RND 320-KEL Series, 320-KEL103, 320-KEL102 User Manual

RND 320-KEL Series
USER MANUAL – BEDIENUNGSANLEITUNG – ANVÄNDARMANUAL
RND 320-KEL Series
1
Table of Contents
SAFETY INSTRUCTION 3
RND 320-KEL SeriesRND 320-KEL Series
Safety Symbols
AC lnput 4
Fuse 4
3
OVERVIEW 5
Introduction
Main Features 5
Front Panel Overview 6
5
OPERATION 6
Keyboard Operation
Seing the Max Value of Load 7
Steady State 8
The Storage of Steady State and Recalling 10
6
Safety Symbols
These safety symbols may appear in this manual or on the series.
WARNING
Ml-MS Fast Recall and Storage 10
Short Circuit 11
Dynamic Test 11
Sequential Operation 17
Baery Test 19
OCP Test 21
OPP Test 24
External Trigger 27
Remote Compensation 28
Keyboard LOCK 28
Buzzer ON/OFF 29
Communication 29
DANGER High Voltage
EARTH (ground) Terminal
SPECIFICATIONS 30
2 3
RND 320-KEL SeriesRND 320-KEL Series
Safety Guidelines
• Do not block or obstruct the cooling fan vent opening
• Avoid severe impacts or rough handling that leads to damage.
• Do not discharge static electricity.
• Do not disassemble unless you are qualied as service personnel.
AC INPUT
• AC Input Voltage: 110V / 120V / 220V / 230V , 50 / 60 Hz
• Connect the protective grounding conductor of the AC power cord to an earth ground, to avoid electrical shock.
Operation Environment
• Location: Indoor, no direct sunlight, dust free, almost non-conductive pollution
(note below)
• Relative Humidity:< 80%
• Altitude: < 2000 m
• Temperature: 0-40 OC
Introduction
RND KEL series (150W~300W), single-channel programmable DC electronic loads, are designed for middle & high-end applications. They can oer multiple solutions according to your needs. The online voltage measures and adjusts, or simulate a short circuit test, using the simple keypad on the front panel. RND
KEL series DC loads are versatile instruments for static and
dynamic testing of power supplies, baeries, DC DC converters, and baery chargers, providing users the best testing solution.
Main Features
• Highlight LED display
• 5digit displays, and accurate outputs
• Resolution of voltage and current: 0.1 mV / 0.1 mAProtection and Over voltage Protection
• 100 groups of memories for fast recall
• Four working modes: CV/CC/CR/CP
Storage Environment
• Location: Indoor
• Relative Humidity: < 70%
• Temperature: -10-70”C-
FUSE
• To ensure re protection, replace the fuse only with the specied type and rating.
• Disconnect the power cord before fuse replacement.
• Make sure the cause of fuse blow out is xed before fuse replacement.
MODEL
RND
320-KEL102
RND
320-KEL103
110V/120V
220V/230V
• Remote Compensation Function
• Baery Test Function
• Key board Lock
• Power o memory function
• Short-circuit function
• Remote Compensation Function
• External Trigger Function
• Seing Function of Baud Rate
4 5
RND 320-KEL SeriesRND 320-KEL Series
Front Panel Overview
2. Seing the maximum value of load Description: Seing low voltage (18V), low current (3A) and below them will improve accuracy. Method of operation: Taking the max current 3A, max voltage 18V and max power 100W as example, the max resistance is 1000ohms.
1. Keyboard Operation
1. Esc: Cancel key which can return to the initial mode.
2. Ml-MS: quickly recalling the Ml-MS stored value of the
steady state.
3. Recall: Recall Key, such as, recalling the steady storage
with Ca11+2.
4. Shi: Seing or Storage Function Keys, such as storing the
stationary content with Shi+2.
5. Le-Rotating Key, moving to where needs to be adjusted and
will ash.
6. Entering numbers.
7. Constant Current Mode Buon.
8. Constant Voltage Mode Buon.
9. Constant Power Mode Buon.
10. Constant Resistance Mode Buon.
11. Conrmation Buon.
12. On/O: Turning On/O the load output.
13. £.-Adjusting the number or selecting Add.
14. T-Adjusting the number or selecting subtract.
15. Knob: Adjusting the number or selecting it.
6 7
RND 320-KEL SeriesRND 320-KEL Series
3. The Operation Function of Steady State
Note: The electronic load can work in the following 4 steady-state mode.
3.1 Constant Current Operation Mode CC
Note: In constant current mode, the load makes the tested equipment on the set voltage no maer how the input voltage changes. Operation Method:
1. Press the CC buon on the keyboard to enter constant
current operation mode.
2. Seing the desired constant current through the keyboard.
3. Turn on the ON/OFF buon to start the electronic load.
Load Current
Operation Method:
1. Press the CR buon on the keyboard to enter constant resistance operation mode.
2. Seing the desired constant resistance through the keyboard.
3. Turn on the ON/OFF buon to start the electronic load.
3.2 Constant Voltage Operation Mode CV
Note: In constant voltage mode, the load makes the tested equipment on the set voltage no maer how the input current changes. Operation Method: 1. Press the CV buon on the keyboard to enter constant voltage operation mode.
2. Seing the desired constant voltage through the keyboard.
3. Turn on the ON/OFF buon to start the electronic load. Load Voltage
3.4 Constant Power Operation Mode CW
Note: In constant power mode, the load makes the tested equipment on the set resistance no maer how the input voltage and current change. Operation Method: 1. Press the CW buon on the keyboard to enter constant power operation mode.
2. Seing the desired constant power through the keyboard.
3. Turn on the ON/OFF buon to start the electronic load.
3.3 Constant Resistance Operation Mode CR
Note: In constant resistance mode, the load makes the tested equipment on the set resistance no maer how the input voltage and current change.
8 9
RND 320-KEL SeriesRND 320-KEL Series
4. The Storage Function of Steady State and Recalling
Note: The load can save and recall 100 sets of stationary seing values.
And to set the values, the number keys, knob and up & down buons all can be used.
4.1 Storage function
Operation Method: Taking 10.000V stored to 99 as example.
5. Ml-MS Fast Recall and Storage Function
5.1 Ml-MS Fast Recall Function
Note: By pressing Ml-MS, the steady state content stored in Ml-MS can be quickly recalled.
5.2 Ml-MS Fast Storage Function
Note: You can change the content of Ml-MS by selecting Ml-MS buon; and then press the currently selected Ml-MS buon to fast save the value to the currently selected M key. For example, the previous content of Ml is CV+15.001V and now needing to modify as CV+14.000V, you can press Ml to recall the content and then modify to 14.000V through rotating the knob and then pressing the number keys to select the value you want. Aer that, press Ml again to save it in Ml.
6. Short Circuit Function Note: the load will make the tested equipment output the max current. Operation Method:
4.2 Recall Function
Operation method: taking recalling the stored steady-state value in 99
As example.
7. Dynamic Test Function Note: There are 6 seing functions in this mode: Dynamic CV, Dynamic CC,
Dynamic CR, Dynamic CW, Dynamic Pulse and Dynamic Flip. And this mode has no storage function, so it can be only set rst and then run.
7.1 Dynamic CV, Dynamic CR, & Dynamic CW Description: used for the dierent duty cycle output of 2 dierent volt ages at a certain frequency. Operation Method: Taking the rst voltage lV, the second voltage 2V , the cycle frequency lHZ and the duty cycle 40% as example; as for Dynamic CR and Dynamic CW, just need to change the seing voltage into resistance or power. And Dynamic CR selects mode 3 while Dynamic CW selects mode 4.
10 11
RND 320-KEL SeriesRND 320-KEL Series
7.2 Dynamic CC Note: used for the dierent duty cycle output of 2 dierent currents at
a certain frequency.
Operation Method: taking it as example that the change slope of the rst current is 0.00lA/Us, that of the second current is 0.002A/Us, the rst current is lA, the second current is 2A, the cycle frequency is lHZ and the duty cycle is 40%.
Remarks: Aer pressing ON/OFF to start, the LED display on the right boom is the count running once.
12 13
RND 320-KEL SeriesRND 320-KEL Series
Remarks: Aer pressing ON/OFF to start, the LED display on the right boom is the count running once.
7.3 Dynamic Pulse
Note: It can at most set 10 groups of baery test parameters. According to the set current, voltage, capacity and time, it tests the baery. And the test will be turned o automatically once it meets any one of the conditions. Operation Description: taking it as example that the seing is saved in group 1, the current range is lOA, the discharge current is lA, the discharging end-o voltage is 2A, the discharging end-o capacity is
0.SAH and the discharging time is 200s.
Remarks: press ON/OFF to start and then the LED display on the right boom is the count of triggers.
14 15
RND 320-KEL SeriesRND 320-KEL Series
7.4 Dynamic Toggle
Note: Every time when receiving a trigger signal, the load will toggle between the rst and second seing current. Operation method: taking it as example that the change slope of the rst current is 0.00lA/Us, that of the second current is 0.002A/Us, the rst current is lA, and the second current is 2A.
8. Sequential Operation Function
8.1 Sequential Seing Function
Note: It can save 7 groups at most and every set it can at most set 84 dynamic currents. And the set current can be toggled in sequence. Operation description: taking it as example that the
seing is saved in group 1, the max current is 4A,there are 3 dynamic currents, the rst dynamic current is lA, the change rate is 0.00lA/us, the time is ls, the second dynamic current is 2A, the change rate is 0.002A/us, the time is 2s, the rst dynamic current is 3A, the change rate is 0.003A/us, the time is 3S and the repetition
times is 5 times.
Remarks: press ON/OFF to start and then the LED display on the right boom is the count of triggers.
16 17
8.2 Sequence Recall Function
Note: recall one group of storage and use it. Operation Description: recall the rst group of storage and use it.
RND 320-KEL SeriesRND 320-KEL Series
9. Baery Test Function
9.1 The Seing Function of the Baery Test
Note: It can at most set 10 groups of baery test parameters. According to the set current, voltage, capacity and time, it tests the baery. And the test will be turned o automatically once it meets any one of the conditions. Operation Description: taking it as example that the seing is saved in group 1, the current range is lOA, the discharge current is lA, the discharging end-o voltage is 2A, the discharging end-o capacity is
0.SAH and the discharging time is 200s.
Remarks: During the operation, once press Esc and it will exit the mode. If there are some wrong entering, you can rotate the knob. When the complete value appears, enter again.
18 19
RND 320-KEL SeriesRND 320-KEL Series
9.2 The Recall Function of the Baery Test
Note: Recall one group of the storage and use it. Operation Description: Recall the rst group of storage and use it.
Remarks: Press ON/OFF to start and then the LED display on the le boom is the running time and the LED display on the right boom is the consumption of capacity.
10. OCP Test Function
Note: when the voltage reaches the VON value, it will delay for some time, and the current outputs; at intervals, the step value will decrease progressively until it reaches the cut-o current, or the voltage is higher than that set by OCP, and then the output ends. Aer that, if the voltage is higher than the OCP voltage and meanwhile the current value is between the maximum and the minimum set currents, it passes; otherwise, it fails.
10.1 Function of OCP Test Seings Note: It can set at most 10 groups of test parameters.
Remarks: During the operation, once press Esc and it will exit the mode. If there are some wrong entering, you can rotate the knob. When the complete value appears, enter again.
20 21
Operation description: taking it as example that the seing is saved in group 1, VON voltage is 10V, time delay of VON voltage is Ss, the current range is 3A, the beginning current is 2A, the step reduction value is 0.1A, the reduction time is ls, the ending current is lA, OCP voltage is 8V, the maximum current is 1.9A and the minimum current is 1.1A.
RND 320-KEL SeriesRND 320-KEL Series
Remarks: During the operation, once press Esc and it will exit the mode. If there are some wrong entering, you can rotate the knob. When the complete value appears, enter again.
Remarks: press ON/OFF to start and then the LED display on the right boom is the count of triggers.
22 23
10.2 The Recall Function of OCP Test
Note: recall one group of storage and use it. Operation Description: recall the rst group of storage and use it.
RND 320-KEL SeriesRND 320-KEL Series
11.1 The Seing Function of OPP Test
Note: It can set at most 10 groups of test parameters. Operation description: taking it as example that the seing is saved in group 1, VON voltage is 10V, time delay of VON voltage is Ss, the current range is 3A, the beginning power is 20W, the step reduction value is lW, the reduction time is ls, the ending power is l0W, OPP voltage is 8V, the maximum power is 15W and the minimum power is 10W.
Remarks: press ON/OFF to start and then the LED display on the le boom is whether it passes or not; and that on the right boom is the set current value at present.
11. OPP Test Function
Note: when the voltage reaches the VON value, it will delay for some time, and the power outputs; at intervals, the step value will decrease progressively until it reaches the cut o power, or the voltage is higher than that set by OPP, and then the output ends. Aer that, if the voltage is higher than the OPP voltage and meanwhile the power value is between the maximum and the minimum set powers, it passes; otherwise, it fails.
24 25
6
Enter th e beginning power 20W by pressing t he k nob o r but tons a nd then press “ ” to enter the nex t parame ter settings.
Enter the step powe r 1W by pressin g
0.0000V 0.0000A 0V P0106
RND 320-KEL SeriesRND 320-KEL Series
11.2 The Recall Function of OPP Test
Note: recall one group of storage and use it. Operation Description: recall the rst group of storage and use it.
7
8
9
10
the knob or but tons and then press “ ” to en te r the next paramet er settings .
Enter th e step re duction time 1s by pressing t he k nob o r buttons a nd then press “ ” to enter the next parame ter settings.
Enter the ending p ower pressing t he k nob or
but tons a nd
10W b y
then press “ ” to enter the nex t parame ter settings.
Enter the OPP voltage 8V by pressing the knob or buttons and thenpres s “ ” to enter the next
0.0000V 0.0000A 0V P0107
0.0000V 0.0000A 0V P0108
0.0000V 0.0000A 0V P0109
0.0000V 0.0000A 0V P0110
Remarks: press ON/OFF to start and then the LED display on the le boom is whether it passes or not; and that on the right boom is the set power value at present.
parame ter settings.
12. External Trigger Function
11
Enter th e maximu m powe r 15W by pressing t he k nob o r but tons a nd then press “ ” to enter the nex t
0.0000V 0.0000A 0V P0110
Note: Press Shi+CR to switch the external trigger function. Through the remote control, the steady state mode can be opened; the test mode of the dynamic state, the sequence operation mode and the baery test mode can be triggered.
parame ter settings.
Remarks: when LED GRAP on the display lights on, it can be triggered externally. And here there is the memory function, that is, the trigger will be saved.
12
Enter the minimum powe r 10W by pressing the knob or butto ns and then press “ ” to finish the
Return to the steady stat e mode.
settings .
Remarks: During the operation, once press Esc and it will exit the mode. If there are some wrong entering, you can rotate the knob. When the complete value appears, enter again.
26 27
RND 320-KEL SeriesRND 320-KEL Series
13. Remote Compensation Function
Note: Press Shi+CW to enter the switch of the remote compensation function. Remarks: When there is the remote compensation, the LED COMM will light on. And there is no memory function.
14. Keyboard Lock Function
Note: Press Shi+ the keyboard will lock. Remarks: Aer the keyboard is locked, only ON/OFF and Shi are valid. And during the dynamic pulse mode and dynamic toggling mode, the buon 3 is valid. There will be no memory function.
15. Baud Rate Seing Function
Note: Manually modify the baud rate. Operation Description: changing the baud rate 57600 to 115200 as example.
16. Buzzer ON/OFF Function Note: press Shi+ 1 to switch the buzzer on and o. Remarks: there are memory function here.
17. Communication with PC Please refer to the communication protocol.
Remarks: When the keyboard is not locked, press Esc at any time to return to the steady state mode. From one mode switched to another mode, press Esc to enter the steady state mode and then switch the modes.
Remarks: please modify when there are no communications. Here there is memory function.
28 29
Specications
Note: The specications below are tested under the conditions of temperature 25 °C +-5 °C and the warm-up for 20 minutes.
RND 320-KEL SeriesRND 320-KEL Series
MODELS
RND 320 KEL102
RND 320 KEL103
Note: Specications are subject to change without notice.
30 31
RND 320-KEL Series
Distrelec Group AG
Grabenstrasse 6, CH-8606 Nänikon
www.distrelec.de
32
Loading...