-inshll the wie rrl
Do not dlsplay the
heart beat.
bad.
2
lnspect whether the
connectoE are
n6.dv .6nnp.Jcd
2. Reinsefr the wire rod.
2 The body induclion
ls 3 Both hands
are sljghtly wet or
rub
-^ai6.r
6-^h
^rha.
3 Cary out the measurement aoaln.
E01
1.
The motor
€n
opeGte atter being started. The motor
Slgnal @nnot be
detected for
@ntinuous
4s, and the treadmill
1.
lnspect whether lhe
photoelectric
sensor and the wire rod
is open chcuit or 1. Replace the
photoelectric
sensor
rnd raJnc.d tha .^hhart^6
2.
lnspecl
whether
the
connectors
are
correctly
inserted, and lhe magnetlc
<cn.^r i< hr k6n
^.
d,m.daa
2. Replace
the
photoelectric
sensor,
The
molor does not rcrk
after being
started, and
displays E01 ln 4s.
3.
lnspect whether moto. belt
is out of
3. lnstall
the
belt.
4
lf
no foresaid
phenomena
occur, the
electrcnic control mav be brokcn 4 Rcnlecc ihe alpdronl. ..ontr6l
EO2
1. lnspecl whether
it exceeds the rated 1.
Replace the motor
orihe control
and cafl out lhe test aoain
2. lnspecl whether
there is lhe
over
currenl
noise or chared
odor at the
ooehtion ofthe motor
2. Replace the
motor
3,
lnspect Mether there
ls a chaffed
odor at
the control.
3. ReDlace the
control.
4.
lnspect
whether
ihe
power
voltage
sDecification does not confirm or l@ low.
4
Carry out the test
again
by
using
correct volboe sDecif imtion
E03
Explosion-proof orotection
1.
lnspect
whether the
power
vottage is l.
Carry out the test
again
by
using
2. lnspect
r
@nnected.
r the motor
ls @rectly 2. Reconnecl the
motor interfa@ to
3. lnspect whethsr there
is
an abnormal
6d6r in rhc .^ntr61
3,
Roplace
the
@ntrol.
E06
Runnlng
@rent of the
motor b l@ lM.
1. lnspect whether
lh€
motor
lano
1 . Connecl the trEtor line teminals limlu
2 Runnim drent of the mtor is lm lM
E08
24Cr2 ts bfoken d not
!.Reda@ d 6Mlv in*d lhe24CO2
E10
lnstant
peak
current
oflhe
molor is
abnormal.
'1.
hspect whether the toreion
of the
drlver is nomal,
and the mtor is short
ci@it or strf,-k
X. Elimination
methods
for common faults:
Xl. Precautions for exercise
Warm-up:
Before each exercise, it is necessary to take
5-'10
min
to do the
warming
up, including
the
warm-up
(including
the
stepping
machine, treadmill, rowing machine
and exercise bike)
and stretching
(stretch
the muscles in the training
part
and bend the
joints)
to
prevent
the
sport injury.
Breath: During the exercise, it is not
allowed
to hold the
breath. Generally, inhale
from noise
when
doing the
preparing
or homing
actions and exhale
from mouth when
putting
forth the
strength.
The
breath should be coordinating
with
the actions. ln
case of short breath, stop
exercising
immediately.
Frequency:
The
training
for
the same
muscle
should be carried out at the interval of
48h,
that is
to say, the training for the
same
muscle
should be carried out every other day.
Load: Everyone should determine the training
intensity according
to
his or her
physical
conditions.
The
load exercise should be done
progressively.
ln the initial exercise,
you
may
get
muscular ache. As
only as
you
keep
exercising in the aforesaid
frequency,
the ache
will
be
relleved.
Relax: After
each exercise,
you
should do s-minute homing actions, especially the stretchlng and
relaxing for muscles
of
trained
legs to
prevent
the muscle
from
getting
long{erm spasm
and maintain
the
elasticity of muscle.
Diet:
ln order to
protect
the
digestive system,
the
exercise can be carried out t hour after the
meal
and
have meals
at least
half
an hour after
the exercise.
During
the exercise, drink
water
as
little
as
possible.
lt
is
forbidden
to swallow
much water for fear
of burdening the
heart
and
kidney.
-t4-
-
l5
-