Rinnai Symmetry RDV3611 Installation Manual

Symmetry RDV3611
Installation guide
The Symmetry RDV3611 is recommended for a new build installation into a false (mock) chimney. It is not suitable for retrofitting into an existing masonry fireplace.
Appliance, including flue, is installed after framing and before cladding. Rinnai strongly recommend appliance is fully tested before any cladding material are applied.
Appliance must be:
- Installed with a Rinnai supplied flue system.
- Installed, commissioned and serviced by a licensed tradesperson in accordance with these instructions and all applicable local rules and regulations.
Warning Improper installation, adjustment, alteration, service or maintenance can cause property damage, personal injury or loss of life.
For more information about buying, living and servicing of Rinnai appliances call: 0800 RINNAI (0800 746 624)
Rinnai New Zealand Limited 105 Pavilion Drive, Mangere, Auckland PO Box 53177, Auckland Airport, Auckland 2150
Phone: (09) 257 3800, Fax: (09) 257 3899 Email: info@rinnai.co.nz, www.rinnai.co.nz
Important:
cnt:
Specification 4 Location 5 Clearances 6 TV installation above a fireplace 7 Installation guide overview 9 Building the frame 10 Electrical connection 10 Bracket installation 10 Fixing the unit to the frame 11 Flue installation - Rinnai flue kits 12 RDV3611 horizontal flue kits 13 RDV3611 flue components 14 Flue guidelines 16 RDV3611 flueing options 17 Gas connection 18 Flue restrictor installation 19 Log set installation 20 Test pressures 22 Flame pattern 23 Cladding 24 Fitting the frames & dress guard 25 Wiring diagram 26
4 | RDV3611 Installation Manual: 11156-A 01-12
Specication
310
1090
715
510
890
995
500
1060
400
149
750
775
845
All dimensions are in mm.
Cover panel Covers 150 mm opening on both sides of the heater. Covers are removed only when a Symmetry Heat Transfer Kit is installed.
Outer frame
1110
643
538
1006ID
Specification summary
Input = 19-33 MJ/h Output = 3.8-7.5 kW Efficiency = 80% Heating area = up to 100 m² Gas type = NG or LPG
Symmetry RDV3611
A direct vent (natural draft) inbuilt gas fireplace with a glass front and convection fan (top discharge).
Operated with a remote control (7­day programmable timer).
Combustion method
Ceramic top pan burner
Data plate
Centre front of base panel (behind the service panels)
Flue
Inner: 100 mm, outer: 170 mm. Appliance must be installed with a
Rinnai applied flue system.
Gas connection
½ “ BSP male flare
Ignition
Integrated sparker to pilot
Noise level
37-45 dB(A)
Power consumption
High = 50 W Standby = <1 W
Standard electrical connection is to the right side of the appliance.
Safety devices
Light to pilot, delayed ignition, overheat switch, electronic flame failure supervision, and combustion chamber pressure relief.
Temperature control
Thermostatic, temperature control range 7-32 °C.
Weight
60 kg
RDV3611 Installation Manual: 11156-A 01-12 | 5
Location
The main points governing location are flueing and warm air distribution. The heater must not be installed where curtains or other combustible materials could come into contact with the appliance. In some cases curtains may need restraining.
Enclosure dimensions
The heater must be positioned on a flat level surface. For installations further up the wall, the heater needs to be supported, either construct a base using board, or support with joists.
A 25 mm clearance is required around the unit (sides and back).
The 540 mm minimum dimension will give a 25 mm clearance (plus) from the back of the unit.
If installing the Symmetry Heat Transfer Kit, allow an additional side clearance of 250 mm. This clearance is required to ensure the ducting does not come into contact with the fire.
1100 - 1125 mm
850 mm min.
540 mm min.
1295 mm
1830 mm
915 mm
These are the minimum dimensions required if using the width, height, and depth dimensions above.
Enclosure dimensions in a corner
6 | RDV3611 Installation Manual: 11156-A 01-12
Clearances
The appliance must not be installed where curtains or other combustible materials could come into contact with the heater. In some case curtains may need restraining. The clearances listed below are minimum clearances unless otherwise stated.
Due to the number of different sized Symmetry frames, all dimensions are taken from the edge of the glass.
Up-wall installations If the Symmetry is being installed up the wall, the recommended minimum clearance to the ceiling is 1000 mm.
Floor protection
Heat emanating from this fire may over time affect the appearance of some materials used for flooring, such as, carpet, vinyl, cork or timber. This may be amplified if the air contains cooking vapours or cigarette smoke. To avoid this occurring, it is recommended that a mat be placed in front of this appliance.
Mantels and surrounds
A mantel and surround are allowed providing they are outside the minimum clearances shown.
Hearths
A hearth is not necessary but can be used for decorative purposes or protection of sensitive flooring if required. A hearth must not obscure the front of the fire.
1000
400
400
004
0001
To ceiling
Note
The 400 mm side clearance includes the side walls.
C - Surround from side of glass
B - Mantel depth
A - Mantel height from top of glass
D - Surround
projecon
A Mantel height from top of glass 400 mm min.
B Mantel depth at A - 400 mm (vertical clearance) 250 mm max.
For every 50 mm of added mantel depth, there must be an additional 100 mm of vertical clearance. For example; a mantel depth (B) of 350 mm will require 600 mm (A) of vertical clearance.
C Surround from side of glass 250 mm min.
D Surround projection at C - 250 mm (side clearance) 250 mm max.
RDV3611 Installation Manual: 11156-A 01-12 | 7
TV installation above a replace
If installing a flat screen TV above the fire, the main issue is heat. Heat from the fire, and heat from the flueing components that sit behind the TV—especially if recessed
The Symmetry RDV3611 has a fan that distributes warm air from the top of the appliance out into the room. As warm air is dispersed outwards, as opposed to directly upwards, installation of a TV may be an option.
The diagram shows recommended clearances when installing a TV directly above the Symmetry RDV3611, or into a recess. All dimensions are in millimetres.
400 mm dimension
The 400 mm dimension is the minimum clearance required to combustibles to a mantel.
For a TV mounted directly above the Symmetry RDV3611, the mantel must be at least the depth of the TV to deflect heat away from the appliance.
Always check with the TV supplier
It is up to the owner to check the TV installation with the TV supplier to verify clearances. Some TV manufacturers have warranty conditions that state a TV is not to be installed above a fireplace.
Rinnai does not accept any responsibility for damage to a TV resulting from the use of this information.
Mantel
400
TV
Rinnai
RDV3611
400
75
220
20
Flue
Rinnai
RDV3611
Flue
TV
Directly Above Recessed
Symmetry RDV3611
Installation
RDV3611 Installation Manual: 11156-A 01-12 | 9
Installation guide overview
This overview is intended to provide installation information at a high level. Further detail on each of the steps are provided in the following pages.
Before installation
Unpack the appliance and components, and check for damage. DO NOT install any damaged parts.
Check all components have been supplied, and that you have the correct gas type.
Read these instructions to get an overview of the steps required before starting the installation. Failure to follow these instructions could cause a malfunction of the appliance. This could result in serious injury and/or property damage.
Installation overview
1. Build the frame and complete electrical connection.
2. Install brackets, Symmetry unit, and fix the unit to the frame.
3. Install flue and complete gas connection.
4. Install ducting kit (if purchased), and gas pipe.
5. Install flue restrictor (if required), log set, test pressures, and establish flame pattern.
6. Install cladding.
7. Fit inner frame, outer frame, and mesh guard (if purchased).
8. Complete commissioning checklist.