Rinnai Rice Cooker EX17 (RHFE-433RWTA) Installation Manual

Owner’s Operation and Installation Manual for the
EX17 (RHFE-433RWTA) EX22 (RHFE-558RWTA)
Energysaver ®
Gas Direct Vent Wall Furnace
Table of Contents ........... 2
Safety Information .......... 3
Operating Instructions .... 6
Care and Maintenance ... 22
Fault Codes .................... 24
Installation Instructions...26
Parts List ........................45
Consumer Support ......... 54
WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
— Do not store or use gasoline or other flammable vapors and
liquids in the vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in
your building.
Immediately call your gas supplier from a neighbor’s phone.
Follow the gas supplier’s instructions.
department.
— Installation and service must be performed by a qualified
installer, service agency or the gas supplier.
INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.
This appliance may be installed as an OEM installation in a manufactured home (USA only) or mobile home and must be installed in accordance with the manufacturer’s instructions and the Manufactured Home construction and Safety Standard, Title 24 CFR, Part 3280, in the United States, or the Mobile Home Standard, CAN/CSA Z240 MH Series, in Canada. This appliance is only for use with types of gas indicated on the rating plate. A conversion kit is supplied with the appliance.
This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.
Table of Contents
Consumer Safety Information
Safety Definitions ............................................. 3
Safety Behaviors and Practices ....................... 3
Safety Features ................................................ 4
Specifications
Appliance Specifications .............................. 4, 5
Features ........................................................... 5
Operating Instructions
Getting to Know your New Heating Appliance 6
Control Panel ................................................... 7
LED Display ..................................................... 7
Setting the Clock .............................................. 8
Operating the Heater Manually ........................ 9
Programmable Weekly Timer ........................ 10
Programming the Weekly Timers................... 11
Programming the Weekly Timers (Example) .....
................................................................. 12, 13
Weekly Timer Review Function ..................... 14
Your Weekly Timer Program.......................... 15
Factory Pre-set Program................................ 15
Operating the Timers ..................................... 16
Returning to Manual Mode ............................ 16
Override Function .......................................... 17
Frost Protection .............................................. 18
Energy Saving Mode ...................................... 19
Function Lock ................................................. 20
Humidifier and Air Flow Direction .................. 21
Care and Maintenance ................................... 22
Before Making a Service Call ......................... 23
Fault Codes .................................................... 24
Restart Function ............................................. 25
Troubleshooting ............................................. 25
Installation Instructions
General Instructions ....................................... 26
Gas Connection ............................................. 27
Clearances to Combustibles .......................... 27
Attach Back Covers (Sides only) .................. 27
Flue Terminal Clearances ....................... 28, 29
Dimensions .................................................... 30
Installation Parts ........................................... 31
Drilling Flue Hole ........................................... 32
Flue Manifold Installation ......................... 33, 34
Extension Kit Installation .......................... 35-38
Connecting the Appliance .............................. 39
Operating Instructions ................................... 40
Cut-Away Diagram .........................................
Wiring Diagram .............................................. 42
Ladder Diagram ............................................. 43
Flow Diagram ................................................. 44
Parts List ................................................... 45-53
Consumer Support
Warranty Information ..................................... 54
Limited Warranty ...................................... 54, 55
41
2
Rinnai Corporation EX17 / EX22 Manual
Consumer Safety Information
Safety Definitions
This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and
others.
DANGER
WARNING
CAUTION
Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.
Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.
Indicates a potentially hazardous situation which, if not avoided, could result in minor or moderate injury. It may also be used to alert against unsafe practices.
Safety Behaviors and Practices
WARNING
Keep the area around the appliance clear and free from combustible materials, gasoline, and other flammable vapors and liquids.
Never store liquid propane containers indoors.
Do not use this appliance if any part has been
under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.
This appliance is equipped with a three-prong plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the ground prong from this plug.
Any alteration to the appliance or its controls can be dangerous.
Do not operate appliance with the panels removed, cracked or broken. Replacement of the panels should be done by a licensed or qualified service person.
CAUTION
Do not block the warm air discharge. Do not allow anyone to sleep directly in front of the appliance.
Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies.
Children and adults should be alerted to the hazards of high surface temperature and should stay away to avoid burns or clothing ignition.
Young children should be carefully supervised when they are in the same room as the appliance.
Clothing or other flammable material should not be placed on or near the appliance.
Any safety screen or guard removed for servicing must be replaced prior to operating the appliance.
Do not insert items into the louvers.
Do not spray aerosols near the appliance while it is
operating. Most aerosols contain butane gas which is flammable.
Do not unplug the appliance while it is operating or while the fans are on.
Do not use bare hands to touch the front louvers due to high temperatures which may cause burns.
Wear hand protection when touching the side back covers, front louver, and rear intake for the convection fan.
Rinnai Corporation EX17 / EX22 Manual
3
Safety Features
Overheat: The appliance will automatically shut down when the appliance exceeds a predetermined temperature.
Flame Failure: The appliance will automatically shut down if the burner flame is extinguished.
Power Failure: The appliance will cut off the gas if it loses electrical power.
Power Surge Fuse: A glass fuse on the PC board protects against overcurrent. If the fuse blows then all indicator lamps will be off.
Spark Detector: The appliance automatically shuts down if there is an abnormal spark at ignition.
Fusible Link: In case the overheat feature prevents the temperature from rising then the fusible link will break shutting off the appliance.
Specifications
Appliance Specifications
)ylno ASU( emoh derutcafunam roF noitacilppA or mobile home or residential installation convertible for use with natural gas and liquefied petroleum gases (propane / LPG) when provision is made for the simple conversion from one gas to the other. For commercial setting. For installation at altitudes up to 10,200 feet (3109 m).
General Description Forced combustion, forced convection, flued gas furnace
cinortcele nottub hsuP noitarepO
Gas Connection 1/2 in NPT
Gas Control Electronic
renrub nesnuB leets sselniatS srenruB
Temperature Control Electronic thermostat
Ignition System Electronic spark ignition
Flue System The flue must be terminated to atmosphere with only flue components listed
with the appliance’s certification. Warranty will be voided if non listed components are installed.
Humidifier Tray Capacity - 3 pints (1300 cc)
Electrical Connection AC 120V, 60 Hz, 46 watts (EX17), 51 watts (EX22)
Weight 53 lbs (24 kg)
Noise Level EX17: 33-39 dB , EX22: 33-43 dB
AFUE Rating EX17: Natural Gas: 81.0% Propane: 81.0%
EX22: Natural Gas: 80.0% Propane: 81.0%
Rinnai is continually updating and improving products. Therefore, specifications are subject to change without prior notice.
The efficiency rating of this appliance is a product thermal efficiency rating determined under continuous operating conditions and was determined independently of any installed system.
4
Rinnai Corporation EX17 / EX22 Manual
Appliance Specifications
Natural Gas Propane Gas
Minimum supply gas pressure 3.5 in (89 mm) W.C. 8.0 in (203 mm) W.C.
Maximum supply gas pressure 10.5 in (267 mm) W.C. 13.0 in (330 mm) W.C.
EX17
Natural Gas Propane Gas
BTU/hour input Low 8200
High 16700
BTU/hour output Low 6560
High 13360
Low 8200 High 16700
Low 6560 High 13360
Features
Restarts automatically when ignition or combustion fails.
Clean Heating Forced Flue Type
Easy Operation One-Touch Ignition
Sensible Temperature Control Feature
Comfortable Room Temperature Control and
Display
Warm Air Outlet at Floor Level (keeps your feet warm)
Function Lock
Room Temperature Setting Memory
EX22
Natural Gas Propane Gas
BTU/hour input Low 8200
High 21500
BTU/hour output Low 6560
High 17200
Clean the Air Filter - Indicator Lamp
Energy Saving Economy Setting
Humidifier Tray
Air Flow Directional Louvers
Direct Vent Easily Installed
Proportional Heating Variable Capacity
Hush! Quiet Operation
Modern Design Minimizes Floor Space
Requirements
Fault Code Message Display
Low 8200 High 20700
Low 6560 High 16560
Rinnai Corporation EX17 / EX22 Manual
5
Operating Instructions
Getting to Know your New Heating appliance
WARM AIR OUTLET
HUMIDIFIER REMOVE BOTTOM COVER AND PULL OUT TO REFILL
BOTTOM COVER HOLD BOTH SIDES AND PULL TOWARD YOU
DISPLAY TEMPERATURE/ TIMERS SETTING CONTROLS
ON/OFF SWITCH TURNS MAIN POWER ON/OFF
RATING PLATE MODEL NUMBER, SERIAL NUMBER, GAS TYPE, ETC.
THERMISTOR
GAS CONNECTIONS 1/2" NPT
POWER CORD
PLUG 120V AC
6
AIR FILTER
EXHAUST PIPE
VENT TERMINAL COMBUSTION/ EXHAUST
COMBUSTION AIR INTAKE HOSE
Rinnai Corporation EX17 / EX22 Manual
Control Panel
Clock: used to set the current time and day.
Up/Down: function of these buttons varies depending on the operating mode. (refer to the table below for details).
MODE OPERATION
Clock Set
Timer Program
Frost Protection
To set current time
and day
Select days of
week, time and
temperature
Set Frost
Protection
temperature
LED DISPLAY
Select: When programming the timers, this button is used to select and confirm day, time and temperature settings.
Programming
Clock Select
Function Lock
Timers
Override
Override: overrides the current timer setting by reversing the current operation.
Auto: toggles the heater between AUTO(for timer operation) and MANUAL
operation modes.
EcoFrost
Auto
Timers: used to carry out timer programming and confirm all settings.
Frost: used to initiate the Frost mode and allows for a minimum frost temperature to
ON/OFF
be set.
Eco: used to select the Economy mode.
ON/OFF: this is the main on/ off switch for the heater.
Days:shows current day of week or day(s) being programmed.
Clock:shows current time or pre-set program time for timer.
am pm
Mo Tu We Th Fr Sa Su
1 2 3 4 OFF
Periods:shows current operating period or period being programed.
Function Lock: indicates that the function lock is on.
Temperatures: shows pre-set and room temperatures.
Auto/Man: indicates Manual or Timer operation mode.
Set Room
Function Lock Economy Mode
Clock: shows when the clock is being set.
Economy Mode: indicates that the Economy Mode is on.
Sensible Temperature Control
Auto
Frost ON
Man
Override On Off Select Clock
Program Timer
Temp Review Filter
Frost:indicates that the anti-frost mode is on and that a minimum anti-frost temperature can be entered.
Override On/Off: indicates whether the Override function is on and whether it has turned the heater on or off(reverse function).
ON/  : indicates when the heater is operating and whether the burner is alight().
Review: indicates that the review mode is on.
Filter:shows when the filter needs to be cleaned.
Select Program Timer/Temp: indicates when the timers are being programed-Start time "Select Program Timer" or Temperature "Select Program Temp".
The sensible temperature control feature allows comfortable heating which matches the conditions in the room.
Rinnai Corporation EX17 / EX22 Manual
Based on the information collected by the room temperature thermistor when the heating starts, the heating capacity is automatically adjusted to achieve a comfortable heating effect and to reach the temperature setting quickly.
7
Setting the Clock
TO OPEN THE CONTROL PANEL
Lift lightly in the center of the lid. The control panel lid will then drop backward to an angle.
Note: When the appliance is first plugged in or after a power failure longer than 24 hours the display will show “PF”. And the appliance will turn on due to the frost protection function.
SETTING THE CURRENT TIME & DAY
(This example shows setting the clock to 8:20am on Saturday.)
DAY OF THE WEEK
Press the “Clock” button
1
once. The day of the week
Select
and is displayed.
Clock
Press either of the “” or “
2
buttons until the correct day of the week is displayed.
Set
Mo
Sa
Select Clock
Select Clock
Frost
Programming
Clock Select
Programming
Clock Select
Timers
Timers
3
4
5
Press the “Select” button once to lock in and complete day of the week selection. The time of day will then flash.
am
Sa
Select Clock
TIME OF DAY
To set the time press the “” or “” buttons until the correct time of day is displayed.
am
Sa
Select Clock
Pressing either button once will change the time in single minutes.
Holding button down will change the time rapidly, first in minutes, then in hours.
CONFIRM SETTINGS
Press the “Select”or “Clock” button once to lock in and complete setting the time.
Select
The indicators will go out.
Clock
am
Sa
Programming
Clock Select
Programming
Clock Select
Programming
Clock Select
Timers
Timers
Timers
8
Rinnai Corporation EX17 / EX22 Manual
Operating the Heater Manually
To turn the heater ON:
1
Press the “ON/OFF” button.
ON/OFF
2
3
Check to see if the “Man” or “Auto” indicator is displayed:
indicator
If the “Auto” indicator is displayed then press the “Auto” button. The indicator will change to “Man”. Go to Step 3.
If the “Man” indicator is displayed go to Step 3.
Select the desired room temperature by pressing the “” or “” buttons.
pm
Tu
1
pm
Tu
pm
Tu
Set Room
Set Room
Set Room
Auto ON
indicator
Man
Man
EcoFrost
Override
ON
ON
Auto ON/OFF
Programming
Clock Select
The heater will start and run for 90 seconds so that it can check the room temperature
(the indicator will show).
If the room temperature is lower than the pre-set or desired temperature the heater will continue to run.
If the room temperature is higher than the pre-set or desired temperature, the heater will go into “stand-
by” mode, and will start when the room temperature falls below the pre-set temperature.
Timers
If the heater does not ignite on initial use, this may be due to air remaining in the gas supply line. The spark generator will only continue for 15 seconds. After this it will be necessary to press the ON/OFF button OFF, then ON again.
To turn the heater OFF:
1
Press the “ON/OFF” button.
pm
Tu
Override
DO NOT turn heater off by unplugging the power cord.
The convection fan will continue to run until the appliance cools.
Rinnai Corporation EX17 / EX22 Manual
EcoFrost
Auto ON/OFF
9
Programmable Weekly Timer
The four timer periods create up to four separate operating intervals, each with its own temperature setting.
These periods can be programmed differently for each day of the week, or for a group of days: weekdays,
weekends, or the entire week.
The programming covers a 24 hour time span (one day).
The two diagrams below graphically represent examples of weekday and weekend programs.
5:30am
Weekday Program
Period 1 has been programmed to start at 5:30 am with a temperature setting of 76° F. The appliance will heat the room at 76° F until 8:00 am, when period 2 starts.
Period 2 has a temperature setting of “nothing” or OFF, and so the heater will not operate again until the start of period 3 at 5:00 pm.
Period 3 heats the room from 5:00 pm to 9:30 pm at 72° F.
Period 4 turns the appliance OFF until Period 1 begins the next day.
MIDNIGHT
9:30pm
OFF
4
1
72°F
76°F
OFF
2
8:00am
MIDDAY
Weekend Program
Period 1 has been programmed to start at 9:00 am with a temperature setting of 76° F. The appliance will heat the room at 76° F until 11:00 am, when period 2 starts.
Period 2 has a temperature setting of “nothing” or OFF, and so the heater will not operate again until the start of period 3 at 4:00 pm.
Period 3 heats the room from 4:00 pm to 11:00 pm at 72° F.
Period 4 has a temperature setting of LOW and runs the appliance at this setting during the night.
3
5:00pm
1
9:00am
LOW
MIDNIGHT MIDDAY
76°F
OFF
11:00pm
4
72°F
3
4:00pm
11:00am
2
10
Rinnai Corporation EX17 / EX22 Manual
Programming the Weekly Timers
The following is a general outline of the setting options and procedures avaliable when programming the weekly timers.
Note: Before programming the current time and day must be set.
The weekly timers can be easily programmed by following the steps illustrated below:
Press the “Timers” button once to
1
activate the timer programming mode.
Timers
2
Select the day or group of days you
wish to program by pressing the “up” and “down” buttons:
Choose from the following options: Mo Tu We Th Fr Sa Su
Mo Tu We Th Fr Sa Su
or each day of the week in turn.
If a group of days is chosen, the times and temperatures selected in steps 3 → 5 will automatically apply for those days.
Press the “Select” button to confirm your choice.
Select
3
Select the period you wish to program by pressing the “up” and “down” buttons:
Periods 1 → 4 will automatically appear in order as you follow this programing sequence, so you may not need to manually select a timer period.
Press the “Select” button to confirm your choice.
Select
am
Mo Tu We Th Fr Sa Su
1 2 3 4 OFF
4
Set the start time for this period by pressing the “up” and “down ”buttons:
The time will move up or down in 10 minute increments.
Each period must be set to a later time than the period before it.
No period can be set past 11:50 pm, as this is the end of the 24 hour program.
Press the “Select”button to confirm the time.
Select
Set
Auto Man Select Clock
Frost
Override
Prog
Temp R
5
Set the temperature you want for this period by pressing the “up” and “down” buttons:
Choose from the following temperature settings:
H(high, maximum fire)
80° F →60° F
L(low, minimum fire)
- - (OFF)
If you want heat during this period, choose a temperature.
If you do not want heat, choose the OFF setting.
Press the “Select” button to confirm the temperature setting.
Select
Repeat steps for periods 1 through to 4 until you are satisfied with all the settings.
6
Press the “Timers“ button again to confirm your program and lock in all settings.
7
3
5
Rinnai Corporation EX17 / EX22 Manual
11
Programming the Weekly Timers (Example)
Note: Before programing the timers, the clock must be set to the correct time.
The following is a step by step guide to programing the timers by an example schedule. If programing is paused for longer than 2 minutes the display will return to the current time,
and all programing up to that stage will be lost.
The times and temperatures in the EXAMPLE box below can be used for learning how to set the programm-
able thermostat.
EXAMPLE Let's use the following schedule to program the weekdays...
EXAMPLE SCHEDULE
Time Setting Temperature
1
Periods
2 3 4
5:30 am 8:00 am 5:00 pm
9:30 pm
76°F OFF 72°F
OFF
Press the “Timers” button once. The
1
display will show “Select Program Timer” and the “Mo Tu We Th Fr Sa Su” indicators will flash.
Press the “” button once, the “Mo Tu
2
We Th Fr” indicators will flash.
Press the “Select” button once, the period
3
indicator will flash and the time and temperature display will be shown.
Press the “Select” button again. The
4
period 1indicator will become stable, the temperature display will go out and the clock will flash.
Press the “” button until the display
5
shows “am5:30”(as shown in the example schedule for period 1).
Programming
Tu WeTh Fr SuMo Sa
Tu WeTh FrMo
1
am
Tu WeTh FrMo
1
am
Tu WeTh FrMo
1
am
Tu WeTh FrMo
1
Set
Select
Select
Select
Select
Select
Program Timer
Program Timer
Program Timer
Program Timer
Program Timer
Clock Select
Programming
Clock Select
Programming
Clock Select
Programming
Clock Select
Programming
Clock Select
Timers
Timers
Timers
Timers
Timers
Press the “Select” button again. The clock
6
indicator will become stable, the pre-set temperature will flash and “Select Program Temp” will be shown.
12
am
Tu WeTh FrMo
1
Set
Select
Temp
Rinnai Corporation EX17 / EX22 Manual
Program
Programming
Clock Select
Timers
Programming the Weekly Timers (Example)
Press the “” button to set the pre-set
7
temperature to 76°F(remember, we are using the example schedule).
Press the “Select” button again. Now the
8
period 2indicator will flash and the time and temperature display will be shown.
Press the “Select” button again. The
9
period 2indicator will become stable, the temperature display will go out and the clock indicator will flash.
Press the “” button until the display
10
shows “am8:00”(as in the example for period 2).
Press the “Select” button again. The clock
11
indicator will become stable, the pre-set temperature will flash and “Select Program Temp” will be shown.
am
Tu WeTh FrMo
1
am
Tu WeTh FrMo
2
am
Tu WeTh FrMo
2
am
Tu WeTh FrMo
2
am
Tu WeTh FrMo
2
Set
Select
Program
Temp
Set
Select
Program Timer
Select
Program Timer
Select
Program Timer
Set
Select
Program
Temp
Programming
Clock Select
Programming
Clock Select
Programming
Clock Select
Programming
Clock Select
Programming
Clock Select
Timers
Timers
Timers
Timers
Timers
Press the “” button until the
12
temperature shows “- -” and the “OFF” indicator is displayed.
13
Set periods 3and 4following/repeating steps to , and then go to step .
Press the “Select” button again. The
14
period 1 indicator will flash and “Sa Su” will be displayed.
15
You can now program a Weekend schedule by repeating steps to , and then go to step .
Once all timers are programed, Press the
16
“Timers” button once to save all timer settings. The display will return to the
am
Tu WeTh FrMo
2 OFF
73
am
1
pm
Mo
Set
Select
Program
Temp
14
Set
SuSa
Select
Program Timer
73
current time and the “Set Program Timer” indicator will go out.
To review all of the programed settings go to “WEEKLY TIMER REVIEW FUNCTION”. For a description of how to operate the heater with these programed settings, go to “OPERATING THE
TIMERS”.
Programming
Clock Select
Programming
Clock Select
16
Programming
Clock Select
Timers
Timers
Timers
Rinnai Corporation EX17 / EX22 Manual
13
Weekly Timer Review Function
This function lets you review all of the programed Weekly Timer settings(times and temperatures)
without the option of adjusting these settings, removing the danger of accidently changing the
program.
This is a quick way to review the Weekly Timer program before operating the timers.
To enter the Weekly Timer Review mode:
NOTE: If the heater is left in “Timer Review Mode” for longer than 10 seconds without the “   ” or “   ” buttons being
pressed, it will exit this mode and return the previous operation.
Press and hold.
1
Press and hold the “Timers” button
for approximately 3 seconds(an audible “beep” will be heard).
am
Mo
1
Set
Review
Programming
Clock Select
NOTE:
The Period 1, “Mo”, time,
temperature, and “Review” indicators will show.
2
Press the “ ” button repeatedly
to review the Weekly Timer program.
am
Tu
1
Set
Review
Programming
Clock Select
The four timer periods for each
day of the week will show in turn, starting with “Mo”(Monday) then “Tu” etc.
Timers
Timers
Press the “ ” button to go
backwards through the program.
To exit the Weekly Timer Review mode:
1
14
Press the “Timers” button.
Rinnai Corporation EX17 / EX22 Manual
Programming
pm
Tu
Clock Select
Timers
Your Weekly Timer Program
Points to consider before writing your program:
When do I want the heater to operate, and what temperature do I want?
When do I not want the heater to operate?
Will I use the same settings for everyday of the week, or do I need a separate program for the weekdays, and the weekend? Do I need a separate setting for each day of the week?
Points to remember when writing your program:
The four periods are set within a 24 hour time span.
The start of a new period marks the end of the previous one, so each period only requires a START time.
Period 4 ends with the start of period 1 on the next day.
Each period must be set to a later time than the one before it.
If you want to heat during the period, select a temperature: H(high), 80 60, L(low).
If you do not want to heat during this period, select the OFF setting.
Write your own program:
Use the tables below to write your own weekly timer program, then program the timers.
Start Time Temperature or OFF
1
2
3
4
1
2
3
4
Start Time Temperature or OFF
Factory Pre-set Program
WEEK DAY
The heater comes shipped with a factory set program(opposite).
If the heater is not set with a new program it will run according to this program when you operate the timers.
If the Weekly Timer program settings are erased, the heater will revert to this program.
Start Time Temp or OFF
1 2 3 4
WEEK END
Start Time
1 2 3 4
6:00 am 8:30 am 5:00 pm 11:30 pm
7:00 am 12:00 pm 5:00 pm 11:30 pm
72°F 64°F 74°F 64°F
Temp or OFF
72°F 70°F 74°F 64°F
Rinnai Corporation EX17 / EX22 Manual
15
Operating the Timers
Before operating the timers, please check the following points:
The clock must be set to the current time and day.
If no personal program is entered, the heater will operate according to the the default factory settings.
Follow the steps below to operate the timers:
1
2
3
Press the “ON/OFF” button. The
“Man”(Manual) and “ON” indicators
will come on as well as the preset
pm
Tu
Set Room
Man
ON
Override
EcoFrost
Auto ON/OFF
and room temperatures.
Press the “Auto” button. The “Man”(Manual) indicator will be replaced by the “Auto”(Automatic) indicator, and the current timer period will show.
4 OFF
Set Room
Set Room
Auto ON
Auto ON
Override
EcoFrost
Auto ON/OFF
If the current period has been programed with a temperature, the heater will start heating.
If the current period has been programed with an OFF setting the heater will not heat during
pm
Tu
3
pm
Tu
this period.
The heater will now operate according to the four periods programed into the Weekly Timer.
Returning to Manual Mode
1
Press the “Auto” button. The “Auto” indicator will go out and be replaced by the “Man”(Manual) indicator. The heater will now heat depending on your manual settings.
16
pm
Tu
Set Room
Man
Rinnai Corporation EX17 / EX22 Manual
ON
Override
EcoFrost
Auto ON/OFF
Override Function
This function is used when the heater is in “Auto” mode(timer operation).
It allows you to “Override” the preset timer setting until the beginning of the next period.
For example, if the heater is ON, pressing the “Override” button will turn it OFF until the next priod. If the heater is OFF, pressing the “Override” button will turn the heater ON, and allow you to select a temperature, until the next period.
To turn on the Override function:
Remember: The Override function is for use in the “Auto”(timer) mode only.
1
2
Press the “Override” button.
Override
One of the following will happen depending on the current timer period setting:
If the current timer
period is ON (heating)
The heater will turn OFF, the
temperatures will display “-”, and the
“Override” and “Off” indicators will light.
or
The heater will turn ON, the manual pre-set temperature and room temperature will show , and the
If the current timer
“Override” and “On” indicators will light.
pm
Tu
3
Set Room
The heater will remain OFF until
Auto ON
Override Off
pm
Tu
3 OFF
Press the “ ” or “ ” buttons to manually
adjust the pre-set room temperature. a. the next timer period, or b. the Override function turned off
manually(see step below).
period is OFF
Set Room
Auto ON
Override On
To turn off the Override function:
1
Press the “Override” button.
Then the heater will return to the operation of the current timer period.
Rinnai Corporation EX17 / EX22 Manual
The heater will remain heating until
a. the next timer period, or
b. the Override function turned off
manually (see step below).
17
Loading...
+ 39 hidden pages