RK Electronics STRP Data Sheet

STRP
Seal & Temp-Stat Relay
Operation
The STRP monitors the seal and embedded temperature sensor on submersible pump motors. If the resistance in the seal area goes lower than the set point or the temp-stat opens, individual relay outputs will be energized, one for a seal failure and one for a temp-stat failure.
2-Input Operation
To monitor the seal for a leakage, low voltage is applied to the seal sensor. If the resistance sensed falls below the adjustable trip point, the seal fault output relay will be energized. High resistance is considered “good”.
To monitor the temp-stat, low voltage is applied to the normally closed contact. If the contact opens, the temperature fault output relay will be energized. A normally closed input is con­sidered “good.”
1-Input Operation
An alternate input option is also built into the STRP. With the 1-input option selected, if the resistance is between 330Ω and 1,500Ω, both the seal and temp-stat are considered “good”. If the input resistance falls below 330Ω, a seal fault is indicated and the seal fault output relay will be energized. If the input resistance goes above 1,500Ω, a high temperature fault is indicated and the temperature fault output relay will be energized.
Specications
Electrical
Supply Voltage:
12VDC & 24VDC 24VAC, 120VAC & 240VAC
Frequency: 50/60Hz Power Consumption: 2VA Inputs: 5VDC @ 2mA
2-Input:
Seal: Adjustable 5KΩ to 200KΩ, +5KΩ Hystersis Temp-Stat: 1NC Contact, Good condition
1-Input:
Resistance trip point xed at 330Ω & 1,500Ω Seal Fault: <330Ω Temp-Stat Fault: >1,500Ω
Contact Ratings:
Seal: 1NO Temp-Stat: SPDT 10A @ 120VAC, 25°C 5A @ 277VAC 1/8HP @ 120/277VAC 5A @ 30VDC
Ordering Information
STRP - 120A - B - XXXX
R-K Model
Dimensions
3.88" 0.5" 2.0"
Cincinnati, OH
SEAL 100K GOOD
SEAL 2000K GOOD�
TEMP GOOD
GOOD
TEMP
STRP
Adjustments: (4) Membrane Buttons Display: 16 Character, 2-line display,
with back light
Physical
Mounting: Panel Mounting: Through
the door
Termination:
Terminals: Pluggable Terminal Blocks
Packaging: Panel Mount Weight: 1 Pound
Ambient Temperatures
Operating:
Terminal Blocks: -40°C to 60°C (Display and membrane buttons may not function below -20°C.)
Storage: -40°C to 85°C
Termination
B - Pluggable Terminal Blocks
Voltage
12D - 12VDC 24V - 24VDC 24A - 24VAC 120A - 120VAC 240A - 240VAC
3"
Adjustments are available to:
• Select 1-Input or 2-Input operation
• Select the resistance on the 2-input operation from 5KΩ to 200KΩ
• Select a Manual or Automatic reset after a fault has been corrected.
5/25/16
Connections
Seal
Temp
NO
C
NCCNO
CST
L1
2-Input
L2
Seal
NO
CST
C
1-Input
Loading...