Type of Appliance
Rinnai Model Number Gas Rate Input (BTU/hour)
Gas Rate Output (BTU/hour)
AFUE Rating Minimum Gas Supply Pressure Maximum Gas Supply Pressure Electrical Connection Gas Connection Combustion System Ignition System Fan CFM Output: Temperature Settings
Temperature Control
Direct vent wall furnace suitable for homes, apartments, and condominiums; modular/mobile home approved; forced combustion, forced convection
RHFE-433RWTA-N (Natural gas) RHFE-433RWTA-P (Propane) Low - 8,200 Low - 8,200
High - 16,700 High - 16,700 Low - 6,560 Low - 6,560
High - 13,360 High - 13,360 % %
3.5 in (89 mm) W.C. 8 in (203 mm) W.C.
10.5 in (267 mm) W.C 13 in (330 mm) W.C. AC 120V, 60 Hz, 47 watts 1/2 inch FNPT Stainless steel inshot burners Direct spark Low: 110.5 High: 141.3 Low (LO): minimum combustion
60° - 80° F in 2° increments High (HI): maximum combustion
Electronic 7 day, 28 event programmable set back thermostat
Frost protection function allows a pre-set minimum room temperature
Temperature limiting program to comply with Inside Design
Temperature limits
Humidifier Tray Weight Clearance from Combustibles
Noise Level Warm Air Outlet
FEATURES
Linear function modulation: Negative coefficient thermistor: Variable speed inducer motor: Quiet operation:
Self diagnostic electronics:
© 2009 Rinnai Corporation
Enameled tray with capacity of 3 pints (1.3 liters) Approximately 51 lbs (23 kg) Side: 2 inches (50 mm) Top: 10 inches (250 mm)
Front: 40 inches (1 m) 32 - 41 dB(A) Bottom front louvers
provides precise gas flow detects temperature change in 1/2 of a degree monitors and controls combustion fan reduces noise through use of swept blades in convection fan; and
through the design of the combustion chamber and heat exchanger which silently expand or contract due to temperature changes
continually monitors functions; provides auto shutdown codes; indicates when air filter needs cleaning
RHFE-433RWTA SP 7/2009
EX17 (RHFE-433RWTA)
Safety Devices
Venting Maximum Vent Length Wall Thickness and
Flue Manifold Kits
(the “A” vent kit is included with the appliance)
Flame rod detects flame failure; results in auto shutdown to prevent escape of gas
Bi-metal switch, thermal fuse, and thermistor detect overheat condition; results in auto shutdown
3 amp fuse protects against power surge; results in auto shutdown
Abnormal spark at time of ignition results in auto shutdown
Combustion fan purges any gas from the combustion chamber before
ignition
Convection fan continues to run after burner shutdown to cool internal parts
Function lock prevents inadvertent operation
Appliance shuts down if room reaches 104° F (40° C)
concentric; 3 1/8 inch (80 mm) wall hole 13 feet (4 m) with a maximum of 2 bends; maximum 8 feet (2.4 m) vertically
Name Kit No. fits walls
S Vent Kit FOT-150 3 - 4 1/2 in (75 - 115 mm) A Vent Kit FOT-151 4 1/2 - 9 1/2 in (115 - 240 mm) B Vent Kit FOT-152 9 1/2 - 15 3/4 in (240 - 400mm) C Vent Kit FOT-153 15 3/4 - 23 5/ 8 in (400 - 600 mm) D Vent Kit FOT-154 23 5/8 - 31 1/ 2 in (600 - 800 mm)
Warranty
Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation.
DIMENSIONS
Labor: 2 years; Parts: 5 years; Heat Exchanger: 10 years with years 6-10 prorated