Robinhood RWE3CH9SS Installation Manual

Description: ROBINHOOD WALL CANOPY
B
Model Numbers: RWE3CH6SS, RWE3CH9SS
RW
Issue:
Model pictured: RWE3CH9SS
All dimensions in mm Model may vary slightly from images pictured
1
2
Overview
Pre-installation
Thank you for purchasing a quality Robinhood rangehood. Robinhood has a high standard of quality control and every rangehood is tested and approved before it leaves the factory.
Important:
o Please read the entire instructions before installing the rangehood. o Always switch power off prior to installation. o Stainless steel is very easily damaged during installation if abraded or knocked by tools. Protect the
rangehood with the cardboard box or plastic bag during installation.
o All electrical work must be done in accordance with local and national electrical codes as applicable. o For safety, this product must be earthed. o A power outlet should be within 1500mm of the power cord exit from the rangehood. o The power socket must be accessible and enable the end user to isolate the rangehood from the power for
the purpose of internal cleaning or maintenance.
o 150mm round ducting adapter is supplied. All other ducting accessories are not supplied. All ducting must
comply with local requirements and building codes.
o If re-circulating, ensure that the side outlet grilles are not obstructed. Even a partial obstruction will
restrict the efficiency of the rangehood.
o See Ducting options next page.
Contents of packaging:
1 x rangehood 1 x 150mm ducting adaptor 1 x packet of fasteners and wall plugs 2 x chimney pieces (upper and lower) 2 x chimney bracket 1 x mounting bracket
Typical equipment required:
o electric drill o screwdriver o tape measure o spirit level o duct tape (if ducting) o jig saw (if ducting) o ladder (if ducting)
Pre-Installation - continued
Ducting Options
The method of ducting should be carefully considered before installing the rangehood. The guide below recommends the ducting components to use for all common ducting configurations - through the top of the home (for the roof and soffit) and through the rear of the home. 150mm round ducting should be used in conjunction with this model rangehood. Alternatively this rangehood can be operated in recirculation mode (see Recirculation mode pg 6).
The highlighted area in the table below gives the recommended Uniduct item numbers for different mounting and outlet options.
Duct mounting option
150mm
diameter round outlet
Rear
1688 1634 and
Top (roof)
Uniduct item numbers
1635
Top (soffit/eave)
1634 and
1688
Extra lengths and/or bends may be required, depending on the length required and whether there is any structural material in the run e.g. rafters.
Please note that this chart is designed as a guide. Please consult Robinhood customer services if unsure. For NZ phone 0800 760 667 or www.robinhood.co.nz. For AUS phone 1800 648 556 or www.robinhood.com.au.
3
4
Pre-Installation - continued
Installation position
A Vertical height from bottom of Rangehood to Fixing Plate mounting screws
302mm.
B Set height from the hob surface to the underside face of the rangehood at 750mm for electric hob or gas
hob.
Please check that the length of your chimney assembly will reach your ceiling before securing the rangehood to the wall.
Be advised that the chimney height is such that the optimum height for installation is 750mm above the hob. Should you wish to have the unit lower, or you have a ceiling higher than the typical 2.4 meter (8 foot), then please choose the desired chimney extension kit from page 8.
Minimum height from the hob surface to the underside face of the rangehood
600mm electric hob - chimney extension kit required, see page 8 650mm gas hob – chimney extension kit required, see page 8
Notes: If the instructions for the gas hob specify a greater distance, this has to be taken into account. Any installation above 750mm will compromise the performance.
C Distance between mounting screw holes on Fixing Plate
115mm.
+
+
+