Robin MMX Spot, Robin MMX Spot Wireless DMX CRMX, Robin Spot Wireless DMX CRMX, MMX Spot Wireless DMX CRMX User Manual

1
Version 2.0
2
Table of contents
1. Safety instructions ......................................................................................................... 3
2. Operating determination ................................................................................................ 4
3. Fixture exterior view ...................................................................................................... 5
4. Installation....................................................................................................................... 6
4.1 Connection to the mains ............................................................................................6
4.2 Installing the lamp ...................................................................................................... 7
4.3 Lamp adjustment .......................................................................................................7
4.4 Replacing rotating gobos ..........................................................................................8
4.5 Replacing graphic wheels ......................................................................................... 9
4.6 Rigging the xture .................................................................................................... 10
4.7 DMX-512 connection ................................................................................................12
4.8 Ethernet connection ................................................................................................. 13
5. Remotely controllable functions ................................................................................. 15
6. Control menu map ........................................................................................................ 16
7. Control menu ............................................................................................................... 19
7.1 Tab " Address" ......................................................................................................... 20
7.2 Tab "Information"...................................................................................................... 21
7.3 Tab "Personality" ...................................................................................................... 23
7.5 Tab "Stand-alone" ................................................................................................... 25
7.6 Tab "Service"............................................................................................................ 26
7.7 Icon "Lamp menu" .................................................................................................... 28
8. RDM ...............................................................................................................................28
9. Wireless DMX operation ..............................................................................................29
10. Error and information messages .............................................................................. 30
11. Technical Specications............................................................................................ 33
12. Maintenance and cleaning ......................................................................................... 38
13. ChangeLog ................................................................................................................. 38
Robin MMX Spot
3
CAUTION!
Keep this device away from rain and moisture!
Unplug mains lead before opening the housing!
FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY
BEFORE YOU INITIAL START - UP!
1. Safety instructions
Every person involved with installation and maintenance of this device have to:
- be qualied
- follow the instructions of this manual
CAUTION!
Be careful with your operations.
With a high voltage you can suffer
a dangerous electric shock when touching the wires!
This device has left our premises in absolutely perfect condition. In order to maintain this condition and to en­sure a safe operation, it is absolutely necessary for the user to follow the safety instructions and warning notes written in this manual.
Important:
The manufacturer will not accept liability for any resulting damages caused by the non-observance of this
manual or any unauthorized modication to the device.
Please consider that damages caused by manual modications to the device are not subject to warranty.
During the operation the housing becomes hot (up to 100°C). Allow the xture to cool approximately 20 minutes
prior to manipulate with it.
Make sure that the available voltage is not higher than stated on the rear panel.
Always plug in the power plug least. Make sure that the power-switch is set to off-position before you connect the device to the mains. The power plug has to be accessible after installing the device.
Make sure that the power-cord is never crimped or damaged by sharp edges. Check the device and the power­cord from time to time.
Always disconnect from the mains, when the device is not in use or before cleaning it. Only handle the power­cord by the plug. Never pull out the plug by tugging the power cord.
This device falls under protection class I. Therefore it is essential to connect the yellow/green conductor to earth.
The electric connection, repairs and servicing must be carried out by a qualied employee.
Do not connect this device to a dimmer pack.
Do not switch the xture on and off in short intervals as this would reduce the lamp’s life.
During the initial start-up some smoke or smell may arise. This is a normal process and does not necessarily mean that the device is defective.
Do not touch the device’s housing bare hands during its operation (housing becomes hot)!
For replacement use lamps and fuses of same type and rating only.
CAUTION ! EYE DAMAGES !
Avoid looking directly into the light source
(meant especially for epileptics) !
4
2. Operating determination
This device is a moving head for creating decorative effects and was designed for indoor use only.
If the device has been exposed to drastic temperature uctuation (e.g. after transportation), do not switch it on
immediately. The arising condensation water might damage your device. Leave the device switched off until it has reached room temperature.
Never run the device without lamp!
Before switching the xture OFF, turn the lamp OFF and allow the xture to cool for a while.
Do not shake the device. Avoid brute force when installing or operating the device.
Never lift the xture by holding it at the projector-head, as the mechanics may be damaged. Always hold the xture at the transport handles.
When choosing the installation-spot, please make sure that the device is not exposed to extreme heat, moisture or dust. There should not be any cables lying around. You endanger your own and the safety of others!
The minimum distance between light output and the illuminated surface must be more than 5 meters.
Make sure that the area below the installation place is blocked when rigging, derigging or servicing the x­ture.
Always x the xture with an appropriate safety rope. Fix the safety rope at the correct holes only.
Only operate the xture after having checked that the housing is rmly closed and all screws are tightly fas-
tened.
The lamp must never be ignited if the objective-lens or any housing-cover is open, as discharge lamps may
explode and emit a high ultraviolet radiation, which may cause burns.
The maximum ambient temperature 45°C must never be exceeded.
CAUTION!
The lens has to be replaced when it is obviously damaged,
so that its function is impaired, e. g. due to cracks or deep scratches!
Operate the device only after having familiarized with its functions. Do not permit operation by persons not
qualied for operating the device. Most damages are the result of unprofessional operation!
CAUTION!
The lamp has to be replaced when it is damaged
or deformed due to the heat!
Please use the original packaging if the device is to be transported.
Please consider that unauthorized modications on the device are forbidden due to safety reasons!
If this device will be operated in any way different to the one described in this manual, the product may suffer damages and the guarantee becomes void. Furthermore, any other operation may lead to dangers like short-
circuit, burns, electric shock, burns due to ultraviolet radiation, lamp explosion, crash etc.
5
3. Fixture exterior view
Rear panel of the base: 1 - DMX output (3-pin XLR) 2 - DMX output (5-pin XLR)
3 - Ethernet input (RJ45) 4 - Power switch 5 - Power input
(Neutrik PowerCon) 6 - DMX input (3-pin XLR) 7 - DMX input (5-pin XLR)
8 - Fuse holder
Front panel of the base: 1 - QVGA touch screen 2 - ESCAPE button 3 - NEXT button 4 - PREVious button 5 - ENTER/DISPLAY ON button
The head should be locked for transportation- the tilt lock latch (2) and the pan lock latch (3) have to be in the
locked positions. To unlock the head, move these latches to unlock positions before operating the xture.
1 - Front lens 2 - Air lter 3 - Tilt lock 4 - Pan lock 5 - Air lter 6 - Arm 7 - Base 8 - Arm 9 - Moving head
The ENTER/DISPLAY ON button also serves for switching the display on when the xture is disconnected
from the mains.
6
4. Installation
Fixtures must be installed by a Qualied electrician in accordance with all
national and local electrical and construction codes and regulation.
4.1 Connection to the mains
For protection from electric shock, the xture must be earthed!
The Robin MMX Spot is equipped with auto-switching power supply that automatically adjusts to any 50/60Hz AC power source from 100-240 Volts.
For use with 100-120 V supplies, the main 8 A fuse has to be exchanged for 15 A fuse which is enclosed in the packing.
To install the 15 A fuse:
1. Disconnect the xture from AC power.
2. Unscrew the fuse holder on the rear panel of the base with a at-tip screwdriver from the housing
(anticlockwise).
3. Remove the 8 A fuse from the fuse holder.
4. Put the 15 A fuse in the fuse holder.
5. Replace the fuse holder in the housing and screw it fully clockwise.
Install a suitable plug on the power cord, note that the cores in the power cord are coloured according to the
following table. The earth has to be connected! If you have any doubts about proper installation, consult a qualied electrician.
Core (EU) Core (US) Connection Plug Terminal Marking
Brown Black Live L
Light blue White Neutral N
Yellow/Green Green Earth
7
4.2 Installing the lamp
DANGER ! Install the lamp with the device switched off only. Unplug from mains before !
To insert the new lamp.
1. Disconnect the xture from power and allow it to cool
at least 15 minutes.
2. Make sure that the xture´s head is in the position as
shown on the picture (notices on the lamp cover are in readable position) .Loosen the two quarter-turn fasteners (1) marked “X,Y“ on the lamp cover to open this cover.
3. Holding the lamp by its ceramic base, carefully turn the lamp to the left to loosen the lamp from the lamp holder. Gently pull the lamp out of the lamp holder
4. Holding the new lamp by its ceramics base, gently insert the lamp to the lamp socket and turn the base to the right. Make sure that the lamp is installed tightly into the lamp socket.
Do not install a lamp with a higher wattage! A lamp like
this generates temperatures the device is not designed for. Damages caused by non-observance are not subject to warranty.
Please follow the lamp manufacturer‘s notes! Do not touch the glass bulb bare hand during the installation!
5. Re-insert the lamp cover and tighten the two quarter-turn
fasteners (1).
6. Switch on the xture.
7. Align the lamp (see instructions below)
8. Reset the "Lamp On Time” and "Lamp Strikes” counters in the menu "Information”.
Do not operate this xture with open lamp cover!
4.3 Lamp adjustment
The lamp holder is aligned at the factory. Due to differences between lamps,the ne adjustment may improve
light performance:
To adjust the lamp in the xture.
1. Switch on the xture and after its reset turn on the
lamp.
2. Go to the "Service" menu and select the item "Adjust
Lamp" to project the light beam on the wall.
3. Use items in this menu to focus the light beam and set
the item HotSpot at 0 DMX .
4. Turn adjustment screws marked “A, B, C” (2) one after
another until you reach a max. light intensity (.
5.
Center the hot-spot (the brightest part of the beam)
using these
3 adjustment screws (2).
8
4.4 Replacing rotating gobos
Install gobos with the device switched off only.
Unplug from mains before!
To replace rotating gobos.
1. Disconnect the xture from mains and allow it to cool.
2. Remove the bottom plastic cover of the head by loosening the 4 quarter-turn fasteners on the cover.
3. Gently pull up the gobo holder from the rotation gobo wheel
.
4. Remove the spring gobo-lock with an appro
priate tool (e.g. small-bladed screwdriver) and remove it.
Do not touch the surface of the pattern of the glass gobo with bare ngers.
5. Remove the original gobo and insert the new one (glazy side towards the lamp). Insert the spring-gobo lock
to secure it in the gobo holder.
6. Insert the gobo holder back under the distance slots into rotating gobo wheel
.
5. Replace the bottom cover before applying power.
9
4.5 Replacing graphic wheels
Install graphic wheels with the device switched off only.
Unplug from mains before!
The dual graphic wheel consists of two graphic wheels. Both wheels has to be changed at the same time. To replace graphic wheels.
1. Disconnect the xture from mains and allow it to cool.
2. Remove the bottom plastic cover of the head by loosening the 4 quarter-turn fasteners on the cover.
3. Tilt up the dual graphic wheel.
4. Remove the spring graphic wheel - lock with an appro
priate tool (e.g. small-bladed screwdriver) and remove
it.
5. Remove the rst original graphic wheel and insert the new one (glazy side towards the lamp, black side
toward the objective!). Insert the spring-gobo lock to secure it in the graphic wheel holder.
6. Use the same steps to change the second graphic wheel
.
5. Put the bottom cover back before applying power.
10
4.6 Rigging the xture
The installation of the xture has to be built and constructed in a way that it can hold 10 times the weight for 1
hour without any harming deformation.
The installation must always be secured with a secondary safety attachment, e.g. an appropriate catch net. This secondary safety attachment must be constructed in a way that no part of the installation can fall down if the main attachment fails.
When rigging, derigging or servicing the xture staying in the area below the installation place, on bridges,
under high working places and other endangered areas is forbidden.
The operator has to make sure that safety-relating and machine-technical installations are approved by an expert before taking into operation for the rst time and after changes before taking into operation another time.
The operator has to make sure that safety-relating and machine-technical installations are approved by an
expert after every four year in the course of an acceptance test.
The operator has to make sure that safety-relating and machine-technical installations are approved by a skilled person once a year.
The projector should be installed outside areas where persons may walk by or be seated.
IMPORTANT! OVERHEAD RIGGING REQUIRES EXTENSIVE EXPERIENCE, including (but not limited to)
calculating working load limits, installation material being used, and periodic safety inspection of all installation
material and the xture. If you lack these qualications, do not attempt the installation yourself, but instead use
a professional structural rigger. Improper installation can result in bodily injury or damage to property.
The xture has to be installed out of the reach of people.
If the xture shall be lowered from the ceiling or high joists, professional trussing systems have to be used. The xture must never be xed swinging freely in the room.
Caution: Fixtures may cause severe injuries when crashing down! If you have doubts concerning the safety of a possible installation, do not install the moving head!
Before rigging make sure that the installation area can hold a minimum point load of 10 times the xture’s
weight.
Danger of re !
When installing the device, make sure there is no highly inammable
material (decoration articles, etc.) in a distance of min. 1 m.
CAUTION!
Use 2 appropriate clamps to rig the xture on the truss.
Follow the instructions mentioned at the bottom of the base.
Make sure that the device is xed properly! Ensure that the
structure (truss) to which you are attaching the xtures is secure.
The xture can be placed directly on the stage oor or rigged in any orientation on a truss without altering its
operation characteristics .
For securing a xture to the truss install a safety wire that can hold at least 10 times the weight of the xture.
Use only safety wire with screw-on carabine. Pull the safety wire through the carrying handles and around the truss as shown on the pictures below.
Note: If the safety wire is too long, whip it several times around the trusss in order to attach the xture tight. In case of an accident, the way of the falling xture will be short.
.
11
Omega holders positions:
Truss installation
1.Bolt each clamp (1) to the omega holder (3) with M12 bolt and lock nut through the hole in the holder.
2.Fasten the omega holders on the bottom of the base by inserting both quick-lock fasteners (4) into the holes
of the base and tighten fully clockwise.
3. Pull the safety wire (2) through the carrying handles (5) and around the truss (6) as shown on the pictures
below. Securing the xture via one safety wire Securing the xture via two safety wires
When installing xtures side-by-side,
avoid illuminating one xture with another!
DANGER TO LIFE!
Before taking into operation for the rst time,the installation has to be approved
by an expert!
1-Clamps 2-Safety wire 3-Omega holders 4-Quick-lock fastener 5-Handles 6-Truss
12
4.7 DMX-512 connection
The xture is equipped with both 3-pin and 5-pin XLR sockets for DMX input and output.The sockets are wired
in parallel. Only use a shielded twisted-pair cable designed for RS-485 and 3-pin or 5-pin XLR-plugs and connectors in
order to connect the controller with the xture or one xture with another.
DMX - output DMX-input
XLR mounting-sockets (rear view): XLR mounting-plugs (rear view):
If you are using the standard DMX controllers, you can connect the DMX output of the controller directly with the DMX input of the rst xture in the DMX-chain. If you wish to connect DMX-controllers with other XLR-out­puts, you need to use adapter-cables.
Building a serial DMX-chain:
Connect the DMX-output of the rst xture in the DMX-chain with the DMX-input of the next xture. Always connect one output with the input of the next xture until all xtures are connected.
Caution: At the last xture, the DMX-cable has to be terminated with a terminator. Solder a 120 Ω resistor between Signal (–) and Signal (+) into a 3-pin XLR-plug and plug it in the DMX-output of the last xture.
1 - Shield 2 - Signal (-) 3 - Signal (+) 4 - Not connected 5 - Not connected
1 - Shield 2 - Signal (-) 3 - Signal (+) 4 - Not connected 5 - Not connected
13
4.8 Ethernet connection
The xtures on a data link are connected to the Ethernet with ArtNet communication protocol.The control soft­ware running on your PC (or light console) has to support Art-Net protocol. Art-Net communication protocol is a 10 Base T Ethernet protocol based on the TCP/IP.Its purpose is to allow transfer of large amounts of DMX 512 data over a wide area using standard network technology.
IP address is the Internet protocol address.The IP uniquely identies any node (xture) on a network. The Universe is a single DMX 512 frame of 512 channels.
The Robin MMX Spot is equipped with 8-pin RJ- 45 socket for Ethernet input.Use a network cable category 5
(with four “twisted” wire pairs) and standard RJ-45 plugs in order to connect the xture to the network.
RJ-45 socket (front view): RJ-45 plug (front view): 1- TD+ 5- Not connected 2- TD- 6- RX­ 3- RX+ 7- Not connected 4- Not connected 8- Not connected
Patch cables that connect xtures to the hubs or LAN sockets are wired 1:1,that is,pins with the same numbers
are connected together: 1-1 2-2 3-3 4-4 5-5 6-6 7-7 8-8
If only the xture and the computer are to be interconnected,no hubs or other active components are needed.
A cross-cable has to be used: 1-3 2-6 3-1 4-8 5-7 6-2 7-5 8-4
If the xture is connected with active Ethernet socket (e.g. switch) the network icon will appear at the bottom right corner of the screen:
Direct Ethernet operation
Connect the Ethernet inputs of all xtures with the Ethernet network. Option “ Artnet (gMaI or gMA2)" has to be selected from “Ethernet Mode” menu on the xture. Set IP address (002.xxx.xxx.xxx / 010.xxx.xxx.xxx) and the Universe.
(DMX address=150) (DMX address=39) (DMX address=1) IP addres=002.168.002.004 IP addres=002.168.002.003 IP addres=002.168.002.002 Universe=1 Universe=1 Universe=1
An advised PC setting: IP address: 002.xxx.xxx.xxx / 010.xxx.xxx.xxx (Different from xture IP addresses)
NET mask: 255.0.0.0
14
Ethernet / DMX operation
Options “Art2DMX” has to be selected from the “Ethernet Mode” menu on the rst xture (connected to the Ethernet) in the xture chain,next xtures have standard DMX setting. Connect the Ethernet-input of the rst xture in the data chain with the network. Connect the DMX output of this xture with the input of the next xture until all xtures are connected to the DMX chain.
Caution: At the last xture, the DMX chain has to be terminated with a terminator. Solder a 120 Ω resistor between Signal (–) and Signal (+) into a XLR-plug and connect it in the DMX-output of the last xture.
Example:
DMX address=1 DMX address=39 DMX address=150 IP addres=002.168.002.002 Universe=0
DMX address=1 DMX address=39 DMX address=150 IP addres=002.168.002.003 Universe=1
15
5. Remotely controllable functions
Lamp
The Robin MMX Spot is to be operated with a Philips MSR Platinum 35. Note: It is also important to note, that the discharge lamp is cold restrike types, that means, that they have to be cold before re-striking. For this reason, you have to wait about 5 minutes after having switched the lamp off before you can switch it on again. If you try to switch on the lamp within 5 minutes after having switched it off, the Robin MMX Spot will store this information and automatically ignite the lamp when the 5 minutes period
has expired.
Colour wheel
This wheel contains 6 replaceable 'SLOT&LOCK' dichroic lters + open.The colour wheel can be positioned
between two adjacent colours in any position. It is also possible to rotate the colour wheel continuously at dif­ferent speeds ("Rainbow effect“ in both directions).
CMY+CTO colour mixing system
The CMY color mixing system is based on graduated cyan, magenta, and yellow colour lters. A continuous range of colors may be achieved by varying the amount of each lter from 0 to 100%. Colour temperature correction lter lowers the colour temperature from 6200 K to 3200 K.
Dual graphic wheel
The wheel consists of 2 graphic wheels rotating in both directions with variable speed which create wide spec­trum of graphic effects. 30 animation macros in relation to focus channel allows to set many new images.
Rotating gobo wheels
The xture includes 2 rotating gobo wheels. Each rotating gobo wheel includes 7 gobos rotating in both direc­tions, indexable, replaceable "SLOT&LOCK” glass gobos + open position. Gobo positioning and gobo selection
speed is available as well as a gobo-shake function.
Prism
The 3-facet prism rotates in both directions at different speeds, 16 prism/gobo macros are available.
Frost
Frost module provides variable frost for ne frosting.
Iris
Motorized adjustable iris, wide range of variable pulse effects.
Zoom
Motorized zoom unit enables zoom between 8.5 °- 42.5° (for a gobo) and 9.8° – 46.5 ° (for an open hole).
Focus/Autofocus
Motorized focus allowes to focus beam from approx. 2 meters to innity.
Special function autofocus allows to keep focused image during zooming . Use "Focus" channel to focus the image , then select desired distance and effect which you need to focus at channel "Autofocus (priority & distance selection)". The right value at "Autofocus (priority & distance selection)" chanel can be typically in tolerance of + 2 DMX
-2DMX . You should try to set value , set focus and check min/max. zoom.
Note: If you use the Autofocus function in the program steps (scenes), there is important to switch off Autofocus before using it in the sequence of program steps. Step(Scene) Zoom Focus Autofocus 1 255 187 0 (hole) 2 255 181 7 (hole) 3 0 181 7 (hole) 4 0 165 139 (gobo 2) 5 255 165 139 (gobo 2) If you want to in the step 6 repeat the Autofocus scenes 2-5, you have to go to step 1, after that to the step 2,3...5 If you
will go to directly to the step 2, after that to the step 3.... the Autofocus will not work properly because the initial position of
the focus module will not be the same as it was in the step 1.
Hot-Spot
Fine movement of the glass reector allows to change the light intensity from the maximum in the centre of the
image to the evenly distributed light intensity.
Dimmer/Shutter unit
Smooth 0 - 100 % dimming is provided by the mechanical dimmer /shutter unit. This unit is also used for strobe
effects with variable speed.