Risco eyeWAVE, eyeWAVE RWT95043300A, eyeWAVE RWX95CMP400A, eyeWAVE RWTP95043300A, eyeWAVE RWX95CM4000A Installation Instructions Manual

...
Page 1
eyeWAVE™
Wireless PIR Camera
Installation Instructions
Description
Main Features
PIR coverage 12m (40’) wide angle
VGA camera resolution with ~90° field-of-view
Discreet IR flash allows imaging in complete
darkness, up to 10m (33’)
Sequence of images upon event, configurable
number and fps
During disarm, events are ignored to save
battery and for privacy
On-demand images initiated from authorized mobile
phone or web browser
Two RF channels with separate antennas:
One for control, second channel for image
transmission
Images stored on detector until transmission to
panel complete
Includes 2 long-life 3V lithium batteries
Installation
Step1: Preliminary Considerations
1. Select the mounting location for best coverage of the area that is to be protected (see Coverage Patterns). Pay attention to the following:
Do not touch the lens with your finger as it will result in blurred image capture. Do not mount the detector in direct sunlight or near heated sources and metal objects. Detection sectors should be pointed towards either the wall or the floor and not towards windows and curtains. Select mounting height according to the coverage patterns (recommended: 2.0–2.4 m in height and at least 40cm from ceiling).
Step 2: Registering the Detector into the system
The eyeWAVE must identify itself to the system receiver in a device allocation (enrollment) process, which can be performed by either RF sequence registering or entering the detector’s 11-digit serial number into the system or using RF mode (Panel Quick Key Programming Sequence:
1) Radio Devices > 1) Allocation > 1)By RF or 2)By Code.
Refer to the Agility installation manual for full instructions.
Step 3: Mounting the detector
1. Open the knockout holes of the mounting bracket, and use them as a template for mounting according to the following table (see
Figure 1).
Mounting position
Knockout for
Left Flat Right Bracket 7,8 1,2,3,4 5,6 Tamper 9 10 11
For Pet-Friendly Model: In order to optimize pet immunity the following guide lines are recommended:
Mount the detector vertically at right angles to the floor. Make sure an animal cannot get above height of 1.5m (5') by climbing on furniture, shelving or stairs.
2. Fasten the cover to the base of the detector by inserting and fastening screw (B) into the hole located inside the battery compartment. (see Figure 3)
3. Insert the batteries and close the battery compartment cover. (see Figure 3)
4. Once the bracket is installed, slide and lock the detector onto the mounting bracket in reverse sequence. (see Figure 2)
5. Perform a Walk Test as described in the Walk Test section.
6. Insert and fasten screw (C) into the hole located at the bottom of the detector to lock the detector to the mounting bracket. (see Figure 3).
Page 2
Step 4: Walk Test
Upon inserting the batteries, the detector goes into a Walk Test mode for 20 minutes and then automatically returns to Normal mode
(To save battery power). During Walk Test Mode, the detector will transmit after each detection. Walk test the entire field view of the detector and observe the LED for confirmation. Verify that the receiver is properly receiving the signals.
Manually initiate a walk test from the control panel:
Installation Menu: 2) Testing > 2) Zone > 3) Walk Test 1) Start Walk Test The detector remains in walk test mode until any key on the panel is pressed. Display test results as follows:
Installation Menu: 2) Testing > 2) Zone > 3) Walk Test 2) Walk Test Results
Figure 1: Mounting Bracket
Figure 2: Remove detector from
Mounting Bracket
Figure 3: Insert batteries
Camera Configuration
Being bi-directional, the detectors parameters can be modified from the keypad or from the system configuration software according to your needs:
PIR Sensitivity: High/Low (Default: Low) Supervision Time: 0-255 minutes (Default: 15 min) LED: On/Off (Default: On) Operation Mode:
Walk Test: The detector will transmit after each detection Normal (Default): 2.5 minutes dead time between detections
For more information refer to the Agility Installer Guide.
Configure the camera settings through the RISCO Configuration Software or through the panel quick key programming sequence as follows (default in bold): Programming > 1) Radio Devices > 1) Allocation > 2) Modification > 1) Zone [Select (1–32)] >
1) Parameters > 6) Advanced 5) Camera Parameters:
1) Images at Alarm: 3 (1 to 7 images)
2) Image Interval: 0.5 sec (0.5, 1, 2 seconds)
3) Pre-Alarm Image: Yes (Yes, No) (Image capture upon each arm)
4) Image Resolution: QVGA (QVGA 320X240, VGA 640X480)
5) Image Quality: High (High, Low)
6) Colour Image: Colour (Colour, B&W)
Image at request
Taking a snapshot from the PIR Camera can be initiated by using SMS command from any remote phone SMS Message structure: [PIN Code][V][Camera No 01-32], example: 1234V01
Event Report
Every event detected by the PIR camera is recorded into the camera’s memory. The event record consists of the date and time mark, detail description of the event including its source and a video record.
LED Status
On: Alarm
Blinking twice: (In alarm mode) Low battery Blinking four times: (In initial learning mode) Successful write operation
Diagnostics
You can perform diagnostic tests on your detector using the Agility keypad or the Agility configuration software. Diagnostics includes testing the detector battery status and the communication between the detector and the panel. For additional information refer to the Agility Installer Manual.