CC-100 and CC-200
Center Conductor Cleaner and Scraper
Warning! This tool should not be used on liv e electrical circuits. It is not protected agai nst electrical s hock! Alway s use OSHA/AN SI/CE
or other in dustry approved eye protection when using tools. Thi s tool is not to be used for purp oses other than intended. Read carefully and
understan d instructions before using this tool.
CC 100 CC 200
Select the V-shaped notch that best matches your center conductor diameter. Place the CC-100 onto the center conductor. Clamp down and rotate
the tool around the conductor until you break the dielectric bond.
Continue to rotate while at the same time maintaining a “clamp down and pulling” motion. This procedure will ensure that you are removing all of the
dielectric from the center conductor in one easy step.
Using the same V-shaped notch, repeat this action, “stroking” the cleaner up and down along the length of the conductor two or three times to remove
any residual dielectric and adhesive.
CC 200 OPERATING INSTRUCTIONS
CC 100 OPERATING INSTRUCTIONS
Place the CC-200 onto the center conductor. Clamp down and scrape off the dielectric by pulling the tool towards the end of the cable.
Continue scraping while at the same time maintaining a “clamp down and pulling” motion. This procedure will insure that you are removing all of the
dielectric from the center conductor in five or six quick pulls. The dielectric will “scrape” off the center conductor without damaging it.
CC-100 and CC-200
Center Conductor Cleaner and Scraper
Warning! This tool should not be used on liv e electrical circuits. It is not protected agai nst electrical s hock! Alway s use OSHA/AN SI/CE
or other in dustry approved eye protection when using tools. Thi s tool is not to be used for purp oses other than intended. Read carefully and
understan d instructions before using this tool.
CC 100 CC 200
Select the V-shaped notch that best matches your center conductor diameter. Place the CC-100 onto the center conductor. Clamp down and rotate
the tool around the conductor until you break the dielectric bond.
Continue to rotate while at the same time maintaining a “clamp down and pulling” motion. This procedure will ensure that you are removing all of the
dielectric from the center conductor in one easy step.
Using the same V-shaped notch, repeat this action, “stroking” the cleaner up and down along the length of the conductor two or three times to remove
any residual dielectric and adhesive.
Place the CC-200 onto the center conductor. Clamp down and scrape off the dielectric by pulling the tool towards the end of the cable.
Continue scraping while at the same time maintaining a “clamp down and pulling” motion. This procedure will insure that you are removing all of the
dielectric from the center conductor in five or six quick pulls. The dielectric will “scrape” off the center conductor without damaging it.
CC 100 OPERATING INSTRUCTIONS
CC 200 OPERATING INSTRUCTIONS

BLADE REPLACEMENT INSTRUCTIONS
1. Remove both slotted screws from one of the body halves.
2. Remove blades and replace. Note: The identification mark must appear on the outer surface of the blade. Replace the slotted screws.
3. Repeat steps 1 and 2 for other body half.
REPLACEMENT BLADE INFORMATION
BLADES ARE INTERCHANGEABLE WITH EITHER TOOL VERSION
Notched Plexiglas Cleaning Blades P/N 16722
Straight Edge Plexiglas Blades P/N 16725
Micarta Notched Cleaning Blades P/N 16733
WARRANTY: RIPLEY warrants its products against defective materials and workmanship for a period of one
year from date of shipment from the RIPLEY factory provided the product is utilized in accordance with
instructions and specified ratings.
46 Nooks Hill Road, Cromwell, CT 06416 USA ~ Phone: 800-528-8665 ~ Int’l: (01) 860-635-2200
Fax: (01) 860-635-3631 ~ E-mail: info@ripley-tools.com ~ Internet: www.ripley-tools.com
16723 rev2
05-08-17 ff
BLADE REPLACEMENT INSTRUCTIONS
1. Remove both slotted screws from one of the body halves.
2. Remove blades and replace. Note: The identification mark must appear on the outer surface of the blade. Replace the slotted screws.
3. Repeat steps 1 and 2 for other body half.
REPLACEMENT BLADE INFORMATION
BLADES ARE INTERCHANGEABLE WITH EITHER TOOL VERSION
Notched Plexiglas Cleaning Blades P/N 16722
Straight Edge Plexiglas Blades P/N 16725
Micarta Notched Cleaning Blades P/N 16733
WARRANTY: RIPLEY warrants its products against defective materials and workmanship for a period of one
year from date of shipment from the RIPLEY factory provided the product is utilized in accordance with
instructions and specified ratings.
46 Nooks Hill Road, Cromwell, CT 06416 USA ~ Phone: 800-528-8665 ~ Int’l: (01) 860-635-2200
Fax: (01) 860-635-3631 ~ E-mail: info@ripley-tools.com ~ Internet: www.ripley-tools.com