8 HDC2450 Motor Controller Datasheet Version 1.2. July 20, 2010
Power Stage Electrical Specifications (at 25oC ambient)
TABLE 7.
Parameter Measure point Models Min Typ Max Units
Battery Leads Voltage Ground to VBat All 0 (1) 50 Volts
Motor Leads Voltage Ground to M1+, M1-,
M2+, M2-
All 0 (1) 50 (2) Volts
Power Control Voltage Ground to Power Control
wire
All 0 (1) 65 Volts
Minimum Operating Voltage VBat or Pwr Ctrl wires All 9 (3) Volts
Over Voltage protection
range
Ground to VBat All 5 50 (4) 55 Volts
Under Voltage protection
range
Ground to VBat All 0 5 (4) 55 Volts
Idle Current Consumption VBat or Pwr Ctrl wires All 50 100 (5) 150 mA
ON Resistance (Excluding
wire resistance)
VBat to M+, plus M- to
Ground at 100% power.
Per channel
HDC2450 3 mOhm
HDC2450S 1,5 mOhm
Max Current per channel for
30s
Ch1 or Ch2 Motor current HDC2450 150 Amps
HDC2450S 300 (6) Amps
Continuous Max Current per
channel
Ch1 or Ch2 Motor current HDC2450 80 (7) Amps
HDC2450S 160 (6)(7) Amps
Current Limit range Ch1 or Ch2 Motor current HDC2450 10 100 (8) 150 Amps
HDC2450S 10 200 (8) 300 (6) Amps
Stall Detection Amps range Ch1 or Ch2 Motor current HDC2450 10 100 (8) 150 Amps
HDC2450S 10 200 (8) 300 (6) Amps
Stall Detection timeout
range
Ch1 or Ch2 Motor current All 1 65000 (9) 65000 millisec-
onds
Short Circuit Detection
threshold (10)
Between Motor wires or
Between Motor wire and
Ground
HDC2450 550 (11) 1600 (11) Amps
HDC2450S 1100 3000 (6) Amps
Short Circuit Detection
threshold
Between Motor wires and
VBat
All No Protection. Permanent damage will result
Motor Acceleration/Deceleration range
Ch1 or Ch2 All 100 500 (12) 65000 millisec-
onds
Note 1: Negative voltage will cause a large surge current. Protection fuse needed if battery polarity inversion is possible
Note 2: Maximum regeneration voltage in normal operation. Never inject a DC voltage from a battery or other fixed source
Note 3: Minimum voltage must be present on VBat or Power Control wire
Note 4: Factory default value. Adjustable in 0.1V increments
Note 5: Current consumption is lower when higher voltage is applied to the controller’s VBat or PwrCtrl wires
Note 6: Current is sum of both synchronized channels. Current must be balanced between channel to obtain max current.
Note 7: Estimate. Limited by case temperature. Current may be higher with better cooling
Note 8: Factory default value. Adjustable in 0.1A increments
Note 9: Factory default value. Time in ms that Stall current must be exceeded for detection
Note 10: Controller will stop until restarted in case of short circuit detection
Note 11: Sensitivity selectable by software
Note 12: Factory default value. Time in ms for power to go from 0 to 100%