Rinnai V2532W, V2532WD, V2532WC, V2532WCD, V2526W Operation & Installation Manual

...
Operation / Installation Manual
To Suit Models:
REU-V1616W......... R42
REU-V1616WC...... C42
REU-V2020W......... R53
REU-V2020WC......
REU-V2526W......... R70
REU-V2532W......... R85
REU-V2532WC...... C85
REU-V2532WD......
REU-V2532WCD... C85PLUS
C53
R85PLUS
(Residential and Commercial outdoor unit)
ANS Z21.10.3=CSA 4.3
WARNING: If the information in these instructions is not followed exactly, a re
or explosion may result causing property damage, personal injury or death.
– Do not store or use gasoline or other ammable vapors and liquids in the vicinity
of this or any other appliance.
– WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• If you cannot reach your gas supplier, call the re department.
– Installation and service must be performed by a qualied installer, service agency
or the gas supplier.
V2532W
V2532WD
Natural Gas
Propane
Normal
Standby
Anti-frost Protection
Natural Gas
Prop
ane
Natural Gas
Propane
Safety Devices
Maximum Water Supply Pressure
Re
mote Control Cable
Ig
nition System
Water Temperature Control
Water Supply Pressure
Electric Connections
Direct Electronic Ignition
Appliance: AC 120 Volts, 60Hz. Remote Control: DC 12 Volts (Digital)
Simulation Feedforward and Feedback.
Minimum Water Pressure: 20 PSI (Rinnai Recommends 30-80 PSI for maximum performance)
Gas Supply: 3/4" MNPT, Cold W ater Inlet: 3/4" MNPT, Hot Water Outlet: 3/4" MNPT
Efficiency Rating
Model
Minimum Gas Consumption Btu/h
Maximum Gas Consumption Btu/h
Approved Gas Type
Temperature controlled continuous flow gas hot water system.
With or without remote controls, mounted in kitchen, bathroom, ect.
Di
rect Vent - Forced Combustion
Natural Gas or Propane - Ensure unit matches gas type it's being installed on.
Connections
By-Pass Control Minimum
Gas Supply Pressure
Maximum
Gas Supply Pressure
Type of Appliance
Operation
Exhaust System
Flame Failure - Flame Rod
Boiling Protection - 210°F
Electrical Consumption
Hot water capacity, (50°F rise)
Hot water capacity, (35°F rise)
Default Temperature Setting (no controller)
Controller Default Temperature Setting
Maximum Temperature Setting
Minimum Temperature Setting
Weight
Noi
se level
Over Current - Glass Fuse (3 amp)
Remaining Flame (OHS) 207°F Bi-Metal Switch
The
rmal Fuse 264°F
Automatic Frost Protection - Bi-Metal Sensor & Anti-Frost Heaters
Combustion Fan RPM Check - Integrated Circuit
150 PSI
Non-Polarized Two Core Cable
15,000 19,000 17,000
199,000 120,000150,000
140°F
185°F
98°F
120°F
140°F
98°F
120°F
140°F
98°F
120°F
140°F
98°F
120°F
140°F
98°F
140°F
185°F
120°F
140°F
140°F104°F 104°F 104°F 104°F140°F 140°F
185°F
120°F
46 Lbs.
84
85%
34 Lbs.
81
81%
32 Lbs.
81
81%
49 dB (A)
63 watts 52 watts 47 watts
5.5 watts
84 watts
5.5 watts
74 watts
Electronic Fixed None None Fixed
6" W.C.
10" W.C.
10.5" W.C.
13.5" W.C.
0.6 to 3.8 GPM0.6 to 4.8 GPM0.6 to 6.5 GPM
0.6 to 4.2 GPM0.6 to 5.3 GPM
0.6 to 7.0 GPM
0.6 to 8.5 GPM
V2532WC
V2532WCD
V2526W V2020W V2020WC V1616W V1616WC
S P E C I F I C A T I O N S
NOTE: Rinnai is continually updating and improving products, therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation.
Rinnai America
2
W Models
L I M I T E D W A R R A N T Y
R i n n a i W a t e r H e a t e r
WHAT IS COVERED?
This Warranty covers any defects in materials or workmanship when the product is installed and operated according to Rinnai written installation instructions, subject to the terms within this limited
warranty document. This Warranty applies only to products that are installed by a state qualied
or licensed contractor. Improper installation may void this Warranty. Rinnai strongly suggests that you use an installer who has attended a Rinnai product knowledge class before installing this water heater. This Warranty extends to the original purchaser and subsequent owners, but only while the product remains at the site of the original installation. This Warranty only extends
through the rst installation of the product and terminates if the product is moved or reinstalled at
a new location.
HOW LONG DOES COVERAGE LAST?
Warranty031705COMM-V1
Item
Commercial Residential
Heat Exchanger 5 Years* 10 Years*
All other Parts and
Components
Reasonable Labor 1 Year
Period of Coverage
5 Years* 5 Years*
*Important
Period of coverage is 3 years from date of purchase when used as a circulating water heater within a hot water circulation loop, when the water heater is in series with a circulation system
and all circulating water ows through the water heater.
WHAT WILL RINNAI DO?
Rinnai will repair or replace the product or any part or component that is defective in materials or workmanship, except as set forth below: Rinnai will pay reasonable labor and shipping costs to repair the product. All repairs must be performed using genuine Rinnai parts. All repairs or replacements must be performed by an individual or servicing company that is properly trained,
state qualied or licensed to do this type of repair.
Replacement of the product or replacement of the heat exchanger may be authorized by Rinnai only. Rinnai does not authorize any person or company to assume for it any obligation or liability in connection with the replacement of a product or heat exchanger. If Rinnai determines that repair of a product is not possible, Rinnai will replace the product with a comparable product, at Rinnai’s discretion. If a component or product returned to Rinnai is found to be free of defects in material or workmanship, or damaged by improper installation or damaged during return shipping, the warranty claim for product, parts and labor may be denied.
Rinnai America
3
W Models
L I M I T E D W A R R A N T Y
R i n n a i W a t e r H e a t e r
HOW DO I GET SERVICE?
Simply contact a Rinnai authorized Dealer or Installer for the repair of products under this Warranty. Failure to use a Rinnai authorized Dealer or Installer to provide repair service
may void the Warranty. For the name of the qualied Service Dealer or Installer nearest you,
please contact the company that installed the water heater, or;
Your local HVAC/plumbing dealer, gas service technician or place of purchase
•
Visit the Rinnai website www.rinnai.us
•
Call Rinnai at 1-800-621-9419 or write to Rinnai, 103 International Drive, Peachtree City, Georgia
•
30269
Proof of purchase is required to obtain warranty service. You can show proof of purchase with a dated sales receipt, by completing and mailing the enclosed Warranty registration card within 30 days of purchasing the product or by registering online at www.rinnai.us . Please complete the Warranty registration either online or mail it to Rinnai at the address shown on the card.
Receipt of warranty registration by Rinnai will constitute proof-of-purchase for this product. However, Warranty registration is not necessary in order to validate this Warranty.
Warranty031705COMM-V1
WHAT IS NOT COVERED?
This Warranty does not cover any failures or operating difculties due to accident, abuse, misuse,
alteration, misapplication, acts of God, improper installation, improper maintenance or service, inadequate water quality, scale buildup, freeze damage or for any other causes other than defects in materials or workmanship. This warranty does not apply to any product whose serial number or manufacture date has been defaced. This Warranty does not cover any product when used as a pool or spa heater. (See Water Quality in Care & Lime Section.)
Rinnai is not liable for any special, incidental, indirect or consequential damages that may arise, including damage to person or property, loss of use, failure to install drain pan under unit, or inconvenience. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation may not apply to you.
LIMITATION ON IMPLIED WARRANTIES
Any implied warranties of merchantability and tness arising under state law are limited in duration
to the period of coverage provided by this limited Warranty, unless the period provided by state law is less. Some states do not allow limitations on how long an implied Warranty lasts, so the above limitation may not apply to you.
This Warranty gives you specic legal rights, and you may also have other rights which vary from
state to state.
Rinnai America
4
W Models
C O N T E N T S
Specications ................................................................................ 2
Limited Warranty ........................................................................ 3,4
Owner’s Installation Information ................................................... 6
Features of Your New Water Heater ............................................ 7
Safety Issues ................................................................................ 8
Basic Operation ............................................................................ 9
About Hot Water ......................................................................... 10
Scalds-First Aid ........................................................................... 10
General Controller Information ................................................... 11
Remote Controller Operation ...................................................... 12
Deluxe Controllers .................................................. 13,14,15,16,17
Controllers Set Pattern/Temperature Tables ............................... 18
Error Messages ..................................................................... 19,20
Maintenance & Service Information ...................................... 21,22
Trouble Shooting and Common Questions ................................ 23
For Your Safety Read Before Operating .................................... 23
Operating Instructions ................................................................. 24
Care & Lime Condition Warning ................................................. 24
Installer’s Instructions ............................................................ 25-50
Rinnai America
5
W Models
O W N E R ’ S I N S T A L L A T I O N I N F O R M A T I O N
All Rinnai water heater(s) MUST be installed by a state qualied or licensed contractor. Failure to comply with state and local codes pertaining to water heater installations may void the warranty on your new water heater(s). It is the responsibility of the person having the water heater installed to ensure the installing contractor has proper licences and permits for installing water heater(s) in your location. In addition to licensing and permits, Rinnai encourages all installing contractors to attend a product knowledge class before installing any of our water heaters to help insure maximum customer satisfaction and maximum warranty coverage. Failure to comply with state and local codes may result in non-compliance and may void the warranty of the water heater(s).
This appliance must be installed in accordance with local codes, or in the ab­sence of local codes, the National Fuel Gas Code, ANSI Z223.1/NFPA 54 and/or the CSA B149.1, Natural Gas and Propane Installation Code.
Install this product outdoors ONLY, DO NOT install indoors.
Do Not use this appliance if any part has been underwater. Immediately call
a qualied service technician to inspect the appliance and to replace any
part of the control system and any gas control which has been underwater.
Detailed instructions on the proper installation practices to follow for the installation of your new hot water heater(s) are included at the back of this manual.
Rinnai America
6
W Models
F E A T U R E S O F Y O U R N E W WATER HEATER
The Rinnai Water Heater is one of the most advanced water heaters available.
?
It supplies hot water continuously at the temperature preset in the unit or at the temperature set on the optional remote controller(s). Installation of remote controller(s) are recommended for optimum performance.
The Rinnai Water Heater never runs out of hot water. While electricity, water and gas
?
supplies are connected, the Rinnai Water Heater produces hot water whenever the hot tap is open.
The gas burner lights automatically when the hot water tap is opened, and goes out
?
when the tap is closed. Ignition is electronic, there is no pilot light. When the hot water tap is off, no gas is used. You save energy and money with the Rinnai Water Heater.
The temperature of the outgoing hot water is constantly monitored by a built in sensor. If
?
the temperature of the outgoing water rises to more than 6 degrees above the selected temperature (shown on the digital remote control) the gas burner will automatically go out. The gas burner will re-ignite once the outgoing hot water temperature falls below the selected temperature.
Built into the microprocessor of the Rinnai Water Heaters is the ability to LIMIT THE
?
MAXIMUM TEMPERATURE of the hot water supplied by the Rinnai Water Heaters. Without the connection of a remote controller(s), the Rinnai Water Heater is preset to deliver water at 120OF (Residential) and 140OF (Commercial).
Residential Unit: With the remote controller(s) the water temperature is adjustable from
?
98 to 140OF. The water temperature cannot be set to a temperature other than 120OF without the use of a remote controller unit.
Commercial Unit: With the remote controller the water temperature is adjustable up to
?
Error messages are displayed on the optional remote controller(s), simplifying service
?
The Rinnai Water Heater incorporates a device to minimize temperature uctuations
?
O
F. The water temperature cannot be set to a temperature other than 140OF
185
without the use of a remote controller unit.
calls.
(cold water sandwich effect) when the water is off, then on again. This effect can be eliminated by installing the Rinnai Water Heater with a circulation loop with a small storage tank.
The sound (noise) level from the Rinnai Water Heater is very low.
?
The Rinnai Water Heater is a very compact direct vented device. It saves valuable oor
?
and wall space.
Rinnai America
7
W Models
HOTHOT
COLD
ON!ON!
100oF
140oF
S
O
L
V
E
N
T
HOTHOT
COLD
ON!ON!
98 F
o
o
110 F
HOTHOT
COLD
ON!ON!
HOT!
S A F E T Y I S S U E S
Always check water temperature by hand before entering the shower or bath. The temperature may have been changed.
The Rinnai Water Heater controls the water temperature automatically. To do this, it
sometimes needs to change the water ow accordingly. The water ow from the hot water
tap may vary after the selected temperature at the remote controller(s) is altered. The water
ow may also vary from summer to winter, as
incoming water temperatures differ.
Depending on the weather conditions and the length of the pipe between the Rinnai Water Heater and the tap in use, there may be a variation between the temperatures displayed at the remote controller(s) and the temperature of the water at the tap.
Do not clean remote controller(s) with solvents. Use a soft damp cloth.
Summer 60°F Incoming water
Winter 40°F Incoming water
The water temperature can only be adjusted between 98°F and 110°F when the hot water
tap is open, and hot water is owing.
Rinnai America
The vent/air intake should be positioned away
from ammable materials, trees, shrubs, etc.
Do Not touch the unit cover or the flue outlet. Do Not insert objects into the flue outlet. On colder days steam may discharged from
the ue outlet. This condition is normal for high efciency appliances and does not
indicate a fault.
8
W Models
HOTHOT
COLDCOLD
ON!ON!
B A S I C O P E R A T I O N
Adjusting Temperature
1
The outlet water temperature of the Rinnai Water Heater can only be adjusted by the user using the remote controller(s). To adjust the setpoint temperature of the Rinnai Water Heater, all hot water taps must be closed, and all circulating pumps turned off (where applicable). The temperature displayed on this remote controller will also be displayed on all other remote controller(s).
NOTE: TEMPERATURE CANNOT BE ADJUSTED EXCEPT BETWEEN 98°F AND 110 °F WHEN ANY HOT WATER TAP IS OPEN.
To take control of the Rinnai Water Heater
2
all hot water taps must be closed. Press the "Priority button" on the Controller you want to set the temperature with, and the green "Priority" indicator light will
3
Simply press the or button until the required temperature is
displayed on the Digital Monitor.
There is a hot water scald potential if the thermostat is set to high.
NOTE: CHECK LOCAL CODES FOR THE MAXIMUM WATER TEMPERATURE SETTING ALLOWED WHEN USED IN NURSING HOMES, SCHOOL, DAY CARE CENTERS, AND ALL OTHER PUBLIC APPLICATIONS.
4
glow. This indicates that the Rinnai Water Heater is ready to supply hot water at the set temperature as soon as a tap is opened.
Note: Rinnai water heater will not provide hot water instantly at the hot water
xtures. Any cold water existing in the hot water lines must be purged rst.
Rinnai America
CHECK WATER TEMPERATURE BEFORE ENTERING SHOWER OR BATH.
To operate the Rinnai Water Heater simply turn any hot water tap on. This will automatically light the burner providing hot water at the preset temperature. If the optional remote controller(s) have been installed, the red “IN USE” indicator will glow on all remote controller(s).
NOTE: If a newly installed unit has not been powered for at least six hours then the temperature will return to the default setting if power is interrupted.
9
W Models
A B O U T H O T W A T E R
Hot Water Is Dangerous, especially for the young and the elderly or
the inrm. The Rinnai Water Heater allows you to precisely control the
temperature of your hot water, ensuring safe hot water temperatures.
Water Temperatures over 125°F can cause severe burns instantly or death from scalds.
Hot Water can cause rst degree burns with
exposure for as little as:
3 seconds at 140 °F 20 seconds at 130 °F 8 minutes at 120 °F
Test the temperature of the water with your elbow before placing a child in the bath or shower.
Do not leave a child or an inrm person in
the bath unsupervised.
BURN
S C A L D S - F I R S T A I D
1) Remove clothing; Remove all wet clothing, quickly. Wet clothing retains the heat.
2) Apply cold water for 30 minutes; Immediately submerge the burnt area in cold water for 30 minutes to reduce the heat in the skin, preventing deeper burning. Never use butter, oils or ointment to cover the burn. They may retain the heat.
3) Keep the scalded person warm; Place a blanket around the person.
4) Seek Medical Advice; Call your medical advice hotline and describe the scald, follow their directions.
Rinnai America
10
W Models
G E N E R A L C O N T R O L L E R I NF O R M AT I O N
REMOTE CONTROLLERS IDENTIFICATION
MC-91-1US (comes with the unit)
MC-100V-1US (optional)
BC-100V-1US (optional)
The controller(s) for the Rinnai Water Heater allow the customer to control the functions of the water heater and to diagnose certain fault conditions
Rinnai America
11
W Models
REM O T E CONT R O L LER O P E R A TION
In Use Indicator
Indicates that a hot water tap is open and that control of the temperature has been taken at another controller.
Digital Monitor
ndicates the selected water
I
temperature. Error messages
ash in the event of a failure.
Thermostat
Increases or decreases the desired water temperature.
DIAGNOSTIC USE OF CONTROLLER
1. maintenance codes, press ‘On/Off’ followed by the
2.
To Display Maintenance Codes: Press ‘On/Off’ button. To sequence through stored
thermostat button.
To Display Water Flow through water heater: Press thermostat button, hold
for 2 seconds and simultaneously press ‘On/Off’ button.
3.
To display Outlet Water Temperature: Press ‘thermostat button’, hold for 2
seconds and simultaneously press ‘On/Off’ button.
Priority Indicator
Indicates whether this controller has priority control over the water temperature
Priority
Pressing takes control of the water temperature by this controller only when all taps are off.
ON/OFF
Used to switch the water heater on and off
TO CHANGE TEMPERATURES FROM OF to OC
1. Press and hold ‘On/Off’ button for 5 seconds while water heater is OFF.
O
To change back from
2.
C to OF, please repeat step 1.
MUTE To eliminate the beeping sound, press and hold
simultaneously until a ‘beep’ is heard (approximately 5 seconds).
Rinnai America
12
and button
W Models
Digital Monitor
Indicates the selected water temperature. Error messages flash in the event of a failure.
ON/OFF
Used to switch the water heater on and off.
Priority
Pressing takes control of the water temperature by this controller only when all taps are open.
Function
Enables the user to set the clock and sound volume functions.
Thermostat
Increases or decreases the desired water temperature.
In Use Indicator
Indicates that a hot water tap is open and that control of the temperature is taken at another controller.
Water Temperature Indicator
Indicates the selected hot water temperature.
Clock
12 Hour AM / PM clock. In the event of a fault, codes for error messages will flash here.
Call
Allows user to contact another controller. Can be used as a communication channel for errands or in emergency situations.
In Use Indicator
Indicates that a hot water tap is open and that control of the temperature is taken at another controller.
Priority
Pressing takes control of the water temperature by this controller only when all taps are off.
Call
Allows user to contact another controller. Can be used as a communication channel for errands or in emergency situations.
Clock
12 Hour AM / PM clock. In the event of a fault, codes for error messages will flash here.
Thermostat
Increases or decreases the desired water temperature.
Sound Volume
Used to select the voice prompt volume.
Water Smart / Bath Fill Indicator
Used to select Water Smart / Bath Fill Function.
ON/OFF
Used to switch the water heater on and off.
Water Smart / Bath Fill
Used to select Water Smart / Bath Fill Function.
Power Save
Indicates that the remote is in the energy saving mode.
Water Volume
Used to select Water Smart / Bath Fill volumes.
DELUXE CONTROLLERS
ABOUT THE DELUXE CONTROLLER (MC-100V-1US)
NOTE: With power interruption, water heater will automatically default to the ON position to provide hot water.
DELUXE BATHROOM CONTROLLERS
A B O U T TH E TH E DE LU X E BAT HR O O M CO NT R O L L ER ( B C - 1 00 V- 1U S )
Rinnai America
13
W Models
HOTHOT
COLDCOLD
ON!ON!
DELU X E CON T R O L L E R S
Setting The Sound Volume
To do this, press the ‘Function’ Button, the default voice prompt sound volume is medium, each subsequent press of the and Button will cycle through the available volume settings in
the following order: High Voice - Off Voice (beep) - Off Sound (no beep) - Low Voice - Medium Voice.
Setting The Clock (MC-100V Deluxe Controller ONLY)
The clock is a 12 hour AM/PM style display. To set the time, press the ‘Function’ Button twice within 10 seconds. Press the and Buttons to adjust the time. When you get close to
the time you wish to set, press the button intermittently to avoid going further than the desired time.
Press the ‘Function’ Button again to complete setting the clock and return to normal operation.
Adjusting Temperature
Simply press the or buttons until the required temperature is displayed on the Digital Monitor.
To Operate the hot water unit, open any hot water tap. This will automatically light the burner providing hot water. The ame of the water heater ‘In Use Indicator’ will illuminate on the Controller.
Once the hot water is running, if the set temperature is either too hot or cold, press the or
buttons until the desired temperature is reached.
NOTE: TEMPERATURE CANNOT BE ADJUSTED EXCEPT BETWEEN 98°F AND 110°F WHEN ANY HOT WATER TAP IS OPEN.
Rinnai America
14
W Models
D E LU X E B AT H R O O M CO N TR O L L E R
Setting the Sound Volume
The voice prompt sound volume for all Deluxe Controller(s) can be set individually. To do this, press the ‘Sound Vol.’ button. The default voice prompt sound volume is medium, each subsequent press of the ‘Sound Vol.’ will cycle through the available volume settings in the following order: High Voice - Off Voice (beep)
- Off Sound (no beep) - Low Voice - Medium Voice.
Adjusting Temperature
Simply press the ‘Hot water temp.’ or
buttons until the required temperature is
displayed on the Digital Monitor.
To Operate the hot water unit, open any hot water tap. This will automatically light the
burner providing hot water. The red ame of the
water heater ‘In Use Indicator’ will illuminate on the Temperature Controller.
Once the hot water is running, if the set temperature is either too hot or cold, press the
‘hot water temp. or buttons until the desired temperature is reached.
NOTE: TEMPERATURE CANNOT BE ADJUSTED EXCEPT BETWEEN 98°F AND 110°F WHEN ANY HOT WATER TAP IS OPEN.
CHECK WATER TEMPERATURE BEFORE USE. A parent should always check the temperature before a child is placed in contact with hot water.
NOTE: Avoid getting water in the speaker as this may cause damage.
Rinnai America
15
W Models
Loading...
+ 33 hidden pages