1. Safety instructions ......................................................................................................... 3
2. Operating determination ................................................................................................ 4
3. Fixture exterior view ...................................................................................................... 5
4. Installation....................................................................................................................... 6
4.1 Connection to the mains ............................................................................................ 6
4.2 Eggcrate installation ................................................................................................... 6
4.3 Rigging the xture ...................................................................................................... 7
4.4 DMX-512 connection .................................................................................................. 9
4.5 Ethernet connection ................................................................................................. 10
4.6 Wireless DMX operation .......................................................................................... 12
7.1 Tab " Address" .......................................................................................................... 19
7.2 Tab "Information" ...................................................................................................... 20
7.3 Tab "Personality" ......................................................................................................21
7.4 Tab "Manual Control" ................................................................................................ 23
7.5 Tab "Stand-alone" .................................................................................................... 23
7.6 Tab "Service" ............................................................................................................ 24
11.1 Removing the optical module ................................................................................. 32
11.2 Disposing of the product ......................................................................................... 33
Robin Spiider
3
CAUTION!
Keep this device away from rain and moisture!
Unplug mains lead before opening the housing!
FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY
BEFORE YOU INITIAL START - UP!
1. Safety instructions
Every person involved with installation and maintenance of this device have to:
- be qualied
- follow the instructions of this manual
CAUTION!
Be careful with your operations.
With a high voltage you can suer
a dangerous electric shock when touching the wires!
This device has left our premises in absolutely perfect condition. In order to maintain this condition and to en­sure a safe operation, it is absolutely necessary for the user to follow the safety instructions and warning notes written in this manual.
Important
The manufacturer will not accept liability for any resulting damages caused by the non-observance of this manual or any unauthorized modication to the device.
Please consider that damages caused by manual modications to the device are not subject to warranty.
Handle the power cord and all connections with the mains with particular caution!
Make sure that the available voltage is not higher than stated on the rear panel.
WARNING! This unit does not contain an ON/OFF switch. Always disconnect power input cable to completely remove power from unit when not in use or before cleaning or servicing the unit.
Make sure that the power-cord is never crimped or damaged by sharp edges. Check the device and the pow-
er-cord from time to time.
Always disconnect from the mains, when the device is not in use or before cleaning it. Only handle the pow­er-cord by the plug. Never pull out the plug by tugging the power cord.
This device falls under protection class I. Therefore it is essential to connect the yellow/green conductor to earth.
The electric connection, repairs and servicing must be carried out by a qualied employee.
Do not connect this device to a dimmer pack.
During the initial start-up some smoke or smell may arise. This is a normal process and does not necessarily
mean that the device is defective.
Do not touch the device’s housing bare hands during its operation (housing becomes hot)! For replacement use fuses of same type and rating only.
Warning! Risk Group 2 LED product according to EN 62471.
LED light emission. Risk of eye injury. Do not look into the beam at short distance of
the of the product. Do not view the light output with optical instruments or any device
that may conncentrate the beam.
The light source contains blue LEDs.
4
2. Operating determination
This device is a moving head for creating decorative e󰀨ects and was designed for indoor use only.
This device is for professional use only. It is not for household use.
If the device has been exposed to drastic temperature uctuation (e.g. after transportation), do not switch it on immediately. The arising condensation water might damage your device. Leave the device switched o󰀨 until it has reached room temperature.
Do not shake the device. Avoid brute force when installing or operating the device.
Never lift the xture by holding it at the projector head, as the mechanics may be damaged. Always hold the xture at the transport handles.
When choosing the installation spot, please make sure that the device is not exposed to extreme heat, moisture or dust. There should not be any cables lying around. You endanger your own and the safety of others!
Make sure that the area below the installation place is blocked when rigging, derigging or servicing the xture.
Always secure the xture with an appropriate safety wire.
Only operate the xture after having checked that the housing is rmly closed and all screws are tightly fastened.
The maximum ambient temperature 45°C must never be exceeded.
To avoid damage of an internal optical system of the xture, never let the sunlight (or
other light source) lights directly to the lens array, even when the xture is not working
!
Operate the device only after having familiarized with its functions. Do not permit operation by persons not qualied for operating the device. Most damages are the result of unprofessional operation!
Please use the original packaging if the device is to be transported.
Please consider that unauthorized modications on the device are forbidden due to safety reasons!
If this device will be operated in any way di󰀨erent to the one described in this manual, the product may su󰀨er damages and the guarantee becomes void. Furthermore, any other operation may lead to dangers like short-cir­cuit, burns, electric shock, burns etc.
Always push the zoom module into the head before inserting the xture into the ight
case.
5
3. Fixture exterior view
The head should be locked for transportation - the tilt lock latch (7) has to be in the locked position. To unlock the head, move this latch to unlock position before operating the xture.
The ENTER/DISPLAY ON button also serves for switching the display on when the xture is disconnected
from the mains.
1 - Lens array 2 - Yoke 3 - Handle 4 - QVGA touch screen 5 - Control buttons 6 - USB port 7 - Tilt lock 8 - 3-pin DMX OUT 9 - Ethernet IN 10 - Base 11 - Ethernet OUT 12- 3-pin DMX IN 13- 5-pin DMX IN 14- Mains IN 15- Fuse holder 16- 5-pin DMX OUT 17- Moving head
6
4. Installation
Fixtures must be installed by a qualied electrician in accordance with all
national and local electrical and construction codes and regulations.
4.1 Connection to the mains
For protection from electric shock, the xture must be earthed!
The Robin Spiider is equipped with auto-switching power supply that automatically adjusts to any 50-60Hz AC power source from 100-240 Volts.
If you install a cord cap on the power cable to allow connection to power outlets, install a grounding-type (earthed) plug, following the plug manufacturer’s instructions. The cores in the power cable are coloured according to the following table.
Core (EU) Core (US) Connection Plug Terminal Marking
Brown Black Live L
Light blue White Neutral N
Yellow/Green Green Earth
This device falls under class one and must be earthed (grounded)! To apply power, rst check that the head pan and tilt locks are released. Wiring and connection work must be carried out by qualied sta󰀨!
4.2 Eggcrate installation
Disconnect the xture from mains before eggcrate installation
Screw the eggcrate (1) to the head (3) by means of the three screws (2).
7
4.3 Rigging the xture
A structure intended for installation of the xture (s) must safely hold weight of the xture(s) placed on it. The structure has to be certicated to the purpose.
The xture (xtures) must be installed in accordance with national and local electrical and construction codes and regulations.
For overhead installation, the xture must be always secured with a safety wire that
can bear at least 10 times the weight of the xture.
When rigging, derigging or servicing the xture staying in the area below the installation place, on bridges, under high working places and other endangered areas is forbidden.
The operator has to make sure that safety-relating and machine-technical installations are approved by an expert before taking into operation for the rst time and after changes before taking into operation another time.
The operator has to make sure that safety-relating and machine-technical installations are approved by a skilled
person once a year.
Allow the xture to cool for ten minutes before handling.
The xture should be installed outside areas where persons may walk by or be seated.
IMPORTANT! OVERHEAD RIGGING REQUIRES EXTENSIVE EXPERIENCE, including calculating working load limits, installation material being used, and periodic safety inspection of all installation material and the projector. If you lack these qualications, do not attempt the installation yourself, but use a help of professional
companies.
CAUTION: Fixtures may cause severe injuries when crashing down! If you have doubts concerning the safety of a possible installation, do not install the xture!
The xture has to be installed out of the reach of public.
The xture must never be xed swinging freely in the room.
Danger of re ! When installing the device, make sure there is no highly inammable material (decoration articles, etc.) in a distance of min. 0.5 m.
CAUTION!
Use 2 appropriate clamps to rig the xture on the truss.
Follow the instructions mentioned at the bottom of the base.
Make sure that the device is xed properly! Ensure that the
structure (truss) to which you are attaching the xtures is secure.
The xture can be placed directly on the stage oor or rigged in any orientation on a truss without altering its
operation characte ristics .
For securing the xture to the truss, install a safety wire which can hold at least 10 times the weight of the xture.
Use only the safety wire with a snap hook with screw lock gate.
.
.
8
Truss installation
1. Bolt the clamp (3) to the omega holder (5) with M12 bolt and lock nut through the hole in the holder.
2. Fasten the omega holders to the bottom of the base by inserting both quick-lock fasteners (2) into
the holes of the base and tighten fully clockwise.
3. Clamp the xture on a truss (6) and tighten the rigging clamps.
4. Pull the safety wire (4) through the attachment point (1) and through the handle (7) and around the truss (6)
and lock the snap hook with screw lock gate. Use only a safety wire with a snap hook with screw lock gate.
When installing xtures side-by-side,
avoid illuminating one xture with another!
DANGER TO LIFE!
Before taking into operation for the rst time,the installation has to be approved by
an expert!
9
4.4 DMX-512 connection
The xture is equipped with both 3-pin and 5-pin XLR sockets for DMX input and output.The sockets are wired
in parallel.
Only use a shielded twisted-pair cable designed for RS-485 and 3-pin or 5-pin XLR-plugs and connectors in order to connect the controller with the xture or one xture with another.
DMX - output DMX-input
XLR mounting-sockets (rear view): XLR mounting-plugs (rear view):
If you are using the standard DMX controllers, you can connect the DMX output of the controller directly with the DMX input of the rst xture in the DMX-chain. If you wish to connect DMX-controllers with other XLR-out­puts, you need to use adapter-cables.
Building a serial DMX-chain:
Connect the DMX-output of the rst xture in the DMX-chain with the DMX-input of the next xture. Always connect one output with the input of the next xture until all xtures are connected. Up to 32 xtures can be connected.
Caution: At the last xture, the DMX-cable has to be terminated with a terminator. Solder a 120 Ω resistor between Signal (–) and Signal (+) into a 3-pin (5-pin) XLR-plug and plug it in the DMX output of the last xture.
1 - Shield 2 - Signal (-) 3 - Signal (+) 4 - Not connected 5 - Not connected
1 - Shield 2 - Signal (-) 3 - Signal (+) 4 - Not connected 5 - Not connected
10
4.5 Ethernet connection
The xtures on a data link are connected to the Ethernet with ArtNet communication protocol.The control soft­ware running on your PC (or light console) has to support Art-Net protocol. Art-Net communication protocol is a 10 Base T Ethernet protocol based on the TCP/IP.Its purpose is to allow transfer of large amounts of DMX 512 data over a wide area using standard network technology.
IP address is the Internet protocol address.The IP uniquely identies any node (xture) on a network. The Universe is a single DMX 512 frame of 512 channels.
The Robin Spiider is equipped with 8-pin RJ- 45 socket for Ethernet input.Use a network cable category 5 (with four “twisted” wire pairs) and standard RJ-45 plugs in order to connect the xture to the network.
RJ-45 socket (front view): RJ-45 plug (front view):
1- TD+ 5- Not connected
2- TD- 6- RX-
3- RX+ 7- Not connected
4- Not connected 8- Not connected
Patch cables that connect xtures to the hubs or LAN sockets are wired 1:1,that is,pins with the same numbers
are connected together: 1-1 2-2 3-3 4-4 5-5 6-6 7-7 8-8
If only the xture and the computer are to be interconnected,no hubs or other active components are needed.A cross-cable has to be used:
1-3 2-6 3-1 4-8 5-7 6-2 7-5 8-4 If the xture is connected with active Ethernet socket (e.g. switch) the network icon will appear at the
bottom right corner of the screen:
Direct Ethernet operation
Connect the Ethernet inputs of all xtures with the Ethernet network. Option “Artnet (gMaI or gMA2)" has to be selected from “Ethernet Mode” menu on the xture. Set IP address (002.xxx.xxx.xxx / 010.xxx.xxx.xxx) and the Universe.
(DMX address=131) (DMX address=30) (DMX address=1) IP addres=002.168.002.004 IP addres=002.168.002.003 IP addres=002.168.002.002 Universe=1 Universe=1 Universe=1
An advised PC setting: IP address: 002.xxx.xxx.xxx / 010.xxx.xxx.xxx (Di󰀨erent from xture IP addresses)
NET mask: 255.0.0.0
11
Ethernet / DMX operation
Options “Art2DMX” has to be selected from the “Ethernet Mode” menu on the rst xture (connected to the Ethernet) in the xture chain,next xtures have standard DMX setting. Connect the Ethernet-input of the rst xture in the data chain with the network. Connect the DMX output of this xture with the input of the next xture until all xtures are connected to the DMX chain.
Caution: At the last xture, the DMX chain has to be terminated with a terminator. Solder a 120 Ω resistor between Signal (–) and Signal (+) into a XLR-plug and connect it in the DMX-output of the last xture.
Example:
DMX address=1 DMX address=49 DMX address=131 IP addres=002.168.002.002 Universe=0
DMX address=1 DMX address=49 DMX address=131 IP addres=002.168.002.003 Universe=1
12
4.6 Wireless DMX operation
The wireless version of the Robin Spiider is equipped with the Lumen Radio CRMX module and antenna for receiving DMX signal. CRMX module operates on the 2.4 GHz band.
The item " Wireless " from the menu "DMX Input" allows you to activate receiving of wireless DMX (Person­ality--> DMX Input -->Wireless.). First two options from the "DMX Input" menu are stated in DMX chart as well (channel Power/Special functions , range of 10-19 DMX). If DMX input option is changed by DMX command, the change is permanently written into xture´s memory.
DMX range of 10-19 switching xture to the wired/wireless operation is active only during rst 10 sec­onds after switching the xture on.
After switching the xture on, the xture checks both modes of receiving DMX in the following order:
1. For the rst ve seconds, the xture receives DMX signal from the wired input. If the Power/Special functions channel is set at some DMX input option, the xture will receive DMX value according to this option. If DMX input option is set to the wired input , this option is saved and checking procedure is nished. If DMX input option is not set, the xture continues next 5 seconds in scanning wireless DMX signal-see point 2.
2. For the next 5 seconds the xture receives wireless DMX signal and again detects if the Power/Special functions channel is set at some DMX input option, if not, the xture will take option which is set in the xture menu "DMX Input".
To link the xture with DMX transmitter. The xture can be only linked with the transmitter by running the link procedure at DMX transmitter . After linking , the level of DMX signal ( 0-100 %) is displayed in the menu item “Wireless State“ (Information
-->Wireless State).
To unlink the xture from DMX transmitter. The xture can be unlinked from receiver via the menu item “ Unlink Wireless Adapter“ (Information--> Wireless State --> Unlink Wireless Adapter.).
Note: If the option "Wireless In/XLR Out" is selected (Personality--> DMX Input -->Wireless In/XLR Out), the xture receives wireless DMX and sends the signal to its wired DMX output. The xture behaves as " Wireless/
Wired" adapter.
Example:
13
5. Remotely controllable functions
Virtual colour wheel
This wheel contains 66 preset colours, rainbow e󰀨ect in both directions is available.
Colour temperarature correction (CTC)
This channel allows to set calibrated white colour from range of 8000K-2700K.
RGBW or CMY colour mixing system
The RGBW colour mixing system is based on red, green, blue and white high power LEDs. Option for switching the xture to the CMY colour mixing system is available.
Colour Mix control
The Colour Mix control channel denes relation between global colours (RGBW, CTO, Virtual colour wheel) and individual RGB pixels or Kling-Net. Global = Global Colours (RGBW, CTO, Virtual Color Wheel) Pixel = Pixel Colors (RGB individual pixels or Kling-Net)
DMX value Function
0-9 Global colours (Global has priority) 10-19 Maximum mode (highest values have priority) 20-29 Minimum mode (lowest values have priority) 30-39 Multiply mode (multiply Global and Pixel) 40-49 Addition mode (Global + Pixel) - default 50-59 Subtraction mode (Global – Pixel) 60-69 Inverted Subtraction mode (Pixel – Global) 70-79 Coloured background
80-127 Reserved
128 Global colours (Global has priority) 129-254 Crossfade (crossfade between Global and Pixel) 255 Pixel colours (Pixel has priority) E.g. If you wish to control RGBW channels, set the Colour Mix Control channel to 0 DMX, if you need to use pixel e󰀨ects, set the Colour Mix Control channel to 255 DMX.
Flower E󰀨ect
The ower e󰀨ect rotating in both directions allows to create many dynamic e󰀨ects.
Zoom
Motorized zoom o󰀨ers beam range of 4° to 50°.
Pixel control and pixel e󰀨ects
19 RGB pixels allow you to create many e󰀨ects or use 90 pre-dened pixel e󰀨ects Pixel order:
Dimmer/Shutter unit
Smooth 0 - 100 % dimming is provided by the electronic control unit. This unit is also used for strobe e󰀨ects
with variable speed.
14
Pan/Tilt
Precise pan/tilt movement due to built-in electronic motion stabilizer. The electronic motion stabilizer ensures precise position of the xture´s head during its movement and reduces its swinging when the truss shakes. Pan movement range: 540°,tilt movement range: 230°.
15
6. Control menu map
Default settings=Bold print
Tab Level 1 Level 2 Level 3 Level 4 Level 5 Level 6
Addressing Settings DMX Address 001-255
-
DMX Preset Mode 1, Mode 2,
Mode 3, Mode 4
Ethernet Settings Ethernet Mode Disable
ArtNet
gMAI
gMA2
sACN
Ethernet To DMX O󰀨, On
IP Address/Net Mask Default IP Address
Custom IP Address
Net Mask
ArtNet Universe 0-255
MANet settings MANetI/II Universe 01-256
MANet Session ID 01-32
sACN Settings sACN Universe 00001-32000
sACN Priority 0-255
Klingnet Settings Disable
Enable
Information Fixture Times Power On Time Total Hours
Resetable Hours
Air Filters Elapsed Time
Alert Period 10-300
Fixture Temperatures
LEDs Temperature Current
Maximum NonRes.
Maximum Res.
Base Temperature Current
Maximum NonRes.
Maximum Res.
DMX Values Pan
:
Blue Pixel 19
Wireless State Signal Quality
Unlink Wireless Adapter
Power Channel State
Software Versions Display System
Module M
Module DR
Module PX
Product IDs Mac Address
RDM UID
RDM Label
View Logs Fixture Errors
Fixture States Power On
Power O󰀨
Fixture Position
Fixture Temperatures LEDs Temperatures
Base Temperatures
16
Tab Level 1 Level 2 Level 3 Level 4 Level 5 Level 6
Personality
DMX Presets Mode 1
:
Mode 6
:
Mode 10
View Selected Preset
DMX Input Wired Input
Wireless Input
Wireless In/XLR Out
Pan/Tilt Settings Pan Reverse O󰀨, On
Tilt Reverse O󰀨, On
Pan/Tilt Feedback O󰀨, On
Pan/Tilt mode Time
Speed
Pan/Tilt EMS On, O󰀨
Microphone Sen­sitivity
1-10-20
Blackout Settings Blackout During M.C. O󰀨, On
Blackout while: Pan/Tilt moving O󰀨, On
Colour Mixing Mode
RGBW
CMY
White Point 8000K O󰀨, On
Tungsten E󰀨. Sim. O󰀨
750W
1000W
1200W
2000W
2500W
Dimmer Curve Linear
Square Law
Init E󰀨ect Positions Pan 0-255
:
Dimmer Fine 0-255
Screen Settings Display Intensity 1-10
Screen Saver Delay O󰀨-10min.
Touchscreen Lock O󰀨-10min.
Recalibrate Touchscreen
Display Orientation Normal
Inverted
Auto
Temperature Unit °C,°F
Fan Mode Auto
High
Date & Time Settings
Default Settings
Manual Control Reset Functions Total System reset
Pan/Tilt reset
Zoom Reset
Flower E. Reset
Manual E󰀨ect Con-
trol
Pan 0-255
:
Blue Pixel 19 0-255
Loading...