WARNING
Read and understand this instruction manual before operating detector. Improper use of the detector could result in bodily harm or death.
Periodic calibration and maintenance of the detector is essential for proper operation and correct readings. Please calibrate and maintain this detector regularly! Frequency of calibration depends upon the type of use you have and the sensor types. Typical calibration frequencies for most applications are between 3 and 6 months, but can be required more often or less often based on your usage.
65-2302/65-2303 Toxic Detector
Product Warranty
RKI Instruments, Inc. warrants gas alarm equipment sold by us to be free from defects in materials, workmanship, and performance for a period of one year from date of shipment from RKI Instruments, Inc. Any parts found defective within that period will be repaired or replaced, at our option, free of charge. This warranty does not apply to those items which by their nature are subject to deterioration or consumption in normal service, and which must be cleaned, repaired, or replaced on a routine basis. Examples of such items are:
Warranty is voided by abuse including mechanical damage, alteration, rough handling, or repair procedures not in accordance with the operator’s manual. This warranty indicates the full extent of our liability, and we are not responsible for removal or replacement costs, local repair costs, transportation costs, or contingent expenses incurred witho u t our prior approval.
a) Absorbent cartridges d) Batteries b) Pump diaphragms and valves e) Filter elements c) Fuses
THIS WARRANTY IS EXPRESSLY IN LIEU OF ANY AND ALL OTHER WARRANTIES AND REPRESENTATIONS, EXPRESSED OR IMPLIED, AND ALL OTHER OBLIGATIONS OR LIABILITIES ON THE PART OF RKI INSTRUMENTS, INC. INCLUDING BUT NOT LIMITED TO, THE WARRANTY OF MERCHANTABILITY OR F ITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL RKI INSTRUMENTS, INC. BE LIABLE FOR INDIRECT, INCIDENTAL, OR CONSEQUENTIAL LOSS OR DAMAGE OF ANY KIND CONNECTED WITH THE USE OF ITS PRODUCTS OR FAILURE OF ITS PRODUCTS TO FUNCTION OR OPERATE PROPERLY.
This warranty covers instruments and parts sold to users by authorized d istributors, dealers, and representatives as appointed by RKI Instruments, Inc.
We do not assume indemnification for any a ccident or damage caused by the opera tion of this gas monitor, and our warranty is limited to the replacement of parts or our complete goods.
65-2302/65-2303 Toxic Detector
Table of Contents
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
65-2302 Toxic Detector. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Junction Box. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Mounting the Toxic Detector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Wiring the Toxic Detector to a Controller. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Startup. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Introducing Incoming Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Setting the Zero (Fresh Air) Signal. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Maintenance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Preventive Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Replacing Components of the Toxic Detector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Calibration Frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Special Note About Calibrating a ClO2 Detector. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Preparing for Calibration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Setting the Zero (Fresh Air) Reading. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Setting the Response Reading (Span) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Returning to Normal Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
65-2302/65-2303 Toxic Detector
Overview
This manual describes the 65-2302 and 65-2303 toxic detectors. This manual also describes how to install, start up, maintain, and calibrate the toxic detector when used with a gas monitoring controller. A parts list at the end of this manual lists replacement parts and accessories for the toxic detector.
The 65-2303 toxic detector includes the 65-2302 toxic detector and a junction box. The 65-2302 toxic detector does not include a junction box and is normally mounted in one
of a controller’s conduit hubs. I f you are using a 65-2302 toxic detector, disregard all references to the junction box and junction box terminal strip.
The 65-2302 and 65-2303 detectors can be used for various target gases which are listed in Table 1 below. For a particular target gas, the part number of the toxic detector will be of the format 65-2302-XXX or 65-2303-XXX. For example, 65-2302-CLO2 is for chlorine dioxide (ClO
Specifications
) detection.
2
WARNING: Do not use this product in a manner not specified in this instruction
manual.
Table 1 lists specifications for the various 65-2302/65-2303 toxic detectors.
Table 1: Specifications
Target Gas and Detection Range 65-2302-CL2/65-2303-CL2: Chlorine (Cl
65-2302-CL2-05/65-2303-CL2-05: Chlorine (Cl 65-2302-CL2-10/65-2303-CL2-10: Chlorine (Cl 65-2302-CLO2/65-2303-CLO2: Chlorine Dioxide (ClO
) 0 - 3.00 ppm
2
) 0 - 5.00 ppm
2
) 0 - 10.0 ppm
2
) 0 - 1.00 ppm
2
Sampling Method Diffusion Accuracy ± 10% of reading or ± 5% of full scale (whichever is greater) Response Time T90 in 60 seconds Operating Temperature &
-4°F to 104°F (-20°C to 40°C)
Humidity
WARNING: When using the 65-2302/65-2303, you must follow the instructions and
warnings in this manual to assur e proper and safe operation of the 65-2302/65-2303 and to minimize the risk of personal injury. Be sure to maintain and periodically calibrate the 65-2302/65-2303 as described in this manual.
65-2302/65-2303 Toxic Detec tor • 1
Description
3/4 NP T Conduit H ub
Detector
Juncti on Box
Plug- in Sen sor (different for each detector type)
Detector Housing Cap
VersaporRMembrane
Detector Housing Body (di fferent for each detector type)
Cap Gasket
This section describes the components of the 65-2302 and 65-2303. The 65-2303 includes the 65-2302 toxic detector and a juncti on box. The 65-23 02 does not i nclude a juncti on box. Figure 1 below shows the components of the 65-2303.
65-2302 Toxic Detector
The 65-2302 toxic detector consists of the detector housing body, detector housing cap, cap gasket, and the plug-in sensor.
Figure 1: 65-2303 Component Location
Figure 2: 65-2302 Toxic Detector Component Location
2 • 65-2302/65-2303 Toxic Detector