Ritchie Combination Series, AC Series, Cattle Series, 5E Cattle, 3 Combination Installation Instructions Manual

...
Installation Instructions for
Cattle Fountain Series,
Combination Fountain
Series, & AC Series
Congratulations, you have just purchased the finest watering fountain
on the market. This unit is built to give you excellent service when
properly installed and maintained. Please follow instructions
carefully. Read and understand all instructions before installing.
Part # 17837
17 October, 2012
Cattle Fountain, Combination Fountains, AC Series
Cattle, Combination, and AC Series Fountains Installation Instructions
1
17 October, 2012
Installation Instructions
A. Location - Putting the fountain in a location that offers protection from the wind will enhance the performance of the fountain. Livestock will tend to gather in this protected area, enticing them to drink more. Access panel should be opposite of prevailing winter wind to give additional protection to the supply line.
B. Water Supply Line - Ho rizontal underground water line (1) should be sized to account for pressure drop, relating to distance, and placed well below frost line. A one-inch vertical supply pipe (2) is recommended. A shut­off valve (3) should be installed under fountain to allow for easier servicing. For optimum serviceability, a stop and waste valve can be installed below frost level to drain water back when unit is not in use. Vertical supply line must be centered in riser tube (4) to provide an air space between the line and frozen ground outside of tube. Flush water supply line thoroughly before connection to fountain. Water supplies with foreign material such as sand, rust, etc. may require a filter to keep fountain valve working properly.
C. Electric Supply – It is usually most cost effective to run your electrical line the same time you are trenching your water supply. Any electrical service must be installed and maintained by a qualified electrician.
D. Riser Tube - Install a riser tube and extend it at least one foot below frost line or down to horizontal underground water line. For optimum water line protection, use the 12” diameter insulated Ritchie Thermal Tube, part numbers and sizes are shown to the left. Tube opening must be kept clear. NOTE: The supply line
touching the riser tube is the most common cause of the supply line freezing. Do not surround the supply line with insulation, wood, or other foreign material. Any foreign material in the tube may cause frost to migrate to the supply line causing it to freeze.
Ritchie Thermal Tube
Part # Description
18158 1’ Top Section 16417 2’ Top Section 16612 4’ Top Section 16416 2’ Extension
Use in combination to reach desired depth
E. Mounting Platform - A concrete platform must be provided for all fountains. Use a minimum of 4” thick,
Cattle, Combination, and AC Series Fountains Installation Instructions
2
17 October, 2012
(6” recommended), large enough to accommodate fountain, and additional 4” step (on top of the platform) extending 18” out from each side of the unit. This will protect the unit from manure handling equipment, as well as discouraging animals from defecating in the fountain. Extending the platform provides animals a place to stand while drinking, consider the size of your animals when determining the dimensions of your platform. The concrete step and platform should slope away from the fountain for drainage. A rough broom finish to concrete surface provides better footing for livestock.
F. Hose Connection - Connect hose fitting to shut-off valve at top of concrete. Slip on barb fitting with furnished clamps. Hose should not touch insulation or outside surface of fountain. Place the hose under the fountain as you move the unit in place over the riser tube.
G. Anchoring Fountain - Steel fountains are provided with four hold-downs to anchor your unit securely to the concrete. Screw the hold down angles on to the unit then anchor down the unit. Use of 3/8” x 3-1/2” stainless steel expansion anchor bolts (not included) is recommended for concrete installations. Anchor bolts are available from Ritchie in a two pack, part # 14261. Use an all-weather sealant under the outside edge when anchoring to concrete to keep air from leaking under fountain.
H. Final Water Connection– Connect the top of the supplied hose to the valve, cut hose to proper length and slip onto the barb fitting of the valve assembly. Clamps and fittings are furnished to secure the connection.
I. Cable Heater – Uncoil cable heater and loop around the valve. Attach the remaining part of the cable heater to the water supply, as far down the riser tube as possible, with the cable twist ties provided. (See drawing on previous page.) This heater is water tight, but should not be immersed in water.
CAUTION: Installation must not cause any strain on heater wiring connections. Do not cross the cable over itself along the water line. Avoid heater damage caused by hot spots due to its leads lying close to each other. Do not wrap additional insulation around heater.
J. Electrical Connection - The electrical installation should be made and maintained by a qualified electrician conforming to national and local codes.
accordance with the wiring rules. A suitable fuse or circuit breaker with properly sized wire must protect the 3-wire power to the fountain. For wiring connections, see wiring diagram. Do not by-pass the terminal block to power unit. Make connections according to the wiring diagram below.
A means for disconnection must be incorporated in the fixed wiring in
WARNING: DISCONNECT POWER IF THE WATER SUPPLY IS TO BE SHUT OFF FOR AN EXTENDED AMOUNT OF TIME. FAILURE TO TURN OFF POWER CAN RESULT IN DAMAGE TO THE WATERING FOUNTAIN.
NOTE: National/Local electrical codes may require livestock waterers installed in feedlots in open feeding area to
Cattle, Combination, and AC Series Fountains Installation Instructions
3
17 October, 2012
be grounded by a separate stranded copper grounding conductor or at least no.6 AWG terminating at a point where the branch circuit receives its supply. Chec k with local authorities.
FENWAL THERMOSTAT
CABLE HEATER
GROUND LUG
HEATER 120V
HEATER 120V
DISC THERMOSTAT
OR
TERMINAL BLOCK
(BLACK)
POWER SUPPLY
SINGLE PHASE 120V
WARNING This installation must be made and maintained in strict conformity with National/Local plumbing codes and National/Local electrical codes (CSA in Canada). The applicable provisions of these codes take precedent. Failure to make and maintain all installations properly may result in loss of livestock, personal Injury, or death.
FENWAL THERMOSTAT
Cattle, Combination, and AC Series Fountains Installation Instructions
4
17 October, 2012
CABLE HEATER
GROUND LUG
HEATER 240V
HEATER 240V
DISC THERMOSTAT
OR
TERMINAL BLOCK
(WH IT E )
POWER SUPPLY
SINGLE PHASE 240V
K. Terminal Block – The terminal block is provided for easy and quick connection to the power source. The push buttons provide quick connection with a screwdriver or by hand. If you are using solid wire then you will be able to just push the wire into the slot. Stranded wire will require you to press the button down.
L. Fenwal Thermostat (Cattle Fountains and Combination) - The adjustable range
Cattle, Combination, and AC Series Fountains Installation Instructions
5
17 October, 2012
is from 0
o
. F (-18o C) to 100o F (38o C). Thermostat is not preset at factory. Fill the trough to proper water level. Check the water temperatur e with a thermom eter. The next morning, check the water temperature again. If the water is warmer than desired, turn the thermostat down. If there is ice forming on the surface of the water, turn the thermostat up. Only slight adjustments should be made to the thermostat at any time. A 1/16 turn on the thermostat will change the water temp. 7
o
F (4o C). 44o F (7o C) in the trough represents the most economical operation. Counter clockwise raises the thermostat setting.
M. Disc Thermostat (AC Series) – The disc thermostat is mounted in a bracket under the trough, which allows it to be moved relative to the heater. To ease movement of thermostat turn ¼ turn. To lock in position after adjustment turn ¼ turn back. As the thermostat is moved toward the heater, the water temperature in the trough is lowered. The best location is determined by checking the trough temperature several times during the heating season.
N. Drain Plug – Insert the drain plug firmly into the drain hole in the center of the trough.
O. Float Adjustment – Open water-supply shut-off valve, check for and fix any leaks. Adjust float for a water depth of 2 inches below top of trough or overflow pipe by adjusting the thumbscrew or wing nut.
P. Install Side Access Panel and Cover – Once all water line connections have been checked for leaks and electrical hook-up is complete, the side access door may be installed. With the valve functioning properly and the water level set at the proper level, you may install the valve cover.
Q. Children should be supervised to ensure that they do not play with the appliance – This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instructions concerning use of the appliance by a person responsible for their safety.
R. Cleaning Your Fountain – To clean your watering fountain you will need a good stiff bristled brush. Remove the cover then brush the valve area to remove any build-up then brush the tank. Remove the plug that is located in the valve chamber area under the float to drain out the water and debris. You can shut off the water with the shut-off valve located under the unit or by holding the float in the up position. After the water and debris has drained reinstall the plug and let the tank refill. Now is a good time to readjust the float if needed. Reinstall cover and you are done.
Cattle, Combination, and AC Series Fountains Installation Instructions
6
17 October, 2012
Ritchie Valves
Ritchie valves come in two sizes and four pressure ratings – blue for very high pressure, green for high supply line pressure, red for moderate supply pressure, and white for low-pressure applications. Differences in the size of trough also impacts valve choice. Although different pressure rated valves may be used in a fountain, each fountain will only accommodate one size and configuration of valve. If water pressure is over 60 psi, and if the valve does not shut off, a pressure-reducing valve may be needed. Your individual situations may require a change from the standard valve supplied with your fountain, see your Ritchie Dealer if this is needed.
1/2” Part # GPM Pressure Range White 12574 4.8 Low, 5-40 psi. Red 12575 3.4 Moderate, 40-60 psi. Green 13597 1.45 High, 60-80 psi.
3/4” Part # GPM Pressure Range White 16697 33 Low, 5-40 psi. Red 11101 20 Moderate, 40-60 psi. Green 15377 16.5 High, 60-80 psi. Blue 18197 5 Ve r y H igh, 80-1 00 psi.
NOTE: Four orifice sizes are available for multi-purpose fountains and two sizes are available for cattle fountain
valves. They are color-coded.
Ritchie Limited Warranty
Ritchie Industries, Inc. warrants its products to be free of defective materials and workmanship. Defective part(s) will be repaired or replaced at the option of Ritchie Industries.
This warranty specifically excludes all labor and shipping charges.
This warranty does not apply to any appearance items, to any product whose exterior has been damaged or defaced, to any product that has been improperly installed, to any product subjected to misuse, abnormal service or handling, and to any products altered or repaired with other than original equipment or manufacturer’s parts.
This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
All warranty claims must be processed through an Authorized Ritchie Dealer/ Distributor. Proof of purchase is required. This warranty is not transferable. The period of warranty begins at original date of purchase as follows:
Poly Units
Base, top and ball closures
10 year limited against manufacturing defect. 100% first five years, then declining 20% per year for the remaining five years.
Stainless Steel Units
Stainless trough and stainless valve chamber frame:
Ten years against manufacturing defect or corrosion. 100% all ten years.
Casing and cover:
10 year limited against manufacturing defect. 100% first year, then declining 10% per year for the remaining nine years.
Component Parts
All component parts, such as floats, valves, heating elements:
One year from the date of purchase against manufacturing defect, 100%.
Hydrants
All component parts:
One year from the date of purchase against manufacturing defect, 100%.
Effective September 2012
Trouble Shooting
Cattle, Combination, and AC Series Fountains Installation Instructions
7
17 October, 2012
Problem Solution
Water in Trough Too Warm
Ice in Trough
Valve Freezing
Supply line Freezing
Valve won’t stop dripping
Low water flow
Adjust thermostat to lower temperature Check to see if thermostat has failed by contacts burning closed
Check fuses or circuit breakers Check all heating elements to make sure they are working and hot Adjust thermostat to higher temperature Check for voltage from thermostat output Check voltage to fountain with and without electrical load
Check that heaters are wired properly Check that cable heater is installed properly and fastened to water supply line and is
working when heaters are hot Check for missing or damaged insulation
Check for air gaps for wind penetrations Check that the cable heater is uncoiled and fastened around valve, to supply line
and is working when heaters are hot Check that supply piping is centered in riser tube Check that riser tube is free of water and mud that may freeze Check that flexible hose does not touch side of casing or frame Check casing for air leaks Check for air gaps between casing and concrete floor Check float adjustment. Check for waterlogged float, or float rubbing on side of valve compartment Disassemble valve and check for sand or
Valve
scale in valve rubber. Also check valve orifice outlet for wear and damage. A screen or filter my be required with sandy or scaly water Turn valve rubber over and re-assemble Check for excessive water system pressure Check that valve inlet is not plugged or supply hose is not kinked Check system pressure from supply hose by installing a tee and a pressure gauge directly in front of the valve to check pressure drop when valve is open. A severe pressure drop indicates a restriction or undersized supply system. Check that shutoff valves are fully open
1/2”
Valve Rub ber
Pin must b e pu sh e d ou t of va l v e
to dissemble
3/4”
Valve
Valve Rubber
#5E Cattle Fountain
Cattle, Combination, and AC Series Fountains Installation Instructions
8
17 October, 2012
Part # 16745
1
8
2
9
20
15
16
4
7
3
5
Item
Part #
11
Description Qty
10
12
13
19
14
6
Item
1 13374 5E Cover 1 15 11514 2 16590 3 13823 4 16746 5
11154 Access Pnl 17"x20" Assembled 1 18 16993 6 15299 7 16534
18320
18074 8 15154 9 18114
10 18628 11 11419 12 18075 13 11473 14 16629
5E Frame
1 16 15377
5E Casing Pkg 1 pkg 5E Trough pkg 1 pkg
Bolt 3/8"x1/2" SS (4/pkg) 1 pkg Fenwal Thermostat SS pkg 1 pkg O-Ring Fenwal (6/pkg) 1 pkg Nut Brass Fenwal (6/pkg) 1 pkg Screw 1/4"x5/8" TC SS (10/pkg) 1 pkg Trough Bolt & Nut (5/pkg) 1 pkg Drain Plug (2/pkg) 1 pkg Heater 120V 250W (1/pkg) 2 pkg Drain Washer (6/pkg) 1 pkg Drain Pipe with Elbow
1 NS 11403
Standpipe pkg 1 pkg
17 18314 18313
19 13775 20 16975 NS 12583 NS 13830 NS 15632
NS 13790 NS 11107
16824 5E 240V
NS 16424
Part #
18
17
Description Qty
Valve Bracket 3/4" pkg 1 pkg Green Male Valve 3/4" pkg 1 pkg Float with Hardware pkg 1 pkg Hardware for Float pkg 1 pkg Green Valve & Float pkg 1 pkg Hold Down Angle SS (4/pkg) 1 pkg Flipper/Hinge (2/pkg) - Optional
1 PKG
Valve Supply Line pkg 1 pkg Cable Htr 120V 48W (1/pkg) 1 pkg 5E Casing Insulation pkg 1 pkg 5E Frame Inulation pkg 1 pkg 5E Accessory pkg 1 pkg
Heater 240V 300W (1/pkg) 2 pkg Cable Htr 240V 48W (1/pkg) 1 pkg
#3E Cattle Fountain
Cattle, Combination, and AC Series Fountains Installation Instructions
9
17 October, 2012
Part # 16743
13
8
2
9
4
12
3
5
1
20
15
16
10
14
11
7
18
17
19
6
Item
Part #
Description Qty
Item
Part #
1 13373 3E Cover 1 15 11514 2 16589 3E Frame 1 16 15377 3 12657 4 16744 5
11154 Access Pnl 17"x20" Assembled 1 18 16993 6 15299 7 16534
18320
18074 8 15154 9 18114
10 18628 11 11419 12 18075 13 11472 14 16629
3E Casing Pkg 1 pkg 3E Trough pkg 1 pkg
Bolt 3/8"x1/2" SS (4/pkg) 1 pkg Fenwal Thermostat SS pkg 1 pkg O-Ring Fenwal (6/pkg) 1 pkg Nut Brass Fenwal (6/pkg) 1 pkg Screw 1/4"x5/8" TC SS (10/pkg) 1 pkg Trough Bolt & Nut (5/pkg) 1 pkg Drain Plug (2/pkg) 1 pkg Heater 120V 250W (1/pkg) 2 pkg Drain Washer (6/pkg) 1 pkg Drain Pipe with Elbow
1 NS 11403
Standpipe pkg 1 pkg
17 18314 18313
19 13775 20 16974 NS 12583 NS 13830 NS 15634
NS 13789 NS 11107
16826 3E 240V
NS 16424
Description Qty
Valve Bracket 3/4" pkg 1 pkg Green Male Valve 3/4" pkg 1 pkg Float with Hardware pkg 1 pkg Hardware for Float pkg 1 pkg Green Valve & Float pkg 1 pkg Hold Down Angle SS (4/pkg) 1 pkg Flipper/Hinge (2/pkg) - Optional 1 pkg Valve Supply Line pkg 1 pkg Cable Htr 120V 48W (1/pkg) 1 pkg 3E Casing Insulation pkg 1 pkg 3E Frame Inulation pkg 1 pkg 3E Accessory pkg 1 pkg
Heater 240V 300W (1/pkg) 2 pkg Cable Htr 240V 48W (1/pkg) 1 pkg
#3 Combination Fountain
Cattle, Combination, and AC Series Fountains Installation Instructions
10
17 October, 2012
1
Part # 16769
15
16
12
13
3
5
8
2
9
4
10
11
7
11
10
29
20
28
14
27
26
25
24
18
17
Item Part #
19
6
21
Description Qty
Item Part #
12
22
1 13373 3C Cover 1 18 16993 2 16589 3C Frame 1 19 13775 3 12656 4 16744 5
11154 Access Pnl 17"x20" Assembled 1 22 11472 6 15299 7 16534
18320
18074 8 15154 9 18114
10 18628 11 11419 12 18075 13 18603 14 16629 15 11514 16 15377 17 18314
18313
3C Casing Pkg 1 pkg 3C Trough pkg 1 pkg
Bolt 3/8"x1/2" SS (4/pkg) 1 pkg Fenwal Thermostat SS pkg 1 pkg O-Ring Fenwal (6/pkg) 1 pkg Nut Brass Fenwal (6/pkg) 1 pkg Screw 1/4"x5/8" TC SS (10/pkg) 1 pkg Trough Bolt & Nut (5/pkg) 1 pkg Drain Plug (2/pkg) 1 pkg Heater 120V 250W (1/pkg) 3 pkg Drain Washer (6/pkg) 1 pkg Drain Fitting Flared
1 NS 15633
Standpipe pkg 1 pkg Valve Bracket 3/4" pkg 1 pkg Green Male Valve 3/4" pkg 1 pkg Float with Hardware pkg 1 pkg Hardware for Float pkg 1 pkg
20 16974 21 16767
23 12404 Grate - Clean out 2 24 12801 25 13166 26 11118 3C Innerhood 2 27 11515 Valve Bracket 1/2" w/ screws
28 12575 Red Valve 1/2"
29 13613 Float with Short Arm NS 12583 NS 13830
NS 13789 NS 18326
16816 3C 240V NS 11403 NS 16424
23
Description Qty
Green Valve & Float pkg 1 pkg Hold Down Angle SS (4/pkg) 1 pkg Flipper/Hinge (2/pkg) - Optional 1 pkg 3C Lower Trough SS Drain Pipe with Elbow
Swing Door w/Rod Rod with Nut for Swing Door
1 1
2 2
1 pkg 1 pkg
1 pkg Valve Supply Line pkg 1 pkg Cable Htr 120V 48W (1/pkg) 1 pkg 3C Casing Insulation pkg 1 pkg 3E Frame Inulation pkg 1 pkg 3C Accessory pkg 1 pkg
Heater 240V 300W (1/pkg) 2 pkg Cable Htr 240V 48W (1/pkg) 1 pkg
2AC
Cattle, Combination, and AC Series Fountains Installation Instructions
11
17 October, 2012
Part # 18033
1
2
20
8
4
15
14
16
9
13
3
5
Item Part #
12
11
19
Description Qty
10
7
6
Item Part #
1 13379 2AC Cover 1 15 11515 2 13449 3 18035 4 18036 5 12140 6 15299 7 11885 8 15158
9 17500 10 18628 11 14150 12 18075 13 11471 14 16866
2AC Frame pkg 2AC Casing 2AC Trough Access Panel 8" Assembly Bolt 3/8"x1/2" SS (4/pkg) Disc Thermostat pkg 1 pkg J-Bolt & Nut ZP (10/pkg) Drain Pipe Guard Drain Plug (2/pkg) Heater 120V 125W (1/pkg) Drain Washer (6/pkg) Drain Pipe with Elbow Standpipe pkg
1 pkg 1 pkg 1 pkg
16 15154 17 12575 18 13613
1 19 13775
1 pkg
20 16973 NS 13830
1 pkg
NS 18323
1 NS 15652
1 pkg 2 pkg 1 pkg
NS 13850
16839 2AC 240V
1 NS 16664
1 pkg
NS 16424
17
18
Description Qty
Valve Bracket 1/2" w/ Scrws pkg Screws Valve Bracket (6/ pkg) Red Valve 1/2" pkg Float with Short Arm pkg Hold Down Angle SS (4/pkg) Flipper/Hinge (2/pkg) - Optional Cable Htr 120V 48W (1/pkg) 2AC Accessory pkg 2AC Casing Insulation pkg 2AC Frame Insulation pkg
Heater 240V 200W (1/pkg) Cable Htr 240V 48W (1/pkg)
1 pkg 1 pkg 1 pkg 1 pkg 1 pkg 1 pkg 1 pkg 1 pkg
1 plg
1 pkg
2 pkg 1 pkg
2AC Special Assembly
Cattle, Combination, and AC Series Fountains Installation Instructions
12
17 October, 2012
1
2
Part # 18043
9
8
4
13 12
3
11
20
15
10
16
7
18
6
17
14
5
19
Item Part #
Description Qty
Item Part #
1 13379 2AC Cover 1 15 11515
2 13449
3 18058
4 18036
5 12140
6 15299
7 11885
8 15158
9 17500 10 18628 11 14150 12 18075 13 11471 14 16866
2AC Frame pkg 2AC SP Casing 2AC Trough Access Panel 8" Assembly Bolt 3/8"x1/2" SS (4/pkg) Disc Thermostat pkg 1 pkg J-Bolt & Nut ZP (10/pkg) Drain Pipe Guard Drain Plug (2/pkg) Heater 120V 125W (1/pkg) Drain Washer (6/pkg) Drain Pipe with Elbow Standpipe pkg
1 pkg 1 pkg 1 pkg
16 15154 17 12575 18 13613
1 19 13775
1 pkg
20 16973 NS 13830
1 pkg
NS 18323
1 NS 18059
1 pkg 2 pkg 1 pkg
NS 13850
18420
1 NS 16664
1 pkg
NS 16424
Description Qty
Valve Bracket 1/2" w/ Scrws pkg Screws Valve Bracket (6/ pkg) Red Valve 1/2" pkg Float with Short Arm pkg Hold Down Angle SS (4/pkg) Flipper/Hinge (2/pkg) - Optional Cable Htr 120V 48W (1/pkg) 2AC Accessory pkg 2AC SP Casing Insulation pkg 2AC Frame Insulation pkg
1 pkg 1 pkg 1 pkg 1 pkg 1 pkg 1 pkg 1 pkg 1 pkg
1 plg
1 pkg
2AC Special 240V Heater 240V 200W (1/pkg) Cable Htr 240V 48W (1/pkg)
2 pkg 1 pkg
1AC
Cattle, Combination, and AC Series Fountains Installation Instructions
13
17 October, 2012
Part # 18034
1
2
8
20
10
4
15
14
16
12
13
Item Part #
3
19
Description Qty
11
7
5
6
Item Part #
1 13379 1AC Cover 1 16 15154
2 18039
3 18037
4 18038
5 12140
6 15299
7 11885
8 15158 10 18628 11 11419 12 18075 13 11471 14 16866 15 11515
1AC Frame pkg 1AC Casing 1AC Trough Access Panel 8" Assembly Bolt 3/8"x1/2" SS (4/pkg) Disc Thermostat pkg 1 pkg J-Bolt & Nut ZP (10/pkg) Drain Plug (2/pkg) Heater 120V 250W (1/pkg) Drain Washer (6/pkg) Drain Pipe with Elbow Standpipe pkg Valve Bracket 1/2" w/ Scrws pkg
1 pkg 1 pkg 1 pkg
17 12575 18 13613 19 13775
1 20 16973
1 pkg
NS 13830 NS 18323
1 pkg 1 pkg 1 pkg 1 pkg
NS 15651 NS 13850
16841 1AC 240V
1 NS 11403
1 pkg 1 pkg
NS 16424
17
18
Description Qty
Screws Valve Bracket (6/ pkg) Red Valve 1/2" pkg Float with Short Arm pkg Hold Down Angle SS (4/pkg) Flipper/Hinge (2/pkg) - Optional Cable Htr 120V 48W (1/pkg) 1AC Accessory pkg 1AC Casing Insulation pkg 1AC Frame Insulation pkg
Heater 240V 300W (1/pkg) Cable Htr 240V 48W (1/pkg)
1 pkg 1 pkg 1 pkg 1 pkg 1 pkg 1 pkg 1 pkg
1 plg
1 pkg
1 pkg 1 pkg
Hold Down Anchor Bolt Locations
Cattle, Combination, and AC Series Fountains Installation Instructions
14
17 October, 2012
Fountain Model Part # Hole to Hole Location
3 Cattle Fountain 16743 15-1/2” x 30” 5 Cattle Fountain 16745 18-1/8” x 38-1/2” 3 Combination Fountain 16769 15-1/2” x 30” 1 AC 18034 8-1/2” x 18” 2 AC 18033 8-7/16” x 26-3/8” 2 AC Special 18043 8-7/16” x 26-3/8”
Note: Do not drill holes for anchors before location can be verified with unit.
Anchor Bolt Locations