XY XY XY
SPECIFICATION
INPUT POWER: +24VDC nominal, range: 18 to 30VDC 0.3A DC Total Max. ~24VAC nominal, range: 15 to 24VAC 50/60HZ 0.3A AC Total Max.
(AC must not be grounded)
FUSE:
F2 on Main Board: Polyswitch 750mA Polyswitch device resets after the fault is cleared and power to the circuit is removed
SENSOR:
Combustible gases: Catalytic Toxic gases and Oxygen: Electrochemical
OUTPUT SIGNAL:
RS-485 with OPTIMUX PROTOCOL AND MODBUS PROTOCOL AVAILABLE CONTROLLER: M-CONTROLLER or Q4 CONTROLLER 4-20mA Analog Output, 1-5VDC, 2-10VDC Output 3X SPDT RELAYS: 1.0A MAX. @30VDC (RESISTIVE LOAD)
0.3A MAX. @125VAC (RESISTIVE LOAD)
ENCLOSURE:
IP 66 & NEMA 4, 4X, 12 & 13
OPERATING TEMPERATURE:
-40°C to 70°C, depends on sensor specification
AMBIENT HUMIDITY:
5% TO 95% RH (NON- CONDENSING)
STORAGE TEMPERATURE:
0°C to 20°C, depends on sensor specification
SIZE:
150mm X 90mm X 65mm
WEIGHT:
LESS THAN 0.5lbs
UNLESS OTHERWISE SPECIFIED:
DIMENSIONS ARE IN INCHES TOLERANCES: FRACTIONAL 1/32 ANGULAR: MACH .5 degrees BEND TWO PLACE DECIMAL .02 THREE PLACE DECIMAL .010
INTERPRET GEOMETRIC TOLERANCING PER:
MATERIAL
FINISH
DO NOT SCALE DRAWING
3
DRAWN
CHECKED
ENG APPR.
MFG APPR.
Q.A.
COMMENTS:
NAME
XY
XY
XY
2010/02/25
2010/02/25
2010/02/25
DATE
TITLE:
SIZEBDWG. NO.
SCALE: 1:8
2
Quatrosense Environmental Ltd
Q5
INSTALLATION DRAWING
85950-002-000
WEIGHT:
SHEET 1 OF 5
1
REV
B
D
C
B
A
8
7
6
5
4
ZONE REV. DESCRIPTION DATE APPROVED
- - See Sheet1 - -
3
2
REVISIONS
1
Power and RS-485 Connection:
D
Q5 MAIN BOARD
D
C
B
UNLESS OTHERWISE SPECIFIED:
DIMENSIONS ARE IN INCHES TOLERANCES: FRACTIONAL
A
NOTE:
GROUND THE SHIELD IN CONTROLLER SIDE1. GROUND ON ONE END ONLY2.
678
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF <INSERT COMPANY NAME HERE>. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF <INSERT COMPANY NAME HERE> IS PROHIBITED.
5
NEXT ASSY USED ON
APPLICATION
4
ANGULAR: MACH BEND TWO PLACE DECIMAL THREE PLACE DECIMAL
INTERPRET GEOMETRIC TOLERANCING PER:
MATERIAL
FINISH
DO NOT SCALE DRAWING
DRAWN
CHECKED
ENG APPR.
MFG APPR.
Q.A.
COMMENTS:
3
XY
XY
XY
2010/02/25
2010/02/25
2010/02/25
DATENAME
Quatrosense Environmental Ltd
TITLE:
Q5
INSTALLATION DRAWING
SIZEBDWG. NO.
85950-002-000
SCALE: 1:2
2
SHEET 2 OF 5
1
C
B
A
REV
B
8
7
6
Power and RS-485 Connection:
D
Q5 MAIN BOARD
5
4
ZONE REV. DESCRIPTION DATE APPROVED
- - See Sheet1 - -
3
2
REVISIONS
1
D
C
B
UNLESS OTHERWISE SPECIFIED:
DIMENSIONS ARE IN INCHES TOLERANCES: FRACTIONAL
A
NOTE:
GROUND THE SHIELD IN CONTROLLER SIDE1. GROUND ON ONE END ONLY2.
678
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF <INSERT COMPANY NAME HERE>. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF <INSERT COMPANY NAME HERE> IS PROHIBITED.
5
NEXT ASSY USED ON
APPLICATION
4
ANGULAR: MACH BEND TWO PLACE DECIMAL THREE PLACE DECIMAL
INTERPRET GEOMETRIC TOLERANCING PER:
MATERIAL
FINISH
DO NOT SCALE DRAWING
DRAWN
CHECKED
ENG APPR.
MFG APPR.
Q.A.
COMMENTS:
3
XY
XY
XY
XY
DATENAME
2010/02/25
2010/02/25
2010/02/25
2010/02/25
2
Quatrosense Environmental Ltd
TITLE:
Q5
Installation Drawing
SIZEBDWG. NO.
85950-002-000
SCALE: 1:2
WEIGHT:
SHEET 3 OF 5
1
C
B
A
REV
B
8
7
6
5
4
ZONE REV. DESCRIPTION DATE APPROVED
- - See Sheet1 - -
3
2
REVISIONS
1
D
D
Terminator Enable/Disable?
The terminator on each end of the RS485 loop is designed to match the electrical impedance characteristic of the twisted pair loop, and will prevent signal echoes from corrupting the data on
C
the line. The terminator should be enabled on BOTH ends of the RS485 loop. Short and medium length modbus/485 loops can operate without the terminating resistor. Longer runs may require the terminating resistors. But adding terminator dramatically increases power consumption.
C
Sensor Location:
Several factors should be considered when selecting locations to install sensors. The following general suggestions should be considered to assure the detection of the target gas. Select the most suitable location for each sensor.
1. Air Currents: If there are fans, winds, or others sources of air movement, gases may tend to rise to collect in certain areas of a facility. The local air
B
currents should be assessed to aid in selecting the sensor location. In outdoor situations considerations such as prevailing winds should be accounted for. Air convection can often be more important in determining gas concentrated areas than factors of Vapor Density.
2. Vapor Density: For the target gas heavier than air. Detecting location should be 9 - 18 inch (0.23m to 0.46m) above the floor.
3. Gas Emission Sources: As a rule, at least one sensor should be located in close proximity to each point where a leak is likely to occur. This is particularly important when a liquid having a low volatility is monitored.
4. Environmental Factors: Designed to rugged outdoor use consider the following in selecting locations. Install sensors where they will be protected from wind, dust, snow, water, vibration and shock.
B
Twisted Pair?
A
RS-485 is designed to be a balanced system. The signal on one wire is ideally the exact opposite of the signal on the second wire. In other words, if one wire is transmitting a high, the other wire will be transmitting a low, and vice versa. Although RS-485 can be successfully transmitted using multiple types of media, it should be used with wiring commonly called "twisted pair."
UNLESS OTHERWISE SPECIFIED:
DIMENSIONS ARE IN INCHES TOLERANCES: FRACTIONAL ANGULAR: MACH BEND TWO PLACE DECIMAL THREE PLACE DECIMAL
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF <INSERT COMPANY NAME HERE>. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF <INSERT COMPANY NAME HERE> IS PROHIBITED.
678
5
NEXT ASSY USED ON
APPLICATION
4
INTERPRET GEOMETRIC TOLERANCING PER:
MATERIAL
FINISH
DO NOT SCALE DRAWING
DRAWN
CHECKED
ENG APPR.
MFG APPR.
Q.A.
COMMENTS:
3
NAME
XY
XY
XY
DATE
2010/02/25
2010/02/25
2010/02/25
2
Quatrosense Environmental Ltd
TITLE:
Q5
INSTALLATION DRAWING
SIZEBDWG. NO.
85950-002-000
SCALE: 1:2
SHEET 4 OF 5
1
A
REV
B
8
4-20mA and VDC Output:
D
7
6
5
4
ZONE REV. DESCRIPTION DATE APPROVED
- - See Sheet1 - -
3
2
REVISIONS
1
D
C
B
Q5 provides one channel 4-20 milliamp analog output and 1-5VDC or 2-10VDC analog output . The maximum output impedance is 600 ohms for 4-20mA output. The maximum current is 10 mA for VDC output.
A
Test point SIG+ and SIG- are used to measure the current online when the Q5 is working in the field.
678
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF <INSERT COMPANY NAME HERE>. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF <INSERT COMPANY NAME HERE> IS PROHIBITED.
5
NEXT ASSY USED ON
APPLICATION
4
UNLESS OTHERWISE SPECIFIED:
DIMENSIONS ARE IN INCHES TOLERANCES: FRACTIONAL ANGULAR: MACH BEND TWO PLACE DECIMAL THREE PLACE DECIMAL
INTERPRET GEOMETRIC TOLERANCING PER:
MATERIAL
FINISH
DO NOT SCALE DRAWING
3
DRAWN
CHECKED
ENG APPR.
MFG APPR.
Q.A.
COMMENTS:
NAME
XY
XY
XY
DATE
2010/02/25
2010/02/25
2010/02/25
2
Quatrosense Environmental Ltd
TITLE:
Q5
INSTALLATION DRAWING
SIZEBDWG. NO.
85950-002-000
SCALE: 1:2
SHEET 5 OF 5
1
C
B
A
REV
B