Rittal 3105.310, 3105.320, 3105.340, 3105.350, 3105.360 Assembly And Operating Instructions Manual

...
Montage-, Installations- und Bedienungsanleitung Assembly and operating instructions Manuel d’installation et de maintenance Montage- en bedieningshandleiding Montage- och hanteringsanvisning Istruzioni di montaggio e funzionamento Instrucciones de montaje
Schaltschrank-Heizgerät SK Panel heater SK Resistance chauffante SK Schakelkastverwarmingen SK Värmeelement
för apparatskåp SK Riscaldatore anticondensa SK Resistencia calefactora SK
SK 3105.xxx
5
Notes
Enclosure heaters with fans
Model No. SK 110 V 3105.410 3105.420 3105.430 Model No. SK 230 V 3105.380 3105.390 3105.400
Dimensions mm
W
H D
103 200 103
103 200 103
103 200
103 Hole distance mm 171 Rated operating voltage V, Hz 110 or 230 V, 50/60
Continuous thermal output at T
u
= 10 ûC
250 W
1)
400 W
1)
800 W
1)
Pre-fuse gG for 110 V 4 A 6 A 10 A Pre-fuse gG for 230 V 4 A 6 A 6 A
1)
Output with fan.
We reserve the right to make technical modifications.
A
Enclosure heaters without fans
Model No. SK 3105.310 3105.320 3105.330 3105.340 3105.350 3105.360 3105.370
Dimensions mmWH
D
45 120 46
45 120 46
64 155 56
64 155 56
64 230 56
90 165 75
90 180
75 Hole distance mm 42 60 Rated operating
voltage Volt, Hz
110 – 240 V, 50/60
Continuous thermal output at T
u
= 10 ûC
8 – 10 W 18 – 20 W 23 – 30 W 49 – 50 W 63 – 75 W 86 – 100 W
130 – 150 W
Pre-fuse T 2 A 4 A
Special voltages available on request. We reserve the right to make technical modifications.
A
1. Technical speciÞcations
2. Mounting
The panel heater is fitted vertically, i.e. with the connection terminal or fan facing down­wards. To permit the required convection, a minimum clearance to the adjacent compo­nents must be observed. A safety clearance of at least 300 mm must be left above the heater in the case of heaters with fans, and 100 mm for heaters without fans. (For both a thermal safety clearance to the sides of 60 mm and 100 mm at the bottom is required). If these clearances are observed, the ambi­ent temperature does not rise above 65 ˚C.
2.1 Snap-type fastening onto a 35 mm support rail DIN EN 50 022 (Fig. 1.1).
2.2 Screw fastening onto the mounting plate (Fig. 1.2).
It should be ensured that the heater and con­nection cables are mounted firmly and secu­rely. Electric cables must not touch the body of the heater fan and must not be routed directly past the hot air outlet. The heater must not be mounted in the vici­nity of flammable materials.