Rinnai Rice Cooker V53i User Manual

V53i (VB2020FFU-US)
Type of Appliance
Rinnai Model Number Operation / Exhaust System Minimum/Maximum Gas Rate (Input) Electrical
Electrical Consumption
Ignition System Hot Water Capacity Temperature (with controller)
Temperature (without controller) Installation Energy Factor Service Connections
Water Flow Control
Temperature controlled, continuous flow, gas hot water system
Certified for installation in manufactured (mobile) homes
Energy Star qualified
REU-VB2020FFU-US Forced combustion / Direct vent 15,000 - 150,000 Btu/h (Natural Gas and Propane) Appliance: AC 120 Volts - 60 Hz
Controller: DC 12 Volts Normal 55 watts
Standby 2 watts Anti-frost protection 184 watts
Direct electronic ignition
0.6 to 5.3 GPM 98° - 140° F; 98° - 160° F available with the MCC-91 controller for
hydronic applications 120° F (factory default) Indoor only Natural Gas: 0.82 Propane: 0.82 Gas supply: 3/4 inch MNPT
Cold water inlet: 3/4 inch MNPT Hot water outlet: 3/4 inch MNPT
Water flow sensor, electronic water control device and fixed by-pass
Minimum/Maximum Water Supply Pressure
FLOW TABLE
© 2011 Rinnai Corporation
6.0
5.0
4.0
3.0
2.0
1.0
Water Flow (gpm)
0.0 0 25 50 75 100 125 150
V53i SP 1/2011
20 - 150 PSI (recommended 30-80 PSI for maximum performance)
delta T - Temperature Rise (ºF)
V53i (VB2020FFU-US)
Water Temperature Control Controller
Controller Cable Safety Devices
Clearances from Combustibles (suitable for closet, attic, and crawl space installations)
Clearances from Non-combustibles
Min. / Max. Gas Supply Pressure
Manifold Gas Pressure, sea level (inches W.C.)
NOx Warranty
Simulation feed forward and feedback MC-91-1US (optional, not included)
Deluxe controller: MC-100V-1US (optional) Bathroom controller: BC-100V-1US (optional) MCC-91-1US (hydronic applications only)
Non-polarized two-core cable, minimum 22 AWG
Flame failure - Flame Rod
Boiling protection
Combustion fan rpm check
Over current - glass fuse (3 amp)
Top of heater - 6 inches
Front of heater - 6 inches
Sides of heater - 2 inches
Top of heater - 2 inches
Front of heater - 6 inches
Sides of heater - 1/2 inch
Natural Gas: min 5” W.C. max 10.5” W.C. Propane Gas: min 8” W.C. max 13.5” W.C.
Natural Gas: high fire 2.1” W.C. low fire 0.57” W.C. Propane Gas: high fire 3.4” W.C. low fire 0.98” W.C.
Meets California and Texas NOx Emission Rules Heat exchanger: 10 years* for residential applications; (10 years* if
used with the Rinnai Hydronic Furnace); all other parts 5 years*; labor 1 year; (* 3 years if used as a circulating water heater within a circulation loop, when the water heater is in series with a circulation system and all circulating water flows through the water heater)
Remaining flame (OHS)
Thermal fuse
Automatic frost protection
Back of heater - 0 inches
Bottom of heater - 12 inches
From vent pipe - 0 inches
Back of heater - 0 inches
Bottom of heater - 12 inches
From vent pipe - 0 inches
Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation.
DIMENSIONS
in (mm)
Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-364-8643 • www.rinnai.us
WEIGHT: 51 LBS (23 KG)
The wall bracket is adjustable to allow an additional 1.57 inches (40 mm).