Robe CitySkape Xtreme, CitySkape Xtreme/W User Manual

Version 2.2
CitySkape Xtreme (RGBW)
Table of contents
1. Safety instructions ...................................................................................................................................................... 3
2. Fixture exterior view ................................................................................................................................................... 4
3. Installation .................................................................................................................................................................. 5
3.1 Rigging the fixture ................................................................................................................................................. 5
3.2 Connection to the mains ...................................................................................................................................... 6
3.3 Installation of the barn-doors, top/half top hats ................................................................................................. 7
3.4 Changing the beam angle ..................................................................................................................................... 7
3.5 DMX 512 connection ............................................................................................................................................ 8
3.6 Master/slave connection ...................................................................................................................................... 8
3.6 Stand-alone operation .......................................................................................................................................... 8
4. CitySkape Xtreme (RGBCW) - DMX protocol ............................................................................................................ 10
5. Control menu map .................................................................................................................................................... 12
6. Fixture menu ............................................................................................................................................................. 14
6.1 Fixture Address ................................................................................................................................................... 15
6.2 Fixture information ............................................................................................................................................. 15
6.3 Personality .......................................................................................................................................................... 16
6.4 Manual mode ...................................................................................................................................................... 17
6. 5 Test sequences................................................................................................................................................... 17
6.6 Stand-alone setting ............................................................................................................................................. 17
6.7 Special functions ................................................................................................................................................. 18
7. RDM .......................................................................................................................................................................... 20
8. Error and information messages .............................................................................................................................. 21
9. Wireless DMX operation ........................................................................................................................................... 21
10. Technical specifications .......................................................................................................................................... 21
11. Cleaning and maintenance ..................................................................................................................................... 24
CitySkape Xtreme (RGBW)
FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY
BEFORE POWERING OR INSTALLING YOUR CITYSKAPE XTREME !
Save it for future reference.
This device has left our premises in absolutely perfect condition. In order to maintain this condition and to ensure a safe operation, it is absolutely necessary for the user to follow the safety instructions and warning notes written in this manual.
The manufacturer will not accept liability for any resulting damages caused by the non-observance of this manual or any unauthorized modification to the device.
Please consider that damages caused by manual modifications to the device are not subject to warranty.
1. Safety instructions
DANGEROUS VOLTAGE CONSTITUTING A RISK OF ELECTRIC SHOCK IS PRESENT WITHIN THIS UNIT!
Make sure that the available voltage is not higher than stated on the rear panel of the fixture.
This fixture should be operated only from the type of power source indicated on the marking label. If you are not sure of the type of power supplied, consult your authorized distributor or local power company.
Always disconnect the fixture from AC power before cleaning, removing or installing the fuses, or any part.
Do not overload wall outlets and extension cords as this can result in fire or electric shock.
Make sure that the power/data cord is never crimped or damaged by sharp edges. Check the fixture and the power/data cord from time to time.
Do not install the unit near naked flames.
During the operation the housing becomes hot (up to 85°C)
Refer servicing to qualified service personnel.
This fixture falls under protection class I. Therefore this fixture has to be connected to a mains socket outlet with a protective earthing connection.
Do not connect this fixture to a dimmer pack.
LED light emission. Risk of eye injury. Do not look straight at the fixture´s LEDs during operation. The intense light beam may damage your eyes.
Keep compustible materials at least 40 cm away from the fixture.
If the fixture has been exposed to drastic temperature fluctuation (e.g. after transportation), do not switch it on immediately. The arising condensation water might damage your device. Leave the device switched off until it has reached room temperature.
Do not shake the fixture. Avoid brute force when installing or operating the fixture. The fixture was designed for indoor use and it is intended for professional application only. It is not for household use.
CitySkape Xtreme (RGBW)
When choosing the installation spot, please make sure that the fixture is not exposed to extreme heat or dust.
Avoid using the unit in locations subject to possible impacts.
The fixture body never must be covered with cloth or other materials.
Only operate the fixture after having checked that the housing is firmly closed and all screws are tightly fastened.
Make sure that the area below the installation place is blocked when rigging, derigging or servicing the fixture.
Do not block the front objective LEDs with any object when the fixture is under operation.
The fixture becomes very hot during operation. Allow the fixture to cool approximately 40 minutes prior to manipulate with it.
Operate the fixture only after having familiarized with its functions. Do not permit operation by persons not qualified for operating the fixture. Most damages are the result of unprofessional operation!
Do not attempt to dismantle or modify the unit.
Please consider that unauthorized modifications on the fixture are forbidden due to safety reasons!
Please use the original packaging if the fixture is to be transported.
If this device will be operated in any way different to the one described in this manual, the product may suffer damages and the guarantee becomes void. Furthermore, any other operation may lead to dangers like short­circuit, burns, electric shock etc.
2. Fixture exterior view
1. LED module 1
7. Power cord
2. LED module 2 8. Antenna (only Wireless DMX version) 3 Tilt-locks for both LED modules 9. Base
4. LED supply 10. Handles
5. Control board
6. DMX in/out cables
CitySkape Xtreme (RGBW)
3. Installation
3.1 Rigging the fixture
Ensure that the structure (truss, wall) to which you are attaching
the fixture is secure.
Mounting via two Omega holders Mounting points for permanent installation
The mounting holes in the Omega holders have a diameter of 13 mm. Use the clamps with M12 bolts only. The four mounting holes in the fixture base have a diameter of 17 mm. Use M16 screws for fastening.
The fixture can be placed directly on the stage floor or can be rigged on the structure via two omega holders in the following positions:
For securing of the fixture on a flat surface in the position B serves two mounting slots of diameter 8.5mm in the fixture base. The four mounting holes of diameter 17mm are intended for permanent installation on the flat surface, especially in position C. Enhanced care has to be considered during the installation of the fixture in the position D via clamps.The clamps should be fastened to the upper support in order to anable the fixture holding onto the bottom support. In case, that the clamps are installed on the bottom support, the fixture could move down on account of its weight.
CitySkape Xtreme (RGBW)
Both LED modules can be adjusted to the desired position either together by means of the the tilt-locks for both LED modules or individually. For individual adjusting of the LED module you do not need any tool as a friction locks keep adjusted position of each LED module.
Danger of injury! Two workers have to handle with the fixture including adjusting the LED modules to the desired position. The LED modules are very heavy.
IMPORTANT! OVERHEAD RIGGING REQUIRES EXTENSIVE EXPERIENCE, including calculating working load limits, installation material being used, and periodic safety inspection of all installation material and the fixture. If you lack these qualifications, do not attempt the installation yourself, but instead use a professional structural rigger. Improper installation can result in bodily injury or damage to property. For overhead use, always install a safety rope that can hold at least 10 times the weight of the fixture. You must only use safety rope with screw-on carbine. Pull the safety rope through the apertures in the fixture base and over the trussing system.
Caution: Fixtures may cause severe injuries when crashing down! If you have doubts concerning the safety of a possible installation, do not install the device.
3.2 Connection to the mains
Fixtures must be installed by a qualified electrician in accordance with all national
and local electrical and construction codes and regulation.
Install a suitable plug on the power cord, note that the cores in the power cord are colored according to the following table.
Core (Eu)
Core (US)
Connection
Plug Terminal Marking
Brown
Black
Live L
Light blue
White
Neutral
N
Yellow/Green Green Earth
This device falls under class one and must be grounded!
CitySkape Xtreme (RGBW)
3.3 Installation of the barn-doors, top/half top hats
You can install barn-doors or top hats to better define illuminated surface. Before installing the equipment disconnect the fixture from the mains.
1. Fit the barn-doors module (1) or top/half top hat (2) on the LED module (4) and fasten it by means of the
12 screws (3) as shown on the picture below.
2. Repeat the same steps for the second LED module of the fixture.
Never close the barn-doors during fixture operation!
3.4 Changing the beam angle
If you need to get a wide beam angle (25°), you have to install frost glasses to both LED modules. Before installing the frost glasses disconnect the fixture from the mains.
1. Unscrew the ten countersunk screws (1) from the LED module (3).
2. Lift the frame (2) with the gasket strip and carefully remove the clear glass (5) from its placing.
Place the frost glass insted of the clear one.
3. Place the frame (2) with the gasket strip back on the LED module (3) and screw it with ten screws (1).
4. Repeat the same steps for the second LED module of the fixture.
CitySkape Xtreme (RGBW)
3.5 DMX 512 connection
The fixture is equipped with 5-pin XLR sockets for DMX input and output.
Only use a shielded twisted-pair cable designed for RS-485 and 5-pin XLR- connectors in order to connect the controller with the fixture or one fixture with another.
Wiring of the XLR connectors:
DMX output DMX input XLR socket (rear view): XLR plug (rear view):
1
– Shield
2
- Signal (-)
3
- Signal (+)
4
– Not connected
5
– Not connected
To build a DMX chain
1. Connect the DMX output of the controller directly with the DMX input of the first fixture in the DMX chain.
2. Connect the DMX output of the first fixture in the DMX chain with the DMX input of the next fixture.
3. Always connect the DMX output with the input of the next fixture until all fixtures are connected.
Do not overload the link. Max. 32 fixtures may be connected on a DMX link. Terminate the link by installing a termination plug in the output of the last fixture. The termination plug is a male 5-pin XLR plug with a 120 Ohm resistor connected between Signal (–) and Signal (+).
3.6 Master/slave connection
To build a master/slave-chain: Connect the DMX output of the master fixture in the data chain with the DMX input of the first slave. Always connect output with the input of the next slave until all slaves are connected (up to 32 fixtures). Caution: It is necessary to terminate the input of the master fixture and the output of the last slave with a 120 Ohm resistor in order to ensure the proper transmission on the data link.
3.6 Stand-alone operation
The fixtures on a data link are not connected to the controller but can execute pre-set programs which can be different for every fixture. To set the program to be played, see the "Stand-alone setting" (menu "St.AL."). "Stand-alone operation" can be applied to the single fixture or to multiple fixtures operating synchronously. Synchronous operation of multiple fixtures requires that they must be connected on a data link and one of them is set as a master (master mode) and the rest as the slaves (slave mode). To set the fixture as the master or slave, see the " Fixture Address " (menu "A001"). Only one fixture can be set as the master. The master fixture starts simultaneous program start in the other slave fixtures. All fixtures have a definite, synchronized starting point when playing back their programs. The number of running program is the same in all slaves and depends on the master's choice (menu "St.AL.“). Every fixture runs its program repeatedly, starting the program step No.1 when requested by the master. Example: If the slave fixture has a shorter program length, it will continuously repeat its program until the master fixture finishes its own program and restarts its program running (slave 1- prog.step 3 will not be finished). If the slave fixture has a longer program length, it will restart at prog. step 1 before it completes all its prog.steps (slave 2 - prog.step 5 will not be played)- see the picture bellow.
Loading...