5
6.Specications
Power: 100-120V,220-240V AC,50-60Hz
Heater: 800 W
Fuse: 230V/3.15A, 120V/7A
Output: 3,000 Cu.ft/Min.
Heat Up time: 2 Min. 45 sec.
Tank capacity: 0.8 Liter
Fluid consumption rate: 50ml/min
Weight: 4.0 kg (without liquid)
Dimensions (mm): 315Lx205Wx130H
Remote controller: 3 meter wire remote controller VR-1
7.Performance Notes
When the button on the handle (on the remote control) is depressed,the fog machine will fog until the button is released or the heater
needs to reheat.
The Fog 800 FT will fog continuously for up to 90 seconds followed by a reaheating time of up to 45 seconds.
The Fog 800 FT has a recycling period after long bursts when the machine will shut itself down for a short period in order to heat up
again. During this time, no fog can be produced.
The Fog 800 FT may sputter small amounts of fog occasionally during operation and for a minute or so after being turned off.
8.Maintenance
Do not allow the fog liquid to become contaminated. Always replace the caps on the fog liquid container and the fog machine liquid
tank immediately after lling.
After every 40 hours of continuous operation, it is recommended to run a cleaning solution composed of 80% distilled water and 20%
white vinegar through the system to prevent the accumulation of particulate matter in the heating element. The recommended cleaning
regimen is as follows:
1. Empty all fog liquid from machine. Add cleaning solution to tank. Plug unit in and begin warm up.
2. Run unit in a well-ventilated area until tank is almost empty.Do not allow the pump to run dry.
3. Cleaning is now complete. Rell with fog liquid.Run machine briey to clear any cleaning solution from the pump and heater.
4.Do not operate the fog machine without liquid at any time.
Note: All fog machines are prone to clogging due to the thick consistency of fog liquid and the high temperature at which it vaporizes.
However, a properly maintained fog machine should provide years of reliable use.
Clean with a dry cloth only. Store dry.
Cleaning your fog machine regularly will help reduce costly parts replacement and repair charges.
Storage
When storing,run distilled water (not tap water) through the system as described in the cleaning regimen above.This will help avoid any
particles condensing inside the pump or heater.
Replacing the fuse
Before replacing the fuse, unplug mains lead.Replace the fuse by a fuse of the same type and rating.
Note:
The warranty does not extend to any parts of the Fog 800 FT that have been subject to misuse or accident. Neither does the warranty
cover any Fog 800 FT that has been opened, modied or repaired other than by ROBE or its designated distributor.
The warranty will not apply if procedures described in the Instruction Manual are not followed. It is the user's obligation to clean and
maintain the Fog 800 FT according to these instructions, and to follow acceptable practices for handling electrical devices with heating
elements.