Ritron RRX-460w, RRX-ACC, RRX-GCI, LT4200 LTR, LT4900 LTR Application Note

...
APPLICATION NOTE
RRX-450/ 452/ 460 w/ RRX-ACC and RRX-GCI Cables
Hookup to CSI Model LT4200/ 4900 LTR Controllers
RRX-CGI CABLE COLORS
DRAIN (N/ C)
(BLU/ WHT)
ORG/ BLK
RED
BLK ORG WHT GRN
BLU
(BLU/ WHT)
N/ C
N/ C
N/ C
N/ C
CSI
CONNECTOR
1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10 10 11 11 12 12
REPEAT DISABLE (GND) +12VDC IN (3 AMP PICO FUSE IN RRX) GND TX AUDIO OUT PTT/ TX CMD OUT RX/ DISC AUDIO IN SUBCODE/ LTR DATA OUT COS (CARRIER SQ BRK = 0 V), OPTIONAL
J1
P1
CSI INTERNAL JUMPERS
JP8
JP9 JP10 JP11 JP12 JP13 JP14 JP15 JP16 JP17 JP18
"IN" = TX NORMAL "OUT" = RX INVERTED "IN" = LTR DC OUTPUT "GND" for TX KEY OUT Set for "INT SQ" = OUT OUT OUT = +20 dB IN IN IN
1
NOTE:
Preset all pots to 12 o'clock, a close approximation of final settings.
LCD READOUT
FRONT OF CSI UNIT
CSI MODEL LT4200/ 4900 -- LEFT SIDE
Follow CSI instructions to set all audio levels.
1
DO NOT ground the Shield/ Drain Wire at the Controller end; leave it grounded at the RRX only.
RRX-450/-452/-460 JUMPER SETTINGS (Same as factory settings)
PJ401 PJ402 PJ403 PJ404 PJ405,PJ406 Not Installed PJ407
NOTES:
1. A 1K resistor installed in RRX J401 (Pin 4 to Pin 7), turns OFF the RRX internal CTCSS/ QC encoder when RRX-CGI
is connected to P1, pin 1, as shown. DO NOT set RRX R423 to 0 (zero). (This does not disable the DQC encoder.) The RRX must be set for a (any) QC code AND the "RP-200" field must be set to "Y"es.
2. If PJ404 is left in "A" position, either unplugging the RRX-GCI cable OR lifting the ORG/BLK wire from GND will automatically revert an RRX Repeater to normal (QC) Repeater mode, as programmed. When it is re-connected, the QC encoder will again be automatically disabled (i.e.: no RESET required).
3. Verify/ set RRX R426 (VOICE DEV pot), reduced to 4.0/1.7 kHz microphone voice deviation limiting to allow for 1.0/0.8 kHz of LTR data deviation. Then adjust the CONTROLLER pots to attain these levels. Leave all other RRX potentiometers at factory settings.
Publication 14540013 Rev. A 00-01
A B A A
B
Ph: 317-846-1201; 1-800-USA-1-USA (1-800-872-1872
WEB: www.ritron.com • E-mail: ritron@ritron.com
BEEP GENERATOR NORMAL INTERNAL AUDIO FILTER SELECT (HIGH PASS) AUDIO PATH TO TONE DECODER REPEAT DISABLE NOT SELECTED HERE (See Note 2)
"CD" CARRIER DETECT (LO) TO BLU/ WHT WIRE
)
Fax: 317-846-4978
Loading...