Rinnai SFD01 Installation Guide

RINNAI SIDEWAYS FLUE DIVERTER SFD-01
INSTALLATION INSTRUCTIONS
General Information
Rinnai sideways flue diverter SFD-01 fits the following Rinnai Continuous Flow water heater models: REU-V2626WG - INFINITY 26
REU-VM2630WD - INFINITY 26 Plus REU-VM2630WC - HD 200e REU-V2426WS - S26 REU-V2426WB - V1500
component of the water heater appliances with which it is compatible. For the certification number see the data plate on the appliance.
Installation of heater and flue system shall be in accordance with:
IMPORTANT
• Manufacturers Installation Instructions.
• Current AS 5601 Gas Installations.
• Local Regulations and Municipal Building Codes. Installation, service and removal by an Authorised Person only. Continuous flow water heater to be installed in accordance with the 'Operation / Installation Manual' supplied with the appliance.
Applications
The Rinnai sideways flue diverter is intended for fitting to Rinnai continuous flow water heaters installed on balconies, patios or similarly enclose d areas to facilitate free products out of the enclosed area. This may not occur if the appliance is installed without the sideways flue diverter.
Rinnai external continuous flow water heaters mounted against a wall without the sideways flue diverter, will expel flue products in a horizontal direction outwards and away from the wall against which the appliance is mounted. Fitment of the sideways flue diverter results in the flue products being expelled from the appliance in a sideways direction, along the wall as shown in Figure 1.
Installation Requirements
Figure 2 (on page 2) shows the location conditions and clearances which apply when Rinnai continuous flow water heaters are fitted with the sideways flue diverter and installed on balconies, patios or similarly enclosed areas. Other relevant clearances in Figure 5.3 of AS5601 continue to apply when the sideways flue diverter is fitted.
• Fitment of the Rinnai sideways flue diverter is suitable ONLY when all f lue products
IMPORTANT
result in being expelled freely into an above ground open-air situation with natural ventilation, without stagnant areas where products of combustion are rapidly dispersed by wind and natural convection.
• The Rinnai sideways flue diverter is not suitable for Rinnai continuous flow water heaters installed in recess boxes.
• Rinnai sideways flue diverter SFD-01 is suitable for single wate r heater applications only. It is not suitable for multiple installations of Rinnai continuous flow water heaters on one balcony, patio or similarly enclosed space.
• The Rinnai sideways flue diverter is certified for use only with the Rinnai c ontinuous flow water heater models listed in this Instruction. It is not compatible with any other Rinnai or other manufacturers' appliances.
explusion of combustion
Rinnai 1 SFD01 Installation Instruction
A
LOCATION CONDITIONS AND CLEARANCES
APPLICATIONS
INSTALLATION
i
Preparation
1. Unpack the diverter assembly from it’s packaging.
2. Remove the two retaining screws from the front of the box panel .
3. Separate the mounting bracket from the rear of the box panel .
Rinnai 2 SFD01 Installation Instruction
B
C
B
D
D
Apply warning label to water heater, aligning the label to the right edge and 5mm below the flue spigot.
5mm
INSTALLATION
ii
Fitting Mounting Bracket To The Appliance
4. Loosen the 2 adjustment screws located on both ends of mounting bracket .
C
This allows cup hooks of the mounting bracket to be positioned inside the lip of
C F
the appliance flue terminal .
iiiii
Securing Mounting Bracket To The Appliance
5. Align the cup hooks with the lip so that
E
G
E F
when the 2 adjustment screws are re­tightened both will engage.
6. Re-tighten the 2 adjustment screws until the cup hooks and the lip are firmly engaged
E F
D
and secured.
7. Apply the warning label to water heater, aligning the label to the right edge and 5mm below the flue spigot as shown.
The warning label becomes hidden once
NOTE
the sideways flue diverter is fitted to the appliance. This warning label reminds a serviceperson to replace the sideways flue diverter after servicing activities.
iv
Attaching The Box Panel
8. Re-attach the box panel to the mounting bracket with the retaining screws
C
B
A
removed in step 2. Ensure that the drainage holes are pointing
downwards. See step for details of left or
v
H
right handed flue product discharge.
Rinnai 3 SFD01 Installation Instruction
INSTALLATION
v
Left Or Right Handed Installations
9. The sideways diverter can be installed for left or right handed flue product discharge.
To set the direction of discharge remove the four retaining screws from the top and bottom of the box panel.
I
10. Remove both the terminal and the blanking
K
plate from each and reverse their positions to
J
suit discharge requirements.
11. Re-secure the terminal and the blanking plate in the new position with the four retaining screws removed in step 8.
K
I
J
For Western Australia only:
Energy Safety WA Notice of Exemption V/E 07/03 authorises the installation of Rinnai Sideways Flue Diverter SFD-01 in Western Australia in accordance with these Installation Instructions. The installer is to record Notice of Exemption number V/E 07/03 on the Energy Safety WA compliance badge under “Special Conditions”.
Rinnai 4 SFD01 Installation Instruction - May'07