Robin RGV13000T, RGV12000 User Manual

MANUAL
Models
RGVl2000 /13OOOT GENERATORS
PUB-GS1328 Rev. Ol/OO
Section
Title
Page
4.CONSTRUCTlONANDFUNCTlON
l l l l l l l l l l l l l l l l l l
7
4-l CONSTRUCTlON . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
J-2 FUNCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
4-3 DESCRIPTION andGENERATOROPERATlON l .
l l l l
. . .
l l l l l l
16
5. SAFETY PRECAUTIONS
l
o
l l l l l l l l l l l l l l
-
l l l l l
18
6. RANGE OF APPLICATIONS
l l l l l l l l l l l l l l l l l l l l l
19
7. MEASURING PROCEDURES
l l l l l l l l l l l l l l l l l l l l
22
7-l MEASURING INSTRUMENTS
l l l l l l l l l l l l l l
. . -
l l l l l l
22
7-2 AC OUTPUT MEASURING . . . . . . . . . . . . . . . . . . . . . . . . . 24
7-3 DC OUTPUT MEASURING . . . . . . . . . . . . . . . . . . . . . . . . . 24
8. CHECKING FUNCTIONAL MEMBERS
l l l l l l l l l l
- -
l l l l
26
8-l PlLOTlAMPandVOLTMETER
l l l l l l l l l l l l l l
- . .
l l
.
l l l
26
&2ACRECEpTACLES . . . . . . . . . . . . . . . . . . . . . . . . . . . .
26
8-3 AC SWITCH (NO-FUSE BREAKER)
l l l l l l l l l
.
l l
. . . - .
l l l l
27
8-4 STATOR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
8-5 ROTOR ASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . .
28
8-6 BRUSH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
8-7 A.V.R (AUTOMATIC VOLTAGE REGULATOR)
l l l l l l
. . l .
l l l l l l
29
8-8 CURRENTTRANSFORMER (RGV13000T only)
l l l l
. . -
l l l l l l l l
30
8-9 ECU (ELECTRONIC CONTROL UNIT) .
l l l l l l l l l l
-
l l
. l . .
l l
30
8-10 IDLE CONTROL UNIT (RGV12000 only) .
l l l l l l l l l
.
l l
. .
l l l
31
8-11 DIODE UNIT (RGV13000T only)
l l l l l l l l l l
. l . - . .
l l l l l l
32
9. DISASSEMBLY and REASSEMBLY
l l l l l l l l l l l l l l l l l
32
9-l PREPARATION and PRECAUTIONS l . . .
l l l l l
. . . . . . l .
l l l
32
g-2COMpONENTpARTS . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
9-3 GENERATOR ASSEMBLING PROCEDURES
l l l
- .
l l
. .
l l l l l l l
- 37
10. TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . 40
10-1 NO AC OUTPUT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
lO-2ACVOLTAGEIST00HlGHORTOOLOW .
l l
. - . - . . l . l . l .
l l
40
103 AC VOLTAGE IS NOMINAL AT NO-LOAD, BUT LOAD CANNOT BE APPLIED
l l
40
10-4 ENGINE DOSE NOT RUN . . . . . . . . . . . . . . . . . . . . . . . . . 41
11. WIRING DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . 42
NOTE
This Service Manual excludes information for engine.
As for the total servicing information as a generator set, please refer in conjunction with the
Robin EH63-65 OHV Engine Service Manual.
-02-

1. SPECIFICATIONS

Model
Type
Rated frequency
8 Rated voltage
E Q, Maximum output
2 .
Rated output Power factor
RGV12000
Brush, Self-exciting,
2-pole, Single phase
12OV I 240V
12OOOVA 1 OOOOVA
1.0
60Hz
RGV13OOOT
Brush, Self-exciting,
2-pole, 3-phase
12OV I 208V
13OOOVA 1 OOOOVA
0.8
Voltage regulator
Model
Type
E
Displacement
z Maximum output
W
Fuel
A.V.R type
C.T. type
EH65D EH63D
V-Twin cylinder, Air-cooled, 4-stroke, Overhead valve engine
653 cm3
22 HP/ 3600 rpm 18 HP/ 3600 rpm
Unleaded automobile gasoline
I
‘Oil capacity 1.55 liters
Starting system Fuel tank capacity Rated continuous
314 Rated operation per a tankful of fuel
Rated
Electric starter
43liters (21.5liters x 2) Approx. 8.8 hours Approx. 9.5 hours Approx. 8.0 hours Approx. 8.7 hours
Noise level Rated (dB-7m)
77.0 dB 77.0 dB
5 Large
&
g Width
.­n High
820 mm 605 mm (752 mm *I) 760 mm (845 mm ‘I)
Dry weight
141 kg (149 kg ‘2)
‘1: ( ) shows dimensions with castors.
‘2: ( ) shows dry weight with castors installed.
143 kg (151 kg l *)
-l-

2. PERFORMANCE CURVES

l
RGV12000 / 60Hz (9.5 KW240V)
(Hz)
63
HZ
62
.I1
61
60
------------------------------------------
(VI
250
(125)
240
24OVl12OV
(120)
230
(115)
220
(110)
I/~~~~~~~~~
112
Load
,--­\
4/4
Rated
. RGV13000T / 60Hz (12OW208V)
(Hz)
63
62
61
60
230
T
220
t
208V
0
l/2
414
Load
Rated
-2-
3. GENERAL DESCRIPTION OF GENERATOR
TANK CAP
iLTANK
COOLING AIR
/ INLET PORT
K
/FUEL COCK
BATTERY
STOPPER
OIL FILLER CAP
SPARK PLUG CAP
CHbKE KNOB
(RGV13000T only)
CONNECTOR FOR
REMOTE CONTROL
(RGV12000 only)
END COVER
(RGV13000T only)
OIL GAUGE
OIL DkAlN
PLUG
‘ELECTRIC STARTER
-3-
CONTROL PANEL
(RGVI 2000)
OIL PURESSURE
VOLT METER
WARNING LAMP
NO-FUSE BREAKER
\
PILOT LAMP
I
HOUR METER
EARTH (GROUND)
CONNECTOR AC RECEPTACLE
TERMINAL
FOR REMOTE CONTROL
(RGVI 3000T)
OIL PURESSURE
VOLT METER
WARNING LAMP
NO-FUSE BREAKER
\
PILOT LAMP
/
HOUR METER
KEY SWITCH
c AUTO IDEL
SWITCH
:-.
I
EARTH (GROUND)
TERMINAL
KEY SWITCH
AC RECEPTACLE AC OUTPUT TERMINAL
-4-
SERIAL NUMBER Serial number is stamped on the label stuck on the end cover.
NOTE : Always specify serial number when inquiring about the generator or ordering spare parts in order
to get correct parts and accurate service.
(RGV13000T)
(RGV12000)
SERIAL NUMBER stamped label
SERIAL NUMBER stamped label
-5-
4. CONSTRUCTION AND FUNCTION

4-l CONSTRUCTION

END COVER
BRUSH HOLDER
(RGV13000T only)
\
STATOR COMPLETE
STATOR BOLT
\ REAR COVER I
ROTOR COMPLETE
‘y
/ I’
\
\
FRONT COVER
BALL BEARING
I
TROUGH BOLT
. .
SLIP RING
I
MOUNT RUBBER
4-2 FUNCTION
4-2-l STATOR
The stator consists of a laminated silicon steel sheet core, a main coil and a condenser coil which are wound in the core slots. The condenser coil excites the rotor field coil which generates AC voltage in the main coil. -
-6-
4-2-2
ROTOR
The rotor consists of a laminated silicon steel sheet core and a field coil which is wound over the core.
DC current in the field coil magnetizes the steel sheet core. Two permanent magnets are provided for the primary exciting action (RGV13OOOT).
Slip rings are provided on the rotor shaft to
receive DC exciting current from AVR
(RGV12000) and diode unit (RGVl3000T).
A surge absorber is mounted inside of the
insulator.
4-2-3 BRUSH I BRUSH HOLDER
An exciting current is supplied from the A.V.R to the rotor. The brushes are made of carbon
and the brush-holder of plastic.
It is necessary to keep the contact pressure
between the brushes and slip rings withing
specific limits. Thus, care must be taken of
brush length.
I
-7-
4-2-4 CURRENT TRANSFORMER
I DIODE UNIT (RGV13000T only)
The current transformer and diode unit will perform a role to step up the voltage lowered by the
load and stabilize the output voltage.
CURRENT TRANSFORMER
4-2-5 A.V.R
(AUTOMATIC VOLTAGE REGULATOR) (RGV12000 only)
The automatic voltage regulator employs an
electronic circuit to automatically regulate voltage.
4-2-6 ECU (ELECTRONIC CONTROL UNIT)
ECU controls the start/stop of an engine
enabling the fuel cut while stop.
It also automatically stops the engine if an
abnormal oil pressure occurs.
-8-
DIODE UNIT
Function
Warning lamp
Electric starter control
Fail-safe function
Self checking function
for warning lamp bulb
Description of Operation
When the lubrication oil pressure drops below the safety limit (Oil pres­sure becomes less than 1 kg/cm2), the warning lamp turns on and off, and the engine stops automatically. The warning lamp turns off after 3 minutes.
When the the engine started and reaches 1,050 rpm, the electric starter is automatically stopped.
When the engine operating, the electric starter can not start.
When the key switch or the remote control switch is turned to ‘START”, the fuel cut-off valve of the carburetor opens. When the key switch or the remote control switch is turned to “STOP”, the fuel cut-off valve closes.
If the electric starter is locked by any reason, the electric starter is shut off automatically after 3 seconds.
When the engine dose not start (engine speed dose not reach 1,050 rpm), the electric starter is stopped after 21 seconds.
When the remote controller is connected, the electric starter dose not run when the switch of remote controller is turned “OFF” even if the key switch on the generator is turned to “START”.
When the key switch or remote control switch is turned to ‘START”, the warning lamp lights up for a moment to indicate that the bulb for the warn-
ing lamp is normal.
4-2-7 IDLE CONTROL UNIT
(RGV12000 only)
The idle control unit has a function to check
that the generator has a load or not, then
decrease the engine rotation at no load or
increase it to the rated rotation.
The idle control unit releases throttle valve
when the applied load current exceeds
0.04A.
NOTE :
It is normal that the engine speed goes up for a moment when you turn the key switch to “STOP” while the Auto Idle Switch is in “ON”
position.
IDLE CONTROL UNIT
-9-
4-2-8 OIL PRESSURE SWITCH
The oil pressure switch sends a signal to ECU to stop the engine when the engine oil pressure
drops to 1 .O kg/cm2
.r?
4-2-9 RELIEF VALVE
The relief valve begins to open when the engine’s oil pressure increases above 3.0 kg/cm2
OIL FILTER
I CAMSHAFT
OIL
PRESSljRE SWITCH
OIL PUMP FILTER
4-2-10 AC SWITCH (NO-FUSE BREAKER)
The AC switch (no-fuse breaker) protects the generator from getting damage by overloading or short circuit in the appliance. The capacity of AC switch (no-fuse breaker) is as follows ;
Model
Specification
RGV12000
60Hz-12OV/24OV
RGVl3000T
60Hz-12OV/208V
No-fuse Breaker
39A 24A
Object of Protection Total output amperage Total output amperage
n
. .
- lo-
4-2-l 1 AC Receptacle and Terminals
AC receptacle and terminals are used for taking AC output power from the generator. A total of 4 kinds of receptacle and terminals, each varying in rated voltage and current from.
another, are used. As many AC terminals as the receptacles, each matching the corresponding receptacle, are provided.
The rated current for each receptacle and terminal is shown as follows;
CAUTION
Be careful not to use the receptacles and terminal beyond the specified amperage limits to prevent burning.
Total 5Oh or less
(RGV12000)
CAUTION
To connect the appliance to the locking
type receptacle, insert the plug in to the
receptacle and then turn it clockwise to lock.
i +.
20A or less
I
Rated curient or less
(RGV13000T)
(RGV12000)
-ll-
n
Check the amperage of the receptacles used referring to
TABLE 1,
and be sure not to take a
current exceeding the specified amperage.
n
Be sure that the total wattage of all appliances dose not exceed the rated output of the gen­erator.
Style
Ampere
up
to20A
Receptacle
AC plug
NEMA NEMA
5-20R 5-2OP
Description
GFCI (Ground Fault Circuit interrupter) Receptacle, duplex
(RECl)
up to 30A
up to 30A
up to 50A
NEMA
L!5-30R
NEMA
L14-30R
NEMA Locking Receptacle
L5-30 P
(REC2)
NEMA
Locking Receptacle
L143OP
(REC3)
Locking Receptacle (REC4)
TABLE 1
NOTE :
When the no-fuse breaker turns off during operation, the generator is over loaded or the appli­ance is defective. Stop the generator immediately, check the appliance and / or generator for overloading or detect and have repaired as necessary by Robin dealer or service shop.
-[CAUTION]
The duplex 120V receptacle is protected by a GFCI (Ground Fault Circuit Interrupter).
GFCI shuts off the output current from the duplex 120V receptacle when a ground fault occurs in the generator or the appliance.
Please note that other receptacles are not protected by GFCI.
GFCI RECEPTACLE
After starting the engine, check the GFCI for proper functioning by the following test procedure.
n
Push yellow TEST button, The red RESET button will pop out exposing the word TRIP. Power is now off at the outlets protected by the GFCI, indicating that the device is functioning
properly.
m If TRIP dose not appear when testing, do not use the generator. Call a qualified electrician.
n
To restore power, push RESET button.
- 12-