Robe Color Spot 575AT, Color Spot 575AT at series User Manual

Color
Spot
575
AT
USER MANUAL
Version: 1.4
ROBE® Lighting s.r.o. Czech Republic www.robe.cz
3
Color
Spot
575
AT
Table of contents
1. Safety instructions 4
2. Operating determinations
4
3. Description of the device
5
4. Installation
6
4.1 Fitting the lamp 6
4.2 Lamp adjustment 7
4.3 Inserting / Exchanging colours and gobos 7
4.4 Replacing the 3-facet prism 8
4.5 Connection to the mains 8
4.6 Changing the power supply settings-magetic ballast 9
4.7 Rigging the xture 10
4.8 DMX-512 connection/connection between xtures 11
5. DMX protocol 12
6. Controller mode 1
7
6.1 DMX addressing 17
6.2 Remotely controllable functions 17
7. Stand - alone mode 18
8. Control menu map 1
9
9. Control menu 2
1
9.1 Fixture Address 21
9.2 Slave control 21
9.3 Fixture informations 21
9.4 Personality 22
9.5 Lamp On/Off 23
9.6 Manual mode 23
9.7 Test sequences 23
9.8 Stand-alone setting 24
9.9 Reset functions 24
9.10 Special functions 25
10. Power down mode 25
11.RDM 25
12. Error and information messages 2
7
13. Technical specications 2
8
14. Maintenance and cleaning 3
0
4
CAUTION! Keep this device away from rain and moisture! Unplug mains lead before opening the housing!
FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOU INITIAL START - UP!
1. Safety instructions
Every person involved with installation and maintenance of this device have to:
- be qualiled
- follow the instructions of this manual
CAUTION! Be careful with your operations. With a high voltage you can suffer a dangerous electric shock when touching the wires!
This device has left our premises in absolutely perfect condition. In order to maintain this condition and to ensure a safe ope­ration, it is absolutely necessary for the user to follow the safety instructions and warning notes written in this manual.
Important:
The manufacturer will not accept liability for any resulting damages caused by the non-observance of this manual or any
unauthorized modication to the device.
Please consider that damages caused by manual modications to the device are not subject to warranty.
Never let the power-cord come into contact with other cables! Handle the power-cord and all connections with the mains with particular caution!
Make sure that the available voltage is not higher than stated on the rear panel.
Always plug in the power plug least. Make sure that the power-switch is set to off -position before you connect the device to the mains. The power-plug has to be accessable after installing the device.
Make sure that the power-cord is never crimped or damaged by sharp edges. Check the device and the power-cord from time to time.
Always disconnect from the mains, when the device is not in use or before cleaning it. Only handle the power-cord by the plug. Never pull out the plug by tugging the power-cord.
This device falls under protection class I. Therefore it is essential to connect the yellow/green conductor to earth.
The electric connection, repairs and servicing must be carried out by a qualied employee.
Do not connect this device to a dimmer pack.
Do not switch the xture on and off in short intervals as this would reduce the lamp’s life.
During the initial start-up some smoke or smell may arise. This is a normal process and does not necessarily mean that the device is defective.
Do not touch the device’s housing bare hands during its operation (housing becomes hot)!
For replacement use lamps and fuses of same type and rating only.
CAUTION ! EYEDAMAGES ! Avoid looking directly into the light source (meant especially for epileptics) !
2. Operating determinations
This device is a moving-head spot for creating decorative effects and was designed for indoor use only.
If the device has been exposed to drastic temperature uctuation (e.g. after transportation), do not switch it on immedia­tely. The arising condensation water might damage your device. Leave the device switched off until it has reached room temperature.
5
Never run the device without lamp!
Do not shake the device. Avoid brute force when installing or operating the device.
Never lift the xture by holding it at the projector-head, as the mechanics may be damaged. Always hold the xture at the
transport handles.
When choosing the installation-spot, please make sure that the device is not exposed to extreme heat, moisture or dust.
There should not be any cables lying around. You endanger your own and the safety of others!
The minimum distance between light-output and the illuminated surface must be more than 2 meters.
Make sure that the area below the installation place is blocked when rigging, derigging or servicing the xture.
Always x the xture with an appropriate safety-rope. Fix the safety-rope at the correct holes only.
Only operate the xture after having checked that the housing is rmly closed and all screws are tightly fastened.
The lamp must never be ignited if the objective-lens or any housing-cover is open, as discharge lamps may explose and
emit a high ultraviolet radiation, which may cause burns.
The maximum ambient temperature 40° C must never be exceeded. Otherwise, the lamp is switched off and the xture
is out of operation for 5 minutes.
CAUTION! The lens has to be replaced when it is obviously damaged,
so that its function is impaired, e. g. due to cracks or deep scratches!
Operate the device only after having familiarized with its functions. Do not permit operation by persons not qualied for
operating the device. Most damages are the result of unprofessional operation!
CAUTION! The lamp has to be replaced when it is damaged or deformed due to the heat!
Please use the original packaging if the device is to be transported.
Please consider that unauthorized modications on the device are forbidden due to safety reasons!
If this device will be operated in any way different to the one described in this manual, the product may suffer damages and the guarantee becomes void. Furthermore, any other operation may lead to dangers like short-circuit, burns, electric
shock, burns due to ultraviolet radiation, lamp explosion, crash etc.
3. Description of the device
1 - Moving head 2 - Yoke 3 - Base 4 - Handle
6
4. Installation
4.1 Fitting the lamp
DANGER ! Install the lamps with the device switched off only. Unplug from mains before !
To insert the lamp MSR 575W/2 loosen the lamp cover at the rear of head (see the drawings ) by remowing the 3 faste­ning screws which are marked „X,Y,Z”. Carefully pull out the cover with the lamp socket assembly.If changing the lamp, remove the old lamp from the socket. Insert the lamp to the socket. Do not install a lamp with a higher wattage! A lamp like this generates temperatures the device is not designed for. Damages caused by non-observance are not subject to warranty. Please follow the lamp manufacturer‘s notes! Do not touch the glass-
-bulb with bare hands during the installation! Make sure that the lamp is installed tightly into the lampholder system. Reclose the lamp cover and tighten the 3 screws. Before striking the lamp, reset the “LAti”and “LASt” counter s in the menu of the Control Board, by pressing the “Up” and “Down” buttons in one time and then conrming with the Enter-button.
Rear panel of the base 1 - 5-pin DMX output 2 - 5-pin DMX input 3 - Power switch 4 - 3-pin DMX output 5 - 3-pin DMX input 6 - Power cord 7 - Fuse holder
Front panel of the base 1 - Display 2 - Mode-button 3 - Enter-button 4 - Up-button 5 - Down-button
7
Do not operate this xture with opened housing-cover!
4.2 Lamp adjustment
The ColorSpot 575 AT lamp holder is aligned at the factory. Due to differences between lamps, ne adjustment may
improve light performance.
Strike the lamp,open the shutter and the iris,set the dimmer intensity onto 100% and focus the light on a at surface (wall). Center a hot-spot(the brightest part of the image) by using the 3 adjustment screws „A, B, C”. Turn one screw after another a quarter-turn clokwise(counter-clokwise) to set the hot-spot in the center of the image. If you cannot detect the hot-spot, adjust the lamp until the light is evenly distributed.
4.3 Inserting / Exchanging colours and gobos
DANGER! Install the colours and gobos with the device switched off only. Unplug from mains before!
If you wish to use other forms and patterns as the standard gobos, or if colours are to be exchanged, open the top cover
of the head by loosening 4 quarter-turn fasteners on the top cover.
Colour wheel:
Gently bend out the colour module to release it from the 3 distance
slots and eject it from the pressing
snap. Put the new colour module back under the pressing snap and push it to the distance slots.
Stat. gobo wheel:
Gently bend out the gobo module to release
it from the 3 distace slots and eject it from the
pressing snap. Put the new gobo module back under the pressing snap and push it to the distace slots.
8
Rotating gobo wheel:
Gently bend out the gobo module to release it from the distance slots and eject it from the pressing snap. Press the ends of the xation ring together with an appropriate tool and remove it from the gobo holder. Remove the gobo and insert the new gobo. Press the ends of the xation ring together and insert it in the front of the gobo.
Put the gobo module back under the pressing snap and push it to the distance slots.
CAUTION! The gobo holder with the magnet must be placed
in the same position as it was placed before gobo replacement!
4.4 Replacing the 3-facet prism
Gently bend out the prism holder to release it from
the xative holes of prism module and eject it from
the pressing snap. Put the new prism holder back under the pressing snap and push it to the 3
xative holes.
4.5 Connection to the mains
Verify the power supply settings before applying power!
If you wish to change the power supply settings, see the chapter below.
Connect the xture to the mains with the enclosed power plug. If you need to install other power plug on the power cable, follow the identication table below.
The earth has to be connected!
Do not connect the xture to a dimmer system!
The occupation of the connection-cables is as follows:
Cable (EU) Cable (US) Pin International
Brown Black Live L
Liht blue White Neutral N
Yellow/ Green
Green Earth
9
4.6 Changing the power supply settings-magetic ballast
Both the transformer and the ballast must be connected correctly for the local AC voltage and frequency.
The wrong settings can cause poor performance or demage of the moving head. The factory settings are printed next to
the power switch.
If you want to change the power supply settings, follow the instructions:
1. Disconnect the xture from AC power.
2. Remove the top base cover (closest to the power cord) by loosening the 9 screws.
3. Move the wire 1 on the transformer connection block to the position according to the desired voltage.
4. Move the wires 2 and 3 on the ballast connection block to the position according to the desired frequency (voltage).
5. Close the base before applying AC power.
Examples:
Power supply settings: 230V / 50Hz
Power supply settings: 120V / 60Hz
10
4.7 Rigging the xture
DANGER TO LIFE! Please consider the respective national norms during the installation! The installation must only be carried out by an authorized dealer!
The installation of the projector has to be built and constructed in a way that it can hold 10 times the weight for 1 hour
without any harming deformation.
The installation must always be secured with a secondary safety attachment, e.g. an appropriate catch net. This secondary safety attachment must be constructed in a way that no part of the installation can fall down if the main attachment fails.
When rigging, derigging or servicing the xture staying in the area below the installation place, on bridges, under high
working places and other endangered areas is forbidden.
The operator has to make sure that safety-relating and machine-technical installations are approved by an expert before taking into operation for the rst time and after changes before taking into operation another time.
The operator has to make sure that safety-relating and machine-technical installations are approved by an expert after
every four year in the course of an acceptance test.
The operator has to make sure that safety-relating and machine-technical installations are approved by a skilled person once a year.
The projector should be installed outside areas where persons may walk by or be seated.
IMPORTANT! OVERHEAD RIGGING REQUIRES EXTENSIVE EXPERIENCE, including (but not limited to) calculating
working load limits, installation material being used, and periodic safety inspection of all installation material and the
projector. If you lack these qualications, do not attempt the installation yourself, but instead use a professional structural rigger. Improper installation can result in bodily injury and.or damage to property.
The projector has to be installed out of the reach of people.
If the projector shall be lowered from the ceiling or high joists, professional trussing systems have to be used. The projector must never be xed swinging freely in the room.
Caution: Projectors may cause severe injuries when crashing down! If you have doubts concerning the safety of a possible installation, do NOT install the projector!
Before rigging make sure that the installation area can hold a minimum point load of 10 times the projector’s weight.
Danger of re ! When installing the device, make sure there is no highly inammable material (decoration articles, etc.)
in between a distance of min. 0,5 m.
Warning ! Use 2 clamps to rig the xture on the truss.
Follow the instructions mentioned at the bottom of the base.
Make sure that the device is xed properly!
Ensure that the structure (truss) to which you are attaching
the xtures is secure.
The projector can be placed directly on the stage oor or rigged in any orientation on a truss without altering its operation
characteristics.
For overhead use, always install a safety-rope that can hold at least 10 times the weight of the xture. You must only use
safety-ropes with screw-on carabines. Pull the safety-rope through the two apertures on the bottom of the base and over
the trussing system etc. Insert the end in the carabine and tighten the xation screw.
Fixation via the omega holders
1. Bolt each clamp (1) to the omega holder (4) with M12 bolt and lock nut through the hole in the holder.
2. Fasten the omega holders on the bottom of the base by inserting both quick-lock fasteners (3) into the holes of the
base and tighten fully clockwise.
3. Fasten the safety-rope (2) through the two apertures on the bottom of the base and over the trussing system.
When installing xtures side-by-side, avoid illuminating one xture with another!
Loading...
+ 21 hidden pages