Rinnai Symmetry RDV3610 Operation Manual

Symmetry RDV3610
Operation Manual
Recommended for a new build installation into a false (mock) chimney.
Not suitable for retrotting into an existing masonry replace.
• Appliance must be installed with a Rinnai supplied ue system.
Appliance must be installed, commissioned and serviced by a licensed tradesperson in accordance with these instructions and all applicable local rules and regulations.
LIMITED WARRANTY
Please keep these instructions in a safe place for future reference.
RECORD AND ATTACH YOUR PROOF OF PURCHASE BELOW:
Your Retailer:__________________________________________________
Name:________________________________________________________
Address:______________________________________________________
_____________________________________________________________
Telephone:( _______ ) __________________________________________
Date of Purchase: ______ / ______ / _________
TERMS AND CONDITIONS
1. During the 24 month period from date of
purchase and subject to clauses 2 and
3 below, Rinnai New Zealand Limited (“Rinnai”) will, at its own discretion, either replace or repair any defective product at
no charge to the customer.
2. This warranty covers manufacturing defects
only. This warranty will not apply if (for
example) the product has been improperly
installed or is otherwise installed contrary to manufacturer’s recommendations, has
been damaged during or after installation,
has not been operated in accordance
with operating instructions, or has been subjected to damage or abuse beyond that expected from conditions of normal use.
3. Warranty claims may be invalid if not
accompanied by details of the installing or supervising gas tter’s registration number and the gas tting certication number.
4. This warranty commences from the date of
purchase. Proof of purchase is required at the time of any warranty claim.
5. Servicing of the product is to be carried out
by a Rinnai authorised service centre.
All Rinnai appliances meet or exceed the
safety standards required by New Zealand
gas and electrical regulations. The company is constantly improving its products and as such specications are subject to change or
variation without notice.
Rinnai brings you peace of mind
with a 2 year minimum warranty.
Contents
WARNING
Improper installation, adjustment, alteration, service or maintenance
can cause property damage, personal injury or loss of life.
For assistance or additional information contact Rinnai on
0800 RINNAI (0800 746 624).
Introduction 4
Safety 5
Installation process 6
Clearances 7
Mantels, surrounds, and hearths 8
General information 9 Wireless controller 12
Operation of your RDV3610 13 Modes of operation 14
Programming your controller 15 Operation using the controller 17
Operation without the controller 18
Troubleshooting 19 Abnormal ame pattern 20 Optional accessories 21 Commissioning 23 Installer details 23
Rinnai New Zealand Limited RDV3610 Operation Manual: 11620-D
04-10
4
Introduction
Heat your home with four-star efciency
By installing a Rinnai Symmetry RDV3610 you can be condent that you are choosing an incredibly efcient and safe heating source for your home. The Rinnai Symmetry RDV3610 was awarded a four plus star energy rating after vigorous testing by the Australian Gas Association for energy efciency and safety.
Gas Consumption: 19-33 MJ/h (low to high) Output: 4.2-7.5 kW
Efciency: 80%
This manual has been written to:
• Highlight the safe operation and positioning of this appliance
• Provide advice on maintenance, servicing and troubleshooting to ensure optimum
performance
7.5 kW heat output
will warm up large
areas.
Heat additional rooms in your home with heat
ducting capacity.
The intelligent Electronic
Timer Remote (ETR) provides unmatched control of your appliance.
Ceramic liners provide additional radiant heat.
Convection fan helps to circulate heat more
efciently.
Venting can be installed
either vertically or horizontally for easy installation.
Select frameless installation to suit your own taste, or choose
from a range of framing
options.
The ember bed glow of
the burner creates one
of the most realistic­looking res available.
Direct vent technology
uses outside air to
create a healthy living
environment.
Driftwood log set
creates an attractive and contemporary look.
Large landscape window provides a great view of the re.
Rinnai New Zealand Limited RDV3610 Operation Manual: 11620-D
04-10
5
Safety
WARNING
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a
person responsible for their safety.
THE HEATER MUST NOT BE USED IF THE GLASS PANELS ARE DAMAGED
DO NOT PLACE ARTICLES ON OR AGAINST THIS APPLIANCE
DO NOT USE OR STORE FLAMMABLE MATERIALS NEAR THIS APPLIANCE
DO NOT MODIFY THIS APPLIANCE
DO NOT SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHILE IT IS IN
OPERATION
Do not restrict warm air
discharge by placing articles
in front of the appliance.
This appliance must not be used for any purpose other
than heating.
Do not spray aerosols while the appliance is
operating. Most
contain butane
gas which can be a re hazard
if used near the appliance.
Children should be supervised at all times to ensure they do not play with the appliance. Hand or body contact with the appliance must be avoided.
Do not allow anyone to sit, lean or sleep directly in front of the appliance.
Do not allow anyone to post articles
through into
the heater
Do not allow curtains or other combustible materials to come into contact with the appliance.
Do not
unplug the
appliance while it is
operating.
Do not use power boards or double adaptors to operate this appliance.
Rinnai New Zealand Limited RDV3610 Operation Manual: 11620-D
04-10
6
Installation process
Basic outline of the installation steps and trades required.
Builder
Constructs frame.
Electrician
Installs electrical connection. Standard electrical
termination is to the right
hand side of the appliance.
Gastter
Installs ue, completes gas
connection and completes installation of the Symmetry.
Builder
Installs cladding.
Rinnai New Zealand Limited RDV3610 Operation Manual: 11620-D
04-10
7
The appliance must not be installed where curtains or other combustible materials could come
into contact with the heater. In some cases curtains may need restraining.
The clearances listed below are minimum clearances unless otherwise stated. There are further
details on mantel and surround clearances on the next page.
1000
400
400
004
0001
To ceiling
Non-combusble
cladding
Non-combusble
cladding
Up-wall installations
If the Symmetry is being installed up the wall and close to the ceiling, the recommended
minimum clearance is 1000 mm.
Non-combustiblecladding
Non-combustible cladding such as 9 mm Eterpan MD1 (extending at least the full width of the appliance and 400 mm in height) to be installed directly above the re as shown. This is required to minimise the risk of scorching or re in the event of a power failure (fan will stop running and hot air will rise directly above the unit).
Floorprotection
Heat emanating from this re may over time affect the appearance of some materials used for ooring, such as, carpet, vinyl, cork or timber. This may be amplied if the air contains cooking vapours or cigarette smoke.
To avoid this occurring, it is recommended that a mat be placed in front of this
appliance.
1
9 mm Eterpan MD (medium density) is supplied by PBS Ltd (www.pbs.co.nz). Other materials may also be
suitable, please seek advice from a cladding supplier as to the correct application and specication of the material.
Clearances
Rinnai New Zealand Limited RDV3610 Operation Manual: 11620-D
04-10
8
Mantels, surrounds, and hearths
Hearths
A hearth is not necessary but can be used for decorative purposes or protection of sensitive
ooring if required. It must not obscure the front of the re.
A mantel and surround are allowed providing they are outside the minimum clearances shown
below.
A Mantel height from top of replace 400 mm minimum B Mantel depth at 400 mm (vertical clearance) 300 mm maximum
For every 50 mm of added mantel depth, there must be an additional 100 mm of vertical clearance. For
example; a mantel depth (B) of 350 mm will require 500 mm (A) of vertical clearance.
C Surround from side of replace 300 mm minimum D Surround projection at 300 mm (side clearance) 50 mm maximum
For every 50 mm of added surround projection, there must be an additional 50 mm of side clearance. For ex­ample; a surround projection (D) of 100 mm will require 350 mm (C) of side clearance.
C - Surround from side of fireplace
M
inimum Vertical Clearance 400mm
B - Mantel depth
A - Mantel height from top of fireplace
M
in
D - Surround
projecon
Loading...