Robinhood RWA3CF9SS, RWA3CF12SS, RWB3CF9SS, RWB3CF12SS Installation Manual

Description: ROBINHOOD WALL CANOPY Model Numbers: RWA3CF9SS, RWA3CF12SS
RWB3CF9SS, RWB3CF12SS
RWB3CF9SS
RWA/B
Issue:H
All dimensions in mm
Models may vary slightly from images pictured
2
Overview
Pre-Installation
Thank you for purchasing a quality Robinhood rangehood. Robinhood has a high standard of quality control and every rangehood is tested and approved before it leaves the factory.
Important:
Please read the entire instructions before installing the rangehood, always switch power off prior to installation. All electrical work must be done by a registered electrician in accordance with local and national electrical codes as
applicable. For your safety, this product must be earthed. The power socket must be accessible and enable the end user to isolate the rangehood from the power for the purpose of
internal cleaning or maintenance. A power outlet should be within 1500mm of the power cord exit from the rangehood. The fluorescent tubes are designed so that if one tube fails (has come loose in transit or has an electrical fault) then the
other tube will stop working until the fault is fixed. This is a fail safe mode. The fluorescent tube(s) may have come loose during transit. To refit a tube refer to page 8, Cleaning and Maintenance,
of these instructions.
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
Young children should be supervised to ensure that they do not play with the appliance. There shall be adequate ventilation of the room when the rangehood is used at the same time as appliances burning gas
or other fuels. There is a fire risk if cleaning is not carried out in accordance with the instructions. You must read the details concerning
the method and frequency of cleaning. Do not flambé under the rangehood. Exhaust air must not be discharged into an existing flue which is used for exhausting fumes from appliances burning gas
or other fuels. The minimum distance between the hob surface and the lowest part of the rangehood is 600mm. This distance shall be at
least 650mm, if the rangehood is installed over a gas hob. If the instructions for the gas hob specify a greater distance, this has to be taken into account.
Attention should be given to ensure that any applicable regulations concerning the discharge of exhaust air is fulfilled. If
re-circulating, ensure that the side outlet grilles on the upper chimney are not obstructed. Even a partial obstruction will restrict the efficiency of the rangehood.
Stainless steel is very easily damaged during installation if abraded or knocked by tools. Protect the rangehood with the
cardboard box or plastic bag during installation. Check the contents of the packaging, check all electrical functions of the canopy before installation. Canopy is heavy. Please ensure adequate care when installing to prevent personal injury.
RWB3CF9SS
RWA3CF9SS
3
Pre-Installation - continued
Contents of packaging:
o 1 x rangehood o 1 x packet of fasteners and wall plugs o 2 x chimney pieces (upper and lower) o 2 x chimney brackets o 1 x Installation and Operating Instructions
Typical equipment required:
o electric drill and screwdriver o tape measure and spirit level o step ladder o duct tape (if ducting) o jig saw (if ducting) o ladder (if ducting)
Ducting Options
The method of ducting should be carefully considered before installing the rangehood. The guide below recommends the ducting components to use for all common ducting configurations - through the top of the home (for the roof and soffit) and through the rear of the home. 150mm round ducting should be used in conjunction with this model rangehood. Alternatively this rangehood can be operated in recirculation mode (Pg.6 Recirculation mode).
The highlighted area in the table below gives the recommended Uniduct item numbers for different mounting and outlet options.
Duct mounting option
Rear
Top (roof)
Top (soffit/eave)
Uniduct item numbers
150mm
diameter round outlet
1688
1634 and
1635
1634 and
1688
Extra lengths and/or bends may be required, depending on the length required and whether there is any structural material in the way, e.g. rafters.
Please note that this chart is designed as a guide. Please consult Robinhood customer services if unsure. For NZ phone 0800 760 667 or www.robinhood.co.nz. For AUS phone 1800 648 556 or www.robinhood.com.au.
4
Pre-Installation - continued
Installation position
A Minimum height from the hob surface to the underside face of the rangehood
600mm electric hob 650mm gas hob
Notes: If the instructions for the gas hob specify a greater distance, this has to be taken into account.
Any installation above 750mm will compromise performance.
B Vertical height from bottom of rangehood to mounting screws
272mm for RWA3CF9SS, RWA3CF12SS 313mm for RWB3CF9SS, RWB3CF12SS
C Distance between 2 mounting screw holes in the back plate of the rangehood
230mm for all models: RWA3CF9SS, RWA3CF12SS, RWB3CF9SS, RWB3CF12SS
+
+
B
A
C
Loading...