WARNING: If the information in these instructions is not
followed exactly, a fire or explosion may result causing
property damage, personal injury or loss of life.
— Do not store or use gasoline or other flammable vapors and
liquids in the vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in
your building.
• Immediately call your gas supplier from a neighbor’s phone.
Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire
department.
— Installation and service must be performed by a qualified
installer, service agency or the gas supplier.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
This appliance may be installed as an OEM installation in a manufactured home (USA only) or
mobile home and must be installed in accordance with the manufacturer’s instructions and the
Manufactured Home construction and Safety Standard, Title 24 CFR, Part 3280, in the United
States, or the Mobile Home Standard, CAN/CSA Z240 MH Series, in Canada. This appliance
is only for use with types of gas indicated on the rating plate. A conversion kit is supplied with
the appliance.
This appliance may be installed in an aftermarket, permanently located, manufactured home
(USA only) or mobile home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance
is not convertible for use with other gases, unless a certified kit is used.
This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and
others.
DANGER
WARNING
CAUTION
Indicates an imminently hazardous situation which, if not avoided, will result in death or
serious injury.
Indicates a potentially hazardous situation which, if not avoided, could result in death or
serious injury.
Indicates a potentially hazardous situation which, if not avoided, could result in minor or
moderate injury. It may also be used to alert against unsafe practices.
Safety Behaviors and Practices
WARNING
• Keep the area around the appliance clear and free
from combustible materials, gasoline, and other
flammable vapors and liquids.
• Never store liquid propane containers indoors.
• Do not use this appliance if any part has been
under water. Immediately call a qualified service
technician to inspect the appliance and to replace
any part of the control system and any gas control
which has been under water.
• This appliance is equipped with a three-prong plug
for your protection against shock hazard and
should be plugged directly into a properly grounded
three-prong receptacle. Do not cut or remove the
ground prong from this plug.
• Any alteration to the appliance or its controls can
be dangerous.
• Do not operate appliance with the panels removed,
cracked or broken. Replacement of the panels
should be done by a licensed or qualified service
person.
CAUTION
• Do not block the warm air discharge. Do not allow
anyone to sleep directly in front of the appliance.
• Due to high temperatures, the appliance should be
located out of traffic and away from furniture and
draperies.
• Children and adults should be alerted to the
hazards of high surface temperature and should
stay away to avoid burns or clothing ignition.
• Young children should be carefully supervised
when they are in the same room as the appliance.
• Clothing or other flammable material should not be
placed on or near the appliance.
• Any safety screen or guard removed for servicing
must be replaced prior to operating the appliance.
• Do not insert items into the louvers.
• Do not spray aerosols near the appliance while it is
operating. Most aerosols contain butane gas which
is flammable.
• Do not unplug the appliance while it is operating or
while the fans are on.
• Do not use bare hands to touch the front louvers
due to high temperatures which may cause burns.
• Wear hand protection when touching the side back
covers, front louver, and rear intake for the
convection fan.
Rinnai Corporation EX17 / EX22 Manual
3
Safety Features
• Overheat: The appliance will automatically shut
down when the appliance exceeds a predetermined
temperature.
• Flame Failure: The appliance will automatically
shut down if the burner flame is extinguished.
• Power Failure: The appliance will cut off the gas if
it loses electrical power.
• Power Surge Fuse: A glass fuse on the PC board
protects against overcurrent. If the fuse blows then
all indicator lamps will be off.
• Spark Detector: The appliance automatically
shuts down if there is an abnormal spark at ignition.
• Fusible Link: In case the overheat feature
prevents the temperature from rising then the
fusible link will break shutting off the appliance.
Specifications
Appliance Specifications
)ylno ASU( emoh derutcafunam roF noitacilppAor mobile home or residential installation
convertible for use with natural gas and liquefied petroleum gases (propane /
LPG) when provision is made for the simple conversion from one gas to the
other.
For commercial setting.
For installation at altitudes up to 10,200 feet (3109 m).
General Description Forced combustion, forced convection, flued gas furnace
cinortcele nottub hsuP noitarepO
Gas Connection1/2 in NPT
Gas Control Electronic
renrub nesnuB leets sselniatS srenruB
Temperature Control Electronic thermostat
Ignition System Electronic spark ignition
Flue System The flue must be terminated to atmosphere with only flue components listed
with the appliance’s certification. Warranty will be voided if non listed
components are installed.
Rinnai is continually updating and improving products. Therefore, specifications are subject to change without
prior notice.
The efficiency rating of this appliance is a product thermal efficiency rating determined under continuous operating
conditions and was determined independently of any installed system.
4
Rinnai Corporation EX17 / EX22 Manual
Appliance Specifications
Natural Gas Propane Gas
Minimum supply gas pressure 3.5 in (89 mm) W.C. 8.0 in (203 mm) W.C.
Maximum supply gas pressure 10.5 in (267 mm) W.C. 13.0 in (330 mm) W.C.
EX17
Natural Gas Propane Gas
BTU/hour input Low 8200
High 16700
BTU/hour output Low 6560
High 13360
Low 8200
High 16700
Low 6560
High 13360
Features
• Restarts automatically when ignition or combustion
fails.
• Clean Heating Forced Flue Type
• Easy Operation One-Touch Ignition
• Sensible Temperature Control Feature
• Comfortable Room Temperature Control and
Display
• Warm Air Outlet at Floor Level (keeps your feet
warm)
• Function Lock
• Room Temperature Setting Memory
EX22
Natural Gas Propane Gas
BTU/hour input Low 8200
High 21500
BTU/hour output Low 6560
High 17200
• Clean the Air Filter - Indicator Lamp
• Energy Saving Economy Setting
• Humidifier Tray
• Air Flow Directional Louvers
• Direct Vent Easily Installed
• Proportional Heating Variable Capacity
• Hush! Quiet Operation
• Modern Design Minimizes Floor Space
Requirements
• Fault Code Message Display
Low 8200
High 20700
Low 6560
High 16560
Rinnai Corporation EX17 / EX22 Manual
5
Operating Instructions
Getting to Know your New Heating appliance
WARM AIR OUTLET
HUMIDIFIER
REMOVE BOTTOM
COVER AND PULL
OUT TO REFILL
BOTTOM COVER
HOLD BOTH SIDES
AND PULL TOWARD
YOU
DISPLAY
TEMPERATURE/
TIMERS
SETTING CONTROLS
ON/OFF SWITCH
TURNS MAIN POWER
ON/OFF
RATING PLATE
MODEL NUMBER,
SERIAL NUMBER,
GAS TYPE, ETC.
THERMISTOR
GAS CONNECTIONS
1/2" NPT
POWER CORD
PLUG 120V AC
6
AIR FILTER
EXHAUST PIPE
VENT TERMINAL
COMBUSTION/
EXHAUST
COMBUSTION AIR
INTAKE HOSE
Rinnai Corporation EX17 / EX22 Manual
Control Panel
Clock: used to set the current
time and day.
Up/Down: function
of these buttons
varies depending on
the operating mode.
(refer to the table
below for details).
MODEOPERATION
Clock Set
Timer Program
Frost Protection
To set current time
and day
Select days of
week, time and
temperature
Set Frost
Protection
temperature
LED DISPLAY
Select: When programming the
timers, this button is used to select
and confirm day, time and
temperature settings.
Programming
ClockSelect
Function Lock
Timers
Override
Override: overrides
the current timer
setting by reversing
the current operation.
Auto: toggles the heater
between AUTO(for timer
operation) and MANUAL
operation modes.
EcoFrost
Auto
Timers: used to carry
out timer programming
and confirm all
settings.
Frost: used to initiate
the Frost mode and
allows for a minimum
frost temperature to
ON/OFF
be set.
Eco: used to select the
Economy mode.
ON/OFF: this is the main on/
off switch for the heater.
Days:shows current
day of week or day(s)
being programmed.
Clock:shows current
time or pre-set program
time for timer.
am
pm
Mo Tu We Th Fr Sa Su
1 2 3 4 OFF
Periods:shows
current operating
period or period
being programed.
Function Lock:
indicates that the
function lock is on.
Temperatures:
shows pre-set and
room temperatures.
Auto/Man: indicates
Manual or Timer
operation mode.
SetRoom
Function Lock
Economy Mode
Clock:
shows when
the clock is
being set.
Economy Mode:
indicates that the
Economy Mode is on.
Sensible Temperature Control
Auto
FrostON
Man
Override On Off
Select
Clock
ProgramTimer
Temp Review Filter
Frost:indicates that the anti-frost mode is on and that
a minimum anti-frost temperature can be entered.
Override On/Off: indicates whether the
Override function is on and whether it has
turned the heater on or off(reverse function).
ON/ : indicates when the heater is
operating and whether the burner is
alight( ).
Review: indicates that
the review mode is on.
Filter:shows when the
filter needs to be cleaned.
Select Program Timer/Temp: indicates when the timers
are being programed-Start time "Select Program Timer"
or Temperature "Select Program Temp".
The sensible temperature control feature allows
comfortable heating which matches the conditions in
the room.
Rinnai Corporation EX17 / EX22 Manual
Based on the information collected by the room
temperature thermistor when the heating starts, the
heating capacity is automatically adjusted to achieve a
comfortable heating effect and to reach the
temperature setting quickly.
7
Setting the Clock
■ TO OPEN THE CONTROL PANEL
Lift lightly in the center of the lid. The control
panel lid will then drop backward to an angle.
Note: When the appliance is first
plugged in or after a power failure
longer than 24 hours the display
will show “PF”. And the appliance
will turn on due to the frost protection
function.
■ SETTING THE CURRENT TIME & DAY
(This example shows setting the clock to 8:20am on Saturday.)
DAY OF THE WEEK
Press the “Clock” button
1
once. The day of the week
Select
and is displayed.
Clock
Press either of the “▲” or “▼”
2
buttons until the correct day of
the week is displayed.
Set
Mo
Sa
Select
Clock
Select
Clock
Frost
Programming
ClockSelect
Programming
ClockSelect
Timers
Timers
3
4
5
Press the “Select” button once
to lock in and complete day of
the week selection. The time of
day will then flash.
am
Sa
Select
Clock
TIME OF DAY
To set the time press the “▲”
or “▼” buttons until the correct
time of day is displayed.
am
Sa
Select
Clock
Pressing either button once will change the time in single minutes.
Holding button down will change the time rapidly, first in minutes, then in hours.
CONFIRM SETTINGS
Press the “Select”or “Clock”
button once to lock in and
complete setting the time.
Select
The indicators will go out.
Clock
am
Sa
Programming
ClockSelect
Programming
ClockSelect
Programming
ClockSelect
Timers
Timers
Timers
8
Rinnai Corporation EX17 / EX22 Manual
Operating the Heater Manually
■ To turn the heater ON:
1
Press the “ON/OFF” button.
ON/OFF
2
3
Check to see if the “Man” or “Auto”
indicator is displayed:
indicator
If the “Auto” indicator is displayed
then press the “Auto” button. The
indicator will change to “Man”.
Go to Step 3.
If the “Man” indicator is displayed
go to Step 3.
Select the desired room temperature
by pressing the “▲” or “▼” buttons.
pm
Tu
1
pm
Tu
pm
Tu
Set Room
Set Room
Set Room
AutoON
indicator
Man
Man
EcoFrost
Override
ON
ON
AutoON/OFF
Programming
ClockSelect
The heater will start and run for 90 seconds so that it can check the room temperature
(the indicator will show).
If the room temperature is lower than the pre-set or desired temperature the heater will continue to run.
If the room temperature is higher than the pre-set or desired temperature, the heater will go into “stand-
by” mode, and will start when the room temperature falls below the pre-set temperature.
Timers
If the heater does not ignite on initial use, this may be due to air remaining in the gas supply line. The
spark generator will only continue for 15 seconds. After this it will be necessary to press the ON/OFF
button OFF, then ON again.
■ To turn the heater OFF:
1
Press the “ON/OFF” button.
pm
Tu
Override
DO NOT turn heater off by unplugging the power cord.
The convection fan will continue to run until the appliance cools.
Rinnai Corporation EX17 / EX22 Manual
EcoFrost
AutoON/OFF
9
Programmable Weekly Timer
• The four timer periods create up to four separate operating intervals, each with its own temperature setting.
• These periods can be programmed differently for each day of the week, or for a group of days: weekdays,
weekends, or the entire week.
• The programming covers a 24 hour time span (one day).
The two diagrams below graphically represent examples of weekday and weekend programs.
5:30am
Weekday Program
• Period 1 has been programmed to start at 5:30 am
with a temperature setting of 76° F. The appliance
will heat the room at 76° F until 8:00 am, when
period 2 starts.
• Period 2 has a temperature setting of “nothing” or
OFF, and so the heater will not operate again until
the start of period 3 at 5:00 pm.
• Period 3 heats the room from 5:00 pm to 9:30 pm
at 72° F.
• Period 4 turns the appliance OFF until Period 1
begins the next day.
MIDNIGHT
9:30pm
OFF
4
1
72°F
76°F
OFF
2
8:00am
MIDDAY
Weekend Program
• Period 1 has been programmed to start at 9:00 am
with a temperature setting of 76° F. The appliance
will heat the room at 76° F until 11:00 am, when
period 2 starts.
• Period 2 has a temperature setting of “nothing” or
OFF, and so the heater will not operate again until
the start of period 3 at 4:00 pm.
• Period 3 heats the room from 4:00 pm to 11:00 pm
at 72° F.
• Period 4 has a temperature setting of LOW and
runs the appliance at this setting during the night.
3
5:00pm
1
9:00am
LOW
MIDNIGHTMIDDAY
76°F
OFF
11:00pm
4
72°F
3
4:00pm
11:00am
2
10
Rinnai Corporation EX17 / EX22 Manual
Programming the Weekly Timers
The following is a general outline of the setting options and procedures avaliable when
programming the weekly timers.
Note: Before programming the current time and day must be set.
The weekly timers can be easily programmed by following the steps illustrated below:
Press the “Timers”
button once to
1
activate the timer
programming mode.
Timers
2
Select the day or
group of days you
wish to program by
pressing the “up” and
“down” buttons:
Choose from the
following options:
Mo Tu We Th Fr Sa Su
Mo Tu We Th Fr
Sa Su
or each day of the
week in turn.
If a group of days is
chosen, the times and
temperatures selected
in steps 3 → 5 will
automatically apply
for those days.
Press the “Select”
button to confirm your
choice.
Select
3
Select the period you wish
to program by pressing
the “up” and “down”
buttons:
Periods 1 → 4 will
automatically appear in
order as you follow this
programing sequence, so
you may not need to
manually select a timer
period.
Press the “Select” button
to confirm your choice.
Select
am
Mo Tu We Th Fr Sa Su
1 2 3 4 OFF
4
Set the start time for this
period by pressing the
“up” and “down ”buttons:
The time will move up or
down in 10 minute
increments.
Each period must be set
to a later time than the
period before it.
No period can be set
past 11:50 pm, as this is
the end of the 24 hour
program.
Press the “Select”button
to confirm the time.
Select
Set
AutoManSelectClock
Frost
Override
Prog
TempR
5
Set the temperature
you want for this period
by pressing the “up”
and “down” buttons:
Choose from the
following temperature
settings:
H(high, maximum fire)
80° F →60° F
L(low, minimum fire)
- - (OFF)
If you want heat during
this period, choose a
temperature.
If you do not want heat,
choose the OFF setting.
Press the “Select” button
to confirm the
temperature setting.
Select
Repeat steps→for periods 1 through to 4 until you are satisfied with all the settings.
6
Press the “Timers“ button again to confirm your program and lock in all settings.
7
3
5
Rinnai Corporation EX17 / EX22 Manual
11
Programming the Weekly Timers (Example)
Note: Before programing the timers, the clock must be set to the correct time.
The following is a step by step guide to programing the timers by an example schedule.
If programing is paused for longer than 2 minutes the display will return to the current time,
and all programing up to that stage will be lost.
The times and temperatures in the EXAMPLE box below can be used for learning how to set the programm-
able thermostat.
■ EXAMPLELet's use the following schedule to program the weekdays...
EXAMPLE SCHEDULE
Time SettingTemperature
1
Periods
2
3
4
5:30 am
8:00 am
5:00 pm
9:30 pm
76°F
OFF
72°F
OFF
Press the “Timers” button once. The
1
display will show “Select Program
Timer” and the “Mo Tu We Th Fr Sa Su”
indicators will flash.
Press the “▲” button once, the “Mo Tu
2
We Th Fr” indicators will flash.
Press the “Select” button once, the period □
3
indicator will flash and the time and
temperature display will be shown.
Press the “Select” button again. The
4
period □1indicator will become stable,
the temperature display will go out and
the clock will flash.
Press the “▼” button until the display
5
shows “am5:30”(as shown in the
example schedule for period □1).
Programming
Tu WeTh Fr SuMoSa
Tu WeTh FrMo
1
am
Tu WeTh FrMo
1
am
Tu WeTh FrMo
1
am
Tu WeTh FrMo
1
Set
Select
Select
Select
Select
Select
Program Timer
Program Timer
Program Timer
Program Timer
Program Timer
ClockSelect
Programming
ClockSelect
Programming
ClockSelect
Programming
ClockSelect
Programming
ClockSelect
Timers
Timers
Timers
Timers
Timers
Press the “Select” button again. The clock
6
indicator will become stable, the pre-set
temperature will flash and “Select Program
Temp” will be shown.
12
am
Tu WeTh FrMo
1
Set
Select
Temp
Rinnai Corporation EX17 / EX22 Manual
Program
Programming
ClockSelect
Timers
Programming the Weekly Timers (Example)
Press the “▲” button to set the pre-set
7
temperature to 76°F(remember, we are
using the example schedule).
Press the “Select” button again. Now the
8
period □2indicator will flash and the time
and temperature display will be shown.
Press the “Select” button again. The
9
period □2indicator will become stable,
the temperature display will go out and
the clock indicator will flash.
Press the “▼” button until the display
10
shows “am8:00”(as in the example for
period □2).
Press the “Select” button again. The clock
11
indicator will become stable, the pre-set
temperature will flash and “Select Program
Temp” will be shown.
am
Tu WeTh FrMo
1
am
Tu WeTh FrMo
2
am
Tu WeTh FrMo
2
am
Tu WeTh FrMo
2
am
Tu WeTh FrMo
2
Set
Select
Program
Temp
Set
Select
Program Timer
Select
Program Timer
Select
Program Timer
Set
Select
Program
Temp
Programming
ClockSelect
Programming
ClockSelect
Programming
ClockSelect
Programming
ClockSelect
Programming
ClockSelect
Timers
Timers
Timers
Timers
Timers
Press the “▼” button until the
12
temperature shows “- -” and the “OFF”
indicator is displayed.
13
Set periods □3and □4following/repeating steps to , and then go to step .
Press the “Select” button again. The
14
period 1 indicator will flash and “Sa Su”
will be displayed.
15
You can now program a Weekend schedule by repeating steps to , and then go to step .
Once all timers are programed, Press the
16
“Timers” button once to save all timer
settings. The display will return to the
am
Tu WeTh FrMo
2OFF
73
am
1
pm
Mo
Set
Select
Program
Temp
14
Set
SuSa
Select
Program Timer
73
current time and the “Set Program Timer”
indicator will go out.
To review all of the programed settings go to “WEEKLY TIMER REVIEW FUNCTION”.
For a description of how to operate the heater with these programed settings, go to “OPERATING THE
TIMERS”.
Programming
ClockSelect
Programming
ClockSelect
16
Programming
ClockSelect
Timers
Timers
Timers
Rinnai Corporation EX17 / EX22 Manual
13
Weekly Timer Review Function
This function lets you review all of the programed Weekly Timer settings(times and temperatures)
without the option of adjusting these settings, removing the danger of accidently changing the
program.
This is a quick way to review the Weekly Timer program before operating the timers.
■ To enter the Weekly Timer Review mode:
NOTE: If the heater is left in “Timer Review Mode” for longer than 10 seconds without the “ ” or “ ” buttons being
▲▼
pressed, it will exit this mode and return the previous operation.
Press and hold.
1
Press and hold the “Timers” button
for approximately 3 seconds(an
audible “beep” will be heard).
am
Mo
1
Set
Review
Programming
ClockSelect
NOTE:
The Period □1, “Mo”, time,
temperature, and “Review”
indicators will show.
2
Press the “ ▲ ” button repeatedly
to review the Weekly Timer
program.
am
Tu
1
Set
Review
Programming
ClockSelect
The four timer periods for each
day of the week will show in turn,
starting with “Mo”(Monday) then
“Tu” etc.
Timers
Timers
Press the “ ▼ ” button to go
backwards through the program.
■ To exit the Weekly Timer Review mode:
1
14
Press the “Timers” button.
Rinnai Corporation EX17 / EX22 Manual
Programming
pm
Tu
ClockSelect
Timers
Your Weekly Timer Program
■ Points to consider before writing your program:
When do I want the heater to operate, and what temperature do I want?
When do I not want the heater to operate?
Will I use the same settings for everyday of the week, or do I need a separate program for the weekdays,
and the weekend? Do I need a separate setting for each day of the week?
■ Points to remember when writing your program:
The four periods are set within a 24 hour time span.
The start of a new period marks the end of the previous one, so each period only requires a START time.
Period 4 ends with the start of period 1 on the next day.
Each period must be set to a later time than the one before it.
If you want to heat during the period, select a temperature: H(high), 80 → 60, L(low).
If you do not want to heat during this period, select the OFF setting.
■ Write your own program:
Use the tables below to write your own weekly timer program, then program the timers.
Start TimeTemperature or OFF
1
2
3
4
1
2
3
4
Start TimeTemperature or OFF
Factory Pre-set Program
WEEK DAY
The heater comes shipped with a factory set
program(opposite).
If the heater is not set with a new program it will run
according to this program when you operate the
timers.
If the Weekly Timer program settings are erased,
the heater will revert to this program.
Start TimeTemp or OFF
1
2
3
4
WEEK END
Start Time
1
2
3
4
6:00 am
8:30 am
5:00 pm
11:30 pm
7:00 am
12:00 pm
5:00 pm
11:30 pm
72°F
64°F
74°F
64°F
Temp or OFF
72°F
70°F
74°F
64°F
Rinnai Corporation EX17 / EX22 Manual
15
Operating the Timers
■ Before operating the timers, please check the following points:
The clock must be set to the current time and day.
If no personal program is entered, the heater will operate according to the the default factory settings.
■ Follow the steps below to operate the timers:
1
2
3
Press the “ON/OFF” button. The
“Man”(Manual) and “ON” indicators
will come on as well as the preset
pm
Tu
Set Room
Man
ON
Override
EcoFrost
AutoON/OFF
and room temperatures.
Press the “Auto” button. The “Man”(Manual) indicator will be replaced by the “Auto”(Automatic) indicator,
and the current timer period will show.
4 OFF
Set Room
Set Room
AutoON
AutoON
Override
EcoFrost
AutoON/OFF
If the current period has been
programed with a temperature,
the heater will start heating.
If the current period has been
programed with an OFF setting
the heater will not heat during
pm
Tu
3
pm
Tu
this period.
The heater will now operate according to the four periods programed into the Weekly Timer.
Returning to Manual Mode
1
Press the “Auto” button. The “Auto”
indicator will go out and be replaced
by the “Man”(Manual) indicator.
The heater will now heat depending
on your manual settings.
16
pm
Tu
Set Room
Man
Rinnai Corporation EX17 / EX22 Manual
ON
Override
EcoFrost
AutoON/OFF
Override Function
■ This function is used when the heater is in “Auto” mode(timer operation).
■ It allows you to “Override” the preset timer setting until the beginning of the next period.
For example, if the heater is ON, pressing the “Override” button will turn it OFF until the next priod. If the
heater is OFF, pressing the “Override” button will turn the heater ON, and allow you to select a
temperature, until the next period.
■ To turn on the Override function:
Remember: The Override function is for use in the “Auto”(timer) mode only.
1
2
Press the “Override” button.
Override
One of the following will happen depending on the current timer period setting:
If the current timer
period is ON (heating)
The heater will turn OFF, the
temperatures will display “-”, and the
“Override” and “Off” indicators will light.
or
The heater will turn ON, the manual
pre-set temperature and room
temperature will show , and the
If the current timer
“Override” and “On” indicators will light.
pm
Tu
3
Set Room
The heater will remain OFF until
AutoON
OverrideOff
pm
Tu
3OFF
Press the “ ▲ ” or “ ▼ ” buttons to manually
adjust the pre-set room temperature.
a. the next timer period, or
b. the Override function turned off
manually(see step below).
period is OFF
Set Room
AutoON
Override On
■ To turn off the Override function:
1
Press the “Override” button.
Then the heater will return to the operation of the current timer period.
Rinnai Corporation EX17 / EX22 Manual
The heater will remain heating until
a. the next timer period, or
b. the Override function turned off
manually (see step below).
17
Loading...
+ 39 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.