ROBOT3T THC3T-02 Operation Manual

Operation manual – THC3T-02 with Step/Dir
1
Notes on safety:
Improper use or disregard of these warnings may result in the injury or death of people.
becomes necessary please consult a qualified mechanic.
Do not operate this product with wet hands, wet gloves, or any wet clothing. Provide adequate protection for all risks associated with plasma cutting. Before turning the unit on, secure the safety of others, and read and
understand all instructions. If you have any questions or concerns, do not continue.
After assembly, secure protection of contact terminals from operator's touch.
Here are the addresses where you can get help if you encounter problems:
E-mail: sales@robot3t.com Website : www.robot3t.com
Thank you for purchasing ROBOT3T product.
Please read this manual carefully and keep it for future reference.
Operation manual – THC3T-02 with Step/Dir
2
Fig1. Block diagram
Output
Pulse/Dir
1. Device information
1.1 Introduction
Compact THC3T-02 with Step/Dir output uses arc voltage to maintain a consistent
distance from the plate while the torch is cutting. This allows the system to maintain proper
torch height regardless of variations in the material, of flatness of the cutting bed.
Simplified block diagram:
The THC3T-02 package includes:
1 main board; 1 divider board; 1 potentiometer + cable.
1.2 Specifications
- Using potentiometer to set height’s torch;
- Voltage divider and noise to obtain the raw signal from the plasma cutting;
- Using signal processing algorithms to derive the voltage stability of the plasma;
- Apply a algorithm to support smooth motion, this is a advantage of Compact
THC3T-02;
- Auto calib the arc voltage with any plasma cutter;
- Auto detect ARC OK;
- Integrated voltage divider 1:50;
- Control directly the Z axes driver with Step/Dir signal, give high
performance and more accuracy.
Operation manual – THC3T-02 with Step/Dir
3
Fig2. Connection diagram
Operation manual – THC3T-02 with Step/Dir
4
Parameter name
Acceptable
Supply voltage
24 -> 36V DC
Maximum arc-voltage
660VDC
Maximum input voltage of 1:50 divider
+6.6VDC
Maximum current of output relays
150mA/100VDC
Weight
300g
External Dimensions (L * W * H)
95x110x45[mm]
Table1. Main parameter
Up, Down: To change the display or data in each mode.
LEDs Status:
Power red LED; Run yellow LED (THC ready); Height
LED1 display “Up”, “Down”, “Height” status of Z-axis;
Fig3. Main board
1.3 Main board
­green LED (Torch height OK);
-
- LED2 is arc-voltage value from plasma cutter.
Buttons:
- Menu: To change mode
-
The main parameters of the master board:
LED
1
LED2
Operation manual – THC3T-02 with Step/Dir
5
DIVIDER
SW 1
SW 2
Discription
100:1
ON
ON
Voltage divide ratio 1:100
50:1
OFF
ON
Voltage divide ratio 1:50
ON
OFF
EXT-
50:1
OFF
OFF
Voltage input of 1:50 divider EXT(extension)
No
Mode
Value
Description
1
U
Set-height
U10 to U300
To set height from torch to material in auto mode by potentiometer.
Fig4. DIVIDER board
1.4 Divider board
SW MODE
2 Setup parameters
Press “menu button to choice mode need to set:
Operation manual – THC3T-02 with Step/Dir
6
2
A
Area for control
A001 to A050
Device will change to auto mode when the arc voltage from: [Voltage Set - Area for control] to [Voltage Set + Area for control]
3
S
Sensitive
S100 to S800
This parameter determines the value respond of Z axis motion.
4
P
Arc-voltage
P000 to P300
Display the arc voltage value from plasma cutter.
No
Function
Value
Description
1
Add paramer d on
the display menu
Delay time
d001 to d099
The delay time to send ARC_OK from
0.1 to 10s: THC will sent ARC_OK signal after this delay, the main purpose is Z axis not move down at the first time of cutting.
2
Add paramer s on
the display menu
Run speed
s001 to s099
Change speed of motor from 0 to 100% of max speed. This parameter only affect in STEP/DIR version.
3
Add state of
Switch SW1
ON and OFF
Change the direction of Z motor.
Table2. Parameters on LED display
Addition of the new version (From 01/06/2017)
Operation manual – THC3T-02 with Step/Dir
7
Fig5. Power Supply
24-36V DC
GND
3 Signals summary of THC3T-02
3.1 Power supply
3.2 Arc-voltage
When connecting directly, use the shortest possible cables for connecting the plasma cutter with THC controller - it is recommended the THC controller to be mounted directly at the plasma cutter.
Operation manual – THC3T-02 with Step/Dir
8
Fig 6. Connect Arc-voltage from DIVIDER board
Operation manual – THC3T-02 with Step/Dir
9
Fig 7: Connecting the plasma source with DIVIDER
While being a universal THC, accepting full raw arc voltage for most any plasma cutter on the market, an exciting new standard feature of this unit is the addition of a 1:50 divider for an extremely fast, simple installation on most major brands. There will most likely be a direct connection for this on the outside of the plasma cutter's unit. Please refer to your plasma cutter owner's manual.
An example of how to connect the THC controller's measurement input with the output of the very popular Hypertherm Powermax45® - The THC comes
Operation manual – THC3T-02 with Step/Dir
10
Fig9. Connect potentiometer
Fig 8. Plasma cutter with voltage divider 1:50 output
standard equipped with a low voltage output of 1:50 divider. This ratio is the most commonly used division in most major brands and there will most likely be a plug for this connection on the outside of the cutter's unit.
3.3 Potentiometer
To set height from torch to material by potentiometer. (U mode on LEDs display)
Operation manual – THC3T-02 with Step/Dir
11
Fig10. Step/dir from breakout board
DIR_Z
shield
STEP_Z
+5VDC
BREAKOUT
EXT_COM
ARC_OK
INPUT
GND
Fig11. Arc_Ok output
3.4 Input Step/Dir (opto)
3.5 Output ACR_OK (OPTO)
If the device operated at auto mode, ARC_OK signal is activated.
BREAKOUT BOARD
BOARD
Operation manual – THC3T-02 with Step/Dir
12
Fig12. Output Step/Dir to driver Z
DIR-
DIR+
STEP
-
STEP+ shield
Fig13. Power Supply
24-36V DC
GND
3.6 Output Step/Dir to Driver-Z
4. Fast connect
Step 1: Turn off plasma cutter. Step 2: Connect power supply.
DRIVER Z-AXIS
- After switching power on, red LED is turn on, the THC controller's display
shows "thc" message, a flashing voltage value is presented for 2 seconds and then run yellow LED blink Turn off THC power and go to Step 3.
- In case of, power LED, run LED or LED 4 digit 7 segment display not turn on
Error.1-page.16
Operation manual – THC3T-02 with Step/Dir
13
BREAKOUT BOARD
DIR_Z
STEP_Z
+5VDC
Dir-
Dir+
Step-
Step+
BOARD
EXT_COM
ARC_OK
INPUT
GND
Fig16. Arc_Ok output
Step 3: Connect input pulse/dir from breakout board.
Step 4: Connect output pulse/dir to driver Z
Driver-Z
Fig14. Connect with
breakout board
Fig15. Connect with
driver-Z
- Turn on THC3T-01 and wait yellow LED blink Jog up/down on MACH3
software to control Z-axis OK Turn off THC3T-02 and go to Step5;
- In case of Z-axis can’t goes up/down  Error.2-page.16
Step 5: Arc_Ok output.
BREAKOUT
Operation manual – THC3T-02 with Step/Dir
14
Fig17. ARC-voltage parameter
Fig18. Voltage set-point parameter
Step 6: Connect Arc-voltage (page.8&9)
- Turn on THC3T-02 and wait yellow LED blink. Press “menu” button 4-times
to select “Pmode (fig.17-page.14).
- Turn on plasma cutter and read arc-voltage area on LED display (example:
Arc-voltage area from 110 to 120) Turn off plasma cutter and go to step
7.
- In case of, THC don’t have arc-voltage  Error.3-page.16
 Step 7: Press “menu” button to select “U” mode and using potentiometer to set “set-
height” parameter value (fig.18-page.14)
- Example: If arc-voltage area on “P” mode from 145 to 155 then:
Set-height = (145+155)/2=150.
Step 8: Press “menu” button to select “A” mode (fig.19-page.15). This parameter
value set about 30. Device will change to auto mode when:
[Set-height – Area for control] < Arc_voltage < [Set-height + Area for control]
Example: U” mode: Set-height = 150;
A” mode: Area for control = 30.
Operation manual – THC3T-02 with Step/Dir
15
Arc_voltage = Set-height
Height green LED turn on
Arc_voltage > Set-height
Z-axis goes down
Arc_voltage < Set-height
Z-axis goes up
Fig19. Area for control parameter
Fig20. Area for control parameter
Device will change to auto mode and turn on relay ARC_OK when:
120 < Arc_volatge < 180.
Step 9: Press “menu” button to select work-screen (fig.20-page.15) and turn
on plasma cutter to using.
All parameters updated online during operation.
Operation manual – THC3T-02 with Step/Dir
16
No.
Code
Name
Causes
Countermeasures
1
Error.1
Power fault
-The THC is broken;
-The power is not connected;
-The line of power supply is broken;
-Replace the THC;
-Connect the power supply;
-Check that the power line are wired correctly;
-Replace the power cable
2
Error.2
Step/dir fault
-The power of breakout board and drive Z are not connected;
-The line of step/dir from breakout board to THC is broken or not connected;
-The line of step/dir from THC to drive is broken or not connected;
-Configuration on MACH3 is not corrected;
-The breakout board or drive-Z are broken;
-The THC is broken;
-Check that the power line are wired correctly;
-Check that the step/dir line are wired correctly or replace;
-Check that the step/dir line are wired correctly or replace;
-Check that configuration on MACH3;
-Replace breakout board or drive-Z;
-Replace the THC.
3
Error.3
Arc-voltage fault
-The power of plasma cutter is not connected;
-The line of arc-voltage from divider board to THC is broken or not connected;
- The THC is broken;
-Connect the power supply;
-Check that the step/dir line are wired correctly or replace;
-Replace the THC.
5. Fault processing