Rinnai Smart Cylinders Series, Smart Cylinders MS13555030S, Smart Cylinders MS18055030S, Smart Cylinders MS25055030S Owner And Installer Manual

Owner and installer guide
Rinnai Smart Cylinders
Mains pressure
Models: MS13555030S, MS18055030S, MS25055030S
indoor stainless steel
Installer
Please leave this guide with the home owner as it contains important safety and warranty information.
Important:
- Manufacturer’s installation instructions
- Current AS/NZS 3000, AS/NZS 3500, and G12/AS1
Installation, servicing and repair shall be carried out only by authorised personnel.
Owner, please retain this guide for future reference. Installer, please leave this guide with the owner.
Warning Improper installation, adjustment, alteration, service or maintenance can cause property damage, personal injury or loss of life.
The appliance is not to be used by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction.
For more information about buying, using, and servicing of Rinnai appliances call: 0800 RINNAI (0800 746 624)
Rinnai New Zealand Limited 105 Pavilion Drive, Mangere, Auckland PO Box 53177, Auckland Airport, Auckland 2150
Phone: (09) 257 3800 Fax: (09) 257 3899 Email: info@rinnai.co.nz Web: www.rinnai.co.nz www.youtube.com/rinnainz www.facebook.com/rinnainz
cnt:
About your Rinnai Smart Cylinder ................... 4
Maintenance and servicing
Troubleshooting .............................................. 8
Installation
Specification summary .................................... 12
Dimensions ...................................................... 13
Plumbing setup ............................................... 14
Storage and delivery temperatures ................. 15
Water quality ................................................... 16
Electrical supply and connections ................... 17
Valves and fittings ........................................... 18
Commissioning ............................................... 18
10 Year Limited warranty ................................. 19
Warranty examples in the real-world .............. 22
...............................
7
Proof of purchase ............................................ 23
Installer details ................................................ 23
About your Rinnai Smart Cylinder
Your Rinnai Smart Cylinder learns the typical hot water use in the home and then heats the water to suit the anticipated demand. Energy is saved as water is not fully heated when you don't need it.
Your Rinnai Smart Cylinder comes factory preset to operate in automatic mode, at a level setting of three. We recommend staying with this setting to achieve a balance between running cost savings and ensuring you have enough hot water.
The mode button enables selection with the + and - buttons to switch between:
iQ automatic mode
Permanently monitors and learns hot water usage habits. After a minimum of one week it will automatically adjust the cylinder heating times according to your hot water usage pattern. A certain amount of hot water is guaranteed at all times depending on the level you select.
Manual mode
Permanently maintains the total volume of water at a temperature according to the selected level—operates just like a traditional electric storage cylinder.
Vacation mode
Keeps the water in the cylinder at a minimum temperature (6 °C) and prevents the water freezing in colder areas.
Child lock indicator
Screen is able to be locked to avoid settings being changed. To lock and unlock press the mode and - buttons at the same time and hold for three seconds.
Maintenance/error indicator
Error codes are indicated by the maintenance logo, a flashing background light, and the error code number.
Vacation days and error code
Displays either the number of vacation days (if set) or error code.
4 | Rinnai Smart Cylinder MP indoor stainless steel: Owner & installer guide: 20430-C 03-17
iQ automatic mode
This is the preset default mode for your
Rinnai Smart Cylinder. In this mode the level indicator displays an estimate of the amount of hot water available in the tank. The level is monitored and updated in real-time.
There are five different settings available. Your Rinnai Smart Cylinder has been preset to operate on level three which will achieve a balance between energy savings and ensuring you have enough hot water available.
Level Comfort
level
1 -- +++
2 - ++
default setting
3 + +
4 ++ -
5 +++ --
Changing the level setting
Press the + or - buttons and select the level you require— if you don't press any button for three seconds the system will set the level change. The system will then default to showing the estimated amount of hot water in the cylinder again.
Energy
saving
level
Manual mode
In manual mode the control regulates the
water temperature in the cylinder to a preset level. The temperature level is selected by using the + or - buttons, there are five different settings available.
Level Approx. water
temp. in cylinder
1 50 °C
2 55 °C
3 60 °C
4 65 °C
5 70 °C
Biosafe operation
To meet the New Zealand Building Code requirement1 to disinfect water for legionella bacteria2, the system will perform heating above 60 °C whenever risk conditions (<60 °C for 21 days) are detected.
Vacation mode
If you are going away switch the cylinder
to vacation mode. In vacation mode the cylinder will be set to maintain the water at a minimum temperature of 6 °C to prevent the water from freezing.
To select press the mode button until the suitcase icon appears. By default the number of vacation days is undefined (--). If no period is selected the cylinder will stay in vacation mode until the mode is manually changed.
The number of days (maximum 99) can be specified by using the + or ­buttons. A long press of the buttons will perform a fast speed day selection. After the specified period, the cylinder will automatically go back to the operating mode that was selected before vacation was set.
Vacation can be cancelled by pressing the iQ or manual mode buttons.
Warmup indicator
A slow blinking of the shower symbol indicates when the element is heating the water (occurs in automatic and manual modes).
1
Clause G12.3.9, Acceptable Solution G12/AS1 6.14.3
2
Legionella is a bacterium that can cause Legionnaires’ diseasea severe form of pneumonia
Rinnai Smart Cylinder MP indoor stainless steel: Owner & installer guide: 20430-C 03-17 | 5
Important
All cylinders have the potential to leak water. To minimise damage to other areas of your home, ensure that your cylinder has been installed with a drip tray—the person doing the installation is responsible for this.
* Refer to the warranty terms and conditions in this guide for more information.
Safety messages
• Element cover Do not remove the element cover, this will expose 230 V wiring, it must only be removed by an authorised person.
• Damaged components If any component is damaged, it must be replaced by an authorised person using Rinnai replacement parts.
• Child supervision
Children should be supervised to ensure they do not play with any part of the hot water system.
• Hot pipe work
Care should be taken not to touch the pipe work from the cylinder as this could be very hot.
• Temperature override cutout for heating element.
The operation of the thermal cutout can indicate a dangerous situation. Do not reset the thermal cutout until the water heater has been serviced by a qualified person.
Do not operate the system unless all the safety devices are fitted and are in working order. It is also important that you do not tamper or remove any of these devices.
Draining and filling the system
This normally occurs during installation or servicing and must be carried out by an authorised person.
Turning the cylinder on/off (we don't recommend this)
If you switch the
IMPORTANT
cylinder off for more than 18 hours it will lose all the water usage history.
Safety devices
Your cylinder is fitted with a:
• Temperature & Pressure Relief (TPR) valve that ensures the water remains at a safe pressure and temperature.
Installation by a licensed tradesperson
Only a licensed tradesperson can install, adjust, maintain, and service this water heater. Any work carried out by a non-licensed tradesperson is illegal and will void any
• Automatic thermostat
warranty. to maintain water temperature.
6 | Rinnai Smart Cylinder MP indoor stainless steel: Owner & installer guide: 20430-C 03-17
Maintenance and servicing
IMPORTANT
Hot water systems, like cars, require regular maintenance and servicing. To ensure longevity of your cylinder we recommend the following.
Period What needs to be done
Every six months TPR (temperature & pressure relief) valve—operate the easing gear
Year five Inspection and service of the entire hot water system, including the element*
Every 24 months after year five
* In hard water areas the element(s) must be periodically descaled. To do this the unit must be drained and the element removed.
TPR valve
This valve is located near the top of the cylinder and is essential for safe operation. The TPR valve works by automatically venting hot water if the temperature or pressure of the water in the cylinder gets too high.
Every six months operate the easing gear to remove lime deposits and to check that it is not blocked. As this will discharge hot water, ensure no one is near the drain line.
Failure to operate the relief valve
WARNING
easing gear at
least once every six months may result in the water heater exploding.
Inspection and service of the entire hot water system, including the element*
from the valve may indicate a problem. It is important that you raise and lower the easing gear gently. During
A TPR valve must not be replaced with one that has a higher pressure rating than
that specified for the cylinder. the operation, if the valve does not discharge water when the easing gear is lifted, or does not seal again when closed, arrange for an authorised person to come and inspect the system immediately.
Maintenance and servicing
Rinnai has a maintenance,
service, and spare parts
network with personnel who
are fully trained and equipped
to give the best advice on
your Rinnai product. Regular
maintenance and servicing
During servicing of your cylinder the
is not covered by the Rinnai
warranty.
TPR valve needs to be checked and/or replaced. This needs to be done by an authorised person at intervals
For help locating a service person in your area call 0800
RINNAI (0800 746 624). not exceeding five years, or more frequently in areas where the water is classified as hard.
Continuous leakage of water
top of cylinder
How to operate the easing gearTPR position -
To water heater
Insulated TPR valves will look like the image below
Lift until water flows from the drain line, lower gently
To drain line
Rinnai Smart Cylinder MP indoor stainless steel: Owner & installer guide: 20430-C 03-17 | 7
Troubleshooting
Do not attempt to carry out any work other than that mentioned in this troubleshooting section. If you have any other faults or problems, please contact your installer, or contact Rinnai.
Problem Recommended action
Error code is flashing on the controller
No display on the controller, but power is on and you have hot water
Nothing happens when the buttons are pressed
I have cold water while in iQ automatic mode
Error codes are indicated by the maintenance logo, a flashing background light, and the error code number.
Take a note of the error code and phone Rinnai Customer Services (0800 746 624) for advice on whether a plumber or electrician is required.
Call Rinnai Customer Services (0800 746 624).
Check if the child lock is set. Unlock by pressing the mode and ­buttons at the same time for more than three seconds.
A sudden significant increase of hot water consumption may generate occasional cold water. Change to manual mode and select the desired temperature level and then go back to iQ mode.
If this occurs regularly, increase the level in iQ mode or occasionally go into manual mode.
Lack of hot water or no hot water
Is there electricity supply to the cylinder?
Check that the isolating switch marked ‘hot water’ or ‘water heater’, at the meter box, is switched on. Also check any isolating switches near the water heater are switched on.
Check the fuse or circuit breaker marked ‘hot water’ or ‘water heater’ at the meter box. Repeated failure of the fuse or tripping of the circuit breaker indicates a fault, which must be investigated by an authorised tradesperson.
Most hot water cylinders are controlled at peak times by your electricity supplier via a ripple relay. Contact your electricity supplier to determine if there have been any issues with the power supply.
8 | Rinnai Smart Cylinder MP indoor stainless steel: Owner & installer guide: 20430-C 03-17