Robe ClubSpot 300, clubspot 250 CT User Manual

Page 1
1
Version 1.5
Page 2
2
Table of contents
1. Safety instructions ......................................................................................................... 3
2.Operating determinations ............................................................................................... 4
3. Description of the device ............................................................................................... 5
4. Installation....................................................................................................................... 6
4.1Fitting the lamp ............................................................................................................6
4.2 Lamp adjustment .......................................................................................................7
4.3 Installation of an optional lens .................................................................................... 7
4.4 Inserting/Exchanging gobos ...................................................................................... 8
4.5 Connection to the mains ............................................................................................9
4.6 Changing the power supply settings-magetic ballast .................................................9
4.7 Rigging the xture .................................................................................................... 11
4.8 DMX-512 connection/connection between xtures ..................................................14
5.ClubSpot 300 - DMX Protocol,version 1.1 .................................................................. 15
6. Controller operation ..................................................................................................... 17
17
6.2 Remotely controllable functions ...............................................................................
17
7. Stand - alone operation ................................................................................................18
8.Control menu map ......................................................................................................... 19
9. Control menu ............................................................................................................... 21
9.1 Fixture Address ....................................................................................................... 21
9.2 Slave control ...........................................................................................................21
9.3 Fixture informations .................................................................................................. 21
9.4 Personality ...............................................................................................................22
9.5 Lamp On/Off ............................................................................................................23
9.6 Test sequences ........................................................................................................ 23
9.7 Stand-alone setting ................................................................................................. 24
9.8 Reset functions ........................................................................................................24
9.9 Special functions ...................................................................................................... 25
10. Error and information messages .............................................................................. 26
11. Technical specications ............................................................................................ 27
12. Maintenance and cleaning ......................................................................................... 29
ClubSpot 300
Page 3
3
CAUTION!
Keep this device away from rain and moisture!
Unplug mains lead before opening the housing!
FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY
BEFORE YOU INITIAL START - UP!
1. Safety instructions
Every person involved with installation and maintenance of this device have to:
- be qualiled
- follow the instructions of this manual
CAUTION!
Be careful with your operations.
With a high voltage you can suffer
a dangerous electric shock when touching the wires!
This device has left our premises in absolutely perfect condition. In order to maintain this condition and to en­sure a safe operation, it is absolutely necessary for the user to follow the safety instructions and warning notes written in this manual.
Important:
The manufacturer will not accept liability for any resulting damages caused by the non-observance of this
manual or any unauthorized modication to the device.
Please consider that damages caused by manual modications to the device are not subject to warranty.
Never let the power-cord come into contact with other cables! Handle the power-cord and all connections with the mains with particular caution!
Make sure that the available voltage is not higher than stated on the rear panel.
Always plug in the power plug least. Make sure that the power switch is set to OFF-position before you connect the device to the mains. The power-plug has to be accessable after installing the device.
Make sure that the power cord is never crimped or damaged by sharp edges. Check the device and the power­cord from time to time.
Always disconnect from the mains, when the device is not in use or before cleaning it. Only handle the power­cord by the plug. Never pull out the plug by tugging the power-cord.
This device falls under protection class I. Therefore it is essential to connect the yellow/green conductor to earth.
The electric connection, repairs and servicing must be carried out by a qualied employee.
Do not connect this device to a dimmer pack.
Do not switch the xture on and off in short intervals as this would reduce the lamp’s life.
During the initial start-up some smoke or smell may arise. This is a normal process and does not necessarily mean that the device is defective.
Do not touch the device’s housing bare hands during its operation (housing becomes hot)!
For replacement use lamps and fuses of same type and rating only.
CAUTION ! EYEDAMAGES !
Avoid looking directly into the light source
(meant especially for epileptics) !
Page 4
4
2.Operating determinations
This device is a moving-head spot for creating decorative effects and was designed for indoor use only.
If the device has been exposed to drastic temperature uctuation (e.g. after transportation), do not switch it on
immediately. The arising condensation water might damage your device. Leave the device switched off until it has reached room temperature.
Never run the device without lamp!
Do not shake the device. Avoid brute force when installing or operating the device.
Never lift the xture by holding it at the projector-head, as the mechanics may be damaged. Always hold the xture at the transport handles.
When choosing the installation spot, please make sure that the device is not exposed to extreme heat, moisture or dust. There should not be any cables lying around. You endanger your own and the safety of others!
The minimum distance between light-output and the illuminated surface must be more than 1.3 meters.
Make sure that the area below the installation place is blocked when rigging, derigging or servicing the x­ture.
Always x the xture with an appropriate safety rope. Fix the safety rope at the correct holes only.
Only operate the xture after having checked that the housing is rmly closed and all screws are tightly fas-
tened.
The lamp must never be ignited if the objective-lens or any housing-cover is open, as discharge lamps may explose and emit a high ultraviolet radiation, which may cause burns.
The maximum ambient temperature must never be exceeded. Otherwise, the lamp is switched off and the
xture is out of operation for 5 minutes.
CAUTION!
The lens has to be replaced when it is obviously damaged,
so that its function is impaired, e. g. due to cracks or deep scratches!
Operate the device only after having familiarized with its functions. Do not permit operation by persons not
qualied for operating the device. Most damages are the result of unprofessional operation!
CAUTION!
The lamp has to be replaced when it is damaged
or deformed due to the heat!
Please use the original packaging if the device is to be transported.
Please consider that unauthorized modications on the device are forbidden due to safety reasons!
If this device will be operated in any way different to the one described in this manual, the product may suffer damages and the guarantee becomes void. Furthermore, any other operation may lead to dangers like short­circuit, burns, electric shock, burns due to ultraviolet radiation, lamp explosion, crash etc.
Page 5
5
3. Description of the ClubSpot 300 CT
1 - Top cover of the head 2 - Base 3 - Yoke 4 - Handle
Rear panel: 5 - Power switch 6 - Fuse holder
7 - Power cord 8 - 3-pin DMX input 9 - 3-pin DMX output
Front panel: 10 - Display 11 - Mode-button 12 - Enter-button 13 - Up-button 14 - Down-button
Page 6
6
4. Installation
4.1Fitting the lamp
DANGER !
Install the lamps with the device switched off only.
Unplug from mains before !
To insert the lamp , open the top cover of the projector head by loosening the 4 screws on the cover.
Then open the small lamp cover by loosening 3 fastening screws (see the drawing).
If changing the lamp, remove the old lamp from the socket. Insert the lamp to the socket. Do not install a lamp with a higher wattage! A lamp like this generates temperatures the device is not designed for. Damages caused by non-observance are not subject to warranty. Please follow the lamp manufacturer‘s no­tes! Do not touch the glass bulb with bare hands during the installation! Make sure that the lamp is installed tightly into the lampholder system. Adjust the optimal distance 1-1.5 mm from the lens by turning the screw “A” (see the drawings “Lamp adjust-
ment” below) on the rear panel of the head.
Then close the small lamp cover by tighten 3 fastening screws again. Reclose the top cover of the head and tighten the 4 fastening screws. Before striking the lamp, reset the “LAti/rSEt” and “LASt/rSEt”counters in the “InFO” menu on the control panel, by pressing the “Up” and “Down” buttons in one time and then conrming with the “Enter”-button.
Do not operate this xture with opened housing-cover!
Top cover
Lamp
Fastening screws
Lamp cover
Fastening screws
Page 7
7
4.2 Lamp adjustment
The lampholder is aligned at the factory. Due to differences between lamps, ne adjustment may improve light
performance. Strike the lamp, cancel all effects, open the shutter and set the dimmer intensity onto 100 % and focus the light
on a at surface (wall) or use function “LAAd” in the Special functions . As the optimum distance of the lamp from lens was adjusted during the installing or changing the lamp (by turning the screw “A”), it is necessary to adjust only the second position by turning the screw “B”, in order to center the hot-spot (the brightest part of the beam). If the hot spot seems to be too bright, you can lower its intensity by moving the lamp closer to the reector. Do
so by turning the srew “A” until the light is evenly distributed.
If the light on the edge seems to be brighter as in the center, the lamp is too close at the reector. In this case, you need to move the lamp away from the reector until the light is evenly distributed and the beam appears
bright enough.
4.3 Installation of an optional lens
The device is delivered with a 15°-standard lens. If you wish to insert an optional 12° or 18°-lens (it is not the standard part of delivery), please follow the instructions below:
Optional 12°-lens:
Remove the xation-ring of the 15°-lens with an appropriate tool. Remove the lens. Install the optional 12°-lens and x it with the xation-ring.
Incorrect
optimum distance 1-1.5 mm
Correct
rear panel of the moving head
Screw "B"
Screw "A"
15°- lens
12°- lens
Page 8
8
Optional 18°-lens:
Unscrew the knurled-head screw on the plate of the light-output. Install the optional 18°-lens and x it with the
knurled-head screw.
4.4 Inserting/Exchanging gobos
DANGER!
Install the colours gobos with the device switched off only.
Unplug from mains before!
It is possible to change 2 gobos on the static gobo wheel.Open the top cover of the head by loosening the 4 fastening screws on the top cover. Remove the xation-ring with an appropriate tool. Remove the gobo and insert the new gobo. Press the xati­on-ring together and insert it in the front of the gobo.
standard 15°lens
18°lens
18°lens
screw
Page 9
9
4.5 Connection to the mains
Verify the power supply settings before applying power!
If you wish to change the power supply settings,see the chapter below.
Connect the xture to the mains with the enclosed power plug.If you need to install other power plug on the power cable,follow the identication table below.
The earth has to be connected!
Do not connect the xture to a dimmer system!
The occupation of the connection-cables is as follows:
Cable (EU) Cable (US) Pin International
Brown Black Live L
Light blue White Neutral N
Yellow/Green Green Earth
4.6 Changing the power supply settings-magetic ballast
Both the transformer and the ballast must be connected correctly for the local AC voltage and frequency. The wrong settings can cause poor performance or demage of the moving head.The factory settings are printed next to the power switch.
If you want to change the power supply settings,follow the instructions:
1.Disconnect the xture from AC power.
2.Remove the 2 top base covers by loosening 16 screws.
3.Move the wire 1 on the transformer connection block to the position according to the desired voltage.
4.Move the wires 2 and 3 on the ballast connection block to the position according to the desired frequency
(voltage).
5.Close the base before applying AC power.
Examples:
EU-version:
Page 10
10
US-version:
Page 11
11
4.7 Rigging the xture
DANGER TO LIFE!
Please consider the respective national norms during the installation!
The installation must only be carried out by an authorized distributor!
The installation of the projector has to be built and constructed in a way that it can hold 10 times the weight for 1 hour without any harming deformation.
The installation must always be secured with a secondary safety attachment, e.g. an appropriate catch net. This secondary safety attachment must be constructed in a way that no part of the installation can fall down if the main attachment fails.
When rigging, derigging or servicing the xture staying in the area below the installation place, on bridges,
under high working places and other endangered areas is forbidden.
The operator has to make sure that safety-relating and machine-technical installations are approved by an expert
before taking into operation for the rst time and after changes before taking into operation another time.
The operator has to make sure that safety-relating and machine-technical installations are approved by an expert after every four year in the course of an acceptance test.
The operator has to make sure that safety-relating and machine-technical installations are approved by a skilled person once a year.
The projector should be installed outside areas where persons may walk by or be seated.
IMPORTANT! OVERHEAD RIGGING REQUIRES EXTENSIVE EXPERIENCE, including (but not limited to)
calculating working load limits, installation material being used, and periodic safety inspection of all installation
material and the projector. If you lack these qualications, do not attempt the installation yourself, but instead use
a professional structural rigger. Improper installation can result in bodily injury and.or damage to property.
The projector has to be installed out of the reach of people.
If the projector shall be lowered from the ceiling or high joists, professional trussing systems have to be used.
The projector must never be xed swinging freely in the room.
Caution: Projectors may cause severe injuries when crashing down! If you have doubts concerning the safety of a possible installation, do NOT install the projector!
Before rigging make sure that the installation area can hold a minimum point load of 10 times the projector’s
weight.
Danger of re !
When installing the device, make sure there is no highly inammable
material (decoration articles, etc.) in between a distance of min. 0.7 m.
CAUTION!
Use 2 appropriate clamps to rig the xture on the truss.
Follow the instructions mentioned at the bottom of the base.
Make sure that the device is xed properly! Ensure that the
structure (truss)to which you are attaching the xtures is secure.
The projector can be placed directly on the stage oor or rigged in any orientation on a truss without altering
its operation characteristics .
Page 12
12
You can x the xture on a truss via 2 Omega holders or using the mounting plate(it is not the standard part of delivery) or screw the clamps directly to the 2 holes (5) in the base. For overhead use, always install a safety-rope that can hold at least 10 times the weight of the xture. You must
only use safety-ropes with screw-on carabines. Pull the safety-rope through the two apertures on the bottom of
the base and over the trussing system etc. Insert the end in the carabine and tighten the xation screw.
Fixation via the omega holders
1.Bolt each clamp (1) to the omega holder (4) with M12 bolt and lock nut through the hole in the holder.
2.Fasten the omega holders on the bottom of the base by inserting both quick-lock fasteners (3) into the holes
of the base and tighten fully clockwise.
3.Fasten the safety-rope (2) through the two apertures on the bottom of the base and over the trussing sys­tem.
When installing xtures side-by-side,
avoid illuminating one xture with another!
DANGER TO LIFE!
Before taking into operation for the rst time,the installation has to be ap
-
proved by an expert!
1-Clamp 2-Safety-rope 3-Quick-lock fastener 4-Omega holder 5-Mounting holes 2x M10
Page 13
13
Fixation via a mounting plate
1. Screw 2 clamps (1) to the mounting plate (4) with M12 bolts and lock nuts through the holes in the mounting plate (4).
2. Insert the 4 quick-lock fasteners (3) into the holes on the bottom of the base and tighten fully clockwise.
3. Fasten the safety-rope (2) through the two apertures on the bottom of the base and over the trussing sys-
tem.
1-Clamp 2-Safety-rope 3-Quick-lock fasteners 4-Mounting plate
Page 14
14
4.8 DMX-512 connection/connection between xtures
The xture is equipped with 3-pin XLR sockets for DMX input and output. Only use a shielded twisted-pair cable designed for RS-485 and 3-pin XLR-plugs and connectors in order to connect the controller with the xture or one xture with another.
DMX - output DMX-input
XLR mounting-sockets (rear view): XLR mounting-plugs (rear view):
If you are using the standard DMX controllers, you can connect the DMX output of the controller directly with the DMX input of the rst xture in the DMX-chain. If you wish to connect DMX-controllers with other XLR-out­puts, you need to use adapter-cables.
Building a serial DMX-chain:
Connect the DMX-output of the rst xture in the DMX-chain with the DMX-input of the next xture. Always connect one output with the input of the next xture until all xtures are connected.
Caution: At the last xture, the DMX-cable has to be terminated with a terminator. Solder a 120 Ω resistor between Signal (–) and Signal (+) into a 3-pin XLR-plug and plug it in the DMX-output of the last xture.
Building a master/slave-chain:
Connect the DMX-output of the master xture in the data-chain with the DMX-input of the rst slave. Always connect output with the input of the next slave until all slaves are connected (up to 9 xtures). Caution:It’s necessary to insert the XLR termination plug (with 120 Ohm) into the input of the master xture and into the output of the last slave xture in the link in order to ensure proper transmission on the data link.
Master/slave operation
Controller operation
1 - Ground 2 - Signal (-) 3 - Signal (+)
1 - Ground 2 - Signal (-) 3 - Signal (+)
Page 15
15
5.ClubSpot 300 - DMX Protocol,version 1.1
Mode 1
Channel
Mode 2
Channel
8 bit
Channel
DMX
Value
Function
Type of control
1 1 1 0-255
Pan
Coarse control of pan movement
proportional
3 2 - 0-255
Pan Fine
Fine control of pan movement
proportional
2 3 2 0-255
Tilt
Coarse control of tilt movement
proportional
4 4 - 0-255
Tilt ne
Fine control of tilt movement
proportional
5 5 3
0 1-249 250-255
Speed of Pan/Tilt movement
Max. speed (tracking mode) From max.speed to min.speed (vector mode) Max.speed (tracking mode),black-out while colour
changing or pan/tilt moving
step
proportional
step
6 6 4
0-127 128-139 140-229 230-239 240-255
Lamp On/Off,reset,speed control of fan
From max.speed of fans to min. speed of fans Lamp On,reset No function Lamp Off after 3 sec. No function
proportional
step step step step
7 7 5
0 10 21 32 42 53 64 74 85 96 106 117 128-189 190-193 194-255
Colours
Continual positioning
Open/White Turquoise Deep red Cyan
UV lter
Magenta Light blue Yellow Green Pink Blue Red Forwards rainbow effect from fast to slow No rotation Backwards rainbow effect from slow to fast
proportional proportional proportional proportional proportional proportional proportional proportional proportional proportional proportional proportional proportional
step
proportional
8 8 6 No function
9 9 7
0-95 96-159
160-255
160-167 168-175 176-183 184-191 192-199 200-207 208-215 216-223 224-231 232-239 240-247 248-255
Effect wheel
Open position (hole)
3-facet rotating prism
Prism/gobo macros
Macro 1 Macro 2 Macro 3 Macro 4 Macro 5 Macro 6 Macro 7 Macro 8 Macro 9 Macro 10 Macro 11 Macro 12
step step
step step step step step step step step step step step step
Page 16
16
10 10 8
0 1-126 127-128 129-255
3-facet prism rotation control
No rotation Forward rotation from fast to slow No rotation Backward rotation from slow to fast
step
proportional
step
proportional
11 11 9
0-31 32-63 64-95 96-127 128-159 160-191 192-223 224-255
Rotating gobo selection
Open Gobo 1 Gobo 2 Gobo 3 Gobo 4 Gobo 5 Gobo 6 Forward gobo wheel rotation from slow to fast
step step step step step step step
proportional
12 12 10
0-127 128-190 191-192 193-255
Gobo indexing and rotation
Gobo indexing Forwards gobo rotation from fast to slow No rotation Backwards gobo rotation from slow to fast
proportional proportional
step
proportional
13 13 11 No function
14 14 12
0-255
Focus
Continuous adjustment from far to near proportional
15 15 13
0-31 32-63 64-95 96-127 128-143 144-159 160-191 192-223 224-255
Shutter,Strobe
Shutter closed Shutter open Strobe-effect from slow to fast Shutter open Closing pulses from slow to fast Opening pulses from fast to slow Shutter open Random strobe effects from slow to fast Shutter open
step step
proportional
step proportional proportional
step proportional
step
16 16 14
0-255
Dimmer intensity
Dimmer from closed to 100% light output proportional
Page 17
17
6. Controller operation
The xtures are individually addressed on a data link and connected to the controller.The xtures respond to
the DMX signal from the controller.
6.1 DMX addressing
The control panel on the front panel of the xture allows you to assign the DMX xture address, which is dened as the rst channel from which the ClubSpot 300 will respond to the controller. If you set, for example, the address to channel 5, the ClubSpot 300 will use the channel 5 to 20 for control (if 16-bit mode is selected). Please, be sure that you don’t have any overlapping channels in order to control each ClubSpot 300 correctly and independently from any other xture on the DMX data link.
If two, three or more ClubSpot 300 are addressed similarly, they will work similarly.
For address setting, please refer to the instructions under "Addressing"(menu "A001").
Controlling:
After having addressed all ClubSpot 300 , you may now start operating these via your lighting controller. Note:After switching on, the ClubSpot 300 will automatically detect whether DMX 512 data is received or not.If there is no data received at the DMX-input, the display will start to ash "A001" with actually set address. This situation can occur if:
- the 3 PIN XLR plug (cable with DMX signal from controller) is not connected with the input of the ClubSpot
300
- the controller is switched off or defective, the cable or connector is defective or the signal wires are swap in the input connector.
Note:It’s necessary to insert the XLR termination plug (with 120 Ohm) to the last xture in the link in order to
ensure proper transmission on the DMX data link.
6.2 Remotely controllable functions
Lamp
A relay inside of the ClubSpot 300 allows you to switch on and off the lamp via the control panel or via your DMX-controller without affecting the rest of the lighting.
To switch On/Off the lamp, please refer to "Lamp On/Off " (menu LAMP). Note:It is also important to note, that the discharge lamp is cold restrike types, that means, that they have to be
cold before re-striking. For this reason, you have to wait 5 minutes (max. speed of fan must be adjusted) after
having switched Off the lamp before you can switch it back On again. If you try to switch On the lamp within 5 minutes after having switched it Off, the ClubSpot 300 will store this information and automatically ignite the lamp when the 5 minutes period has expired. The message "HEAt" will appear on the control panel display of the ClubSpot 300. If the ignition of the lamp is seven times unsuccessful, on the display will appear "LA.Er", meaning that the lamp could be damaged or even missed, or there could be a failure on the ignitor or ballast.
Colour wheel
The ClubSpot 300 CT features a colour-wheel with 12 colour positions - 11 of these with dichroic colors and the last one open. The wheel can be positioned between two adjacent colors in any position. It is also possible to rotate the color-wheel continuously at different speeds - the so-called „Rainbow effect“ is created.
Gobo wheel
The rotating gobo-wheel includes 4 metal gobos, 1 glass gobo and 1 multicolour dichroic gobo rotating in both directions, indexable, rotating gobo wheel cont. rotation slow to fast. The multicolour dichroic gobo can be combined with the color-wheel especially with cyan, magenta and yellow colours in order to obtain several different multicolour beams.
3-facet rotating prism
3-facet prism rotating in both directions at different speeds.
Focus
Motorized focus enables the beam to be focused anywhere on the stage.
Page 18
18
Dimmer/Shutter/Strobe
Smooth 0 - 100 % dimming is provided by the combined mechanical dimmer/shutter unit. This unit may also be used for strobe effect .
7. Stand - alone operation
The xtures on a data link are not connected to the controller but can execute pre-set programs which can be different for every xture.To set the program to be played,see the "Stand-alone setting" ( menu "St.AL."). "Stand-alone operation" can be applied to the single xture (the xture may be set to the master /slave mode or controller mode ) or to multiple xtures operating synchronously. Synchronous operation of multiple xtures requires that they must be connected on a data link and one of them is set as a master (master mode) and the rest as the slaves (slave mode).The slaves are assigned to SLA1­SLA9 and on the certain slave address can be connected only one xture.To set the xture as the master or slave , see the "Addressing" (menu "A001").
If the master xture runs a reset,switches On/Off the lamp or plays test(program) ,all slaves will execute these acts too (e.g. if the master xture has switched the lamp off,no slaves can switch the lamp on)!
The master xture starts simultaneous program start in the other slave xtures.All xtures have a denite, syn­chronized starting point when playing back their programs.The number of running program is the same in all
slaves and depends on the master's choice (menu "St.AL." ).Every xture runs its program repeatedly ,starting
the program step No.1 when requested by the master . For example:
If the slave xture has a shorter program length, it will continously repeat its program until the master xture nishes its own program and restarts its program running (slave 1- prog.step 3 will not be nished). If the slave xture has a longer program length, it will restart at prog. step 1 before it completes all its
prog.steps
(slave 2 - prog.step 5 will not be played)- see the picture bellow.
Note:Disconect the xtures from the DMX controller before master/slave operating ,otherwise data collisions can occur and the xtures will not work properly!
Starting point
Restart
Page 19
19
8.Control menu map
Default settings=Bold print
A001
dM.Ad. 001 : 503 MA.SL. d.AbL MASt. SLA.1 : SLA.9
SL.Ct.
InFo
Po.ti. totl rSEt La.ti. totl rSEt LA.St. totl rSEt
Hi.tE. totl rSEt
tEMP.
DM.In. Pan (0-255) : dim (0-255) VErS.
PErS. r.PAn (On,Off) r.tilt (On,Off) 16br Mod1 Mod2 8bit LA.Pr. LA.Au.(On,Off) d.L.OF.(On,Off) dM.On (On,Off) dM.OF.(On,Off)
En.Sn.(On,Off) dISP. turn (On,Off) d.On (On,Off) d.Int.(20...100)
bL.Co. (On,Off) FEEd. (On,Off) FAn.S. (Auto,HIGH,rEG,LoOF,LoHI) dF.SE.
Page 20
20
LAMP (On,Off)
tESt Mod 1 Pan (0-255) tilt (0-255)
Foc. Go... Mod 2
St.AL. Auto
Off
tESt PrG.1 PrG.2 PrG.3 PLAY tESt PrG.1 PrG.2 PrG.3 Edit PrG.1 PrG.2 PrG.3 St.01 : St.99 Pan (0-255) : S.tim.(0.1-25.5) (s) COPY
rESE.
SPEC. MAnu. Pan (Pan1,Pan2,Pan3) : dimr (dim0...dim4,dimC) LA.Ad. PAn (0-255) tilt (0-255) Foc (0-255)
CodE AdJ. Pan (0-255) : F.CAL Colo. (0-255) EFFE.(0-255) r.Gob. (0-255) G.rot. (0-255) A.rES.
Page 21
21
9. Control menu
The control panel situated on the front panel of the base offers several features. You can simply set the DMX address,read the number of the lamp or unit hours, switch On and Off the lamp, run test, make a reset and also
use many functions for setting xture behaviour.
Control elements on the control board:
[MODE] button-leaves menu without saving changes.
[ENTER] button- enters menu,conrms adjusted values and leaves menu.
[UP] button and[DOWN] button- moves between menu items on the the same level, sets values.
After switching the xture on,the display shows the initial screen:
Use [UP],[DOWN] to browse through the menu. To select a function or submenu,press [ENTER].
9.1 Fixture Address
Use this menu to set the DMX address of the xture or set the xture as a Master (Slave).
dM.Ad. --- DMX addressing.Select this submenu to set DMX start address.
MA.SL. --- Master/slave addressing.Select this submenu to set the xture as a Master or Slave (Slave1- Slave 9).Option "d.AbL" deactivates master/slave setting.
9.2 Slave control
This function allows you to control the slaves from the master's control panel in a master/slave operation.
Select this function from the main menu and press [ENTER].Browse the list of all connected slaves ("SL.C.1"
- "SL.C.9") by pressing [UP] or [DOWN].Select the desired slave and press [ENTER]-button.The matching slave
control panel is available from the master control panel.
Note:This function is available from the master xture only.
9.3 Fixture informations
Use this menu to read an useful information about the xture.
Po.ti. ---Power on time.Select this submenu to read the number of operation hours. totL --- The function shows the total number of the operation hours since the ClubSpot 300 has been fabricated. rSEt --- The function shows the number of the operation hours that the ClubSpot 300 has been powered on since the counter was last reset.In order to reset this counter to 0 you have to hold [UP] and[DOWN ] and press the [ENTER].
La.ti. --- Lamp on time.Select this submenu to read the number of the operation hours with the lamp on.
Page 22
22
totL --- The function shows the total number of the operation hours with the lamp on since the ClubSpot 300 has been fabricated. rSEt --- The function shows the number of the operation hours with the lamp on that the ClubSpot 300 has been powered on since the counter was last reset.In order to reset this counter to 0 you have to hold [UP] and[DOWN ] and press the [ENTER].
LA.St. --- Lamp strikes.Select this submenu to read the total number of the lamp strikes. totL --- The function shows the total number of the lamp strikes since the ClubSpot 300
has been fabricated. rSEt --- The function shows the number of the lamp strikes since the counter was last reset.In order to reset this counter to 0 you have to hold [UP] and[DOWN ] and press [ENTER].
Hi.tE ---Max.xture head temperature.Select this submenu to read the max. xture head temperatures (°C).
totL - The function shows the max.temperature of the head inside since the ClubSpot 300 has been fabricated. rSEt - The function shows the maximum temperature of the head inside since the counter was last reset.In order to reset the counter to 0 you have to hold [UP] and[DOWN ] and press the [ENTER].
tEMP ---Current xture head temperature.Select this submenu to read the current xture head temperature (°C). Temperatures below 70°C are not critical. 70° C and more lead to the lamp being switched off.Please
note that the outside temperature should not exceed 45° C.
DM.In.--- Readout of DMX values.Select this function to read DMX values (0-255) of each channel received by the xture.
PAn a coarse pan movement EFFE. a prism F.PAn a ne pan movement Prot. a prism rotation tilt a coarse tilt movement r.Gob. a rotating gobo wheel F.tilt a ne tilt movement G.rot. a gobo rotation SpEd a pan/tilt speed Foc. a dimmer Func. a special function Stro. a shutter,strobe Colo a colour wheel dimr a dimmer
VErS. --- Software version.Select this function to read the software version of the display module.
9.4 Personality
Use this menu to modify ClubSpot 300 operating behavior.
r.PAn --- Pan reverse.Select this function to invert the pan movement.
r.tilt --- Tilt reverse.Select this function to invert the tilt movement.
16b.r. --- 16bit resolution.By this function you can adjust the 16-bit movement resolution (Mod1, Mod2) or
8-bit resolution (8bit).
LA.Pr. --- Lamp presetting.Select this menu to change the lamp "behaviour". LA.Au. --- Select this function to turn the lamp on automatically after switching the
xture on.
d.L.OF. --- Select this function to switch off the lamp via DMX. dM.On --- This function allows you to strike the lamp automatically after 26 seconds if DMX
signal is present on the data link.If the ignition is unsuccessfull (e.g.lamp is too hot),the xture will try to ignite the lamp after next 26 s.This process will repeat until the lamp lights.
dM.OF. --- This function allows you to switch Off the lamp automatically after 2 minutes if DMX signal is missing on the data link.
Page 23
23
En.Sn. --- Switching on/of the lamp light sensor.Select this function to switch the lamp light sensor on or off.The option"On" is for the standard operation. Important: The option"Off" is for "emergency operation" only if the lamp light sensor is defective and you will wait for a service intervertion! If the lamp light sensor is switched off and at switching the lamp on the electron-
ics will still try to ignite the lamp until it shines (even when the lamp is damaged or absent), on this
account some electronics parts could be damaged!
DiSP. --- Display adjusting.This function allows you to change the display settings. turn --- Select this function to turn the display by 180°. d.On --- This function allows you to keep the display on or to turn off automatically 2 minutes after last pressing any button on the control panel. d.Int. --- Select this function to adjust the display intensity (20-min.,100-max.).
bL.Co. --- Blackout during movement correction.Select this function to enable the blackout during the
head movement correction (if the moving head lost its right pan/tilt position for a short moment).
FEEd --- Pan/Tilt feedback.This function allows to return the mowing head to the required pan/tilt position after
changing the position by external force (e.g.by stroke).
Be careful, the Pan/Tilt Feedback OFF is not the standard operation and the head of the xture can be de- maged! Note: If the feedback was switched off ,the pan/tilt-position is changed by an external force and the feedback is switched on again,the moving head might not to be synchronized with the DMX signal.You have to make a reset in order to synchronize the moving head with the DMX signal.
Fan.S. --- Fan speed operating modes.By using this function you can choose 3 types of the fans speed op­erating modes. Auto --- The fan automatically raises its speed in order to control inside temperature of the head.
HIGH --- The cooling fan works on max. speed (max. cooling). reg --- This mode is similar to "Auto" but the initial level of the fan speed can be adjusted by
DMX valus on the channel 6 (see DMX protocol).
Lo.OF. --- The fan keeps the adjusted low speed until the temperature exceeds max. inside
temperature of the xture, then the ClubSpot 300 automatically switches off the lamp.
Lo.HI. --- The fan keeps the adjusted low speed until the temperature exceeds max. inside
temperature of the xture, then the ClubSpot 300 automatically switches from low to high the
fan speed.
dF.SE. --- Default Settings .Select this option to reset all xture personalities to the default values.
9.5 Lamp On/Off
Use this option in order to switch on/off the lamp.It is also important to note, that the lamp is cold restrike type, that means, that it has to be cold before striking.
9.6 Test sequences
Use this menu to to run a special demo-test sequences without an external controller, which will show you some possibilities of using ClubSpot 300. Mod. 1 --- Mode 1. This mode is suitable for projections on the wall, ceiling or ground without any head movement. Mod. 2 --- Mode 2.This mode uses all ClubSpot 300 functions including pan/tilt
movement and therefore is good for a complete introduction of the xture.
Page 24
24
9.7 Stand-alone setting
Use this menu to set options for stand-alone mode as a selection of the playing program,programming and modifying current programs.
Auto --- Presetting playback.This function allows you to select the program which will be played in the stand-
alone mode after switching the xture on.Selected program will be played continuously in a loop.
d.Abl --- The option disables "Auto" function. tESt --- The option will start built-in test program. PrG. 1 --- The option will start created program No.1 PrG. 2 --- The option will start created program No. 2 PrG. 3 --- The option will start created program No. 3
Note:If the xture operates in the controller mode ( DMX controller is connected) and any program from this menu is selected ,in this case the xture will not respond to the DMX controller after switching on and will play
selected program. PLAY --- Playing program.Select this menu to run a bilt-in program or the 3 freely-programmable programs in a loop. tESt --- The option starts built-in test program. PrG.1 --- The option starts created program No. 1 PrG.2 --- The option starts created program No. 2 PrG. 2 --- The option starts created program No. 3 Select the program you wish and press [ENTER].The selected program starts running.By Pressing [ENTER] again is possible to pause the program running.
Edit --- Editing program.Select this menu to edit or create the program.The ClubSpot 300 has one built­in program and the 3 free programs,each up to 99 steps.Each program step has a step time.Step time-the time,during which effects last in the current step.
If the xture is set as a master ,then you may edit any program in the slaves.You can't edit programs on the slave xtures from their control panels if the master xture is switched on and connected to the slaves (editing is possible by the master control panel only).
Procedure:
1. Press [UP] or [DOWN] to select the program you want to edit ("PrG.1" - "PrG.3") and press [ENTER].
2. Press [UP] or [DOWN] to select the desired xture ("MASt." - "SLA.9") and press [ENTER]-button.
3. Press [UP] or [DOWN] to select the desired program step ("St.01" - "St.99") and press [ENTER]-button.
4 Press [UP] or [DOWN] to select the desired item and press [ENTER]-button.Now you can edit by [UP] o r
[DOWN] buttons the DMX value (0-255) for selected item:
P.End. - a total number of the program steps (value 1-99).This value you must set before start
programming(e.g. if you want to create program with the 10 steps,set P.End=10).
PAn a coarse pan movement EFFE. a prism tilt a coarse tilt movement Prot. a prism rotation SpEd a pan/tilt speed t r.Gob. a rotating gobo wheel Func. a special function G.rot. a gobo rotation Colo a colour wheel Foc. a dimmer Stro. a shutter,strobe dimr a dimmer S.tim. a step time,value 0,1-25,5 seconds COPY. - copying the current prog. step to the next prog. step .If the last prog.step is copied to the next prog. step ,parameter "P.End" is increased about one by itself (except step 99).
5. Press [ENTER]-button to conrm adjusted value .
6. Press [MODE]-button,select next prog. step and repeat this procedure (steps 4 - 6).
9.8 Reset functions
This option enables the ClubSpot 300 to index all effects (functions) and return to their standard positions.
Page 25
25
9.9 Special functions
Use this menu for special services like adjusting lamp or adjusting effects.
MAnu. --- Manual control of the effects..Select this menu to call up presetted positions of the effects.
LA.Ad. --- Lamp adjustment.This function can be used when you make the ne adjustment of the lamp.If you
select this function,all effects will be canceled,shutter will be opened and the dimmer intensity will be set onto 100%.By using the options "PAn, tilt, Foc" you can focus the light on a at surface (wall) and perform the ne lamp adjustment.
CodE --- Code.This function contains identication hexadecimal code (0000-FFFF) for the xture, which is used for the master/slave operation.
AdJ. --- Effect adjustment.By this function you can calibrate and adjust the effects to their standard/right
positions.Disconect the DMX controller from the xture and select "AdJ." menu.The display shows step by step effects by which you can adjust the xture to the required position before the function calibration(DMX controller must be disconnected) . When the positioning is nished ,select "F.CAL." and press [ENTER]:
1. Calibration via the control board
Disconnect DMX controller from the xture.Press [ENTER] and use [UP] and [DOWN] in order to display the
following items: "Colo.,EFFE,rGob.,G.rot" for very smooth function calibration. Select one of them, press [ENTER] and use the [UP] and [DOWN] in order to adjust their right value from 0 to 255. Then press [ENTER]
to conrm or [MODE] to cancel and return to the menu. This can be repeated for each calibration parameter if it is required. When the calibration is nished, it is necessary to use the "A.rES" function in order to write the calibration values to the memory (EPROM) and to make a reset in order to check the newly adjusted positions of the colour and gobo wheels. When the reset of the xture is nished, the display will show the "F.CAL" mes-
sage. Press [ENTER] to repeat the calibration or [MODE] to return to the "AdJ." menu.
2. Calibration via the external controller
Connect the DMX controller to the xture, press [ENTER] and the [UP] and [DOWN] buttons in order to display
the following items: "Colo.,EFFE,rGob.,G.rot".Select one of them and press [ENTER]. Now you can calibrate this effect by your controller. The DMX calibration protocol is described below. DMX calibration protocol:
Effect pan/tilt resolution=16bit (Mode1,Mode2)
Colour wheel(smooth microstep movement) channel 1 No function channel 2 Effect (smooth microstep movement) channel 3 Rotating gobo wheel (smooth microstep movement) channel 4 Gobo rotation (smooth microstep movement) channel 5 No function channel 6 Standard DMX protocol: Colour wheel channel 7 : : Dimmer channel 16
After having calibrated required effects, press [ENTER] to conrm (or [MODE] to cancel and return to the menu without reset by the "A.rES." function) and use the "A.rES." function in order to write the calibration values to the memory (EEPROM) and to make a reset in order to check the new adjusted positions of the colour and
gobo wheels .
Page 26
26
10. Error and information messages
HEAt
This message appears if you try to switch on the lamp within 5 minutes after having switched it off (the lamp is too hot). The message will appear on the display if the lamp doesn't ignite within 28 seconds. The ClubSpot
300 will store this information and automatically ignite the lamp when the 5 minutes period has expired.
Caution: The message is disabled if the lamp light sensor (function "En.Sn.") is switched Off (only if the lamp
was turned Off and On within 5 minutes,the message "HEAt" will appear).
LA.Er.
The ignition of the lamp is seven times unsuccessful (the "HEAt" message appeared six times before), and the display shows "LA.Er ", meaning that the lamp could be damaged or even missed, the xture is overheated (this can occur if the ambient temperature is 40° C or more) or there could be a failure on the ignitor or ballast.
Please place or replace the lamp, check the ambient temperature or contact your dealer if the situation was not caused by the lamp.
Caution: The message is disabled if the lamp light sensor (function "En.Sn.") is switched Off.
Mb.Er.
This messsage informs you that the main PCB does not communicate correctly with the Control Board.
Co.Er. (color wheel error)
This messsage will appear after the reset of the xture if the magnetic-indexing circuit malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or its driver circuit on the main PCB). The color-
wheel is not located in the default position after the reset.
r.GEr. (rotating gobo wheel error)
This message will appear after the reset of the xture if the magnetic-indexing circuit malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or its driver circuit on the main PCB). The rotating gobo
wheel is not located in the default position after the reset.
iGEr. (rotating gobo indexing error)
This message will appear after the reset of the xture if the magnetic-indexing circuit malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or its driver circuit on the main PCB). The rotating gobo
is not located in the default position after the reset.
Ft.Er.
This error message informs you that the xture was overheated (occured if the ambient temperature is 40° C or more) and that the relay switched off the lamp.
Fr.Er.
This message will appear if the frequency of the main is not standard 50 or 60 Hz.This message can appear as
a result of the interference during the lamp starting (if the lamp or igniter is old) or as a result of the interference
by neighbouring devices. In these cases the message does not affect the xture operating!
Sn.Er.
This message appears if the lamp light sensor is failed.
PoEr
This message will appear if the xture was shortly disconnect from the main.
PA.Er. (Pan-yoke movement error)
This message will appear after the reset of the xture if the yoke’s magnetic-indexing circuits malfunction (sensors failed or magnet missing) or the stepping motor is defective. (Or its driving IC on the main PCB). The
yoke is not located in the default position after the reset.
ti.Er. (TILT-head movement error)
This message will appear after the reset of the xture if the head’s magnetic-indexing circuit malfunctions (sensor failed or magnet missing) or the stepping motor is defective. (Or its driving IC on the main PCB). The
head is not located in the default position after the reset.
MA.Er.(Master error)
The message informs you that the xture was addressed as a master and DMX signal is connected to its input.Disconnect the DMX controller from xture's input and address the xture as the master again.
Page 27
27
11. Technical specications
Power supply:
EU-model: Voltage:...........................208/230/240V AC, 50/60Hz ~
Fuse:...............................T 3.15@230V
US-model: Voltage:...........................100/120/208/230/240V AC, 50/60Hz ~
Fuse:................................T 6.3A@120V
Power consumption:.........500 VA
Approved lamps:
Osram HSD 250/80,Philips MSD 250/2,Sylvania BA 250/2 SE
Optical System:
- High luminous-efciency parabolic mirror and double condenser system
- Standard 15° focused beam angle
- Optional 12° and 18° lens
- All lenses are anti-reection coated
Colour wheel:
-11 dichroic lters + open
- Colour wheel continuous rotation in both directions (rainbow effect)
Rotating gobo wheel:
- 6 glass gobos (1 effect-glass gobo, 3 black and white gobos,1 multicolour and
1 dichroic gobo)
- Gobo indexing and rotation in both directions at different speeds
- Rotating gobo-wheel cont. rotation
- All rotating gobos are easily replaceable
- Gobo dimensions: outside diameter=26.8mm, thickness=1.1mm, high temperature borooat or better glass, image diameter=22 mm
- Effect-glass gobo: outside diameter=26.8 mm, max.thickness=4mm, high temperature borooat or better glass
-3 black and white gobos and 2 effect-glass gobos are included
Strobe:
- Strobe effect with variable speed (max.10 ashes per second)
- Preprogrammed variable/random strobe and dimmer pulse-effects
Dimmer:
- Smooth dimmer from 0 - 100 %
Prism:
- 3-facet-prism rotating in both directions at different speeds
- Macro-function for rotating gobos/rotating prism combinations
Focus:
- Remotely controllable motorized focus from near to far
Motors:
- 10 high quality stepping-motors controlled by microprocessors
Electronics:
- Addressing,special functions setting,effects calibration via control panel with 4-digit LED display
- Readout xture and lamp usage,receiving DMX values,temperature, etc
- Built-in analyzer for easy fault nding,error messages
- Remotely switching of the lamp
- Bilt-in demo sequences
Page 28
28
- Black-out while head moving or gobo/color changing
- Silent fans cooling,
- Self-resetable thermo-fuse
- Master/slave operation
- Digital serial input DMX-512
- 14 or 16 DMX control channels
Pan/Tilt
- Pan movement range 530°
- Tilt movement range 280°
- 8 or 16 bit movement resolution
- Automatic Pan/Tilt position correction
- Remotely controllable speed of pan/tilt movement for easy programming
- Movement control:tracking and vector
Rigging
-Stands directly on the oor
-Mounts horizontally or vertically with 2 Omega brackets
-2 truss orientation
-Safety chain/cord attachment point
Temperatures
-Maximum ambient temperature : 45° C
-Maximum housing temperature : 80° C
Minimum distances
-Min.distance from ammable surfaces: 0.5m
-Min.distance to lighted object: 1.3m
Weight (net):
EU version: 20.2 kg US version: 24 kg
Dimensions(mm)
240
417
34 9
49 8
398
375
280°
2
6
5
°
2
6
5
Page 29
29
Accessories
- Omega holder (2 pieces)................................99010420
Optional accessories:
- Objective12°...................................................99010201
- Lens-module 18°............................................99010200
- Mounting plate................................................99010292
Beampath:
12. Maintenance and cleaning
It is absolutely essential that the xture is kept clean and that dust, dirt and smoke-uid residues must not build up on or within the xture. Otherwise, the xture‘s light-output will be signicantly reduced. Regular cleaning will not only ensure the maximum light-output, but will also allow the xture to function reliably throughout its life. A soft lint-free cloth moistened with any good glass cleaning uid is recommended, under no circumstances
should alcohol or solvents be used!
DANGER !
Disconnect from the mains before starting any
maintenance work
The front objective lens will require weekly cleaning as smoke-uid tends to building up residues, reducing the
light-output very quickly. The cooling-fans should be cleaned monthly.
Page 30
30
The gobos may be cleaned with a soft brush. The interior of the xture should be cleaned at least annually
using a vacuum-cleaner or an air-jet.
The dichroic colour-lters, the gobo-wheel and the internal lenses should be cleaned monthly.
There are no serviceable parts inside the device except for the lamp and the fuse. Please refer to the instructions under "Fitting/Exchanging the lamp". Maintenance and service operations are only to be carried out by authorized dealers.
Replacing the fuse
If the lamp burns out, the ne-wire fuse of the device might fuse, too. Only replace the fuse by a fuse of same
type and rating.
Before replacing the fuse, unplug mains lead.
Procedure:
1) Unscrew the fuseholder on the rear panel of the base with a tting screwdriver from the housing (anti- clockwise).
2) Remove the old fuse from the fuseholder.
3) Install the new fuse in the fuseholder.
4) Replace the fuseholder in the housing and x it.
Specications are subject to change without notice.
Page 31
31