1. Safety instructions
Every person involved with installation and maintenance of this device have to:
- be qualiled
- follow the instructions of this manual
CAUTION!
Be careful with your operations.
With a high voltage you can suffer
a dangerous electric shock when touching the wires!
This device has left our premises in absolutely perfect condition. In order to maintain this condition and to ensure a safe operation, it is absolutely necessary for the user to follow the safety instructions and warning notes
written in this manual.
Important:
The manufacturer will not accept liability for any resulting damages caused by the non-observance of this
manual or any unauthorized modication to the device.
Please consider that damages caused by manual modications to the device are not subject to warranty.
Never let the power-cord come into contact with other cables! Handle the power cord and all connections with
the mains with particular caution!
Make sure that the available voltage is not higher than stated on the rear panel.
Always plug in the power plug least. Make sure that the power-switch is set to Off-position before you connect
the device to the mains. The power plug has to be accessable after installing the device.
Make sure that the power-cord is never crimped or damaged by sharp edges. Check the device and the powercord from time to time.
Always disconnect from the mains, when the device is not in use or before cleaning it. Only handle the powercord by the plug. Never pull out the plug by tugging the power cord.
This device falls under protection class I. Therefore it is essential to connect the yellow/green conductor to
earth.
The electric connection, repairs and servicing must be carried out by a qualied employee.
Do not connect this device to a dimmer pack.
Do not switch the xture on and off in short intervals as this would reduce the lamp’s life.
During the initial start-up some smoke or smell may arise. This is a normal process and does not necessarily
mean that the device is defective.
Do not touch the device’s housing bare hands during its operation (housing becomes hot)!
For replacement use lamps and fuses of same type and rating only.
CAUTION ! EYEDAMAGES !
Avoid looking directly into the light source
(meant especially for epileptics) !
3
Page 4
2.Operating determinations
This device is a moving-head for creating decorative effects and was designed for indoor use only.
If the device has been exposed to drastic temperature uctuation (e.g. after transportation), do not switch it on
immediately. The arising condensation water might damage your device. Leave the device switched off until
it has reached room temperature.
Never run the device without lamp!
Do not shake the device. Avoid brute force when installing or operating the device.
Never lift the xture by holding it at the projector-head, as the mechanics may be damaged. Always hold the
xture at the transport handles.
When choosing the installation-spot, please make sure that the device is not exposed to extreme heat, moisture
or dust. There should not be any cables lying around. You endanger your own and the safety of others!
The minimum distance between light output and the illuminated surface must be more than 1 meter.
Make sure that the area below the installation place is blocked when rigging, derigging or servicing the xture.
Always x the xture with an appropriate safety rope. Fix the safety rope at the correct holes only.
Only operate the xture after having checked that the housing is rmly closed and all screws are tightly fas-
tened.
The lamp must never be ignited if the objective-lens or any housing-cover is open, as discharge lamps may
explose and emit a high ultraviolet radiation, which may cause burns.
The maximum ambient temperature 45°C must never be exceeded. Otherwise, the lamp is switched off and
the xture is out of operation for 5 minutes.
CAUTION!
The lens has to be replaced when it is obviously damaged,
so that its function is impaired, e. g. due to cracks or deep scratches!
Operate the device only after having familiarized with its functions. Do not permit operation by persons not
qualied for operating the device. Most damages are the result of unprofessional operation!
CAUTION!
The lamp has to be replaced when it is damaged
or deformed due to the heat!
Please use the original packaging if the device is to be transported.
Please consider that unauthorized modications on the device are forbidden due to safety reasons!
If this device will be operated in any way different to the one described in this manual, the product may suffer
damages and the guarantee becomes void. Furthermore, any other operation may lead to dangers like shortcircuit, burns, electric shock, burns due to ultraviolet radiation, lamp explosion, crash etc.
4
Page 5
3. Description of the device
1 - Moving head
2 - Yoke
3 - Front lens
4 - Base
Rear panel of the base:
5 - Power switch
6 - Power cord
Install the lamps with the device switched off only.
Unplug from mains before !
To insert the lamp loosen the lamp cover at the rear of head (see the drawings ) by remowing the 3 fastening
screws which are marked "X,Y,Z".Carefully pull out the cover with the lamp socket assembly.If changing the
lamp, remove the old lamp from the socket. Insert the lamp to the socket.
Do not install a lamp with a higher wattage! A lamp like this generates temperatures the device is not designed for.Damages caused by non-observance are not subject to warranty. Please follow the lamp manufacturer‘s notes!Do not touch the glass-bulb with bare hands during the installation! Make sure that the lamp
is installed tightly into the lampholder system.
Reclose the lamp cover and tighten the 3 screws.
Before striking the lamp, reset the "LAti"and "LASt" counter s in the menu of the control board, by pressing the
"Up" and "Down" buttons together and then conrming with the Enter-button.
Lamp cover
3 fastening screws "X,Y,Z"
Do not operate this xture with opened housing-cover!
6
Page 7
4.2 Lamp adjustment
3 adjustment screws "A,B,C"
The ColorWash 250 AT lamp holder is aligned at the factory. Due to differences between lamps, ne adjustment may improve light performance.
Strike the lamp,open the shutter and set the dimmer intensity onto 100% and aim the light on a at surface
(wall).Center a hot-spot(the brightest part of the image) by using the 3 adjustment screws "A,B,C".Turn one
screw after another a quarter-turn clokwise(counter-clokwise) to set the hot-spot in the center of the image.If
you cannot detect the hot-spot,adjust the lamp until the light is evenly distributed.
4.3 Inserting/Exchanging colours
DANGER!
Install the colours with the device switched off only.
Unplug from mains before!
If you wish to change colours ,open the top cover of the head by loosening the 4 quarter-turn fasteners on the
top cover.
Gently bend out the colour module to release it from the 3 distance slots and eject it from the pressing snap.
Put the new colour module back under the pressing snap and push it to the distance slots.
colour-module
pressing snap
7
Page 8
4.4 Connection to the mains
Verify the power supply settings before applying power!
If you wish to change the power supply settings,see the chapter below.
Connect the xture to the mains with the power cord.
If the plug on the exible cord is not the right type for your socket outlets,do not use an adaptor,but remove the
plug from the cord and discard.Carefully prepare the end of the the supply cord and t a suitable plug.
The earth has to be connected!
Do not connect the xture to a dimmer system!
The occupation of the connection-cables is as follows:
Cable (EU) Cable (US) Pin International
Brown Black Live L
Light blue White Neutral N
Yellow/Green Green Earth
4.5 Changing the power supply settings
Both the transformer and the ballast must be connected correctly for the local AC voltage and frequency.
The wrong settings can cause poor performance or demage of the moving head.The factory settings are printed
next to the power switch.
If you want to change the power supply settings,follow the instructions:
1.Disconnect the xture from AC power.
2.Remove the top base covers by loosening the 10 fastening screws.
3.Move the wire 1 on the transformer connection block to the position according to the desired voltage.
4.Move the wires 2 and 3 on the ballast connection block to the position according to the desired frequency
(voltage).
5.Close the base before applying AC power.
Examples:
EU-version:
AC 230V/50Hz
US-version:
AC120V/60Hz
8
Page 9
4.6 Rigging the xture
DANGER TO LIFE!
Please consider the respective national norms during the installation!
The installation must only be carried out by an authorized dealer!
The installation of the projector has to be built and constructed in a way that it can hold 10 times the weight for
1 hour without any harming deformation.
The installation must always be secured with a secondary safety attachment, e.g. an appropriate catch net.
This secondary safety attachment must be constructed in a way that no part of the installation can fall down if
the main attachment fails.
When rigging, derigging or servicing the xture staying in the area below the installation place, on bridges,
under high working places and other endangered areas is forbidden.
The operator has to make sure that safety-relating and machine-technical installations are approved by an expert
before taking into operation for the rst time and after changes before taking into operation another time.
The operator has to make sure that safety-relating and machine-technical installations are approved by an
expert after every four year in the course of an acceptance test.
The operator has to make sure that safety-relating and machine-technical installations are approved by a skilled
person once a year.
The projector should be installed outside areas where persons may walk by or be seated.
IMPORTANT! OVERHEAD RIGGING REQUIRES EXTENSIVE EXPERIENCE, including (but not limited to)
calculating working load limits, installation material being used, and periodic safety inspection of all installation
material and the projector. If you lack these qualications, do not attempt the installation yourself, but instead use
a professional structural rigger. Improper installation can result in bodily injury and.or damage to property.
The projector has to be installed out of the reach of people.
If the projector shall be lowered from the ceiling or high joists, professional trussing systems have to be used.
The projector must never be xed swinging freely in the room.
Caution: Projectors may cause severe injuries when crashing down! If you have doubts concerning the safety
of a possible installation, do NOT install the projector!
Before rigging make sure that the installation area can hold a minimum point load of 10 times the projector’s
weight.
Danger of re !
When installing the device, make sure there is no highly inammable
material (decoration articles, etc.) in a distance of min. 0.5m.
CAUTION!
Use 2 appropriate clamps to rig the xture on the truss.
Follow the instructions mentioned at the bottom of the base.
Make sure that the device is xed properly! Ensure that the
structure (truss)to which you are attaching the xtures is secure.
The projector can be placed directly on the stage oor or rigged in any orientation on a truss without altering
its operation characteristics .
9
Page 10
For overhead use, always install a safety-rope that can hold at least 10 times the weight of the xture. You must
only use safety-ropes with screw-on carabines. Pull the safety-rope through the two apertures on the bottom of
the base and over the trussing system etc. Insert the end in the carabine and tighten the xation screw.
Fixation via the omega holders
1.Bolt each clamp (1) to the omega holder (4) with M12 bolt and lock nut through the hole in the holder.
2.Fasten the omega holders on the bottom of the base by inserting both quick-lock fasteners (3) into the holes
of the base and tighten fully clockwise.
3.Fasten the safety-rope (2) through the two apertures on the bottom of the base and over the trussing system.
1 - Shield
2 - Signal (-)
3 - Signal (+)
4 - Not connected
5 - Not connected
If you are using the standard DMX controllers, you can connect the DMX output of the controller directly with
the DMX input of the rst xture in the DMX-chain. If you wish to connect DMX-controllers with other XLR-outputs, you need to use adapter-cables.
1 - Shield
2 - Signal (-)
3 - Signal (+)
4 - Not connected
5 - Not connected
Controller operation
Master/slave operation
Building a serial DMX-chain:
Connect the DMX-output of the rst xture in the DMX-chain with the DMX-input of the next xture. Always
connect one output with the input of the next xture until all xtures are connected.
Caution: At the last xture, the DMX-cable has to be terminated with a terminator. Solder a 120 Ω resistor
between Signal (–) and Signal (+) into a 3-pin XLR-plug and plug it in the DMX-output of the last xture.
Building a master/slave-chain:
Connect the DMX-output of the master xture in the data-chain with the DMX-input of the rst slave. Always
connect output with the input of the next slave until all slaves are connected (up to 9 xtures).
Caution:It’s necessary to insert the XLR termination plug (with 120 Ohm) into the input of the master xture
and into the output of the last slave xture in the link in order to ensure proper transmission on the data link.
To activate following functions, stop in DMX value for at
least 3 s and shutter must be closed at least 3 s. („Shutter,Strobe” channel 16 (15,18,20) must be at range: 0-31
DMX).**
Pan/Tilt speed mode
Pan/Tilt time mode
Blackout while pan/tilt moving
Disabled blackout while pan/tilt moving
Blackout while colour wheel moving
Disabled blackout while colour wheel moving
Reserved
To activate following functions,
stop in DMX value for at least 3 s.
Lamp On,reset(total reset except pan/tilt reset)
Pan/Tilt reset
Colour system reset
Reserved
Dimmer/Strobe reset
Zoom/effect wheel reset
Reserved
Total reset
Reserved
Lamp Off
Reserved
Pan/Tilt macro selection
Disabled pan/tilt macro
Reserved
Figure of circle (from small to large)
Figure of horizontal eight (from small to large)
Figure of vertical eight (from small to large)
Figure of rectangle (from small to large)
Figure of triangle (from small to large)
Figure of star (from small to large)
Figure of cross (from small to large)
Pan/Tilt macro speed
(Set pan/tilt speed (channel 5) to 0)
No macro generation
Macro generation from fast to slow-forwards
No macro generation
Macro generation from slow to fast-backwards
Macro 23
Macro 24
Macro 25
Macro 26
Macro 27
Macro 28
Macro 29
Macro 30 - Random rainbow effect from fast to slow
Random macro selection by audio control
(Set microphone sensitivity in menu "PErS")
Auto random macro selection from fast to slow
Effect wheel
Full beam
Beam shaper
Swivelling beam effect from slow to fast
Frost lter
Zoom
Coarse zoom from min. to max.beam angleproportional
Shutter, strobe
Shutter closed,
Shutter open,
Strobe-effect from slow to fast (max.15 ashes/s)
Shutter open,
Opening pulse in sequences from slow to fast
Closing pulse in sequences from fast to slow
Shutter open
Random strobe-effect from slow to fast
Shutter open
Dimmer intensity
Dimmer intensity from 0% to 100%
Fine dimmer intensity
Dimmer intensity neproportional
Type of
control
step
step
step
step
step
step
step
proportional
step
proportional
step
proportional
proportional
step
step
step
proportional
step
proportional
proportional
step
proportional
step
proportional
Notes:
* Short times are not used for long tracks (e.g. 0.5s for track 0-255 DMX). Times are restricted by
the mechanical
** The switch-functions have priority to the equivalent functions in menu "Personality"but the setting
by DMX is not saved to the memory( after switching the xture on,the setting from menu "Personal
ity" is loaded and after that can be changed by DMX value on the channel 6).
DMX protocol menu "PerS"
50-59 Pan/Tilt speed mode P.t.Mo.--->SP.Mo.
60-69 Pan/Tilt time mode P.t.Mo.--->ti.Mo.
70-79 Blackout while pan/tilt moving A.blc.-->P.t.M.-->On
80-89 Disabled blackout while pan/tilt moving A.blc.-->P.t.M.-->Off
90-99 Blackout while colour wheel moving A.blc.-->Col.M.-->On
100-109 Disabled blackout while colour wheel moving A.blc.-->Col.M.-->Off
parameters of the xture.
14
Page 15
6. Controller mode
The xtures are individually addressed on a data link and connected to the controller.The xtures respond to
the DMX signal from the controller.
6.1 DMX addressing
The control panel on the front panel of the xture allows you to assign the DMX xture address, which is dened
as the rst channel from which the ColorWash 250 AT will respond to the controller.
If you set, for example, the address to channel 19, the ColorWash 250AT will use the channel 20 to 35 for
control (if mode 1 is selected).
Please, be sure that you don’t have any overlapping channels in order to control each ColorWash 250 AT correctly and independently from any other xture on the DMX data link.
If two, three or more ColorWash 250 AT are addressed similarly, they will work similarly.
For address setting, please refer to the instructions under "Addressing"(menu "A001").
Controlling:
After having addressed all ColorWash 250 AT , you may now start operating these via your lighting controller.
Note:After switching on, the ColorWash 250 AT will automatically detect whether DMX 512 data is received
or not.If there is no data received at the DMX-input, the display will start to ash "A001" with actually set ad-
dress.
This situation can occur if:
- the 3 PIN (5pin) XLR plug (cable with DMX signal from controller) is not connected with the input of the ColorWash 250 AT
- the controller is switched off or defective, the cable or connector is defective or the signal wires are swap in
the input connector.
Note:It’s necessary to insert the XLR termination plug (with 120 Ohm) to the last xture in the link in order to
ensure proper transmission on the DMX data link.
6.2 Remotely controllable functions
Lamp
The ColorWash 250 AT is to be operated with a Philips MSD 250/2 lamp.
A relay inside of the ColorWash 250 AT allows you to switch on and off the lamp via the control panel or via
your DMX-controller without affecting the rest of the lighting.
To switch On/Off the lamp, please refer to "Switching On/Off the lamp" (menu LAMP).
Note:It is also important to note, that the discharge lamp is cold restrike types, that means, that they have to be
cold before re-striking. For this reason, you have to wait 5 minutes (max. speed of fan must be adjusted) after
having switched off the lamp before you switching it on again. If you try to switch On the lamp within 5 minutes
after having switched it off, the ColorWash 250 AT will store this information and automatically ignite the lamp
when the 5 minutes period has expired. The message "HEAt" will appear on the control panel display of the
ColorWash 250 AT. If the ignition of the lamp is seven times unsuccessful, on the display will appear "LA.Er",
meaning that the lamp could be damaged or is missing or there could be a failure on the ignitor or ballast.
Colour wheel
This wheel contains 6 replaceable 'SLOT&LOCK' dichroic lters + open.The colour-wheel can be positioned
between two adjacent colours in any position. It is also possible to rotate the colour wheel continuously at dif-
ferent speeds ("Rainbow effect“ in both directions).
Effect wheel
This wheel contains a frost lter and a rotating indexable beam shaper.
Zoom
Motorized zoom unit provides a beam angle range of 8° through 32° .
Dimmer
Smooth 0 - 100 % dimming is provided by the special dimmer unit.
15
Page 16
Shutter/Strobe
Extremely fast shutter is also used for strobe effect (1 - 10 ashes per second)
7. Stand - alone mode
The xtures on a data link are not connected to the controller but can execute pre-set programs which can be
different for every xture.To set the program to be played,see the "Stand-alone setting" ( menu "St.AL.").
"Stand-alone operation" can be applied to the single xture (the xture may be set to the master /slave mode
or controller mode) or to multiple xtures operating synchronously.
Synchronous operation of multiple xtures requires that they must be connected on a data link and one of them
is set as a master (master mode) and the rest as the slaves (slave mode).The slaves are assigned to SLA1SLA9 and on the certain slave address can be connected only one xture.To set the xture as the master or
slave , see the "Addressing" (menu "A001").Only one xture can be set as the master.
If the master xture runs a reset,switches On/Off the lamp or plays test(program) ,all slaves will execute
these acts too (e.g. if the master xture has switched the lamp off,no slaves can switch the lamp on)!
The master xture starts simultaneous program start in the other slave xtures.All xtures have a denite, synchronized starting point when playing back their programs.The number of running program is the same in all
slaves and depends on the master's choice (menu "St.AL." ).Every xture runs its program repeatedly ,starting
the program step No.1 when requested by the master .
For example:
If the slave xture has a shorter program length, it will continously repeat its program until the master xture
nishes its own program and restarts its program running (slave 1- prog.step 3 will not be nished).
If the slave xture has a longer program length, it will restart at prog. step 1 before it completes all its
prog.steps
(slave 2 - prog.step 5 will not be played)- see the picture bellow.
Restart
Starting point
Note:Disconect the xtures from the DMX controller before master/slave operating ,otherwise data collisions
MAn.C.
Pan (0-255)
:
F.dim (0-255)
tESt
Mod 1
Pan (0-255)
tilt (0-255)
Zoom(0-255)
Go...
Mod 2
St.AL.
Audi.(On,Off)Auto
Off
tESt
PrG.1
PrG.2 PrG.3
PLAY
tESt
PrG.1
PrG.2 PrG.3 Edit
PrG.1
PrG.2 PrG.3 St.01 : St.99 Pan (0-255)
:
S.tim.(0.1-25.5) (s)
COPY
18
Page 19
rESE.
SPEC.
LA.Ad.
PAn (0-255)tilt (0-255)
CodE
rdML
rdMH
AdJ. Pan (0-255):
F.CAL
Colo. (0-255):
dimr (0-255)A.rES.
uPd.M.(No,Yes)
19
Page 20
9. Control menu
The control panel situated on the front panel of the base offers several features. You can simply set the DMX
address,read the number of the lamp or unit hours, switch On and Off the lamp, run test, make a reset and also
use many functions for setting xture behaviour.
Control elements on the control board:
[MODE] button-leaves menu without saving changes.
[ENTER] button- enters menu,conrms adjusted values and leaves menu.
[UP] button and[DOWN] button- moves between menu items on the the same level, sets values.
After switching the xture on,the display shows the initial screen:
Use [UP],[DOWN] to browse through the menu. To select a function or submenu,press [ENTER].
9.1 Fixture Address
Use this menu to set the DMX address of the xture or set the xture as a Master (Slave).
dM.Ad. --- DMX addressing.Select this submenu to set DMX start address.
MA.SL. --- Master/slave addressing.Select this submenu to set the xture as a Master or Slave (Slave1- Slave 9).Option "d.AbL" deactivates master/slave setting.
9.2 Slave control
This function allows you to control the slaves from the master's control panel in a master/slave operation.
Select this function from the main menu and press [ENTER].Browse the list of all connected slaves ("SL.C.1"
- "SL.C.9") by pressing [UP] or [DOWN].Select the desired slave and press [ENTER]-button.The matching slave
control panel is available from the master control panel.
Note:This function is available from the master xture only.
9.3 Fixture informations
Use this menu to read an useful information about the xture.
Po.ti. ---Power on time.Select this submenu to read the number of operation hours.
totL --- The function shows the total number of the operation hours since the ColorWash
250 AT has been fabricated.
rSEt --- The function shows the number of the operation hours that the ColorWash 250 AT has been powered on since the counter was last reset.In order to reset
this counter to 0 you have to hold [UP] and[DOWN ] and press the [ENTER].
La.ti. --- Lamp on time.Select this submenu to read the number of the operation hours with the lamp on.
totL --- The function shows the total number of the operation hours with the lamp on since
the ColorWash 250 AT has been fabricated.
rSEt --- The function shows the number of the operation hours with the lamp on that the
20
Page 21
ColorWash 250 AT has been powered on since the counter was last reset.In order to reset this counter to 0 you have to hold [UP] and[DOWN ] and press the [ENTER].
LA.St. --- Lamp strikes.Select this submenu to read the total number of the lamp strikes.totL --- The function shows the total number of the lamp strikes since the ColorWash
250 AT has been fabricated.
rSEt --- The function shows the number of the lamp strikes since the counter was last reset.In order to reset this counter to 0 you have to hold [UP] and[DOWN ] and press [ENTER].
tEMP ---Fixture temperatures.Select this submenu to read the xture temperatures (°C).Please note that the
outside temperature should not exceed 40° C.
Cur.t. --- Current xture temperatures.
boAr.-Current temperature on the main board in the base of the
xture.Temperatures above 87°C lead to the lamp being switched off
and the xture goes to "low power mode".Before switching the lamp on
again (after 5 minutes),run a total xture reset.
HEAd-Current temperature of the head inside.Temperatures below 82°C
are not critical. 82° C and more lead to the lamp being switched off and the
xture goes to "low power mode".Before switching the lamp on again (after
5 minutes),run a total xture reset.
Hi.tE. --- Maximum xture temperatures.
boAr.- The function shows the max.temperature on the main board since
the ColorWash 250 AT has been fabricated.
HEAd - The function shows the max.temperature of the head inside since
the ColorWash 250 AT has been fabricated.
rSEt --- Maximum resetable temperatures.boAr. - The function shows the maximum temperature on the main board
since the counter was last reset.In order to reset the counter to 0 you have
to hold [UP] and[DOWN ] and press the [ENTER].
HEAd - The function shows the maximum temperature of the head inside
since the counter was last reset.In order to reset the counter to 0 you have
to hold [UP] and[DOWN ] and press the [ENTER].
DM.In.--- Readout of DMX values.Select this function to read DMX values (0-255) of each channel received
by the xture.
PAna coarse pan movement C.SPd. a CMY/dimmer speed F.PAn a ne pan movement Macr. a CMY macro
tilta coarse tilt movement EFFE. an effect wheel F.tilt a ne tilt movement Zoom a zoom
SpEd a pan/tilt speed Stro.a strobe,shutter
P.t.SE. a pan/tilt macro selection dimr a shutter,strobe
P.t.SP. a pan/tilt speed F.dim. a ne dimmerFunc. a special function Colo. a colour wheel F.Col. a ne colour wheel CYAN cyan lamellas MAGE. magenta lemellas YELL. yellow lamellas
VErS. --- Software version.Select this function to read the software version of processors:
IC1.b.--- Main processor on the main board in the xture baseIC2.b.--- Pan processor on the main board in the xture baseIC3.b. --- Tilt procesor on the main board in the xture baseIC4.b.--- EEprom on the main board in the xture baseIC1.L.--- Processor 1 in the left arm of the xtureIC2.L.--- Processor 2 in the left arm of the xtureIC1.r.--- Processor 1 in the right arm of the xture
21
Page 22
9.4 Personality
Use this menu to to modify ColorWash 250 AT operating behavior.
r.PAn --- Pan reverse.Select this function to invert the pan movement.
r.tilt --- Tilt reverse.Select this function to invert the tilt movement.
DM.Pr. --- DMX preseting.Select this function to set desired effects assigning to the channels.Please refer to
the chapter "DMX protocol" for detail description.
LA.Pr. --- Lamp presetting.Select this menu to change the lamp "behaviour".LA.Au. --- Select this function to turn the lamp on automatically after switching the
xture on.
d.L.OF. --- Select this function to switch off the lamp via DMX.
dM.On --- This function allows you to strike the lamp automatically after 26 seconds if DMX
signal is present on the data link.If the ignition is unsuccessfull (e.g.lamp is too hot),the
xture will try to ignite the lamp after next 26 s.This process will repeat until the lamp lights.
dM.OF. --- This function allows you to switch Off the lamp automatically after 2 minutes if
DMX signal is missing on the data link.
LA.dE. --- Lamp ignition delay. This function allows you to set the time delay( 0-90s) before the lamp will be ignited.This setting will not affect starting the lamp direct from the control
panel(menu "Lamp On/Off").
En.Sn. --- Switching on/of the lamp light sensor.Select this function to switch the lamp light sensor on or
off.The option"On" is for the standard operation.
Important: The option"Off" is for "emergency operation" only if the lamp light sensor is defective and you will
wait for a service intervertion! If the lamp light sensor is switched off and at switching the lamp on the electronics
will still try to ignite the lamp until it shines (even when the lamp is damaged or absent), on this account some
electronics parts could be damaged!
DiSP. --- Display adjusting.This function allows you to change the display settings.
turn --- Select this function to turn the display by 180°.
d.On --- This function allows you to keep the display on or to turn off automatically 2 minutes
after last pressing any button on the control panel.
d.Int. --- Select this function to adjust the display intensity (20-min.,100-max.).
bL.Co. --- Blackout during movement correction.Select this function to enable the blackout during the
head movement correction (if the moving head lost its right pan/tilt position for a short moment).
FEEd --- Pan/Tilt feedback.This function allows to return the mowing head to the required pan/tilt position after
changing the position by external force (e.g.by stroke).
Be careful, the Pan/Tilt Feedback OFF is not the standard operation and the head of the xture can
be demaged!
Note: If the feedback was switched off ,the pan/tilt-position is changed by an external force and the feedback
is switched on again,the moving head might not to be synchronized with the DMX signal.You have to make a
reset in order to synchronize the moving head with the DMX signal.
Mi.SE. --- Microphone sensitivity.Select this function to adjust the microphone sensitivity from 1(maximum)
to 20(minimum).If the sensitivity is correctly adjusted,the upper segment of the rst digit blinks in the bass
beat.
Examples:
underexited right level overexited
(upper segment blinks via the bass rhythm)
22
Page 23
Fan.S. --- Fan speed operating modes.By using this function you can choose 2 types of the fan speed operating modes.
Auto --- The fans automatically raise their speed in order to control inside temperature
of the head, if the temperature inside increases about certain level (the low fan speed reduces the cooling of the lighting). This cycle can repeat several times until the temperature
inside is on a suitable level.
HIGH --- The cooling fans work on max. speed (max. cooling).This mode we recommend for high ambient temperature (30 °C and more).
P.t.Mo. --- Pan/tilt movement mode.Use this menu to set the character of the pan/tilt movement.
ti.Mo. ---Time mode.Pan and tilt will move with different speeds and they will come at the
same time to end point (pan and tilt sets its optimal speed).
SP.Mo. ---Speed mode.Pan and tilt will move with the same speed as adjusted by the
channel 5 (Pan/Tilt speed).E.g. pan will come to the end point and wait for tilt,which has longer
track.
A.blc. --- Automatic blackout.Use this function if you wish to close the light output during effect changes.
P.t.M. --- This function closes the light output during pan/tilt changes.
Col.M. --- This function closes the light output during colour wheel changes.
In.Po. --- Init effect positions.Select this function to adjust all effects to the desired initial positions.After switch-
ing the xture on (if DMX is not connected),all effects will move to initial positions. Use the [UP] and [DOWN]
buttons to select desired channel and press [ENTER].Set the effect to the desired position using [UP] and
[DOWN] buttons and conrm by pressing [ENTER].After having adjusted required effects,select "Stor." to save
all initial values to the memory.
dF.SE. --- Default Settings .Select this option to reset all xture personalities to the default values.
9.5 Lamp On/Off
Use this option in order to switch on/off the lamp.It is also important to note, that the lamp is cold restrike type,
that means, that it has to be cold before striking.
9.6 Manual mode
Select this menu to call up presetted positions of channel effects or direct control channel effects.
PrE.C. --- Presetted effect control.Select this menu to call up presetted positions of the channel effects.
Man.C. --- Manual effect control.Select this menu to control effects by control buttoms on the control board.
PAna coarse pan movement C.SPd. a CMY/dimmer speed F.PAn a ne pan movement Macr. a CMY macro
tilta coarse tilt movement EFFE. an effect wheel F.tilt a ne tilt movement Zoom a zoom
SpEd a pan/tilt speed Stro.a strobe,shutter
P.t.SE. a pan/tilt macro selection dimr a shutter,strobe
P.t.SP. a pan/tilt speed F.dim. a ne dimmerFunc. a special function Colo. a colour wheel F.Col. a ne colour wheel CYAN cyan lamellas MAGE. magenta lemellas
YELL. yellow lamellas
23
Page 24
9.7 Test sequences
Use this menu to to run a special demo-test sequences without an external controller, which will show you some
possibilities of using ColorWash 250 AT.
Mod.1 --- Mode 1. This mode is suitable for projections on the wall, ceiling or ground without any head movement.
Mod.2 --- Mode 2.This mode uses all ColorWash 250 AT functions including pan/tilt
movement and therefore is good for a complete introduction of the xture.
9.8 Stand-alone setting
Use this menu to set options for stand-alone mode as a selection of the playing program,programming and
modifying current programs.
Audi --- Music trigger.Select this function to enable the sound control of the running programs via the built-in
microphone.
Auto --- Presetting playback.This function allows you to select the program which will be played in the stand-
alone mode after switching the xture on.Selected program will be played continuously in a loop.
d.Abl --- The option disables "Auto" function.
tESt --- The option will start built-in test program. PrG. 1 --- The option will start created program No.1
PrG. 2 --- The option will start created program No. 2
PrG. 3 --- The option will start created program No. 3
Note:If the xture operates in the controller mode ( DMX controller is connected) and any program from this
menu is selected ,in this case the xture will not respond to the DMX controller after switching on and will play
selected program.
PLAY --- Playing program.Select this menu to run a bilt-in program or the 3 freely-programmable programs
in a loop.
tESt --- The option starts built-in test program. PrG.1 --- The option starts created program No. 1
PrG.2 --- The option starts created program No. 2
PrG.3 ---The option starts created program No. 3
Select the program you wish and press [ENTER].The selected program starts running.By pressing [ENTER]
is possible to pause the program running.
Edit --- Editing program.Select this menu to edit or create the program.The ColorWash 250 AT has one builtin program and the 3 free programs,each up to 99 steps.Each program step has a step time.Step time-the
time,during which effects last in the current step.
If the xture is set as a master ,then you may edit any program in the slaves.You can't edit programs on the
slave xtures from their control panels if the master xture is switched on and connected to the slaves (editing
is possible by the master control panel only).
Procedure:
1. Press [UP] or [DOWN] to select the program you want to edit ("PrG.1" - "PrG.3") and press [ENTER].
2. Press [UP] or [DOWN] to select the desired xture ("MASt." - "SLA.9") and press [ENTER]-button.
3. Press [UP] or [DOWN] to select the desired program step ("St.01" - "St.99") and press [ENTER]-button.
4 Press [UP] or [DOWN] to select the desired item and press [ENTER]-button.Now you can edit by [UP] or
[DOWN] buttons the DMX value (0-255) for selected item:
P.End. - a total number of the program steps (value 1-99).This value you must set before start
programming(e.g. if you want to create program with the 10 steps,set P.End=10).PAn a coarse pan movement
tilt a coarse tilt movemen
SpEd a pan/tilt speed
Func. a special function
P.t.SE. a pan/tilt macro selection
24
Page 25
P.t.SP. a pan/tilt speed
Colo. a colour wheel
CYAN cyan lamellas
MAGE. magenta lemellas
YELL. yellow lamelas
C.SPd. a CMY/dimmer speed
Macr. a CMY macro
EFFE. an effect wheel
Zoom a zoom
Stro. a shutter,strobe
dimr a dimmer S.tim. a step time,value 0,1-25,5 seconds
COPY. - copying the current prog. step to the next prog. step .If the last prog.step is copied to the
next prog. step ,parameter "P.End" is increased about one automatically (except step 99).
5. Press [ENTER]-button to conrm adjusted value .
6. Press [MODE]-button,select next prog. step and repeat this procedure (steps 4 - 6).
9.9 Reset function
This option enables the ColorWash 250 AT to index all effects (functions) and return to their standard positions.
9.10 Special functions
Use this menu for special services like adjusting lamp or adjusting effects.
LA.Ad. --- Lamp adjustment.This function can be used when you make the ne adjustment of the lamp.If you
select this function,all effects will be canceled,shutter will be opened and the dimmer intensity will be set onto
100%.By using the options "PAn, tilt" you can aim the light on a at surface (wall) and perform the ne lamp
adjustment.
CodE --- Code.This function contains identication hexadecimal code (0000-FFFF) for the xture, which is
used for the master/slave operation.
rdML --- Code.This menu item shows the rst part of an RDM identication code.
rdMH --- Code.This menu item shows the second part of an RDM identication code.
AdJ. --- Effect adjustment.By this function you can calibrate and adjust the effects to their standard/right
positions.Disconect the DMX controller from the xture and select "AdJ." menu.The display shows step by step
effects by which you can adjust the xture to the required position before the function calibration(DMX controller
must be disconnected) . When the positioning is nished ,select "F.CAL." and press [ENTER]:
1. Calibration via the control board
Disconnect DMX controller from the xture.Press [ENTER] and use [UP] and [DOWN] in order to display
the following items: "Colo,EFFE,Zoom,dimr" for very smooth function calibration. Select one of them, press
[ENTER] and use the [UP] and [DOWN] in order to adjust their right value from 0 to 255. Then press [ENTER]
to conrm or [MODE] to cancel and return to the menu. This can be repeated for each calibration parameter if
it is required. When the calibration is nished, it is necessary to use the "A.rES" function in order to write the
calibration values to the memory (EPROM) and to make a reset in order to check the newly adjusted positions
of the effects. When the reset of the xture is nished, the display will show the "F.CAL" message. Press
[ENTER] to repeat the calibration or [MODE] to return to the "AdJ." menu.
2. Calibration via the external controller
25
Page 26
Connect the DMX controller to the xture, press [ENTER] and the [UP] and [DOWN] buttons in order to display
the following items: "Colo,EFFE,Zoom,dimr" . Select one of them and press [ENTER].
Now you can calibrate this effect by your controller. The DMX calibration protocol are described below.
After having calibrated required effects, press [ENTER] to conrm (or [MODE] to cancel and return to the menu
without reset by the "A.rES." function) and use the "A.rES." function in order to write the calibration values to
the memory and to make a reset in order to check the new adjusted positions of the effects.
uPd.M. ---Updating mode.Using this function you can update software in the xture via PC and serial link.
The following are required in order to update software:
- PC running Windows 95/98/2000/XP or Linux
- DMX Software Uploader
- Flash cable RS232/DMX (No.13050624)
Note1:Software update should execute a qualied person.If you lack qualication, do not attempt the update
yourself and ask for help your ROBE distributor.
Note 2:DMX address, IP address ,programs 1-3 and all functions in menu "PErS" will be set to their default
values.
To update software in the xture:
1.Installation of DMX Software Uploader.
1.DMX Software Uploader program is available from the ROBE web site at WWW.robe.cz.
2.Make a new directory ( e.g. Robe_Uploader) on your hard disk and download the software to it.
3.Unpack the program from the archive. If the Robe xture is produced in magnetic and electronic ballast version, name of DMX Software Uploader is the same for both versions.
2.Fixture software updating.
1.Determine which of your COM port is available on your PC and connect it with to the DMX input
of the xture using the uploading cable. Do not extend this cable! Disconnect the xture from the
other xtures in DMX chain! Turn on the computer and the xture. Make sure the lamp is
switched off.
2.Switch the xture to the update mode by selecting the option Updating mode in menu Special
Functions on the xture control panel:SPEC-->UPd-->yES.(From this option you cannot return back
to the main menu. If you do not want to continue in software update, you have to switch off and on
the xture to leave this option!)
3.It is recommended that you exit all programs before running the Software Uploader.
4.Start the Software Uploader program. Select desired COM and then click Connect button.
If the conection is OK, click Start Uploading button to start uploading. It will take several minutes to
perform software update. If the option "Incremental Update"isn´t checked ,all processors will be
updated (including processors with the same software version).
If you wish to update only later versions of processors, enable the Incremental Update check box.
Avoid interrupting the process. Update status is being displayed in the list window.
When the update is nished, the line with the text “The xture is successfuly updated‘ will appear in
this window and the xture will reset with the new software.
Note: In the case of interruption of the upload process (e.g. power cut), the xture remains in the update mode
and you have to repeat the software update again.
For example: The xture was switched off before nishing software upload. After switching the xture on again,
the xture is still in the update mode and the display is dark. Restart the Software Uploader program and repeat
software update from your PC.
10. Power down mode
This mode omits xture reset after switching the xture on and lowers motor powers of the xture."Power down
mode" is useful in special casech.g. if the xture is in a ight case and you want to set its DMX address without
taking it out from the case.To enter "Power down mode",press and hold [UP] and [DOWN] and at the same time
switch on the Power switch.The following message appears on the display:"P.d.Mo."
Press [ENTER] to activate "Power down mode" without xture reset.Now you can set features and behaviour
of the xture by using "A001"menu and "Pers." menu.If you want to go to the "normal operation mode",execute
xture reset.
26
Page 27
Note:All motors in "Power down mode" are deactivated and switching on the lamp from the control panel is
blocked.
11. RDM
This xture supports an RDM operation. The RDM (Remote Device Management) is a bi-directional communications protocol for use in DMX512 control systems, it is the new open standard for DMX512 device conguration
and status monitoring.
The RDM protocol allows data packets to be inserted into a DMX512 data stream without adversely affecting
existing non-RDM equipment. By using a special „Start Code,“ and by complying with the timing specications
for DMX512, the RDM protocol allows a console or dedicated RDM controller to send commands to and receive
messages from specic moving lights.
The ROBE DreamBox with an additional ROBE RDM-network software provides the RDM functionality. The
DreamBox supports RDM - new control protocol featuring AutoPatch and Fixture Status Monitoring.
The list of RDM commands for ColorWash 250 AT is the following:
Parameter IDDiscovery command SET commandGET command
DISC_UNIQUE_BRANCH*
DISC_MUTE*
DISC_UN_MUTE*
DEVICE_INFO*
SUPPORTED_PARAMETERS*
SOFTWARE_VERSION_LABEL*
DMX_START_ADDRESS**
IDENTIFY_DEVICE**
DEVICE_MODEL_DESCRIPTION*
MANUFACTURER_LABEL*
DEVICE_LABEL**
SENSOR_DEFINITION*
SENSOR_VALUE*
DISPLAY_INVERT**
DISPLAY_LEVEL**
PAN_INVERT**
TILT_INVERT**
DEVICE_RESET*
DMX_PERSONALITY**
DMX_PERSONALITY_DESCRIPTION*
STATUS_MESSAGES*
STATUS_ID_DESCRIPTION*
LAMP_STATE**
LAMP_ON_MODE
DEVICE_HOURS
LAMP_HOURS
LAMP_STRIKES
1
2
2
2
**
*
*
*
1
...Another options for this command (only for Robe´s xtures):
value PARAMETER_DATA=0x84 - lamp OFF by DMX value on DMX channel
value PARAMETER_DATA=0x88 - lamp OFF if DMX is not present
2
...Commands relative resetable values
27
Page 28
12. Error and information messages
HEAt
This message appears if you try to switch on the lamp within 5 minutes after having switched it off (the lamp is
too hot). The message will appear on the display if the lamp doesn't ignite within 28 seconds. The ColorWash
250 AT will store this information and automatically ignite the lamp when the 5 minutes period has expired.
Caution: The message is disabled if the lamp light sensor (function "En.Sn.") is switched Off (only if the lamp
was turned Off and On within 5 minutes,the message "HEAt" will appear).
LA.Er.
The ignition of the lamp is seven times unsuccessful (the "HEAt" message appeared six times before), and the
display shows "LA.Er", meaning that the lamp could be damaged or even missed, the xture is overheating (this
can occur if the ambient temperature is 40° C or more) or there could be a failure on the ignitor or ballast.
Please place or replace the lamp, check the ambient temperature or contact your dealer if the situation was
not caused by the lamp.
Caution: The message is disabled if the lamp light sensor (function "En.Sn.") is switched Off.
Mb.Er.
This messsage informs you that the main PCB does not communicate correctly with the Control Board.
Co.Er. (color-wheel error)
This messsage will appear after the reset of the xture if the magnetic-indexing circuit malfunctions (sensor
failed or magnet missing) or the stepping-motor is defective (or its driver circuit on the main PCB). The color-
wheel is not located in the default position after the reset.
Ft.Er.
This error message informs you that the xture was overheating (occured if the ambient temperature is 40° C
or more) and that the relay switched off the lamp.
Fr.Er.
This message will appear if the frequency of the main is not standard 50 or 60 Hz.This message can appear as
a result of the interference during the lamp starting (if the lamp or igniter is old) or as a result of the interference
by neighbouring devices. In these cases the message does not affect the xture operating!
Sn.Er.
This message appears if the lamp lighting sensor is failed.
PoEr
This message will appear if the xture was shortly disconnect from the main.
Zo.Er. (zoom error)
This messsage will appear after the reset of the xture if the magnetic-indexing circuit malfunctions (sensor
failed or magnet missing) or the stepping-motor is defective (or its driver circuit on the main PCB). The zoom
unit is not located in the default position after the reset.
EF.Er. (effect-wheel error)
This messsage will appear after the reset of the xture if the magnetic-indexing circuit malfunctions (sensor
failed or magnet missing) or the stepping-motor is defective (or its driver circuit on the main PCB). The effect-
wheel is not located in the default position after the reset.
PA.Er. (Pan-yoke movement error)
This message will appear after the reset of the xture if the yoke’s magnetic-indexing circuits malfunction
(sensors failed or magnet missing) or the stepping motor is defective. (Or its driving IC on the main PCB). The
yoke is not located in the default position after the reset.
ti.Er. (TILT-head movement error)
This message will appear after the reset of the xture if the head’s magnetic-indexing circuit malfunctions
(sensor failed or magnet missing) or the stepping motor is defective. (Or its driving IC on the main PCB). The
head is not located in the default position after the reset.
MA.Er.(Master error)
The message informs you that the xture was addressed as a master and DMX signal is connected to its input.
Disconnect the DMX controller from xture's input and address the xture as the master again.
28
Page 29
t.M.Er.(Temperature measuring error)
The message informs you that the communication betwen the head and the main board in the xture base was
cut off (or the head temperature sensor is defective) and the lamp was automatically switched off.
It is absolutely essential that the xture is kept clean and that dust, dirt and smoke-uid residues must not build
up on or within the xture. Otherwise, the xture‘s light output will be signicantly reduced. Regular cleaning will
not only ensure the maximum light output, but will also allow the xture to function reliably throughout its life.
A soft lint-free cloth moistened with any good glass cleaning uid is recommended, under no circumstances
should alcohol or solvents be used!
DANGER !
Disconnect from the mains before starting any
maintenance work
The front objective lens will require weekly cleaning as smoke-uid tends to building up residues, reducing the
light output very quickly. The cooling fans should be cleaned monthly.
The interior of the xture should be cleaned at least annually using a vacuum-cleaner or an air-jet.
The dichroic colour lters should be cleaned monthly.
There are no serviceable parts inside the device except for the lamp and the fuse.
Please refer to the instructions under "Fitting/Exchanging the lamp".
Maintenance and service operations are only to be carried out by authorized distributors.
Replacing the fuse
Only replace the fuse by a fuse of same type and rating.Before replacing the fuse, unplug mains lead!
Procedure:
1) Unscrew the fuseholder on the rear panel of the base with a tting screwdriver from the housing
(anti - clockwise).
2) Remove the old fuse from the fuseholder.
3) Install the new fuse in the fuseholder.
4) Replace the fuseholder in the housing and x it.