Robe Led Blinder 196 LT User Manual

version 1.3
2
3
3
Table of contents
1. Safety instructions ......................................................................................................... 4
2. Operating determinations.............................................................................................. 4
3.Description of the LedBlinder 196 LT............................................................................ 5
4.Installation........................................................................................................................ 5
4.1.Connection to the mains ............................................................................................5
4.2 DMX-512 connection/connection between xtures ....................................................6
4.3 Rigging the xture ...................................................................................................... 6
5.Led Blinder 196 LT-DMX protocol ,version 1.1.............................................................8
6.Led Blinder 196 LT - Control menu map ..................................................................... 10
7.Control board................................................................................................................. 11
7.1 Addressing the LedBlinder 196 LT .......................................................................... 11
7.2 Program running ......................................................................................................11
7.3 Manual mode ...........................................................................................................12
7.4 Test sequences........................................................................................................ 13
7.5 Stand-alone mode.................................................................................................... 13
7.6 Special functions ......................................................................................................13
8.Technical Specications: ............................................................................................. 15
9.Maintenance................................................................................................................... 16
Led Blinder 196 LT
4
5
CAUTION!
Unplug mains lead before opening the housing!
FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY
BEFORE YOU INITIAL START - UP!
1. Safety instructions
Every person involved with installation and maintenance of this product has to:
- be qualiled
- follow the instructions of this manual
CAUTION! Be careful with your operations. With a high voltage you can suffer a dangerous electric shock when touching the wires inside the unit!
This product has left our premises in absolutely perfect condition. In order to maintain this condition and to ensure a safe operation, it is absolutely necessary for the user to follow the safety instructions and warning notes written in this manual.
Important:
The manufacturer will not accept liability for any resulting damages caused by the non-observance of this manual or any unauthorized modication to the product.
Always ground the unit.
The electric connection, repairs and servicing must be carried out by a qualied employee.
Do not connect this unit to a dimmer pack.
Use a source of AC power that complies with local building and electrical rules.AC power has to have both overload and short circuit protection.
CAUTION!
Avoid looking directly into the LED light beam at close range!
2. Operating determinations
This product was designed for indoor use only.
If the unit has been exposed to drastic temperature uctuation (e.g. after transportation), do not switch it on immediately. The arising condensation water might damage your unit. Leave the unit switched off until it has reached room temperature.
Avoid brute force when installing or operating the unit.
When choosing the installation-spot, please make sure that the unit is not exposed to extreme heat, moisture or dust.
Only operate the unit after having checked that the housing is rmly closed and all screws are tightly fas­tened.
The maximum ambient temperature 40° C must never be exceeded.
Operate the unit only after having familiarized with its functions. Do not permit operation by persons not quali­ed for operating the unit. Most damages are the result of unprofessional operation! Please use the original packaging if the product is to be transported. Please consider that unauthorized modications on the unit are forbidden due to safety reasons!
5
3.Description of the LedBlinder 196 LT
4.Installation
4.1.Connection to the mains
The LedBlinder 196 is equipped with auto-switching power supply that automatically adjusts to any 50/60 Hz AC power source from 100-240 volts. Connect the LedBlinder 196 to the mains with the power cord. If the plug on the exible cord is not the right type for your socket outlets,do not use an adaptor,but remove the plug from the cord and discard.Carefully prepare the end of the the supply cord and t a suitable plug. The earth has to be connected!
Cord plug connections:
Cable (EU) Cable (US) Pin International
Brown Black Live L
Light blue White Neutral N
Yellow/Green Green Earth
1 - Mounting yoke 2 - "T" bar 3 - LED modules
3
1
2
Control board
1 - 5-pin DMX output 2 - 3-pin DMX output 3 - 5-pin DMX input 4 - 3-pin DMX input 5 - LED display 6 - Mode-button 7 - Enter-button 8 - Up-button 9 - Down-button 10 - Fuse holder 11 - Mains input
6
7
4.2 DMX-512 connection/connection between xtures
The xture is equipped with both 3-pin and 5-pin XLR sockets for DMX input and output.The sockets are wired in parallel. Only use a shielded twisted-pair cable designed for RS-485 and 3-pin or 5-pin XLR-plugs and connectors in order to connect the controller with the xture or one xture with another.
DMX - output DMX-input
XLR mounting-sockets (rear view): XLR mounting-plugs (rear view):
If you are using the standard DMX controllers, you can connect the DMX output of the controller directly with the DMX input of the rst xture in the DMX-chain. If you wish to connect DMX-controllers with other XLR-out­puts, you need to use adapter-cables.
Building a serial DMX-chain:
Connect the DMX-output of the rst xture in the DMX-chain with the DMX-input of the next xture. Always connect one output with the input of the next xture until all xtures are connected.
Caution: At the last xture, the DMX-cable has to be terminated with a terminator. Solder a 120 resistor between Signal (–) and Signal (+) into a 3-pin XLR-plug and plug it in the DMX-output of the last xture.
Building a master/slave-chain:
Connect the DMX-output of the master xture in the data-chain with the DMX-input of the rst slave. Always connect output with the input of the next slave until all slaves are connected (up to 9 xtures). Caution:It’s necessary to insert the XLR termination plug (with 120 Ohm) into the input of the master xture and into the output of the last slave xture in the link in order to ensure proper transmission on the data link.
4.3 Rigging the xture
Please consider the respective national norms during the installation!
1 - Shield 2 - Signal (-) 3 - Signal (+) 4 - Not connected 5 - Not connected
1 - Shield 2 - Signal (-) 3 - Signal (+) 4 - Not connected 5 - Not connected
Master/slave operation
Controller operation
Loading...
+ 11 hidden pages