Robe Stage Faze 1500AT User Manual

Version 1.1
2
3
Table of contents
1.Introduction...................................................................................................................... 3
2.Cautions ........................................................................................................................... 3
3.Unpacking & Inspection.................................................................................................. 4
4.Description of the device................................................................................................ 4
5. Fluid.................................................................................................................................5
5.1 General notes ...........................................................................................................................................5
5.2 Filling the uid tank....................................................................................................................................5
6. Operatting the StageFaze 1500 AT ............................................................................... 5
6.1 Selecting a location ...................................................................................................................................5
6.2 Putting into operation ................................................................................................................................6
6.2 Switching the StageFaze 1500 AT off.......................................................................................................6
7. Cleaning,care and maintenance ................................................................................... 9
8. Troubleshooting ............................................................................................................. 9
9. Specications ................................................................................................................. 9
3
1.Introduction
Thank you for choosing an ROBE StageFaze 1500 AT. You now own a rugged and powerful state-of-the-art machine. Prior to use, we suggest that you carefully read all of the instructions. By following the suggestions found in this user manual, you can look forward to the reliable and satisfactory performance of your ROBE Stage Faze 1500 AT machine for years to come.
Please follow these operation, safety and maintenance instructions to ensure a long and safe life for your fog machine.
2.Cautions
Risk of electric shock. Disconnect the appliance from the electric supply before
removing the cover.
Note: there are no user serviceable parts inside.
Danger of Electric Shock
Keep this device dry. For inside use only. Not designed for outside use. Prior to use take care to determine that the unit is installed at the rated voltage. Always unplug your ROBE Faze machine before lling its tank. Keep fog machine upright. Unplug the machine when not in use. This machine is not water - or splash-proof. If moisture, water, or fog liquid gets inside the housing, immediately unplug the unit and contact a service technician or your ROBE distributor before using it again. No user serviceable parts inside. Refer to your ROBE distributor or other qualied service personnel.
Danger of Burns
For adult use only. Never leave the unit running unattended. Never aim at persons directly and keep a minimum distance of 3 m to the nozzle. Faze machine output area is very hot. Avoid coming within 60 cm of the output nozzle during operation. Keep a minimum distance of 60 cm to all ammable, combustible objects and objects sensitive to heat. Locate the Faze machine in a well-ventilated area. Never cover the unit's vents. Never aim the output nozzle at open ames. If the supply cord is damaged, it must be replaced by manufacturer or its service agent or similarly qualified personnel in order to avoid a hazard. Always allow your StageFaze 1500 AT to cool down before attempting to clean or service it.
Danger of Explosion
Never add ammable liquids of any kind (oil, gas, perfume) to the Faze liquid. Use only original liquid recommended by ROBE distributor. Spilled uid or splashed uid droplets can cause slip hazard. Always make sure there is sufcient liquid in the Faze liquid tank. Operating this unit without liquid will cause damage to the pump as well as over-heating of the heater.
If your ROBE Faze machine fails to work properly, discontinue use immediately. Drain all fog liquid from the tank, pack the unit securely (preferably in the original packing material), and return it to your ROBE distributor for service. Always drain tank before mailing or transporting this unit. Never drink fog liquid. If it is ingested, call a doctor immediately. If fog liquid comes in contact with skin or eyes, rinse thoroughly with water.
Pay attention to all warning labels and instructions printed on the exterior of
StageFaze 1500 AT
People with health problems or problems of therespiratory tract or with an inclinati-
on for allergies should avoid any contact with articially-made fog.
Loading...