Rittal 3144.000, 3145.000 Assembly And Operating Instructions Manual

Tangential fans for
Assembly and operating instructions
3144.000
3145.000
482,6 mm (19”)

Contents

Contents ................................................... 2
1 Application ....................................... 3
2 Safety instructions ........................... 3
3 Note on the ErP directive ................. 3
4 Transport, storage ........................... 3
5 Mounting .......................................... 4
6 Electrical connection ........................ 4
7 Operating conditions ........................ 4
8 Start-up ............................................ 4
9 Maintenance, repair ......................... 5
10 Cleaning .......................................... 5
Contents
11 Disposal / recycling .......................... 6
12 Dimensions ...................................... 7
Application
EN
The fans may only be operated when they are installed as intended, and when safety is ensured by safety
protection measures.
For motors without a temperature monitor, a

1 Application

Cross flow fans (type designation see rating plate) are not ready-to-use products, but designed as components for aerodynamic devices, machines and installations.
equipment according to DIN EN ISO 13857 (DIN EN ISO 1210 0) or b y oth er
motor cut-out switch is to b e used for P1 > 750 W (P2 500 W)!
Blocking or braking the fan by, say, pushing objects into it is forbidde n. This leads to heat ed surfaces and damage to the impeller.
It is not possible to exclude a residual risk due to incorrect use, malf unction or force majeure. The designer or constructor of the installation must take suitable safety measures in accordance with DIN EN 12100, e.g. protec tion devices, in order to prevent hazardous situations arising.
Cross flow fans are suited to a wide range of applications due to their slim construction design. They stand out against other fans particularly by virtue of their broad laminar air band with favourable noise res ponse.
Speed control through voltage reduction is possible, depending upon the application.
All fans are dynamically balanced on two planes in accordance with DIN ISO 1940, Section 1.

2 Safety instructions

The cross flow fans are only intended for the transfer of air or air -like mixtures. They ca nnot be used in hazardous ar eas for the transfer of gas, mist vapours or mixtures . Nor can the y be used for the transfer of s olid components i n the transfer medium.
Mounting, electrical connection and commissioning may only be carried out by trained specialized p ersonnel who observe the relevant regulations!
The fan is only to be operated within the ranges specified on the type plate!
Use the fan only in the authoris ed fashion and only for the tasks and flow media specified in the order!
Designer, manufacturers or operators are responsible for proper and safe installation as well as for safe operation!
Safety features, e.g. guard gr illes, are no t to be dismantled, circumvented or made inoperative!
If thermal protector is integrated into winding as motor protection, the thermal protectors must be connected.
If the temperature monitor is not integrated into the motor circuit (wiring diagram), a tripping device is required.

3 Note on the ErP directive

Rittal GmbH & Co. KG wishes to point out that, based on the directive (EU) no. 327/2011 of the Commission of 30th of March 2011 for enforcing directive 2009/125/EC (hereinafter referred to as ErP directive), the operat ional area of certain fans within the EU is bound by certain prerequisites. The fan may only be used within the EU when it m eets the requirements of the ErP directive. If the said fan does not have a CE mark (cf. especially the rating plate), use of this product within the EU is not admissible. All ErP-relevant information comprises measurements which are determined using a standardised measurement set-up. More details can be obtained from the manufacturer.

4 Transport, storage

Wear safety shoes and gloves for handling!
Transport the fan(s) either in the original packaging or using the transport fixtures provided (mounting br ackets and bored holes). Use suitable lifting equipment, insofar as required by the dimensions or weight.
Do not transport the fan by the connecting cable!
Avoid excessive vibration and shocks.
Be on the alert for any damage to the
packaging or the fan.
Store the fan in the origina l packaging in a dry area protected from the weather or protect it from dirt and weather until final installation.
Avoid exposure to extreme heat and cold.
Avoid excessive storage periods (we
recommend a one year max.) and inspect the motor bearings for proper operation prior to installation.
Assembly and operating instructions Tangential fans 3