DPT
Digital
P
ercentage Timer
Specifications
Electrical
Supply 'Voltage:
24VAC, 120VAC & 240VAC, 1Ø
Frequency; 50/60Hz
Display: 16 Character, 2 Line, LCD
Back Lighting
Adjustments:
Membrane Buttons & Display
Total Cycle Times: 15 & 30 Min
On Tme Percentages:
5% to 95%, 5% Increments
Manual: On or Off
Running Hours:0 to 99,999 Hrs.
Output Rating @ 25°C:
10 Amps @ 120VAC
6 Amps @ 277VAC
1/8 HP @ 120/277 VAC
5 Amps @ 30 VDC
• Digital Dispaly:
- R
emaining Time
- Time & Percentage
Settings
- Running Hours
- Output Relay Status
• Multiple Mounting
Dimensions
• SPDT Contacts
• Gasketed Cover
DPT - 120A - 15/30 -
Supply Voltage
24A - 24VAC
1
20A - 120VAC
240A - 240VAC
Special
xxxx - Special
The DPT is a Digital PercentageTimer.
Operational information is displayed for
easy viewing: tiime remaining till relay
transfer, relay status, running hours &
set-up parameters.
With the supply voltage active, The DPT
will activate the relay output for the
percentage of time selected in set-up.
For total cycle time, you can select either
15 or 30 minutes. On time can be
selected in 5% increments for 5% to
95%.
Manual selection of either continuous On
or Off is available.
Running hours are accumulated based
on the output relay being energized.
Operation
Physical
Mounting: Panel Mounting
4 - Inserts for 2 mounting dim
Termination: Pluggable Block
Packaging: Gasketed Face
Weight: 1 Pound
Am
bient:Temperatures:
Operating : -20°C to 60°C
Storage: 40°C to 85°C
Dimensions
Connections
Ready to
Submit
Timing
1
5/30 - 15 & 30 Minutes
Supply
Voltage
NOCNC
MS
.
.
DPMP
Voltage Ranges:
• 200 to 240VAC, 1Ø
• 200 to 600VAC, 3Ø
Digital Display:
• Line Voltages
• Frequency
• Imbalance %
• Output Relay Status
• Last 4 Faults
• Set-Up Menus
SPDT Contacts
Operation
The DPMP is a Digital Phase Monitor that will monitor line voltages from
200VAC up to 600VAC. Actual line
voltages and set-up parameters are set
via the digital display. The supply voltage
must be available during operation.
With the supply voltage active, you can
set-up all of the DPMP’s settings without
the line voltage connected.
When the DPMP is connected to the line
voltage, it will monitor the line and if everything is within the set-up parameters,
the output contacts will be activated. If
the line voltages fall outside the set-up
parameters, the output relay will be
de-enegized after the trip delay.
Once the line voltages recover, the
DPMP will re-energize the output relay
after the re-start time delay (manual to 4
minutes).
All settings and the last 4 faults are
retained, even if there is a complete loss
of power.
10/9/15
L1 L2 L3
460 460 460 ON
Digital Multi-Range
3Ø Voltage Monitor
Specications
Electrical
Line Voltage: 200 to 240VAC, 1Ø
200 to 600VAC, 3Ø
Supply Voltage:
12VDC, 24VDC, 24VAC, 120VAC &
240VAC,1Ø
Frequency: 50/60Hz
Display:
16 Character, 2 line, LCD back lighting
Adjustments:
Membrane Buttons & Display
Nominal Voltage: Adj. 200 to 600VAC
Over/Under Voltage: Adj. 7% to 15%
Phase Imbalance: 3% to 10%
Phase Rotation: A - B - C
Delays:
Trip Delay: Adj. 2 sec. to 10 sec.
Re-Start Delay: Adj. Manual Reset to 4 min.
Power Consumption: 2.1VA
Ordering Information
Dimensions
L1 L2 L3
460 460 460 ON
3.88"
Connections
Listed
42L2
R-K Model
DPMP
DPMP - 24A - B -
Supply Voltage
12D - 12VDC
24D - 24VDC
24A - 24VAC
120A - 120VAC
240A - 240VAC
0.71"
L1
L2
L3
L1
L3
L2
NO
NC
MS
Output Rating @ 25°C:
10 Amps @ 120VAC
6 Amps @ 277VAC
1/8 HP @ 120/277VAC
5 Amps @ 30VDC
Physical
Mounting: Panel Mounting
4 Inserts for 2 Mounting DIM,
Torq Mounting Screws to 18in/lb.
Termination:
5mm Pluggable Block
Packaging: Gasketed Bezel
Weight: 1 Pound
Ambient Temperatures
Operating:
B - Terminal Blocks -40°C** to 59°C
**Display & membrane may not function below -20°C.
Storage: -40°C to 85°C
2.9" 2.81"
2"
MS
–
Supply
Voltage
+
3.88"
.88"
Special
XXXX - Special
Termination
B - Terminal Blocks
0.2" Dia.
2.5"
2.81"
L1
L2
L3
L1
L2
NC
NO
–
Supply
Voltage
+
MS
3" Dia.
2.5"
MS