Robe Color Wasf 1200E, Color Wash I200E, 1200E Color Wash, Color Wash 1200E AT User Manual

Page 1
Color
Wash
1200E
AT
USER MANUAL
Version: 5.0
ROBE® Lighting s.r.o. Czech Republic www.robe.cz
Page 2
Page 3
3
Table of contents
1. Unpacking 4
2. Safety instructions
4
3. Operating determinations
5
4. Description of the xture
6
5. Installation
8
5.1 Connection to the mains 8
5.2 Changing the power supply settings 8
5.3 Fitting the lamp 9
5.4 Lamp adjustment 9
5.5 Inserting/Exchanging colours 10
5.6 Changing the front lenses 10
5.7 Installing top hats 11
5.8 Rigging the xture 11
5.9 DMX-512 connection/connection between xtures 13
5.10 Ethernet connection 13
6. DMX Protocol 15
7. Controller mode 1
9
7.1 DMX addressing 19
7.2 Remotely controllable functions 19
8. Control menu map 20
9. Control menu 2
4
9.1 Fixture Address 24
9.2 Fixture informations 24
9.3 Personality 26
9.4 Lamp On/Off 28
9.5 Test sequences 28
9.6 Manual mode 28
9.7 Stand-alone setting 28
9.8 Reset functions 29
9.9 Special functions 29
10. Power down mode 30
11. RDM 3
1
12. Error and information messages
32
13. Technical specications 3
3
14. Maintenance and cleaning 3
7
Color
Wash
1200E
AT
Page 4
4
1. Unpacking
The ColorWash 1200E AT cardboard box included items:
- ColorWash 1200E AT
- Wide-angle lens (1piece)
- User manual (1piece)
- Small paper box with Mounting bracket Omega CL assembled (2 pieces) The small paper box is situated in the top part of the cardboard box.
CAUTION! Keep this device away from rain and moisture! Unplug mains lead before opening the housing!
FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOU INITIAL START - UP!
2. Safety instructions
Every person involved with installation and maintenance of this device have to:
- be qualiled
- follow the instructions of this manual
CAUTION! Be careful with your operations. With a high voltage you can suffer a dangerous electric shock when touching the wires!
This device has left our premises in absolutely perfect condition. In order to maintain this condition and to ensure a safe op­eration, it is absolutely necessary for the user to follow the safety instructions and warning notes written in this manual.
Important:
The manufacturer will not accept liability for any resulting damages caused by the non-observance of this manual or any
unauthorized modication to the device.
Please consider that damages caused by manual modications to the device are not subject to warranty.
Never let the power-cord come into contact with other cables! Handle the power-cord and all connections with the mains with particular caution!
Make sure that the available voltage is not higher than stated on the rear panel.
Always plug in the power plug least. Make sure that the power-switch is set to off-position before you connect the device to the mains. The power-plug has to be accessable after installing the device.
Make sure that the power-cord is never crimped or damaged by sharp edges. Check the device and the power-cord from time to time.
Always disconnect from the mains, when the device is not in use or before cleaning it. Only handle the power-cord by the plug. Never pull out the plug by tugging the power-cord.
This device falls under protection class I. Therefore it is essential to connect the yellow/green conductor to earth.
Page 5
5
The electric connection, repairs and servicing must be carried out by a qualied employee.
Do not connect this device to a dimmer pack.
Do not switch the xture on and off in short intervals as this would reduce the lamp’s life.
During the initial start-up some smoke or smell may arise. This is a normal process and does not necessarily mean that the device is defective.
Do not touch the device’s housing bare hands during its operation (housing becomes hot)!
For replacement use lamps and fuses of same type and rating only.
CAUTION ! Avoid looking directly into the light source EYEDAMAGES ! (meant especially for epileptics) !
3. Operating determinations
This device is a moving-head spot for creating decorative effects and was designed for indoor use only.
If the device has been exposed to drastic temperature uctuation (e.g. after transportation), do not switch it on immedi­ately. The arising condensation water might damage your device. Leave the device switched off until it has reached room temperature.
Never run the device without lamp!
Do not shake the device. Avoid brute force when installing or operating the device.
Never lift the xture by holding it at the projector-head, as the mechanics may be damaged. Always hold the xture at the
transport handles.
When choosing the installation-spot, please make sure that the device is not exposed to extreme heat, moisture or dust. There should not be any cables lying around. You endanger your own and the safety of others!
The minimum distance between light-output and the illuminated surface must be more than 4 meters.
Make sure that the area below the installation place is blocked Always x the xture with an appropriate safety rope. Fix
the safety rope at the correct holes only.
Only operate the xture after having checked that the housing is rmly closed and all screws are tightly fastened.
The lamp must never be ignited if the objective-lens or any housing-cover is open, as discharge lamps may explose and
emit a high ultraviolet radiation, which may cause burns.
The maximum ambient temperature 40° C must never be exceeded. Otherwise, the lamp is switched off and the xture
is out of operation for 5
minutes.
CAUTION! The lens has to be replaced when it is obviously damaged,
so that its function is impaired, e. g. due to cracks or deep scratches!
Operate the device only after having familiarized with its functions. Do not permit operation by persons not qualied for
operating the device. Most damages are the result of unprofessional operation!
CAUTION! The lamp has to be replaced when it is damaged or deformed due to the heat!
Please use the original packaging if the device is to be transported.
Please consider that unauthorized modications on the device are forbidden due to safety reasons!
If this device will be operated in any way different to the one described in this manual, the product may suffer damages and the guarantee becomes void. Furthermore, any other operation may lead to dangers like short-circuit, burns, electric shock, burns due to ultraviolet radiation, lamp explosion, crash etc.
CAUTION! The head and yoke must be unlocked before operation! Check the pan/tilt locks!
Page 6
6
4. Description of the xture
The head can be locked for transportation- the tilt lock button (5) is pushed and the pan lock/unlock lever (2) is in lock position. To unlock the head, press the tilt unlock button (6) and move the pan lock/unlock lever (2) to unlock position.
1 - Yoke 2 - Pan lock/unlock lever 3 - Front panel 4 - Moving head 5 - Tilt lock button (red) 6 - Tilt unlock button (green) 7 - Handle 8 - Base
Rear panel of the base 1 - Neutral fuse holder 2 - Live fuse holder 3 - Power cord 4 - Power switch 5 - 5-pin DMX output 6 - 5-pin DMX input 7 - 3-pin DMX output 8 - 3-pin DMX input 9 - Ethernet input
Front panel of the base
1 - Network indicator 2 - Display
3 - Infra-red sensor 4 - Data-transfer indicator 5 - RNS encoder wheel 6 - Escape button 7 - Enter button
Page 7
7
Head inside-top side 1 - Igniter 2 - Colour wheel 1 3 - CMY/conver.lter module 4 - Colour wheel 2 5 - Lamp chamber
Head inside-bottom side 6 - Inside Fresnel lens 7 - Termostat 8 - Lamp cover
Page 8
8
5. Installation
Fixtures must be installed by a Qualied electrician in accordance with all
national and local electrical and construction codes and regulation.
5.1 Connection to the mains
Verify the power supply settings before applying power!
The factory settings are printed next to the power switch. If you wish to change the power supply settings, see the next chapter. Installl a 3-prong grounding-type plug on the power cable (US version). The earth has to be connected!
If you have any doubts about proper installation, consult a qualied electrician.
The occupation of the connection-cables is as follows:
Cable (EU) Cable (US) Pin International
Brown Black Live L
Liht blue White Neutral N
Yellow/Green Green Earth
5.2 Changing the power supply settings
Electronic ballast
The operating range of the electronic ballast is 95 VAC-255 VAC. The transformer has to be set to the local AC voltage.
If you want to change the power supply settings, follow the instructions:
1. Disconnect the xture from AC power.
2. Remove the both top base covers by loosening the 14 screws.
3. Move the wire (3) on the transformer connec­tion block to the position according to the desired voltage.
4. Close the base before applying AC power.
Transformer connection:
Power supply settins: 120V/60Hz
Page 9
9
5.3 Fitting the lamp
DANGER ! Install the lamps with the device switched off only. Unplug from mains before !
To insert the lamp (MSR 1200 SA):
1. Disconnect the xture from power and allow it to cool.
2. Loosen the 2 quarter-turn fasteners marked „X, Y,” on the lamp cover at the back of the head.
3. Gently pull the lamp cover with lamp holder out of
the head.
4. Holding the lamp by its ceramic base, carefully pull
the lamp straight out of the lamp socket.
5. Holding the new lamp by its ceramics base, gently
insert the lamp to the lamp socket. Make sure that the lamp is installed tightly into the lamp socket. Do not install a lamp with a higher wattage! A lamp like this generates temperatures the device is not designed for. Damages caused by non-observance are not sub-
ject to warranty. Please follow the lamp manufacturer‘s
notes! Do not touch the glass bulb bare hand during the installation!
6. Reinsert the lamp cover with the lamp holder and
installed lamp back to the head and tighten the 2 quarter-turn
fasteners again. Warning:if you feel any resistance during this action , check the lamp electrode position and use „A,B,C“
screws to adjust right lamp position.Never put the lamp
in by force otherwise you will bend the lamp
electrode by the adge of the reector! (See picture
bellow)
7. Align the new lamp.
8. Reset „Lamp On Time” and „Lamp Strikes” counters in „Fixture information” menu.
Do not operate this xture with opened housing-cover!
5.4 Lamp adjustment
The lamp holder is aligned at the factory.
Due to differences between lamps, ne adjustment may improve light performance:
1. Switch on the xture and after reset turn on the lamp.
2. Cancel all effects, open the shutter and focus the light on a
at surface (wall) using either DMX controller or function “Lamp adjustment” in “Special functions menu”.
3. Center the hot-spot (the brightest part of the beam) using the
3 adjustment screws „A, B, C”. Turn one screw at a time to drag the hot-spot, diagonally across the projected image. If you cannot detect a hot -spot, adjust the lamp until the light
is even. To reduce a hot-spot, pull the lamp in by turning all three screws „A, B, C” clockwise 1/4-turn at a time until the light is evenly distributed. If the light is brighter around the edge than it is in the center,
or if light output is low, the lamp is too far back in the reector.
„Push” the lamp out by turning the screws „A, B, C” counter­clockwise 1/4-turn at a time until the light is bright and evenly distributed.
1 - Lamp 2 - Lamp holder 3 - 2 quarter-turn fasteners 4 - Lamp cover
3 adjustment scews „A, B, C”
Reector
Lamp electrode-check its position before insertion
to the reector
Page 10
10
5.5 Inserting/Exchanging colours
DANGER!
Install the colours with the device switched off only.
Unplug from mains before!
Turn off the lamp and allow it to cool for at least 10 minutes. Disconnect the xture from power.
Open the bottom cover of the moving head by loosening the 4 quarter-turn fasteners on the top cover and follow the instructions below:
1. Gently bend out the colour module to release it from the xative holes and eject it from the pressing snap.
2. Put the new colour module back under the pressing
snap and push it to the 3 xative notches.
5.6 Changing the front lenses
The ColorWash 1200E AT is supplied with the 2 types of the front lenses (Fresnel lens,wide-angle lens) and the Fresnel lens is installed as standard.
Switch the device off before changing the lens.Be careful.Front lens is very heavy!
If you want to change the front lens,follow the instructions:
1.Remove the front lens using a athead screwdriver to unlock the four quarter-turn screws.
2.Unscrew the safety cabel from the lens
3.Screw up the safety cable to the desired lens.
4.Place this lens and x it by locking the four quarter-turn screws.
Quarter-turn screws
Quarter-turn screws
Nut
Bolt
Safety cable
Page 11
11
5.7 Installing top hats
The ColorWash 1200E AT can be tted with various types of the top hats-see chapter "Technical specications".If you
wish to install a top hat (optional),follow the instructions:
Switch the device off before installing the top hat!
Installing the top hat on the front lens-holder of the xture:
1.Loosen 4 lens holder quarter-turn screws and hook both securing springs to the plastic projections in the front lens-holder.
Tighten the 4 lens holder quarter-turn screws again.
2.Put desired top hat onto a front lens-holder and fasten it by two fastening screws.
3.Snap both springs to the slots in the top hat.
5.8 Rigging the xture
DANGER TO LIFE! Please consider the respective national norms during the installation!
The installation of the xture has to be built and constructed in a way that it can hold 10 times the weight for 1 hour without
any harming deformation.
The installation must always be secured with a secondary safety attachment, e.g. an appropriate catch net. This secondary safety attachment must be constructed in a way that no part of the installation can fall down if the main attachment fails.
When rigging, derigging or servicing the xture staying in the area below the installation place, on bridges, under high
working places and other endangered areas is forbidden.
The operator has to make sure that safety-relating and machine-technical installations are approved by an expert before
taking into operation for the rst time and after changes before taking into operation another time.
The operator has to make sure that safety-relating and machine-technical installations are approved by an expert after every four year in the course of an acceptance test.
The operator has to make sure that safety-relating and machine-technical installations are approved by a skilled person once a year.
Allow the xture to cool for ten minutes before handling. The projector should be installed outside areas where persons may walk by or be seated.
IMPORTANT! OVERHEAD RIGGING REQUIRES EXTENSIVE EXPERIENCE, including calculating working load limits,
installation material being used, and periodic safety inspection of all installation material and the projector. If you lack these
Slot
Securing spring
Plastic projection
Securing spring
Top hat
Fastening screw
Fastening screw
Lens-holder
Page 12
12
qualications, do not attempt the installation yourself, but instead use a professional structural rigger. Improper installation can result in bodily injury and or damage to property. The xture has to be installed out of the reach of people. If the xture shall be lowered from the ceiling or high joists, professional trussing systems have to be used. The xture must never be xed swinging freely in the room.
Caution: Fixtures may cause severe injuries when crashing down! If you have doubts concerning the safety of a possible installation, do not install the xture! Before rigging make sure that the installation area can hold a minimum point load of 10 times the xture’s weight.
Danger of re! When installing the device, make sure there is no highly inamma-
ble material (decoration articles, etc.) in between a distance of min. 1.2 m.
CAUTION! Use 2 appropriate clamps to rig the xture on the truss.
Follow the instructions mentioned at the bottom of the base.
Make sure that the device is xed properly!
Ensure that the structure (truss)
to which you are attaching the xtures is secure.
The moving-head can be placed directly on the stage oor or rigged in any orientation on a truss without altering its ope­ration characteristics . The Omega holders can be placed in 4 positions on the bottom of the base. Use the clamps (not included in delivery) with screws M12.
For overhead use, always install a safety-rope that can hold at least 10 times the weight of the xture. You must only use
safety ropes with screw-on carabines. Pull the safety rope through the two apertures on the bottom of the base and over
the trussing system etc. Insert the end in the carabine and tighten the xation screw.
Fixation via the omega holders
1. Bolt each clamp (1) to the omega holder (4) with M12 bolt and lock nut through the hole in the holder.
2. Fasten the omega holders on the
bottom of the base by inserting both quick-l ock fastener s (3) into the holes of the base and tighten fully clockwise.
3
. Fasten the safety-rope (2) through the
two apertures on the bottom of the base and over the trussing system.
1 - Clamp 2 - Safety-rope 3 - Quick-lock fastener 4 - Omega holder
Possible omega holder 4 positions (dimensions in mm):
When installing xtures side-by-side, avoid illuminating one xture with another!
DANGER TO LIFE! Before taking into operation for the rst time,
the installation has to be approved by an expert!
Page 13
13
5.9 DMX-512 connection/connection between xtures
The xture is equipped with both 3-pin and 5-pin XLR sockets for DMX input and output.The sockets are wired in parallel.
Only use a shielded twisted-pair cable designed for RS-485 and 3-pin or 5-pin XLR-plugs and connectors in order to
connect the controller with the xture or one xture with another.
Occupation of the XLR-connection:
DMX - output DMX-input
XLR mounting-sockets (rear view): XLR mounting-plugs (rear view):
If you are using the standard DMX controllers, you can connect the DMX output of the controller directly with the DMX
input of the rst xture in the DMX chain. If you wishhht to connect DMX controllers with other XLR outputs, you need to
use adapter-cables.
Building a serial DMX chain:
Connect the DMX output of the rst xture in the DMX chain with the DMX input of the next xture. Always connect one output with the input of the next xture until all xtures are connected.
Caution: At the last xture, the DMX cable has to be terminated with a terminator. Solder a 120 Ω resistor between Signal (–) and Signal (+) into a XLR plug and plug it in the DMX output of the last xture.
5.10 Ethernet connection
The xtures on a data link are connected to the Ethernet with Art-Net communication protocol. The controlling software
from PC (or lighting console) has to support Art-Net protocol. Art-Net communication protocol is a 10 Base T Ethernet protocol based on the TCP/IP. Its purpose is to allow transfer of large amounts of DMX 512 data over a wide area using standard network technology.
IP address is the Internet protocol address. The IP uniquely identies any node (xture) on a network.
The Universe is a single DMX 512 frame of 512 channels.
The ColorWash 1200E AT is equipped with 8-pin RJ- 45 socket for Ethernet input.Use a network cable category 5 (with
four „twisted” wire pairs) and standard RJ-45 plugs in order to connect the xture to the network.
RJ-45 socket (front view):
1- TD+ 5- Not connected 2- TD- 6- RX- 3- RX+ 7- Not connected 4- Not connected 8- Not connected
Patch cables that connect xtures to the hubs or
LAN sockets are wired 1:1, that is, pins with the same numbers are connected together:
1 - Shield 2 - Signal (-)
3 - Signal (+) 4 - Not connected 5 - Not connected
If only the xture and the computer are to be inter­connected, no hubs or other active components are needed. A cross-cable has to be used:
pin 1 2 3 4 5 6 7 8 pin 3 6 1 8 7 2 5 4
pin 1 2 3 4 5 6 7 8 pin 1 2 3 4 5 6 7 8
Page 14
14
Ethernet connection
Connect the Ethernet-inputs of all xtures in the xture chain with the network. Option “Ethernet” has to be selected from „Set Ethernet Mode” menu on the xture.
Set IP address (002.xxx.xxx.xxx / 010.xxx.xxx.xxx) and the Universe.
Example:
(DMX address=49) IP addres=002.168.002.003 Universe=1
An advised PC setting: IP address: 002.xxx.xxx.xxx / 010.xxx.xxx.xxx (Different from xture IP addresses)
NET mask: 255.0.0.0
Ethernet / DMX connection
Options „Ethernet/DMX” has to be selected from „Set Ethernet Mode” menu on the rst xture (connected to the network) in the xture chain, next xtures have standard DMX addresses. Connect the Ethernet-input of the rst xture in the data chain with the network. Connect the DMX output of this xture with the input of the next xture until all xtures are connected to the DMX chain.
Caution: At the last xture, the DMX chain has to be terminated with a terminator. Solder a 120 Ω resistor between Signal (–) and Signal (+) into a XLR-plug and connect it in the DMX-output of the last xture.
Example:
(DMX address=1) IP addres=002.168.002.001 Universe=1
(DMX address=25) IP addres=002.168.002.002 Universe=1
DMX address=73
IP address=002.168.002.002 Universe=0
DMX address=25
DMX address=217
DMX address=25
DMX address=1
DMX address=1
IP address=002.168.002.003 Universe=1
Page 15
15
6.DMX Protocol
Mode/Channel
Value Function
Type of
control
1 2 3 4 5
1 1 1 1 16 0 - 255
Pan
Pan movement by 530°
proportional
2 2 2 2 17 0 - 255
Pan Fine
Fine control of pan movement
proportional
3 3 3 3 18 0 - 255
Tilt
Tilt movement by 280°
proportional
4 4 4 4 19 0 - 255
Tilt ne
Fine control of tilt movement
proportional
5 5 5 5 20
0
1 - 255
1 - 255
Pan/Tilt speed , Pan/Tilt time
Max. speed (tracking mode)*
P./T. speed-set Speed Mode in menu: Pan/Tilt Mode
Speed from max. to min. (vector mode)**
P./T. time - set Time Mode in menu: Pan/Tilt Mode
Time from 0,1 s to 25,5 s.
***
step
proportional
proportional
6 6 6 6 21
0 - 49
50 - 59 60 - 69 70 - 79 80 - 89
90 - 99 100 - 109 110 - 129
130 - 139 140 - 149 150 - 159 160 - 169 170 - 179 180 - 199 200 - 209 210 - 229 230 - 239 240 - 255
Power/Special functions
Reserved
To activate following functions, stop in DMX value for at least 3 s and shutter must be closed at least 3 s. („Shutter,Strobe” channel 16 (21,23,28,1) must be at range: 0-31 DMX).****
Pan/Tilt speed mode Pan/Tilt time mode Blackout wh ile pan/tilt moving Disabled blackout while pan/tilt moving Blackout while colour wheels moving Disabled blackout while colour wheels moving Reserved
To activate following functions, stop in DMX value for at least 3 s.
Lamp On,reset(total reset except pan/tilt reset) Pan/Tilt reset Colour system reset Zoom/Fresnel reset Dimmer/Strobe reset Reserved Total reset Reserved Lamp Off Reserved
step
step step step step step step step
step step step step step step step step step step
Notes: * Range 0-255 DMX at max.speed (0 DMX): pan=4.5 s tilt=2.6 s ** Range 0-255 DMX at min. speed (255 DMX): pan=37min.10 s tilt=19 min.34 s *** Short times are not used for long tracks (e.g. 0.5s for track 0-255 DMX). Times are restricted by mechanical
parameters of the xture.
**** The switch-functions have priority to the equivalent functions in menu „Personality” but the setting by DMX
is not saved to the memory (after switching the xture on,the setting from menu „Personality” is loaded and
after that can by changed with DMX value on the channel 6). DMX protocol menu „Personality”
50 - 59 Pan/Tilt speed mode Pan/Tilt mode--->Speed Mode 60 - 69 Pan/Tilt time mode Pan/Tilt mode--->Time Mode 70 - 79 Blackout while pan/tilt moving Active blackout While-->Pan/Tilt Moving-->On 80 - 89 Disabled blackout while pan/tilt moving Active blackout While-->Pan/Tilt Moving-->Off 90 - 99 Blackout while colour wheels moving Active blackout While-->Colour Wheels Moving-->On 100 - 109 Disabled blackout while colour wheel moving Active blackout While-->Colour Wheels Moving-->Off
Page 16
16
Mode/Channel
Value Function
Type of
control
1 2 3 4 5
7 7
0 - 9 10 - 31 32 - 63 64 - 95
96 - 127 128 - 159 160 - 191 192 - 223 224 - 255
Pan/Tilt macro selection
Disabled pan/tilt macro Reserved Figure of circle (from small to large) Figure of horizontal eight (from small to large) Figure of vertical eight (from small to large) Figure of rectangle (from small to large) Figure of triangle (from small to large) Figure of star (from small to large) Figure of cross (from small to large)
step
step proportional proportional proportional proportional proportional proportional proportional
8 8
0
1 - 127 128 - 129 130 - 255
Pan/Tilt macro speed
No macro generation Macro generation from fast to slow-forwards No macro generation Macro generation from slow to fast-backwards
step
proportional
step
proportional
7 7 9 9 7
0 18 37 55 73 91
110 128 - 129 130 - 139 140 - 149 150 - 159 160 - 169 170 - 179 180 - 189 190 - 215 216 - 217 218 - 243 244 - 249
250 - 255
Colour wheel 1
Open/white Deep red Deep blue Green Orange
6000 K temperature lter UV lter
White Deep red Deep blue Green Orange
6000 K temperature lter UV lter
Forwards rainbow effect from fast to slow No rotation Backwards rainbow effect from slow to fast Random colour selection by audio control (Set microphone sensitivity in menu „Personality”) Auto random colour selection from fast to slow
proportional proportional proportional proportional proportional proportional proportional proportional
step step step step step step
proportional
step
proportional
step
proportional
8 10
0 - 255
Colour wheel 1- ne positioning
Fine positioning proportional
8 9 10 11 8
0 18 37 55 73 91
110 128 - 129 130 - 139 140 - 149 150 - 159 160 - 169 170 - 179 180 - 189 190 - 215 216 - 217 218 - 243 244 - 249
250 - 255
Colour wheel 2
Open/white Red ring Blue dot Yellow ring Blue/red Green/orange Yellow/blue/orange/magenta White Red ring Blue dot Yellow ring Blue/red Green/orange Yellow/blue/orange/magenta Forwards rainbow effect from fast to slow No rotation Backwards rainbow effect from slow to fast Random colour selection by audio control (Set microphone sensitivity in menu „Personality”) Auto random colour selection from fast to slow
proportional proportional proportional proportional proportional proportional proportional proportional
step step step step step step
proportional
step
proportional
step
proportional
10 12
0 - 255
Colour wheel 2- ne positioning
Fine positioning proportional
9 11 11 13 3
0 - 255
Cyan
Cyan (0-white, 255-full cyan) proportional
10 12 12 14 4
0 - 255
Magenta
Magenta (0-white, 255-full magenta) proportional
Page 17
17
Mode/Channel
Value Function
Type of
control
1 2 3 4 5
11 13 13 15 5
0 - 255
Yellow
Yellow (0-white, 255-full yellow)
proportional
12 14 14 16 6
0 - 255
Conversion temperature lter 3200K
(0-5600K, 255-3200K) proportional
15 17
0 - 3 4 - 7
8 - 11 12 - 15 16 - 19 20 - 23 24 - 27 28 - 31 32 - 35 36 - 39 40 - 43 44 - 47 48 - 51 52 - 55 56 - 59 60 - 63 64 - 67 68 - 71 72 - 75 76 - 79 80 - 83 84 - 87 88 - 91 92 - 95 96 - 99
100 - 103 104 - 107 108 - 111 112 - 115 116 - 119 120 - 123 124 - 127 128 - 131 132 - 135 136 - 139 140 - 143 144 - 147 148 - 151 152 - 155 156 - 159 160 - 163 164 - 167 168 - 171 172 - 175 176 - 179 180 - 183 184 - 187 188 - 191 192 - 195 196 - 199 200 - 203 204 - 207
208 - 211 212 - 215 216 - 219 220 - 223 224 - 227 228 - 231 232 - 235 236 - 239
CMY Colour macros
No function Macro 1 Macro 2 Macro 3 Macro 4 Macro 5 Macro 6 Macro 7 Macro 8 Macro 9 Macro 10 Macro 11 Macro 12 Macro 13 Macro 14 Macro 15 Macro 16 Macro 17 Macro 18 Macro 19 Macro 20 Macro 21 Macro 22 Macro 23 Macro 24 Macro 25 Macro 26 Macro 27 Macro 28 Macro 29 Macro 30 Macro 31 Macro 32 Macro 33 Macro 34 Macro 35 Macro 36 Macro 37 Macro 38 Macro 39 Macro 40 Macro 41 Macro 42 Macro 43 Macro 44 Macro 45 Macro 46 Macro 47 Macro 48 Macro 49 Macro 50 Macro 51 Macro 52 Macro 53 Macro 54 Macro 55 Macro 56 Macro 57 Macro 58 Macro 59
step step step step step step step step step step step step step step step step step step step step step step step step step step step step step step step step step step step step step step step step step step step step step step step step step step step step step step step step step step step step
Page 18
18
Mode/Channel
Value Function
Type of
control
1 2 3 4 5
15 17
240 - 243 244 - 247 248 - 251 252 - 255
Macro 60 Macro 61 Macro 62 Macro 63
step step step step
13 16 15 18
0 -255
Effect speed
From max. speed to min.speed ***** proportional
17 19
0 - 31 32 - 63 64 - 95
96 - 255
Effect speed assigning
Dimmer + CMY lters + correction lter
Dimmer
CMY lters + correction lter
No function
step step step step
16 20 10
0 - 255
Barn door 1-Upper
From open to close proportional
17 21 11
0 - 255
Barn door 2-Lower
From open to close proportional
18 22 12
0 - 255
Barn door 3-Left
From open to close proportional
19 23 13
0 - 255
Barn door 4-Right
From open to close proportional
20 24 14
0 - 255
Barn doors rotation
From right to left propotional
14 18 21 25
0-85 86 87-171 172-213 214-255
Fresnels opening
LightMax mode provides a high intensity spot (85DMX)
Internal Fresnels opening(from closed to open-LightMax mode) Left Fresnel closed,right Fresnel open Left Fresnel opening,right Fresnel closing Both Fresnels ramping (parallel) from slow to fast Both Fresnels ramping (alternately) from fast to slow
proportional step proportional proportional proportional
15 19 22 26 9
0-255
Zoom
Zoom from min. to max. proportional
20 27
0-255
Zoom ne
Fine zoom positioning. proportional
16 21 23 28 1
0 - 31 32 - 63 64 - 95
96 - 127 128 - 143 144 - 159 160 - 191
192 - 223 224 - 255
Shutter, strobe
Shutter closed, Lamp power reduced efter 10 s to 700W Shutter open,Full lamp power
Strobe-effect from slow to fast (max.15 ashes/s)
Shutter open,Lamp power reduced to 700W Opening pulse in sequences from slow to fast Closing pulse in sequences from fast to slow Shutter open,Electronic strobing “ZAP“ from slow to fast (from 7 to 33
ashes/s) Random strobe-effect from slow to fast Shutter open,Full lamp power
step step
proportional
step proportional proportional proportional
proportional
step
17 22 24 29 2
0-255
Dimmer intensity
Dimmer intensity from 0% to 100% (In range 0-3 DMX, lamp power reduced to 700 W)
proportional
23 30
0-255
Dimmer intensity ne
Fine dimming
proportional
15
No function
***** Range 0-255 DMX at min. speed (0 DMX): Cyan (magenta/yellow,cor. lter) = 1min 10 s
Page 19
19
7. Controller mode
The xtures are individually addressed on a data link and connected to the controller. The xtures respond to the DMX
signal from the controller.
7.1 DMX addressing
There are 512 available channels on DMX link. Every xture on DMX link must have a DMX start address, which is dened as the rst channel from which the xture will respond to the controller.
If you set, for example, for the ColorWash 1200E AT the start address to channel 25, the ColorWash 1200E AT will use the channels 25 to 48 for control (if Mode 3 is selected from „DMX Preseting” menu).
Please, be sure that you don’t have any overlapping channels in order to control each ColorWash 1200E AT correctly and independently from any other xture on the DMX data link.
If two, three or more ColorWash 1200E AT are addressed similarly, they will work similarly.
Controlling:
After having addressed all ColorWash 1200E AT , you may now start operating these via your lighting controller.
Note:
After switching on, the ColorWash 1200E AT will automatically detect whether DMX 512 data is received or not. If there
is no data received at the DMX-input, the display will start to ash with actually address.
This situation can occur if:
-
the 3(or 5) pin XLR plug (cable with DMX signal from the controller) is not connected with the input of the ColorWash 1200E
AT
- the controller is switched off or defective, the cable or connector is defective or the signal wires are swap in the input connector.
7.2 Remotely controllable functions
Lamp
The ColorWash 1200E AT is to be operated with a Philips MSR 1200E SA lamp. A relay inside of the ColorWash 1200E AT allows you to switch on and off the lamp via the control panel or via your DMX­controller without affecting the rest of the lighting. Note: It is also important to note, that the discharge lamp is cold restrike types, that means, that they have to be cold
before re-striking. For this reason, you have to wait at least 5 minutes after having switched off the lamp before you can switch it back on again. If you try to switch On the lamp within 5 minutes after having switched it Off, the ColorWash 1200E AT will store this information and automatically ignite the lamp when the 5 minutes period has expired.
CMY-colours mixing system
The CMY color mixing system is based on graduated cyan, magenta, and yellow color lters. A continuous range of colors may be achieved by varying the amount of each lter from 0 to 100%. Colour temperature correction ltre lowers the colour temperature from 5600K to 3200 K.
Colour wheel 1
The ColorWash 1200E AT features a colour wheel 1 with 4 colour positions, UV lter and 6000 K temp. lter and the
hole (open). It is also possible to rotate the colour wheel continuously at different speeds, the so-called „Rainbow effect“ is created. Auto random colour selection,random colour selection by audio control is possible.
Colour wheel 2
The ColorWash 1200E AT included a colour wheel 2 with 6 colour positions and the hole (open). It is also possible to rotate the colour wheel continuously at different speeds, the so-called „Rainbow effect“ is created. Auto random colour selection,random colour selection by audio control is possible.
Zoom
Motorized zoom,zoom range depends on the front lens.Open internal Fresnel lens (LightMax mode) provides a high intensity spot (channel “Fresnel opening“ is set at 85 DMX).
Fresnel lens Beam angle
LightMax mode 10° Minimum zoom 13° Maximum zoom 44°
Wide-angle lens Beam angle
LightMax mode 68° Minimum zoom 75° Maximum zoom 87°
Dimmer/Shutter/Strobe
Smooth 0 - 100 % dimming is provided by the combined mechanical dimmer/shutter unit. This unit may also be used for strobe effect.
Page 20
20
8. Control menu map
Note: Default settings = Bold print
Fixture Address
DMX Address 001 : 512 Ethernet Settings Set Ethernet Mode Disable Ethernet Ethernet Ethernet/DMX Set IP Address Default IP Address Custom IP Address Set ArtNet Universe (0 -255)
Fixture information
Power On Time Total Hours Resetable Hours Lamp On Time Total Hours Resetable Hours Lamp Strikes Total Hours Resetable Hours Air lters
Set Alert period (10...50....300 hours)
Elapsed time [hours]
Fixture Temperatures Current Board Temp. [°C] Ambient Temp. [°C] Near Lamp Temp. [°C] Maximum Nonresetable Board Temp. [°C] Ambient Temp. [°C] Near Lamp Temp. [°C] Maximum Resetable Board Temp. [°C] Ambient Temp. [°C] Near Lamp Temp. [°C] Fans Speed Fan 1 : Fan 9 DMX Values Pan (0-255) : Dimmer Fine (0-255) Software Version IC1 MB IC2 MB : IC2 DS Product IDs Mac Adr. RDM UID
Personality
User Mode User A Settings User B Settings User C Settings
Page 21
21
DMX Presetting Mode 1 Ch.1 Pan : Ch. 17 Dimmer Set Active Mode 2 Ch.1 Pan : Ch. 23 Dimmer Fine Set Active Mode 3 Ch.1 Pan : Ch. 24 Dimmer Set Active Mode 4 Ch.1 Pan : Ch. 30 Dimmer Fine Set Active Mode 5 Ch.1 Shutter : Ch. 21 Power Set Active Pan Reverse
(On, Off)
Tilt Reverse
(On, Off)
Lamp Presetting Lamp On/Power On
(On, Off)
Lamp Off via DMX
(On, Off)
Lamp On if DMX Present
(On, Off)
Lamp Off if not DMX
(On, Off)
Lamp Ignition delay (0..1..90) s
Lamp Low Power Delay (10....600) s
Lamp Light Sensor
(On, Off)
Display Adjusting
Display Permanent On
(On, Off)
Display Intensity
(1..10)
Display Backlight
(1..5..10)
Display Turned
(On, Off)
Blackout d.M.C.
(On, Off)
Pan/Tilt Feedback
(On, Off)
Microphone Sensitivity
(1..10..20)
Fan Modes Auto Cooling High Cooling Pan/Tilt mode
(Time mode, Speed Mode)
Active Blackout While
Pan/Tilt Moving
(On, Off)
Colour Wheels Moving
(On, Off)
IR Sensor (On, Off)
Init Effect Positions Pan
,(0-225)
: Dimmer
(0-255)
Dimmer ne (0-255)
Save
Dimmer Curve
(Curve 1, Curve 2)
CMY + CTF Curve (Curve 1, Curve 2)
Temperature Unit (°C,°F)
Default Setting
Page 22
22
Lamp On/Off (On, Off)
Test sequences
Mode 1 Pan
(0-255)
Tilt
(0-255)
Zoom
(0-255)
Run Test Program Mode 2 Run Test Program
Manual Mode
Presetted Effect Control Pan (Position 1,..., Position 6) : Dimmer (Position 1,..., Position 5) Manual Effect Control Pan
(0-255)
: Dimmer Fine
(0-255)
Stand- alone setting
Music Trigger (On, Off) Presetting Playback Disabled Test Program Program 1 Program 2 Program 3 Playing Program Test Program In Loop Program 1 In Loop Program 2 In Loop Program 3 In Loop Editing Program Program 1 Program 2 Program 3 Edit Steps Step1 : Step 99 Pan
(0-255)
:
Dimmer ne
(0-255)
Step Time (0.1-25.5s) Save Save and copy Start Step (1-99) End Step (1-99)
Reset functions
Reset All Pan/Tilt : Dimmer/Strobe
Page 23
23
Special functions
Lamp Adjustment
Pan
(0-255)
Tilt
(0-255)
Zoom
(0-255)
Effect Adjustment
DMX Values Pan
(0-255)
:
Dimmer ne
(0-255)
Calibrate Values Colour Wheel 1
(0-225)
: Dimmer
(0-255)
Save and Reset Load Default Values
Updating software
Page 24
24
9. Control menu
The control panel situated on the front panel of the base offers several features. You can simply set the DMX address, read the number of the lamp or unit hours, switch On and Off the lamp, run test, make a reset and also use many func-
tions for setting xture behaviour.
Control elements on the control board:
[RNS] encoder wheel-moves between menu items on the the same level, scrolls between values. [ESC] button-leaves menu without saving changes
[ENTER] button-enters menu, conrms adjusted values and leaves menu
After switching the xture on, Press [ENTER], the display shows the initial screen: the display shows current address:
The main menu of the control panel is accessed by pressing [ENTER] button. To browse through the menu, rotate [RNS] wheel. To select a function or submenu, press [ENTER] button. Presetted options are displayed negative.
9.1 Fixture Address
Use this menu to set the DMX address.
DMX Address - Select this submenu to set DMX start address.
Ethernet Settings - Select this submenu to set the xture for Ethernet operating. Set Ethernet Mode - Select this submenu to select Ethernet operating mode:
Disable Ethernet - disables network operating. Ethernet -
Data are received to the Ethernet input of the xture - every xture from xture chain has to
be connected to the network.
Ethernet/DMX -
Data go from Ethernet input „through” the xture to the DMX output of the xture- it is
possible to connect the next xture to DMX output and to make a DMX chain.
Set IP Address - Select this submenu to set IP address.IP address is the Internet protocol address.
The IP uniquely identies any node (xture) on a network. There can't be 2 xtures with the
same IP address on the network!
Default IP Address - Presetted IP address, you can edit only rst number of IP address (2 or 10)
e.g. 002.019.052.086.
Custom IP Address - The option enables edit all numbers of IP address e.g. 002.019.052.086.
To set the custom IP address:
1. Select „Custom IP Address” and press [ENTER].
2. Use RNS wheel to set the rst number of IP addres
3. Press [ENTER] to move on the second number of IP address
4. Repeat steps 2 and 3 for the third and the fourth number of IP address. If you want to return back on the previouly editted number, press [ESC]. Set ArtNet Universe -
Select this submenu to set a Universe (0-255). The Universe is a single DMX 512 frame
of 512 channels.
9.2 Fixture informations
Use this menu to read an useful information about the xture.
Power On Time - Select this submenu to read the number of operation hours. Total Hours -
The function shows the total number of the operation hours since the ColorWash 1200E
AT
has been fabricated.
Resetable Hours -
The function shows the number of the operation hours that the ColorWash 1200E
AT
has been powered on since the counter was last reset. In order to reset this counter to 0, press
[ENTER] twice. Lamp On Time - Select this submenu to read the number of the operation hours with the lamp on. Total Hours -
The function shows the total number of the operation hours with the lamp on since
the ColorWash 1200E AT has been fabricated. Resetable Hours -
The function shows the number of the operation hours with the lamp on that the ColorWash 1200E AT has been powered on since the counter was last reset. In order to reset this counter to 0, press [ENTER] twice.
Lamp Strikes - Select this submenu to read the total number of the lamp strikes. Total Hours - The function shows the total number of the lamp strikes since the ColorWash 1200E
AT has been fabricated. Resetable Hours - The function shows the number of the lamp strikes since the counter was last reset. In order to reset this counter to 0, press [ENTER] twice.
Page 25
25
Air Filters --- Regular cleaning of the air lters is very important for the xture´s life and performance.Bildup of dust,dirt and fog uid residues reduces the xture´s light output and cooling ability.The two items of this menu help you to keep cleaning peeriod of the air lters.
Set alert period - Cleaning schedule for the xture depends on the operating enviroment.
It is therefore imposible to specify accurate cleaning interval.This function allows
you to change the cleaning interval of the air lters.This "alert" value is 50 hours and it is set as default.Inspect the xture within its 50 hours of operation to see whether cleaning is necessary.If clening is required,clean all air lters and change the value in this menu
on acceptable level.Min. level of alert period is 10 hours, max. is 300 hours.
Elapsed Time - The option allows you to read the time which remains to cleaning air lters.
The time period is set in the menu mentioned above. Expired time period is signalized by a negative mark at the time value and a warning icon
(triangle) on the display with the following message: "Clean Air Filters" Clean the lters and reset this menu item (by pressing "Enter" button twice while this menu
is highlighted) to start the new time countdown.
Fixture Temperatures - Select this submenu to read the temperatures of the xture:
Current - Select this function to read the current temperatures of the xture inside (Board Temp., Ambient Temp.,Near Lamp Temp.) Maximum nonresetable -
The function shows the max.temperatures of the xture inside (Board Temp., Ambient
Temp., Near Lamp Temp.) since the ColorWash 1200E AT has been fabricated. Maximum resetable -
The function shows the maximum temperatures of the xture inside (Board Temp., Ambient
Temp., Near Lamp Temp.) since the respective counter was last reset. In order to reset desired counter to 0, press [ENTER] twice. Measurement points: Board Temp. - temperature on the main board in the xture base. Ambient Temp. -
temperature of the air which is sucked to the xture base. This temperature can be different
from the real ambient temperature due to e.g. suction of the hot air from the xture head to the base if the xture
is hanging at the ceiling. Please note that the ambient temperature should not exceed 40°C.
Near Lamp Temp. - temperature in the lamp chamber.
Fans Speed - Select this function to read the actual speed of the fans(revolutions per minute): Fan1 - The fan cools the lamp peak Fan2 - The fan cools the lamp base Fan 3 - The fan on the rear left side of the head Fan 4 - The fan on the rear right side of the head Fan 5 - The left fan at the CMY module Fan 6 - The right fan at the CMY module Fan 7 - The Fan iside the head Fan 8 - The fan on the front left side of the head Fan 9 - The fan on the front right side of the head
Location of the fans:
(Top view)
Head Board
Fan 9
Fan 6
Fan 2
Fan 8
Fan 4
Near lamp Temp.
Fan 1
Fan 5
Fan 7
Fan 3
Page 26
26
DMX Values - Select this function to read DMX values of each channel received by the xture.
Product IDs - Select this function to read the MAC address of the xture or the RDM UID number. Software Version - Select this function to read the software version of the xture modules:
IC1 MB - Main processor on the main board in the xture base IC2 MB - Tilt processor on the main board in the xture base IC3 MB - Pan procesor on the main board in the xture base IC4 MB - EEprom on the main board in the xture base IC1 HB - CMY and conversion lter 3200K processor on the board in the xture head IC2 HB - Dimmer and cyan processor on the board in the xture head IC3 HB - Fresnel 1/2 and zoom processor on the board in the xture head IC4 HB - Colour wheel 1/colour wheel 2 processor on the board in the xture head
IC1 DS - Display processor on the display module in the xture base
IC2 DS - Memory on the display module in the xture base
Location of the fans, processors and temperature measuring points:
Base (Top view):
Display module (Rear view)
9.3 Personality
Use this menu to to modify ColorWash 1200E AT operating behavior.
User mode -
ColorWash 1200E AT allows you to recall up to 3 user settings. After switching the xture on for the rst time,
the User A settings are active. All changes made in „Personality” menu, „Fixture Address” menu and Music
Trigger and
Presetting Playback functions from „Stand-alone setting” menu are saved to the User A settings. If you now set the User B settings active, from this moment these changes are saved to the User B settings. After switching the xture off and on,
the User B setting is active. In this way you may use 3 xture operating behaviour.
User A Settings - The function recall the user A settings. User B Settings - The function recall the user B settings. User C Settings - The function recall the user C settings.
Pan Reverse - Select this function to invert the pan movement.
Tilt Reverse - Select this function to invert the tilt movement.
DMX Preseting - Select this function to set desired effects assigning to the channels. You can choose 5 effects orders
Page 27
27
(Mode 1-17 channels,Mode 2-23 channels,Mode 3-24 channels,Mode 4-30 channels,Mode 5-21 channels). Please refer to the chapter “ DMX protocol“ for detail description.Mode 1 is default channels setting: Please refer to the chapter „DMX - protocol” for detail description.
Lamp Presetting - Select this menu to change the lamp „behaviour”. Lamp On/Power On - Select this function to turn the lamp on automatically after switching the xture on. Lamp Off via DMX - Select this function to switch off the lamp via DMX. Lamp On if DMX Present - This function allows you to strike the lamp automatically after 26 seconds if DMX
signal is present on the data link.If the ignition is unsuccessfull (e.g.lamp is too hot), the xture will try to ignite
the lamp after next 26 s. This process will repeat until the lamp lights. Lamp Off if not DMX -
This function allows you to switch Off the lamp automatically after 2 minutes if DMX signal
is missing on the data link. Lamp Ignition Delay
- This function allows you to set the time delay( 0-90s) before the lamp will be ignited. This
setting will not affect starting the lamp direct from the control panel (menu "Lamp On/Off").
Lamp Low Power Delay
-
This function enables set the time period after that the lamp power will be reduced
if the shutter/dimmer is closed.The delay time can be set up to 600seconds.Default setting is10s.
Lamp Light Sensor - Select this function to switch the lamp light sensor on or off. The option „On” is for the standard operation. Important: The option „Off” is for „emergency operation” only if the lamp light sensor is defective and you will wait for a service intervertion! If the lamp light sensor is switched off and at switching the lamp on the electronics will still try to ignite the lamp until it shines (even when the lamp is damaged or absent), on this account some electronics parts could be damaged!
Display Adjusting - This function allows you to change the display settings. Display Permanent On - This function allows you to keep the display on or to turn off automatically 2 minutes after last pressing any button(or a wheel movement) on the control panel. Display Intensity - Select this function to adjust the display intensity (1-min.,10-max.). Display Backlight - Select this function to adjust the display backlight (1-min.,10-max.). Display Turned - Select this function to turn the display by 180°.
Blackout d.M.C. - Select this function to enable the blackout during the head movement correction (if the moving head lost its right pan/tilt position for a short moment).
Pan/Tilt Feedback - This function allows to return the mowing head to the required pan/tilt position after changing the position by external force (e.g.by stroke).
Be careful, the Pan/Tilt Feedback OFF is not the standard operation and the head of the xture can be demaged! Note: If the feedback was switched off, the pan/tilt-position is changed by an external force and the feedback is switched
on again, the moving head might not to be synchronized with the DMX signal. You have to make a reset in order to synchronize the moving head with the DMX signal.
Microphone Sensitivity - Select this function to adjust the microphone sensitivity from 1(maximum) to 20 (minimum). If the sensitivity is correctly adjusted, the mark will appear (blinking in the bass beat.)
Fan Modes - By using this function you can choose 2 types of the fan speed operating modes. Auto Cooling - The fans automatically raise their speed in order to control inside temperature of the lighting, if the temperature inside increases about certain level (the low fan speed reduces the cooling of the lighting). This cycle can repeat several times until the temperature inside is on a suitable level. High Cooling - The cooling fans work on max. speed (max. cooling). This mode we recommend for high ambient temperature (30 °C and more).
Pan/Tilt mode - Use this menu to set the character of the pan/tilt movement. Time mode - Pan and tilt will move with different speeds and they will come at the same time to end point (pan and tilt sets its optimal speed). Speed Mode - Pan and tilt will move with the same speed as adjusted with the channel 5 (Pan/Tilt speed). E.g.pan will come to the end point and wait for tilt, which has longer track.
Active Blackout while: - Use this function if you wish to close the light output during effect changes. Pan/Tilt Moving - This function closes the light output during pan/tilt changes.
Colour Wheels Moving - This function closes the light output during colour changes.
IR Sensor - Select this function to switch on/off infra-red remote control.
Init Effect Positions - Select this function to set all effects to the desired positions. After switching the xture on (if DMX
is not connected), all effects will move to this init positions.
Page 28
28
Dimmer Curve - Select desired dimmer running.
Curve 1 Curve 2
CMY + CTF Curve - Select desired CMY lters + conversion temperature lter running.
Curve 1 Curve 2
Temperature Unit --- Select this menu in order to display xture temperatures in °C or °F.
Default Settings - Select this option to reset all xture personalities to the default values.
9.4 Lamp On/Off
Use this option in order to switch on/off the lamp. It is also important to note, that the lamp is cold restrike type, that means, that it has to be cold before striking.
9.5 Test sequences
Use this menu to to run a special demo-test sequences without an external controller, which will show you some possibili­ties of using ColorWash 1200E AT. Mode 1 - This mode is suitable for projections on the wall, ceiling or ground without any head movement. Mode 2 - This mode uses all ColorWash 1200E AT functions including pan/tilt movement and therefore is good for
a complete introduction of the xture.
9.6 Manual mode
Presetted Effects - Select this menu to call up presetted positions of channel effects. Manual Effect control - Select this menu to control channels by control elements on the control board.
9.7 Stand-alone setting
Use this menu to set options for stand-alone mode as a selection of the playing program,programming and modifying current programs. Music Trigger - Select this function to enable the sound control of the running programs via the built-in microphone. Presetting Playback - This function allows you to select the program which will be played in the
stand-alone mode after switching the xture on.Selected program will be played continuously in a loop.
Disabled - The option disables „Presetting playback” function. Test Program - The option will start built-in test program. Program 1 - The option will start created program No.1 Program 2 - The option will start created program No. 2 Program 3 - The option will start created program No. 3
Note: If the xture operates in the controller mode (DMX controller is connected) and any program from this menu is selected, in this case the xture will not respond to the DMX controller after switching on and will play selected program.
Playing program -Select this menu to run a built-in program or the 3 freely-programmable programs in a loop. Test Program In Loop - The option starts built-in test program. Program 1 In Loop - The option starts created program No. 1 Program 2 In Loop - The option starts created program No. 2
Page 29
29
Program 3 In Loop - The option starts created program No. 3 Select the program you wish and press [ENTER]. The selected program starts running. By Pressing [ENTER] again is possible to pause the program running.
Editing Program - Select this menu to edit or create the program. The ColorWash 1200E AT has one built-in program and the 3 free programs, each up to 99 steps. Each program step has a step time. Step time-the time, during which effects last in the current step.
Procedure:
1. Select the program you want to edit („Program 1” - „Program 3”) and press [ENTER].
2. Select „Edit Steps” menu and press [ENTER].
3. Select the desired program step („Step 01” - „Step 99”) and press [ENTER]. 4 Select the desired item and press [ENTER]. Now you can edit DMX value for selected item: "Pan"- a coarse pan, value 0-255 "Pan Fine" - a ne pan, value 0-255 "Tilt" - a coarse tilt, value 0-255 "Tilt Fine" - a ne tilt, value 0-255 "Pan/Tilt Speed " - a speed of pan/tilt movement, value 0-255 "Spec. Func." - a special functions, lamp on/off, reset, value 0-255 "Pan/Tilt Macro" - a pan/tilt macro, value 0-255 "P./T.Macro Speed" - a pan/tilt macro speed, value 0-255 "Colour Wheel 1" - a colour wheel 1, value 0-255 "Colour 1 Fine" - a colour wheel 1-ne positioning, value 0-255 "Colour Wheel 2" - a colour wheel 2, value 0-255 "Colour 2 Fine" - a colour wheel 2-ne positioning, value 0-255 "Cyan" - a cyan, value 0-255 "Magenta" - a magenta, value 0-255 "Yelow" - an yellow, value 0-255
"Conversion Filter" - a conversion temperature lter, value 0-255
"CMY Colour Macro" - a CMYcolour macro, value 0-255 "Effect Speed" - a effect speed, value 0-255
"Effect Speed. Assig." - a effect speed assigning,value 0-255 “Fresnel opening” - a fresnel opening,value 0-255 “Zoom” - a coarse zoom,value 0-255
“Zoom ne” -
a ne zoom movement,value 0-255
"Shutter/Strobe" - a shutter and strobe,value 0-255 "Dimmer" - a dimmer intensity-coarse, value 0-255
"Dimmer Fine" - a dimmer intensity-ne, value 0-255
5. Select „Save” or „Save and Copy” and press [Enter] to conrm adjusted values:
"Save" - saving the current prog. step "Save and Copy" - saving and copying the current prog. step to the next prog. step.
6. Go on next prog. step and repeat this procedure (steps 4 and 5). After creation the program, you can simply reduced its length (by changing the start/end steps) using the „Start Step” and „End Step” menu.
9.8 Reset functions
The ColorWash 1200E AT can be reset totally or by function modules. Select relevant function to run a reset:
Reset All - This function enables the xture to index all effects and return to their standard positions. Pan/Tilt - This function resets pan and tilt. Colour System - This function resets colour wheels and CMY/conversion lter module. Dimmer/Strobe - This function resets dimmer/strobe module. /Zoom/Fresnel - This function resets zoom and inside Fresnel lens .
9.9 Special functions
Use this menu for special services like adjusting lamp or adjusting effects. Lamp Adjustment - This function can be used when you make the ne adjustment of the lamp. If you select this function,
all effects will be canceled, shutter will be opened and the dimmer intensity will be set onto 100%. By using the
options „PAn, Tilt, Zoom” you can aim the light at a at surface (wall) and perform the ne lamp
adjustment. Effect Adjustment - By this function you can calibrate and adjust the effects to their standard/right positions. Disconnect the DMX controller from the xture and select „DMX Values” menu. The display shows step by step effects by which you can adjust the xture to the required position before the function calibration. When the positioning is nished, select
„Calibrate Values” and press [ENTER]:
1. Calibration via the control board
Select desired effect, press [ENTER] and adjust its right value (0 - 255). This can be repeated for each calibred effect if it is required. When the calibration is nished, it is necessary to use the „Save and Reset” function to write the calibration values to the memory and to make a reset in order to check the newly adjusted positions of the calibrated effects.
Page 30
30
List of the calibrated effects:
Colour Wheel 1 Magenta Right Fresnel Open. Colour Wheel 2 Yellow Left Fresnel Open. Cyan Conversion Filter Zoom Dimmer
2. Calibration via the DMX controller
Connect the DMX controller to the xture. Select desired effect and press [ENTER]. Now you can calibrate the selected
effect by your controller.
Effect Mode 1 Mode 2 Mode 3 Mode 4 Mode 5
Colour wheel 1 channel 18 channel 24 channel 25 channel 31 channel 22 Colour wheel 2 channel 19 channel 25 channel 26 channel 32 channel 23 Cyan channel 20 channel 26 channel 27 channel 33 channel 24 Magenta channel 21 channel 27 channel 28 channel 34 channel 25 Yellow channel 22 channel 28 channel 29 channel 35 channel 26
Conversion lter channel 23 channel 29 channel 30 channel 36 channel 27
Right Fresnel Open. channel 24 channel 30 channel 31 channel 37 channel 28 Left Fresnel Open. channel 25 channel 31 channel 32 channel 38 channel 29 Zoom channel 26 channel 32 channel 33 channel 39 channel 30 Dimmer channel 27 channel 33 channel 34 channel 40 channel 31 After having calibrated required effects ,use the „Save and Reset” function to write the calibration values to the memory
and to make a reset in order to check the newly adjusted positions of the calibrated effects.
Item „Load Default Values” enables to load default factory calibration values.
Updating software - Using this function you can update software in the xture via PC and serial link.
The following are required in order to update software:
- PC running Windows 95/98/2000/XP or Linux
- DMX Software Uploader
- Flash cable RS232/DMX (No.13050624)
Note1:Software update should execute a qualied person.If you lack qualication, do not attempt the update
yourself and ask for help your ROBE distributor. Note 2:DMX address, IP address ,programs 1-3 and all functions in menu Personality will be set to their default values.
To update software in the xture:
1.Installation of DMX Software Uploader.
1.DMX Software Uploader program is available from the ROBE web site at WWW.robe.cz.
2.Make a new directory ( e.g. Robe_Uploader) on your hard disk and download the software to it.
3.Unpack the program from the archive. Program le has name:DSU_name of corresponding
xture_SoftwareID.If the Robe xture is produced in magnetic and electronic ballast version, name
of DMX Software Uploader is the same for both versions.
SoftwareID describes the versions of xture software included in DMX Software Uploader. Higher
number means later software versions.
2.Fixture software updating.
1.Determine which of your COM port is available on your PC and connect it with to the DMX input of the
xture using the Flash cable. Do not extend this cable! Disconnect the xture from the other xtures in DMX chain! Turn on the computer and the xture. Make sure that the lamp is switched off.
2.Switch the xture to the update mode by selecting the option Updating Software in menu Special Functions on the xture control panel.(From this option you cannot return back to the main menu. If you do not want to continue in software update, you have to switch off and on the xture to leave this option!)
3.It is recommended that you exit all programs before running this Software Uploader.
4.Start the Software Uploader program. Select desired COM and then click Connect button. If the conection is OK, click Start Uploading button to start uploading. It will take several minutes to perform
software update. If the option "Incremental Update"isn´t checked ,all processors will be updated (including
processors with the same software version). If you wish to update only later versions of processors, enable the Incremental Update check box. Avoid interrupting the process. Update status is being displayed in the list window.
When the update is nished, the line with the text “The xture is successfuly updated‘ will appear in this window and the xture will reset with the new software. Note: In the case of interruption of the upload process (e.g. power cut), the xture remains in the update mode and you
have to repeat the software update again.
For example: The xture was switched off before nishing software upload. After switching the xture on again, the xture
is still in the update mode and the display is dark. Restart the Software Uploader program and repeat software update from your PC.
10. Power down mode
This mode omits xture reset after switching the xture on and reduces motor powers of the xture. „Power down mode” is useful in special casech.g. if the xture is in a ight case and you want to set its DMX address without taking it out from
the case. To enter „Power down mode”: Press and hold [ENTER] and at the same time switch on the Power switch. The following message appears:
Page 31
31
Realy Skip Initial Reset? Escape/Enter
Press [ENTER] to activate „Power down mode” without xture reset.Now you can set features and behaviour of the xture by using „Fixture Address” menu and „Personality” menu.It is expected,that this mode will be exited by switching the xture off, but if you want to go directly to „normal operation mode”, execute any xture reset.
Note: All motors in „Power down mode” are deactivated and switching the lamp on from the control panel is blocked.
11. RDM
This xture supports an RDM operation. The RDM (Remote Device Management) is a bi-directional communications protocol for use in DMX512 control systems, it is the new open standard for DMX512 device conguration and status monitoring. The RDM protocol allows data packets to be inserted into a DMX512 data stream without adversely affecting existing
non-RDM equipment. By using a special „Start Code,“ and by complying with the timing specications for DMX512, the RDM protocol allows a console or dedicated RDM controller to send commands to and receive messages from specic
moving lights.
The ROBE DreamBox with an additional ROBE RDM-network software provides the RDM functionality. The DreamBox supports RDM - new control protocol featuring AutoPatch and Fixture Status Monitoring.
The list of RDM commands for ColorWash 1200E AT is the following:
Parameter ID Discovery command SET command GET command
DISC_UNIQUE_BRANCH *
DISC_MUTE *
DISC_UN_MUTE *
DEVICE_INFO
*
SUPPORTED_PARAMETERS
*
SOFTWARE_VERSION_LABEL
*
DMX_START_ADDRESS
* *
IDENTIFY_DEVICE
* *
DEVICE_MODEL_DESCRIPTION
*
MANUFACTURER_LABEL
*
DEVICE_LABEL
* *
SENSOR_DEFINITION
*
SENSOR_VALUE
*
DISPLAY_INVERT
* *
DISPLAY_LEVEL
* *
PAN_INVERT
* *
TILT_INVERT
* *
DEVICE_RESET
*
DMX_PERSONALITY
* *
DMX_PERSONALITY_DESCRIPTION
*
STATUS_MESSAGES
*
STATUS_ID_DESCRIPTION
*
LAMP_STATE
* *
LAMP_ON_MODE
1
* *
DEVICE_HOURS
2
*
LAMP_HOURS
2
*
LAMP_STRIKES
2
*
1
...Another options for this command (only for Robe´s xtures):
value PARAMETER_DATA=0x84 - lamp OFF by DMX value on DMX channel value PARAMETER_DATA=0x88 - lamp OFF if DMX is not present
2
...Commands relative resetable values
Page 32
32
12. Error and information messages
Occured errors during xture operation are signaled by warning icon on the display:
Press [ESC] to see the current error messages. Description of the error messages:
Active Lamp Timer
This message appears if you try to switch on the lamp within 5 minutes after having switched it off (the lamp is too hot).
The message will appear on the display if the lamp doesn't ignite within 28 seconds. The ColorWash 1200E AT will store
this information and automatically ignite the lamp when the 5 minutes period has expired. Caution: The message is disabled if the lamp light sensor (function “Lamp Sensor” in menu Personality) is switched Off.
Starting lamp
This message appears during igniting the lamp or together with the message “Active Lamp Timer”.
Lamp Error
The ignition of the lamp is seven times unsuccessful (the "Active Lamp Timer" message appeared six times before), and
the display shows "Lamp Error", meaning that the lamp could be damaged or even missed or there could be a failure on the ignitor or ballast. Please place or replace the lamp and contact your dealer if the situation was not caused by the lamp. Caution: The message is disabled if the lamp light sensor (function „Lamp Sensor” in menu Personality) is switched off.
Overheated ->Lamp Off
This message informs that the xture head is overheated and the lamp was switched off by its temperature sensor.
Overheated ->Lamp low
This message informs that the xture head is overheated and the lamp power was reduced to 700 W.After 10 minutes the
lamp power will be switched to the full power.
Lamp Sensor Error
This message informs the lamp light sensor is failed. Caution: The message is disabled if the lamp sensor (function Lamp Sensor in menu Personality) is switched Off.
Short Power Error
This message will appear if the xture was shortly disconnect from the main.
Supply Frequency Error
This message will appear if the frequency of the main is not standard 50 or 60 Hz.This message can appear as a result of the interference during the lamp starting (if the lamp or igniter is old) or as a result of the interference by neighbouring devices. In these cases the message does not affect the xture operating!
The following error messages are separated into 2 groups:
xxxx xxxx Error 1 (e.g. Colour Wheel 1 Error 1, Colour Wheel 2 Error 1) xxxx xxxx Error 2 (e.g. Colour Wheel 1 Error 2, Colour Wheel 2 Error 2)
There are some possible reasons of faults:
Message Characteristic fault
xxxx xxxx Error 1 Magnetic sensor is permanently On (e.g. leading wire is short- circulated,defective stepping motor, defective control circuit on the PCB)
xxxx xxxx Error 1/xxxx xxxx Error 2 Magnetic sensor is permanently Off (e.g. leading wire is disconnected, (together) defective magnetic sensor, missing magnet), defective stepping motor.
Colour Wheel 1 Error 1 (Colour Wheel 1 Error 2)
The messages will appear after the reset of the colour wheel if this wheel is not located in the default position.
Colour Wheel 2 Error 1 (Colour Wheel 2 Error 2)
The messages will appear after the reset of the colour wheel if this wheel is not located in the default position.
Cyan Lamella Error 1 (Cyan Lamella Error 2)
Page 33
33
The messages will appear after the reset of the CMY module if the cyan lamellas are not located in the default positions.
Magenta Lamella Error 1 (Magenta Lamella Error 2)
The messages will appear after the reset of the CMY module if the magenta lamellas are not located in the default positions.
Yellow Lamella Error 1 (Yellow Lamella Error 2)
The messages will appear after the reset of the CMY module if the yellow lamellas are not located in the default positions.
CTO Lamella Error 1 (CTO Lamella Error 2)
The messages will appear after the reset of the CTO module if the CTO lamellas are not located in the default positions.
Zoom Error 1 (Zoom Error 2)
The messages will appear after the reset of the zoom module if the module is not located in the default position.
Pan Error 1 (Pan Error 2)
The messages will appear after the reset of the yoke if the yoke is not located in the default position.
Tilt Error 1 (Tilt Error 2)
The messages will appear after the reset of the head if the head is not located in the default position.
13. Technical specications
Power supply:
Voltage: ....................................... 100/120/208/230/250V AC, 50/60Hz ~
Main fuses: Live fuse: ......... T10A@230V
Neutral fuse: .... T10A@230V
Live fuse: ......... T20A@120V
Neutral fuse: .... T20A@120V
Power consumption: ..................... 1500 VA (steady state)
Lamp:
Philips MSR 1200 SA, base: GY22, colour temperature: 5600 K, average lamp life: 750 h
Optical System:
- High luminous-efciency parabolic reector
- Focus lens and multistep zoom lenses system
- Beam angle: 10°- 87° (depends on the front lens)
- All lenses are anti-reection coated
CMY-colours mixing module
- Smooth CMY colour mixing system
- Colour temperature correction lter lowers the colour temperature from 5600K to 3200 K
- 63 colour macros
Colour wheel 1
- 4 dichroic lters, UV lter, 6000K temp. lter plus white
- Colour wheel with variable rotation speed in both directions
- All colour-modules are interchangeable
- Random colour selection by audio control
- Auto random colour selection
Colour wheel 2
- 6 colour lters plus white
- Colour wheel with variable rotation speed in both directions
- All colour-modules are interchangeable
- Random colour selection by audio control
- Auto random colour selection
Strobe
- Strobe effect with variable speed (max.15 ashes per second)
- Preprogrammed macros with variable/random pulse effects
Dimmer
- Smooth micro-step driven dimming
Page 34
34
Zoom
- Motorized zoom with range: Fresnel lens Beam angle Intensity-center(Lux) at 5 meters LightMax mode 10° 71800 Minimum zoom 13° 30270 Maximum zoom 44° 7040
Wide-angle lens Beam angle Intensity-center (Lux) at 5 meters LightMax mode 68° 1940 Minimum zoom 75° 1760 Maximum zoom 87° 1690
Motors
- 14 high quality stepping-motors controlled by microprocessors
Electronics
- control via control panel with graphic LCD display and 2 buttons/rotating wheel
- Readout xture and lamp usage,receiving DMX values, temperature, etc
- Built-in analyzer for easy fault nding,error messages
- Remotely switching on/off the lamp by DMX
- Bilt-in demo sequences
- Silent fans cooling
- Stand alone operation
- Self-resetable thermo-fuse
- Digital serial input DMX-512
- Ethernet connector
- Electronics ballast
- 5 control-channels presettings (17,21,23,24, and 30 control channels)
- Support RDM
Data input/output
- 3-pin and 5-pin XLR male sockets for DMX data input
- 3-pin and 5-pin XLR female sockets for DMX data output
- RJ- 45 male socket for Ethernet connection
Pan/Tilt
- Pan movement range 530°
- Tilt movement range 280°
- 16 bit movement resolution
- Automatic Pan/Tilt position correction
- Remotely controllable speed of Pan/Tilt movement for easy programming
- Maximum Pan movement 530° in 4,5 s
- Maximum Tilt movement 280° in 2,6 s
Rigging
- Stands directly on the oor
- Mounts horizontally or vertically with 2 clamps
- fastening of the clamp brackets in 4 positions
- Safety chain/cord attachment apertures
Temperatures
- Maximum ambient temperature: 40° C
- Maximum housing temperature of the head: 130° C
Minimum distances
- Min. distance from ammable surfaces: 1.2 m
- Min. distance to lighted object: 4 m
Accessories:
Mounting bracket Omega CL assembled (No. 99010420) .......... 2 pieces
Module of front wide-angle lens (No. 99010879)..........................1 piece
Colour module-Amber (No. 99011348).........................................1 piece
Colour module-Light red (No. 99011349)......................................1 piece
Optional acesories:
Remote control IR (No. 13050419) Flash cable RS232/DMX (No.13050624) Top hat standard 45 (No.10980044)
Page 35
35
Top hat long 70 (No.10980045) Top hat 3-ring 45 (No.10980046) Top hat 3-ring 70 (No.10980050) Module of lens D200 PC (No.99010878-01)
Beam path - Fresnel lens
Page 36
36
Dimensions and weight
- Weight (standard Fresnel lens): 40.8 kg
- Dimensions of the xture:
- Dimensions of the optional top hats:
Page 37
37
Specications are subject to change without notice.
grid
air filter
Velcro fastener
14. Maintenance and cleaning
It is absolutely essential that the xture is kept clean and that dust, dirt and smoke-uid residues must not build up on or within the xture. Otherwise, the xture‘s light-output will be signicantly reduced. Regular cleaning will not only ensure the maximum light-output, but will also allow the xture to function reliably throughout its life. A soft lint-free cloth moistened with any good glass cleaning uid is recommended, under no circumstances should alcohol
or solvents be used!
DANGER ! Disconnect from the mains before starting any maintenance and cleaning work!
The front objective lens will require weekly cleaning as smoke-uid tends to building up residues, reducing the light-output
very quickly. The cooling-fans should be cleaned monthly.
The interior of the xture should be cleaned at least annually using a vacuum-cleaner or an air-jet. Dichroic colour lters, CMY lamelas and the internal lenses should be cleaned monthly.
Remove dust and dirt from the fans and cooling vents using a soft brush and vacuum-cleaner.
Important! Check the air lters periodically and clean before they become
clogged!
Clean the air lters from the front fans with a vacuum cleaner, compressed air or you can wash them and put back dry.
Replacing the air lters.
1)Disconect the xture from power.
2)Remove both top and bottom cover of the head (by loosening the 4 quarter-turn fasteners on each cover)
3)Remove the air lters (they are xed with a Velcro fastener) from grids.
4)Clean or replace the air lters.
5)Place the lters on the grid and put head cover back.
6)Reset the elapsed time counter in menu Fixture information (Fixture Information--->Air Filters---> Elapsed Time.
Replacing the fuse.
If the lamp burns out, the ne-wire fuse of the device might fuse, too. Only replace the fuse by a fuse of the same type
and rating. Before replacing the fuse, unplug mains lead.
1) Unscrew the fuse holder on the rear panel of the base with a tting screwdriver from the housing (anti-clockwise).
2) Remove the old fuse from the fuse holder.
3) Install the new fuse in the fuse holder.
4) Replace the fuseholder in the housing and x it.
More complicated maintenance and service operations are only to be carried out by authorized dealers.
Page 38