Risco RWX312PR4 Users Manual

Two Way Wireless PIR Outdoor Detector
WL X312
Installation Instructions
2 Installation Instructions
Table of Contents
Installation ..............................................................................................................................4
Introduction ............................................................................................................................4
Mounting.................................................................................................................................4
Mounting Considerations......................................................................................................4
Wall Mount Installation.........................................................................................................6
Flat Mounting .......................................................................................................................6
45° angle Mounting (Left side mounting) .............................................................................. 6
Changing Back Tamper position ..........................................................................................7
Back Tamper Terminal Wiring...............................................................................................7
Configuration Parameters......................................................................................................7
Detection Length Adjustment................................................................................................8
Walk test .................................................................................................................................9
LEDs Display ..........................................................................................................................9
Operational Modes ................................................................................................................. 9
Transmitter/Receiver Communication link setup.................................................................9
Standard Swivel Installation (Optional)...............................................................................10
Wall Mounting ....................................................................................................................10
Replacing Lenses.................................................................................................................12
Technical Specification........................................................................................................ 13
Ordering Information............................................................................................................ 13
Accessory Kits ..................................................................................................................... 13
Installation Instructions 3
Installation
Introduction
RISCO Group's WL X312 is a unique detector with signal processing based on two Passive Infrared (PIR) channels. The WL X312 has an adjustable detection range. The detector is compatible with all RISCO Group Wireless and Hybrid systems. The following instructions describe the installation of the WL X312.
Mounting
Mounting Considerations
1. Installation Height: 0.8m - 1.2m
(2'8" – 3'11") Typical Installation Height: 1m (3'3")
2. To ensure maximum operational reliability, install the detector perpendicular to the ground so
that the upper detection area is parallel to the ground.
3. For optimum detection, select a location that is likely to intercept an intruder moving across the coverage pattern.
With moving objects keep distance of
4. Avoid pointing the detector to moving
objects (swaying trees, bushes etc.)
4 Installation Instructions
minimum 5 meters (16')
5. Ensure any objects do not obstruct the field
of view. Pay attention to growing trees or bushes, plants with big moving leaves etc.
5m (16')
Out of
Detection Range
Installing the WL X312 detector in challenging situations
In the following situations, rapid and significant infrared radiation changes can happen in both PIR channels together, resulting in false alarms and therefore care should be taken.
1. Situations in which metal and/or glass objects measuring over 70cm (2’4”) in height from the
ground are in the field of view of the detector (cars, metal gates, shutters, metal walls, windows, etc.)
2. Situations in which a reflective surface on the ground larger than 1m (3’4”) in diameter may
cause reflection into the detector’s lens. Examples of a reflective surface on the ground are a puddle, wet road or car park, smooth concrete or asphalt surface, swimming pool, etc.
Water R eflection
NOTES:
1. Please note that any outdoor PIR detector will require reduction in range to a shorter distance than the car, metal object or surface reflection (so that these objects won’t be protected) in order to eliminate false alarms.
2. For full 15m (50’) coverage in the above situations, it is highly recommended to install the wired WatchOUT DT, the only outdoor detector with 2 PIR channels and 2 Microwave channels.
3. Wireless WatchOUT detectors include high quality Silicon filters on the PIR sensors for blocking out white light interferences. These filters are not intended to block infrared thermal radiation.
Installation Instructions 5
Wall Mount Installation
NOTE
:
The installation knockouts numbering are marked on the back plate.
1. Open the WL 312 front cover (unlock C1, Figure 1).
2. Release internal base (unlock I1, Figure
2).
3. Select mounting installation as follows:
Flat Mounting:
Open knockouts on external base (Figure
3).
B1 - B4: Wall mounting knockouts
T1: Back tamper knockout
45° angle Mounting (Left side mounting):
a. Open knockouts on external base
(Figure 3).
L1, L2: Left mounting knockouts
T3: Left tamper knockout
b. Remove tamper spring (Figure 4).
c. Replace tamper bracket (Item 1) with
supplied flat tamper bracket (Item 2).
Item 1
Item 2
Figure 1
Figure 3
Tamper
Lever
B
A
W5
W6
W3
Figure 2
C1
T1
T3
L1
B1
T6
I1
T5
T4
T2
R1
(not visible)
B2
W9
W2
d. Insert Tamper lever B onto T6 and T3
and secure screw A (Figure 3).
4. Secure external base to the wall.
5. Insert tamper wires through internal base (Figure 4).
L2
B4
Figure 4
R2
(not visible)
B3
6. Secure internal base to external base (lock I1, Figure 2).
7. Close the front cover (Lock C1, Figure 1) after wiring and setting DIP switches.
8. Walk test the detector.
NOTE:
For 45° right side installation use the equivalent units on the external base as follows:
Knockouts Description
Left
Right
Mounting Knockouts L1, L2 R1, R2 Tamper spring knockouts T1,T3 T2,T4 Tamper screw anchor T5 T6