Rinnai V65e Specification

V65e (VC2025W-US)
Type of Appliance
Rinnai Model Number Minimum/Maximum Gas Rate (Input) Electrical
Electrical Consumption Ignition System Hot Water Capacity
Temperature
Temperature (without remote) Installation Energy Factor Service Connections
Water Flow Control
Temperature controlled, continuous flow, gas hot water system
Certified for installation in manufactured (mobile) homes
Forced comb ustion
Energy Star qualified
REU-VC2025W-US 10,300 - 150,000 BTU/h Appliance: AC 120 Volts - 60 Hz
Controller: DC 12 Volts Normal: 57 w Standby: 2 w Anti-frost protection: 104 w Direct electronic ignition Minimum flow rate: 0.26 GPM
Minimum activation flow rate: 0.4 GPM Maximum flow rate: 6.6 GPM
98° - 120° F (factory default) Maximum temperature is selectable at 120° F or at 140° F; 98° - 160° F available with the MCC-91-2 controller for hydronic applications
120° F (factory default) or 140° F Outdoor only Natural Gas: 0.82 Propane: 0.82 Gas supply: 3/4 inch MNPT Cold water inlet: 3/4 inch MNPT
Hot water outlet: 3/4 inch MNPT Water flow sensor, electronic water control device and fixed by-pass
Minimum/Maximum Water Supply Pressure
20 - 150 PSI (recommended 30-80 PSI for maximum performance)
Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation.
FLOW TABLE
7.0
6.0
5.0
4.0
3.0
2.0
1.0
Water Flow (gpm)
0.0 0 255075100125150
delta T - Temperature Rise (ºF)
© 2012 Rinnai
V65e SP 3/2012
V65e (VC2025W-US)
Water Temperature Control Controller
Controller Cable Safety Devices
Clearances from Combustibles
Clearances from Non-combustibles
* 24 inches required for serviceability
Min. / Max. Gas Supply Pressure
Manifold Gas Pressure (inches W.C.) (sea level)
NOx
Simulation feed forward and feedback MC-91-2US (included)
Deluxe controller: MC-100V-1US (optional) Bathroom controller: BC-100V-1US (optional) MCC-91-2US (optional; for hyrdonic applications)
Non-polarized two-core cable, minimum 22 AWG
Flame failure - Flame Rod
Boiling protection
Combustion fan rpm check
Over current - glass fuse
Top of heater - 12 inches
Front (Panel) - 24 inches
Front (Exhaust) - 24 inches
Top of heater - 2 inches
Front (Panel) - 0 inches *
Front (Exhaust) - 24 inches
Remaining flame (OHS)
Thermal fuse
Automatic frost protection
Back of heater - 0 inches
Ground / bottom - 12 inches
Sides of heater - 6 inches
Back of heater - 0 inches
Ground / bottom - 2 inches
Sides of heater - 1/8 inch
Natural Gas: min 5” W.C. max 10.5” W.C. Propane Gas: min 8” W.C. max 13.5” W.C.
Natural Gas: high fire 1.75” W.C. low fire 0.61” W.C. Propane Gas: high fire 2.61” W.C. low fire 0.93” W.C.
Complies with South Coast Air Quality Management District 14 ng/J or 20 ppm NOx emission levels
Warranty Heat exchanger: 10 years* for residential and hydronic applications, increased to 12 years* if installe d
with an isolation valve kit; All other parts: 5 years*; Labor: 1 year;
(* reduced to 3 years if used as a circulating water heater within a circulation loop, when the water
heater is in series with a circulation system and all circulating water flows through the water h eater)
DIMENSIONS
14.04 (356.6)
8.90 (226)
WEIGHT: 43.6 lb (19.8 kg)
0.28 (7.2)
2.23 (56.6)
1.14 (29)
22.95 (583)
9.27 (235.5)
0.59 (15)
A
B
C
DIMEN-
SION
A (GAS) 1.31 (33.2) D 4.33 (110)
A (COLD) 1.93 (49) E 2.91 (73.8)
A (HOT) 1.35 (34.4) F 1.61 (40.8)
B 3.96 (100.7) G 2.87 (73) C 1.17 (29.8)
Inches (mm)
E
D
DIMEN-
SION
F
G
Inches (mm)
Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-364-8643 • www.rinnai.us