Robe CitySource 96, CitySource 96W, CitySource 96 WDMX User Manual

Version 1.
5
CitySource 96 (SmartWhite)
2
Table of contents
1. Safety instructions ...................................................................................................................................................... 3
2. Fixture exterior view ................................................................................................................................................... 5
3. Installation .................................................................................................................................................................. 5
3.1 Rigging the fixture ................................................................................................................................................. 5
3.2 Connection to the mains ...................................................................................................................................... 6
3.3 Changing the lens array ........................................................................................................................................ 6
3.4 Installation of the barn-doors and top hat/half top hat ....................................................................................... 8
3.5 DMX 512 connection ............................................................................................................................................ 8
3.6 Master/slave connection ...................................................................................................................................... 9
3.7 Stand-alone operation ........................................................................................................................................ 10
4. CitySource 96 (SmartWhite) - DMX protocol ............................................................................................................ 11
5. Control menu map .................................................................................................................................................... 12
6. Fixture menu ............................................................................................................................................................. 14
6.1 Fixture Address ................................................................................................................................................... 14
6.2 Fixture information ............................................................................................................................................. 15
6.3 Personality .......................................................................................................................................................... 16
6.4 Manual mode ...................................................................................................................................................... 16
6. 5 Test sequences................................................................................................................................................... 17
6.6 Stand-alone setting ............................................................................................................................................. 17
6.7 Special functions ................................................................................................................................................. 18
7. RDM .......................................................................................................................................................................... 20
8. Wireless DMX operation ........................................................................................................................................... 21
9. Error and information messages .............................................................................................................................. 21
10. Technical specifications .......................................................................................................................................... 21
11. Cleaning and maintenance ..................................................................................................................................... 24
12. ChangeLog .............................................................................................................................................................. 24
CitySource 96 (SmartWhite)
3
FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY
BEFORE POWERING OR INSTALLING YOUR CitySource 96 !
Save it for future reference.
This device has left our premises in absolutely perfect condition. In order to maintain this condition and to ensure a safe operation, it is absolutely necessary for the user to follow the safety instructions and warning notes written in this manual.
The manufacturer will not accept liability for any resulting damages caused by the non-observance of this manual or any unauthorized modification to the device.
Please consider that damages caused by manual modifications to the device are not subject to warranty.
1. Safety instructions
DANGEROUS VOLTAGE CONSTITUTING A RISK OF ELECTRIC SHOCK IS PRESENT WITHIN THIS UNIT!
Make sure that the available voltage is not higher than stated on the rear panel of the fixture. This fixture should be operated only from the type of power source indicated on the marking label. If you are not sure of the type of power supplied, consult your authorized distributor or local power company.
Always disconnect the fixture from AC power before cleaning, removing or installing the fuses, or any part.
Do not overload wall outlets and extension cords as this can result in fire or electric shock.
Make sure that the power cord is never crimped or damaged by sharp edges. Check the fixture and the power cord from time to time.
Do not install the unit near naked flames.
During the operation the housing becomes hot (up to 80°C)
Refer servicing to qualified service personnel.
This fixture falls under protection class I. Therefore this fixture has to be connected to a mains socket outlet with a protective earthing connection.
Do not connect this fixture to a dimmer pack.
LED light emission. Risk of eye injury. Do not look straight at the fixture´s LEDs during operation. The intense light beam may damage your eyes.
Keep compustible materials at least 30 cm away from the fixture.
If the fixture has been exposed to drastic temperature fluctuation (e.g. after transportation), do not switch it on immediately. The arising condensation water might damage your device. Leave the device switched off until it has reached room temperature.
Do not shake the fixture. Avoid brute force when installing or operating the fixture.
This fixture was designed for indoor and outdoor use.
CitySource 96 (SmartWhite)
4
When choosing the installation spot, please make sure that the fixture is not exposed to extreme heat or dust.
Avoid using the unit in locations subject to possible impacts.
The fixture body never must be covered with cloth or other materials.
Only operate the fixture after having checked that the housing is firmly closed and all screws are tightly fastened.
Make sure that the area below the installation place is blocked when rigging, derigging or servicing the fixture.
Do not block the front objective LEDs with any object when the fixture is under operation.
The fixture becomes very hot during operation. Allow the fixture to cool approximately 30 minutes prior to manipulate with it.
Operate the fixture only after having familiarized with its functions. Do not permit operation by persons not qualified for operating the fixture. Most damages are the result of unprofessional operation!
Do not attempt to dismantle or modify the unit.
Please consider that unauthorized modifications on the fixture are forbidden due to safety reasons!
Please use the original packaging if the fixture is to be transported.
If this device will be operated in any way different to the one described in this manual, the product may suffer damages and the guarantee becomes void. Furthermore, any other operation may lead to dangers like short­circuit, burns, electric shock etc.
CitySource 96 (SmartWhite)
5
2. Fixture exterior view
Standard version Wireles DMX version
3. Installation
Warning for wireless DMX version of the CitySource96!
The antenna must be instaled on the fixture to keep declared IP rating of the fixture!
3.1 Rigging the fixture
Ensure that the structure (truss) to which you are attaching
the fixture is secure
The fixture can be rigged in any orientation on a truss via the omega holder without altering its operation characteristics. The mounting bracket allows to adjust desired fixture position (0°-360°). The mounting hole in the mounting bracket has a diameter of 13 mm.
1. Lens array
2. Radiator
3. Mounting bracket
4. Tilt
-
lock screw
5. Power cable
6. Data cable (DMX in/out)
7. Control buttons
8. LED display
9. Antenna
CitySource 96 (SmartWhite)
6
IMPORTANT! OVERHEAD RIGGING REQUIRES EXTENSIVE EXPERIENCE, including calculating working load limits, installation material being used, and periodic safety inspection of all installation material and the fixture. If you lack these qualifications, do not attempt the installation yourself, but instead use a professional structural rigger. Improper installation can result in bodily injury or damage to property. For overhead use, always install a safety rope that can hold at least 10 times the weight of the fixture. You must only use safety ropes with screw-on carbines. Pull the safety-rope through the mounting bracket and over the trussing system etc. Insert the end in the carbine and tighten the fixation screw.
Caution: Fixtures may cause severe injuries when crashing down! If you have doubts concerning the safety of a possible installation, do not install the device.
The fixture can also stand directly on the flat surface (e.g. stage) by means of the removable stand:
3.2 Connection to the mains
Fixtures must be installed by a qualified electrician in accordance with all national and local electrical and construction codes and regulation.
Install a suitable plug on the power cord, note that the cores in the power cord are colored according to the following table.
Core (Eu)
Core (US)
Connection
Plug Terminal Marking
Brown
Black
Live L
Light blue
White
Neutral
N
Yellow/Green Green Earth
This device falls under class one and must be grounded!
3.3 Changing the lens array
The standard beam angle of the fixture without lens-array is 12°. If you need a wider beam angle than 12° , you have to install the eggcrate lens module 25° or the optional eggcrate lens modules: 45°, 45°x15° or eggcrate top hat (for placing frost foil under it). How to install eggcrate lens module:
1. Disconnect the fixture from the mains.
2. Place the new eggcrate lens module (2) on the front side of the fixture and screw it to the housing by
means of the four M5x14 screws (1) with washers (3).
CitySource 96 (SmartWhite)
7
You can install a frost foil under the eggcrate top hat to get frost light output.
1. Disconnect the fixture from the mains.
2. Uninstall the eggcrate lens module 25° (2) as described above.
3. Place the frost foil (6) under the the eggcrate top hat (7) and secure it by means of the four screws (1)
and washers (3) on the fixture.
The dimension of the frost foil is 154mm x 103mm, max. thickness= 0.5mm.
The frost foil has to stand temperature of 85°C.
CitySource 96 (SmartWhite)
8
3.4 Installation of the barn-doors and top hat/half top hat
You can install the barn-doors or top hat/half top hat to better define illuminated surface.
1. Disconnect the fixture from the mains.
2. Remove the eggcrate lens module 25°(2) by unscrewing the four M5x14 screws (1) including washers (3).
3. Place the barn-doors module (4) or top hat/half top hat on the eggcrate lens module 25° (2) and screw
them on the fixture using four M5x14 screws (1) and washers (3) as shown on the picture below.
Never close the barn-doors during fixture operation
3.5 DMX 512 connection
The fixture is equipped with two 5-pin XLR connectors for DMX input/output. Only use a shielded twisted-pair cable designed for RS-485 and 5-pin XLR- connectors in order to connect the controller with the fixture or one fixture with another.
Wiring of the XLR connectors: DMX output DMX input XLR socket (rear view): XLR plug (rear view):
1
– Shield
2
- Signal (-)
3
- Signal (+)
4
– Not connected
5
– Not connected
Loading...
+ 17 hidden pages